首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
We introduce a new model for contact angle saturation phenomenon in electrowetting on dielectric systems. This new model attributes contact angle saturation to repulsion between trapped charges on the cap and base surfaces of the droplet in the vicinity of the three-phase contact line, which prevents these surfaces from converging during contact angle reduction. This repulsion-based saturation is similar to repulsion between charges accumulated on the surfaces of conducting droplets which causes the well known Coulombic fission and Taylor cone formation phenomena. In our model, both the droplet and dielectric coating were treated as lossy dielectric media (i.e., having finite electrical conductivities and permittivities) contrary to the more common assumption of a perfectly conducting droplet and perfectly insulating dielectric. We used theoretical analysis and numerical simulations to find actual charge distribution on droplet surface, calculate repulsion energy, and minimize energy of the total system as a function of droplet contact angle. Resulting saturation curves were in good agreement with previously reported experimental results. We used this proposed model to predict effect of changing liquid properties, such as electrical conductivity, and system parameters, such as thickness of the dielectric layer, on the saturation angle, which also matched experimental results.  相似文献   

2.
Lee DH  Lee W  Um E  Park JK 《Biomicrofluidics》2011,5(3):34117-341179
Precise temporal control of microfluidic droplets such as synchronization and combinatorial pairing of droplets is required to achieve a variety range of chemical and biochemical reactions inside microfluidic networks. Here, we present a facile and robust microfluidic platform enabling uniform interval control of flowing droplets for the precise temporal synchronization and pairing of picoliter droplets with a reagent. By incorporating microbridge structures interconnecting the droplet-carrying channel and the flow control channel, a fluidic pressure drop was derived between the two fluidic channels via the microbridge structures, reordering flowing droplets with a defined uniform interval. Through the adjustment of the control oil flow rate, the droplet intervals were flexibly and precisely adjustable. With this mechanism of droplet spacing, the gelation of the alginate droplets as well as control of the droplet interval was simultaneously achieved by additional control oil flow including calcified oleic acid. In addition, by parallel linking identical microfluidic modules with distinct sample inlet, controlled synchronization and pairing of two distinct droplets were demonstrated. This method is applicable to facilitate and develop many droplet-based microfluidic applications, including biological assay, combinatorial synthesis, and high-throughput screening.  相似文献   

3.
Lee CP  Chen HC  Lai MF 《Biomicrofluidics》2012,6(1):12814-128148
This study experimentally verifies that the mixing process in a droplet can be enhanced by driving the droplet at resonant frequencies and at alternating driving frequencies using a parallel-plate electrowetting on dielectric device. The mixing time, which is defined as the time required for reaching the well-mixed state, in a resonant droplet is found to be significantly shorter than that in a non-resonant droplet. Besides, it is also found that a higher driving potential leads to a better mixing effect, especially at resonant frequencies. Furthermore, when a droplet is driven by alternating two driving frequencies, especially two resonant frequencies, the mixing efficiency is found to be significantly enhanced for a specific alternating duration of these two frequencies.  相似文献   

4.
Im do J  Noh J  Yi NW  Park J  Kang IS 《Biomicrofluidics》2011,5(4):44112-4411210
We experimentally investigate the effects of high electric field on living cells inside a charged droplet under electrophoretic actuation. When an aqueous droplet suspended in a dielectric liquid contacts with electrified electrode, the droplet acquires charge. This charged droplet undergoes electrophoretic motion under strong electric field (1–3 kV/cm), which can be used as a droplet manipulation method in biomicrofluidic applications. However, because strong electric field and use of dielectric oil can be a harmful environment for living cells, the biological feasibilities have been tested. Trypan blue test and cell growth test have been performed to check the viability and proliferation of cells in a droplet under various electric field strengths and actuation times. We have not observed any noticeable influence of electric field and silicone oil on the viability and proliferation of cells, which indicates that electrophoresis could be safely used as a manipulation method for a droplet containing living biological system.  相似文献   

5.
This work proposes the use of charged droplets driven by the Coulombic force as solution-phase reaction chambers for biological microreactions. A droplet can be charged near an electrode under dc voltage by direct contact to the electrode. This process is called electrical charging of droplet (ECOD). This charged droplet can then be transported rapidly between electrodes following the arc of an electric field line by exploiting electrostatic force. As on-demand electrocoalescence, both alkalization of phenolphthalein and bioluminescence reaction of luciferase in the presence of adenosine triphosphate are studied to test the feasibility of the biochemical microreactors using ECOD. Two oppositely charged droplets are merged to have a color change immediately after microchemical reaction. The applicability of an ECOD-driven droplet to measurement of glucose concentration is also tested. The glucose concentration is measured using a colorimetric enzyme-kinetic method based on Trinder’s reaction [J. Clin. Pathol. 22, 158 (1969)]. The color change in the merged droplet is detected with an absorbance measurement system consisting of a photodiode and a light emitting diode.  相似文献   

6.
In this study, we simulated deformation and surfactant distribution on the interface of a surfactant-covered droplet using optical tweezers as an external source. Two optical forces attracted a single droplet from the center to both sides. This resulted in an elliptical shape deformation. The droplet deformation was characterized as the change of the magnitudes of surface tension and optical force. In this process, a non-linear relationship among deformation, surface tension, and optical forces was observed. The change in the local surfactant concentration resulting from the application of optical forces was also analyzed and compared with the concentration of surfactants subjected to an extensional flow. Under the optical force influence, the surfactant molecules were concentrated at the droplet equator, which is totally opposite to the surfactants behavior under extensional flow, where the molecules were concentrated at the poles. Lastly, the quasi-equilibrium surfactant distribution was obtained by combining the effects of the optical forces with the extensional flow. All simulations were executed by the lattice Boltzmann method which is a powerful tool for solving micro-scale problems.  相似文献   

7.
We here present and characterize a programmable nanoliter scale droplet-on-demand device that can be used separately or readily integrated into low cost single layer rapid prototyping microfluidic systems for a wide range of user applications. The passive microfluidic device allows external (off-the-shelf) electronically controlled pinch valves to program the delivery of nanoliter scale aqueous droplets from up to 9 different inputs to a central outlet channel. The inputs can be either continuous aqueous fluid streams or microliter scale aqueous plugs embedded in a carrier fluid, in which case the number of effective input solutions that can be employed in an experiment is no longer strongly constrained (100 s–1000 s). Both nanoliter droplet sequencing output and nanoliter-scale droplet mixing are reported with this device. Optimization of the geometry and pressure relationships in the device was achieved in several hardware iterations with the support of open source microfluidic simulation software and equivalent circuit models. The requisite modular control of pressure relationships within the device is accomplished using hydrodynamic barriers and matched resistance channels with three different channel heights, custom parallel reversible microfluidic I/O connections, low dead-volume pinch valves, and a simply adjustable array of external screw valves. Programmable sequences of droplet mixes or chains of droplets can be achieved with the device at low Hz frequencies, limited by device elasticity, and could be further enhanced by valve integration. The chip has already found use in the characterization of droplet bunching during export and the synthesis of a DNA library.  相似文献   

8.
We present a novel use for channel structures in microfluidic devices, whereby two two-phase emulsions, one created on-chip, the other off-chip, are rapidly mixed with each other in order to allow for the coalescence of one emulsion with the other. This approach has been motivated by the difficulty in introducing aqueous cross linking agents into droplets by utilising conventional approaches. These conventional approaches include continuous introduction of the different aqueous reagents before droplet formation or alternatively formation of individual droplets of each reagent and subsequent droplet merging later in the microfluidic device. We show that our approach can decrease the mixing time for these fluidic systems by a factor greater than 10 times when compared to a standard microfluidic channel without structures, thereby also allowing for additional reaction time within the microfluidic device. This method shows an application for microfluidic channel structures not before demonstrated, also demonstrating an alternative method for introducing reagents such as cross linkers which link polymer chains to form particles, and provides an example where enzymes are immobilized in monodisperse particles.  相似文献   

9.
Nguyen HB  Chen JC 《Biomicrofluidics》2012,6(1):12809-1280913
We conduct a numerical investigation and analytical analysis of the effect of slippage on the thermocapillary migration of a small liquid droplet on a horizontal solid surface. The finite element method is employed to solve the Navier-Stokes equations coupled with the energy equation. The effect of the slip behavior on the droplet migration is determined by using the Navier slip condition at the solid-liquid boundary. The results indicate that the dynamic contact angles and the contact angle hysteresis of the droplet are strictly correlated to the slip coefficient. The enhancement of the slip length leads to an increase in the droplet migration velocity due to the enhancement of the net momentum of thermocapillary convection vortices inside the droplet. A larger contact angle leads to an increase in the migration velocity which in turn enlarges the rate of the droplet migration velocity to the slip length. There is good agreement between the analytical and the numerical results when the dynamic contact angle utilizes in the analytical approach obtained from the results of the numerical computation, and the static contact angle is smaller than 50°.  相似文献   

10.
Novel on-demand droplet generation for selective fluid sample extraction   总被引:1,自引:0,他引:1  
Lin R  Fisher JS  Simon MG  Lee AP 《Biomicrofluidics》2012,6(2):24103-2410310
A novel microfluidic device enabling selective generation of droplets and encapsulation of targets is presented. Unlike conventional methods, the presented mechanism generates droplets with unique selectivity by utilizing a K-junction design. The K-junction is a modified version of the classic T-junction with an added leg that serves as the exit channel for waste. The dispersed phase fluid enters from one diagonal of the K and exits the other diagonal while the continuous phase travels in the straight leg of the K. The intersection forms an interface that allows the dispersed phase to be controllably injected through actuation of an elastomer membrane located above the inlet channel near the interface. We have characterized two critical components in controlling the droplet size-membrane actuation pressure and timing as well as identified the region of fluid in which the droplet will be formed. This scheme will have applications in fluid sampling processes and selective encapsulation of materials. Selective encapsulation of a single cell from the dispersed phase fluid is demonstrated as an example of functionality of this design.  相似文献   

11.
Deformation-based circulating tumor cell (CTC) microchips are a representative diagnostic device for early cancer detection. This type of device usually involves a process of CTC trapping in a confined microgeometry. Further understanding of the CTC flow regime, as well as the threshold passing-through pressure, is a key to the design of deformation-based CTC filtration devices. In the present numerical study, we investigate the transitional deformation and pressure signature from surface tension dominated flow to viscous shear stress dominated flow using a droplet model. Regarding whether CTC fully blocks the channel inlet, we observe two flow regimes: CTC squeezing and shearing regime. By studying the relation of CTC deformation at the exact critical pressure point for increasing inlet velocity, three different types of cell deformation are observed: (1) hemispherical front, (2) parabolic front, and (3) elongated CTC co-flowing with carrier media. Focusing on the circular channel, we observe a first increasing and then decreasing critical pressure change with increasing flow rate. By pressure analysis, the concept of optimum velocity is proposed to explain the behavior of CTC filtration and design optimization of CTC filter. Similar behavior is also observed in channels with symmetrical cross sections like square and triangular but not in rectangular channels which only results in decreasing critical pressure.  相似文献   

12.
Using a membrane emulsification method based on porous hollow-fiber membranes in combination with an aqueous two-phase system (ATPS), we are able to produce “water-in-water” droplets with narrow-dispersed size distributions. The equilibrium phases of the aqueous two-phase system polyethylene glycol-dipotassium hydrogen phosphate are used for this purpose. The droplet diameter of a given fluid system is determined by the flow rates of the continuous and disperse phase as well as the hollow fiber dimensions. When diluting the disperse phase and thus moving the ATPS system out of equilibrium, the droplet size can be further reduced in comparison to the equilibrium case. Generally, droplets formed with this method have diameters 20%–60% larger than the inner hollow fiber diameter. The new strategy of diluting the disperse phase allows the production of droplet diameter below the inner diameter of the membrane.  相似文献   

13.
We evaluate the feasibility of manipulating droplets in two dimensions by exploiting Coulombic forces acting on conductive droplets immersed in a dielectric fluid. When a droplet suspended in an immiscible fluid is located near an electrode under a dc voltage, the droplet can be charged by direct contact, by charge transfer along an electrically conducting path, or by both mechanisms. This process is called electrical charging of droplet (ECOD). This charged droplet may then be transported rapidly by exploiting Coulombic forces. We experimentally demonstrate electrical actuation of a charged droplet by applying voltage sequences. A charged droplet is two dimensionally actuated by following the direction of the electrical field signal. The droplet does not contact the surface of the microfluidic chip when it moves. This characteristic is very advantageous because treatments of the substrate surfaces of microfluidic chip become simpler. In order to test the feasibility of using ECOD in a droplet-based microreactor, electrocoalescence of two oppositely charged droplets is also studied. When two droplets approach each other due to Coulombic attraction, a liquid bridge is formed between them. We postulate that if the applied electric field is weaker than a certain critical level, the two droplets coalesce instantaneously when the charges are exchanged and redistributed through this liquid bridge.  相似文献   

14.
We report an in-depth study of the long-term reproducibility and reliability of droplet dispensing in digital microfluidic devices (DMF). This involved dispensing droplets from a reservoir, measuring the volume of both the droplet and the reservoir droplet and then returning the daughter droplet to the original reservoir. The repetition of this process over the course of several hundred iterations offers, for the first time, a long-term view of droplet dispensing in DMF devices. Results indicate that the ratio between the spacer thickness and the electrode size influences the reliability of droplet dispensing. In addition, when the separation between the plates is large, the volume of the reservoir greatly affects the reproducibility in the volume of the dispensed droplets, creating "reliability regimes." We conclude that droplet dispensing exhibits superior reliability as inter-plate device spacing is decreased, and the daughter droplet volume is most consistent when the reservoir volume matches that of the reservoir electrode.  相似文献   

15.
In this study, a novel droplet based microfluidic method for the generation of different sized droplet interface bilayers is reported. A microfluidic platform was designed, which allows the generation and packing of picoliter lipid coated water droplets. Droplets were generated by hydrodynamic focusing coupled with selective transport along grooves according to their size. A trapping structure at the end of the groove and a fine control of the flow pressures allowed for the droplets to be successfully trapped and aligned on demand. This technology facilitates the fine control of droplet size production as well as the generation of extended networks from a variety of lipids including 1,2-diphytanoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine in linear and non-linear configurations, which is vital to the application of Droplet Interface Bilayers to biological network construction on-chip.  相似文献   

16.
We present a novel method of generating and retrieving droplets stored in microfluidic grooves or cavity structures. First we designed and fabricated polydimethylsiloxane microchannels with grooves on the walls and then produced a two-phase flow of oil and aqueous phases to form aqueous phase droplets in an oil state. We propose the following three mechanisms of droplet generation: the contact line on the groove wall continues moving along the wall and descends to the bottom of the cavity, confining the aqueous phase in the cavity; once the interface between the oil and aqueous phases moves into the cavity, the interface contacts the top of the neighboring groove; and a spherical droplet forms at the corner in the cavity due to surface tension. The viscosity of the oil phase and the surface tension of the interface determine whether a droplet can be generated. Then, we could adjust the velocity of the interface and the aspect ratio of the cavity to achieve the optimal conditions for generating the single droplet. We observed that the largest droplet is stably generated without a daughter droplet at typical values of free-stream velocity (10 μl∕min) and groove pitch 110 μm for all three cases with different oil phases (20, 50, and 84 cP). This technique is expected to serve as a platform for droplet-based reaction systems, particularly with regard to monitoring cell behavior, in vitro expression, and possibly even micropolymerase chain reaction chambers.  相似文献   

17.
In a droplet transport based on electrowetting on dielectrics, the parallel-plate configuration is more popular than the single-plate one because the droplet transport becomes increasingly difficult without cover plate. In spite of the improved transport performance, the parallel-plate configuration often limits the access to the peripheral components, requesting the removal of the cover plate, the single-plate configuration. We investigated the fundamental features of droplet transport for the single-plate configuration. We compared the performance of several switching methods with respect to maximum speed of successive transport without failure and suggested nonfloating switching method which is inherently free from the charge-residue problem and exerts greater force on a droplet than conventional switching methods. A simple theory is provided to understand the different results for the switching methods.  相似文献   

18.
In this study, droplet formations in microfluidic double T-junctions (MFDTD) are investigated based on a two-dimensional numerical model with volume of fluid method. Parametric ranges for generating alternating droplet formation (ADF) are identified. A physical background responsible for the ADF is suggested by analyzing the dynamical stability of flow system. Since the phase discrepancy between dispersed flows is mainly caused by non-symmetrical breaking of merging droplet, merging regime becomes the alternating regime at appropriate conditions. In addition, the effects of channel geometries on droplet formation are studied in terms of relative channel width. The predicted results show that the ADF region is shifted toward lower capillary numbers when channel width ratio is less than unity. The alternating droplet size increases with the increase of channel width ratio. When this ratio reaches unity, alternating droplets can be formed at very high water fraction (wf = 0.8). The droplet formation in MFDTD depends significantly on the viscosity ratio, and the droplet size in ADF decreases with the increase of the viscosity ratio. The understanding of underlying physics of the ADF phenomenon is useful for many applications, including nanoparticle synthesis with different concentrations, hydrogel bead generation, and cell transplantation in biomedical therapy.  相似文献   

19.
We present a droplet-based microfluidic system for performing bioassays requiring controlled analyte encapsulation by employing highly flexible on-demand droplet generation. On-demand droplet generation and encapsulation are achieved pneumatically using a microdispensing pump connected to a constant pressure source. The system generates single droplets to the collection route only when the pump is actuated with a designated pressure level and produces two-phase parallel flow to the waste route during the stand-by state. We analyzed the effect of actuation pressure on the stability and size of droplets and optimized conditions for generation of stable droplets over a wide pressure range. By increasing the duration of pump actuation, we could either trigger a short train of identical size droplets or generate a single larger droplet. We also investigated the methodology to control droplet contents by fine-tuning flow rates or implementing a resistance bridge between the pump and main channels. We demonstrated the integrated chip for on-demand mixing between two aqueous phases in droplets and on-demand encapsulation of Escherichia coli cells. Our unique on-demand feature for selective encapsulation is particularly appropriate for bioassays with extremely dilute samples, such as pathogens in a clinical sample, since it can significantly reduce the number of empty droplets that impede droplet collection and subsequent data analysis.  相似文献   

20.
A novel technique for biomolecular detection in microliter droplets floating on the surface of high density oil is presented. Each droplet was captured and manipulated dielectrophoretically and was used as a site for a microscopic bioassay based on agglutination of antibody-conjugated particles. The results were read out by the pattern of unagglomerated gold nanoparticles collected on the droplet surface. Two formats of bioassays, namely gold only agglutination and gold and latex agglutination, were investigated experimentally by varying analyte concentration, particle size and concentration, number of antigen binding sites per particle, time for incubation, and rate of particle collection on the droplet surface. The microbioassays performance was also evaluated with ricin antibodies and compared to the ricin assays in field use. It is estimated that the droplet based assays require 100× smaller sample volume and are ten times more sensitive, though they require longer times to complete. The experiments were interpreted by modeling the kinetics of particle agglutination and mass transfer processes inside the droplets. The incubation time and antigen concentration values calculated by the model correlate well with the experimental results. The results could allow for development of efficient immunoassays on a chip requiring even smaller sample volumes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号