首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with side- bonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in ACI-440 and fib European code were compared with the experimental results.  相似文献   

2.
二次受力下碳纤维布加固梁抗弯性能试验研究   总被引:1,自引:0,他引:1  
进行了4根不同二次受力条件下碳纤维布加固的钢筋混凝土梁和1根对比混凝土梁的抗弯性能试验研究。试验及分析结果表明,用粘贴碳纤维布的方法来提高梁的承载力十分有效,且预加载的存在使加固梁的极限荷载降低;碳纤维布能有效约束裂缝的开展,但裂缝的数量增加和分布区域变大,且预加载的大小会影响加固梁裂缝的开展和分布;碳纤维布加固可以增强梁的刚度,但延性有所降低。  相似文献   

3.
Extensive research has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suitable for improving the fatigue behavior of reinforced concrete (RC) beams. This paper presents the research on flexural rigidity evolvement laws by testing 14 simple-supported RC beams strengthened with carbon fiber laminates (CFL) under cyclic load, and 2 under monotone load as a reference. The cyclic load tests revealed the peak load applied onto the surface of a supported RC beam strengthened with CFL is linear to the logarithm of its fatigue life, and the flexural rigidity evolvement undergoes three distinct phases: a rapid decrease from the start to about 5% of the fatigue life; an even development from 5% to about 99% of the fatigue life; and a succedent rapid decrease to failure. When the ratio of fatigue cycles to the fatigue life is within 0.05 to 0.99, the flexural rigidity varies linearly with the ratio. The peak load does not affect the flexural rigidity evolvement if it is not high enough to make the main reinforcements yield. The dependences of the flexural rigidity of specimens formed in the same group upon their fatigue cycles normalized by fatigue life are almost coincident. This implies the flexural rigidity may be a material parameter independent of the stress level. These relationships of flexural rigidity to fatigue cycles, and fatigue life may be able to provide some hints for fatigue design and fatigue life evaluation of RC member strengthened with CFL; nevertheless the findings still need verifying by more experiments.  相似文献   

4.
通过9根表层嵌入碳纤维增强塑料板条抗剪加固的钢筋混凝土梁和4根对比梁的静载试验,分析了构件的破坏形态、斜截面纤维应变分布特征及加固后极限承载力的影响因素。研究结果表明:嵌入式加固与外贴加固相比,可以明显地提高钢筋混凝土梁的抗剪承载力,并改变构件的变形性能。最后,在国内外研究资料的基础上,提出了加固后混凝土梁的受剪承载力计算公式,并对计算值与试验值进行了比较,结果吻合较好。  相似文献   

5.
对9根玻璃纤维布加固的钢筋混凝土梁和3根对比梁进行了抗弯性能试验研究. 试验中考虑了配筋率、加固量、剪跨比与混凝土强度等级4个参数. 试验结果表明, 经玻璃纤维布加固的钢筋混凝土梁抗弯承载力有显著提高; 混凝土强度、配筋率、加固量对极限荷载有显著影响; 剪跨比对加固梁的破坏形态有影响. 根据不同的破坏模式, 提出了抗弯承载力计算方法.  相似文献   

6.
为研究碳纤维布(CFRP)对加固后钢筋混凝土梁的抗弯疲劳性能的影响,进行了3根CFRP加固梁及1根对比梁的抗弯疲劳试验.研究了碳纤维布加固方式、构件使用荷载等参数对碳纤维布加固损伤钢筋混凝土吊车梁的抗弯疲劳性能影响.试验研究表明:采用碳纤维布加固后,构件裂缝的宽度减小50.2%~66%,发展速度也得到控制,钢筋应力减小24.1%~28.2%,构件的刚度提高14.9%~16.1%.依据试验结果,从现有规范中关于构件刚度计算方法出发,进行了CFRP加固钢筋混凝土吊车梁的疲劳刚度计算分析,该计算方法可用于吊车梁加固工程设计.最后给出了CFRP加固梁的疲劳设计的合理化建议.  相似文献   

7.
Carbon fiber reinforced polymer(CFRP)bars were prestressed for the structural strengthening of 8 T-shaped rein-forced concrete (RC)beams of a 21-year-old bridge in China.The ultimate bearing capacity of the existing bridge after retrofit was discussed on the basis of concrete structures theory.The flexural strengths of RC beams strengthened with CFRP bars were controlled by the failure of concrete in compression and a prestressing method was applied in the retrofit.The field construction processes of strengthening with CFRP bars-including grouting cracks,cutting groove,grouting epoxy and embedding CFRP bars,surface treating,banding with the U-type CFRP sheets,releasing external prestressed steel tendons-were introduced in detail.In order to evaluate the effectiveness of this strengthening method,field tests using vehicles as live load were applied before and after the retrofit.The test results of deflection and concrete strain of the T-shaped beams with and without strengthening show that the capacity of the repaired bridge,including the bending strength and stiffness,is enhanced.The measurements of crack width also indicate that this strengthening method can enhance the durability of bridges.Therefore,the proposed strengthening technology is feasible and effective.  相似文献   

8.
Carbon fiber reinforced polymer (CFRP) bars were prestressed for the structural strengthening of 8 T-shaped reinforced concrete (RC) beams of a 21-year-old bridge in China. The ultimate bearing capacity of the existing bridge after retrofit was discussed on the basis of concrete structures theory. The flexural strengths of RC beams strengthened with CFRP bars were controlled by the failure of concrete in compression and a prestressing method was applied in the retrofit. The field construction processes of strengthening with CFRP bars including grouting cracks, cutting groove, grouting epoxy and embedding CFRP bars, surface treating, banding with the U-type CFRP sheets, releasing external prestressed steel tendons-were introduced in detail. In order to evaluate the effectiveness of this strengthening method, field tests using vehicles as live load were applied before and after the retrofit. The test results of deflection and concrete strain of the T-shaped beams with and without strengthening show that the capacity of the repaired bridge, including the bending strength and stiffness, is enhanced. The measurements of crack width also indicate that this strengthening method can enhance the durability of bridges. Therefore, the proposed strengthening technology is feasible and effective.  相似文献   

9.
预应力CFRP加固法较非预应力CFRP加固法更能发挥CFRP高强的材料性能,具有更加广阔的应用前景。本文就预应力CFRP加固法的材料特点、预应力施加工艺、应用进展以及国内外的研究现状作了总结,并展望了此方法的未来研究方向。  相似文献   

10.
为了研究钢筋增强ECC梁受弯性能,进行了钢筋增强ECC梁和普通钢筋混凝土梁受弯的对比研究.结果表明,相比普通钢筋混凝土梁,钢筋增强ECC梁的受弯承载力和延性分别提高了24.8%和187.76%,并且在梁中用ECC代替混凝土可有效延缓裂缝的发展.此外,采用简化的ECC本构模型对钢筋增强ECC及混凝土梁的受弯性能进行了非线性有限元分析,模拟结果与试验结果吻合较好,在服役期间钢筋增强ECC梁的裂缝可以控制在0.4 mm以下.ECC材料的使用可明显提高梁的抗弯承载力、变形能力、延性等受弯性能.  相似文献   

11.
对15根玻璃纤维布加固的钢筋混凝土梁进行了试验研究。试验结果表明,玻璃纤维布加固的钢筋混凝土梁抗弯承载力显著提高,加固效果明显,但要有足够的粘贴长度以避免发生剥离破坏。  相似文献   

12.
This paper presents the results of an experimental research on reinforced concrete beams strengthened with an external carbon fibre reinforced polymer(CFRP) layer under long-term load action that lasted for 330 d.We describe the characteristics of deflection development of the beams strengthened with different additional anchorages of the external carbon fibre composite layer during the period of interest.The conducted experiments showed that the additional anchorage influences the slip of the external layer with respect to the strengthened element.Thus,concrete and carbon fibre composite interface stiffness decreases with a long-term load action.Therefore,the proposed method of analysis based on the built-up-bars theory can be used to estimate concrete and carbon fibre composite interface stiffness in the case of long-term load.  相似文献   

13.
INTRODUCTION The aging or deterioration of existing R. C.(reinforced concrete) or P. C. (prestressed concrete)structures is one of the major problems that modernengineers have to face. If the flexural or shear strengthof R. C. or P. C. structures is not sufficient to maintaintheir service functions, strengthening of these struc-tures becomes necessary. To date, steel plates havebeen used to strengthen concrete members. Usingcomposite plates to strengthen R.C. or P.C. structures…  相似文献   

14.
This work is aimed at studying the strengthening of reinforced concrete (R. C.) beams using prestressed glass fiber-reinforced polymer (PGFRP). Carbon fiber-reinforced polymer (CFRP) has recently become popular for use as repair or rehabilitation material for deteriorated R. C. structures, but because CFRP material is very stiff, the difference in CFRP sheet and concrete material properties is not favorable for transferring the prestress from CFRP sheets to R. C. members. Glass fiber-reinforced polymer (GFRP) sheets with Modulus of Elasticity quite close to that of concrete was chosen in this study. The load-carrying capacities (ultimate loads) and the deflections of strengthened R. C. beams using GFRP and PGFRP sheets were tested and compared. T- and ⊥-shaped beams were used as the under-strengthened and over-strengthened beams. The GFRP sheets were prestressed to one-half their tensile capacities before being bonded to the T- and l-shaped R. C. beams. The prestressed tension in the PGFRP sheets caused cambers in the R. C. beams without cracks on the tensile faces. The PGFRP sheets also enhanced the load-carrying capacity. The test results indicated that T-shaped beams with GFRP sheets increased in load-carrying capacity by 55% while the same beams with PGFRP sheets could increase load-carrying capacity by 100%. The ⊥-shaped beams with GFRP sheets could increase load-carrying capacity by 97% while the same beams with PGFRP sheets could increase the loading-carrying capacity by 117%. Under the same external loads, beams with GFRP sheets underwent larger deflections than beams with PGFRP sheets. While GFRP sheets strengthen R. C. beams, PGFRP sheets decrease the beams' ductility, especially for the over-strengthened beams (⊥-shaped beams).  相似文献   

15.
为了解玻璃纤维(GFRP)布与钢筋混凝土梁界面之间的粘结性能,进行了7根GFRP布加固的钢筋混凝土梁与2根对比梁的试验研究.试验的变化参数为GFRP布层数、粘结长度及配筋率.试验结果表明,GFRP布加固的钢筋混凝土梁极限荷载显著提高,但是发生剥离破坏的试验梁极限荷载有所降低,粘结长度是影响加固梁剥离破坏的主要因素.根据试验结果提出了GFRP布与钢筋混凝土梁界面粘结剪应力的试验分析方法并分析了界面间粘结剪应力的分布.同时,提出了GFRP布加固的钢筋混凝土梁剥离正应力与粘结剪应力的理论分析方法.最后,给出了GFRP布加固钢筋混凝土梁剥离荷载的计算方法.为验证理论分析方法的正确性,计算了试验梁界面间的粘结剪应力、剥离正应力及剥离荷载.计算结果表明,所提出的理论分析方法与试验值吻合较好.  相似文献   

16.
通过对三面围覆碳纤维布进行加固的钢筋混凝土T形梁的试验,探讨了梁的受弯破坏形态、极限状态和设计要求,并根据实测纤维布极限应变值,讨论了纤维布允许拉应变的取值问题。  相似文献   

17.
Prestressed steel ultrahigh-strength reinforced concrete (PSURC) beam is a new type of prestressed concrete beam, which not only has a considerable compressive strength attributed to the ultrahigh strength concrete, but also ensures a certain degree of ductility at failure due to the existence of structural steel. Five of these beams were monotonically tested until shear failure to investigate the static shear performance including the failure pattern, load-deflection behavior, shear capacity, shear crack width and shear ductility. The experimental results show that these beams have superior shear capacity, crack control ability and shear ductility. To study the shear performance under repeated overloading, seven PSURC beams were loaded in cyclic test simultaneously. The overall shear performance of cycled beams is similar to that of uncycled beams at low load level but different at high load level. The shear capacity and crack control ability of cycled beams at high load level are reduced, whereas the shear ductility is improved. In addition, the influences of variables including the degree of prestress, stirrup ratio and load level on the shear performance of both uncycled and cycled beams were also discussed and compared, respectively.  相似文献   

18.
为了更好地保护古建筑,采用试验方法研究了CFRP加固古建筑榫卯节点后的抗震性能.基于某古建筑实际尺寸,制作了1:8缩尺比例的木结构空间框架模型,并考虑梁柱连接为燕尾榫形式.进行了低周反复加载试验,包括3组未加固构架试验和2组CFRP加固试验.基于试验相关数据,获得了节点的弯矩-转角滞回曲线和骨架曲线,并对比分析了节点加...  相似文献   

19.
采用Ansys有限元软件对8根不同锈蚀率的FRP片材加固钢筋混凝土梁的受弯性能进行数值分析,研究纵筋锈蚀率对FRP加固梁的裂纹开展、破坏模式、承载能力以及延性和变形能力的影响.研究结果表明:低钢筋锈蚀率的梁发生受压区混凝土压碎破坏;中等锈蚀率的梁钢筋屈服后,钢筋与混凝土界面发生黏结滑移,最后FRP剥离破坏;高锈蚀率的梁钢筋没有达到屈服强度便发生黏结滑移,最后发生受压区混凝土压碎破坏.钢筋锈蚀越严重,FRP加固钢筋混凝土梁的承载力降低得越多.试件RCB-1(锈蚀率为0)的承载力为115 kN,而试件RCB-7(锈蚀率为20%)的承载力仅为42 kN.与FRP加固未锈蚀的钢筋混凝土梁相比,FRP加固锈蚀钢筋混凝土梁的变形能力较高.试件RCB-1和试件RCB-7的最大跨中挠度分别为20 mm和35 mm,而试件RCB-5(锈蚀率为10%)的最大跨中挠度达到了60 mm.  相似文献   

20.
Finite element analysis and parametric studies were performed to investigate the flexural capacity of the panel zone of diaphragm-through joints between concretefilled square steel tubular columns and H-shaped steel beams.Through the comparisons of failure modes,load–displacement curves,and bearing capacity,it was found that the flexural capacity of the panel zone of diaphragmthrough joints was determined by the tensile action and influence of the web of H-shaped steel beams,and the axial load should be taken into account.The steel tube and the diaphragm were the major parts of the joint that resisted the bending moment.The contribution of in-filled concrete had little influence on the flexural capacity of the panel zone of the joint and could be neglected.According to the results of these numerical studies,a formula that considered the influence of the web of H-shaped steel beams and the axial load was developed based on the yield lines in the diaphragm and the steel tube.The results of the proposed formula were in good agreement with the numerical data of this investigation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号