首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We investigated whether heart rate (HR)-derived parameters are accurate performance predictors in endurance recreational runners. One hundred thirty recreational athletes completed an incremental running test (4´running + 1´rest). After each stage, we recorded HR, % of maximum HR (%HRmax), and blood lactate. We also assessed HR after each recovery period, and calculated lactate and HR recovery thresholds and HR deflection point. We tested these parameters for associations with running performance, as measured by peak treadmill speed (PTS) and personal best International Association of Athletics Federations (IAAF) score. The %HRmax at 14.5 km·h?1 correlated with PTS (r = ?0.92), and IAAF score (rho = ?0.80). The magnitudes of the correlations of lactate-related parameters with PTS (|r| = 0.84 to 0.86) or IAAF score (|rho| = 0.70 to 0.77) in absolute values were slightly lower. The correlations detected between other HR-derived parameters and running performance were weaker (|r or rho| = 0.24 to 0.70). Regression models identified %HRmax at 14.5 km·h?1 as the strongest predictor of both PTS (β = ?0.72) and IAAF score (β = ?0.72). Consequently, tests based on %HRmax may provide a non-invasive and inexpensive alternate method for predicting the performance of these athletes.  相似文献   

2.
ABSTRACT

Heart rate (HR), when combined with accelerometry, can dramatically improve estimates of energy expenditure and sleep. Advancements in technology, via the development and introduction of small, low-cost photoplethysmography devices embedded within wrist-worn consumer wearables, have made the collection of heart rate (HR) under free-living conditions more feasible. This systematic review and meta-analysis compared the validity of wrist-worn HR estimates to a criterion measure of HR (electrocardiography ECG or chest strap). Searches of PubMed/Medline, Web of Science, EBSCOhost, PsycINFO, and EMBASE resulted in a total of 44 articles representing 738 effect sizes across 15 different brands. Multi-level random effects meta-analyses resulted in a small mean difference (beats per min, bpm) of ?0.40 bpm (95 confidence interval (CI) ?1.64 to 0.83) during sleep, ?0.01 bpm (?0.02 to 0.00) during rest, ?0.51 bpm (?1.60 to 0.58) during treadmill activities (walking to running), while the mean difference was larger during resistance training (?7.26 bpm, ?10.46 to ?4.07) and cycling (?4.55 bpm, ?7.24 to ?1.87). Mean difference increased by 3 bpm (2.5 to 3.5) per 10 bpm increase of HR for resistance training. Wrist-worn devices that measure HR demonstrate acceptable validity compared to a criterion measure of HR for most common activities.  相似文献   

3.
Abstract

The ActiGraph activity monitors have developed and newer versions of the ActiGraph accelerometers (GT1M, GT3X and GT3X +) are now available, including changes in hardware and software compared to the old version (AM7164). This is problematic as most of the validation and calibration work includes the AM7164. The aims of the study were to validate the ActiGraph GT1M during level and graded walking and to assess the potential underestimation of physical activity during cycling. Data were obtained from 20 participants during treadmill walking and ergometer cycling. Energy expenditure was measured via indirect calorimetry and used as the criterion method. Activity counts were highly correlated with energy expenditure during level walking (R2 = 0.82) and graded walking at 5% and 8% (R2 = 0.82 and R2 = 0.67, respectively). There was no linear relationship between activity counts and energy expenditure during cycling. The average activity counts for all data points during cycling was 1,157 counts per minute (CPM) (SD = 974), and mean energy expenditure was 5.0 metabolic equivalents. The GT1M is a valid tool for assessing walking across a wide range of speeds and gradients. However, there is no relationship between activity counts and energy expenditure during cycling and physical activity is underestimated by ≈73% during cycling compared to walking.  相似文献   

4.
Excess body weight composes an important limitation to exercise in obese youth. The aim of this study was to compare the perceived exertion of obese adolescents between weight-bearing (WB; running) and non-weight-Bearing (NWB; cycling) exercises performed at moderate (55%VO2max) and high (75%VO2max) intensities. Twenty-four obese adolescents were recruited. After assessment of their body composition and physical capacities, they had to complete four isoenergetic exercise sessions: (1) a cycling session performed at 55% of their maximal capacities (NWB-55%); (2) a cycling session set at 75% (NWB-75%); (3) a running session at 55% (WB-55%); and (4) a running session at 75% (WB-75%). Perceived exertion was assessed using a visual scale at regular interval. While no significant difference between WB and NWB modalities was observed, the adolescents expressed a significantly lower rate of perceived exertion (RPE) during exercises at 55%VO2max (P < 0.0001). An intensity × modality interaction revealed that RPE was lower at 75% VO2max during NWB exercises (P < 0.05). While obese adolescents expressed lower RPE during exercise at moderate intensity whatever its modality, low level of perceived exertion has been observed during high-intensity exercises and especially during NWB. High-intensity exercise appears well tolerated in adolescents when their body weight is supported.  相似文献   

5.
Abstract

We examined differences in anthropometry and training between 64 Triple Iron ultra-triathletes competing over 11.4 km swimming, 540 km cycling, and 126.6 km running, and 71 Ironman triathletes competing over 3.8 km swimming, 180 km cycling, and 42.2 km running. The association of anthropometry and training with race time was investigated using multiple linear regression analysis. The Triple Iron ultra-triathletes were smaller (P < 0.05), had shorter limbs (P < 0.05), a higher body mass index (P < 0.05), and larger limb circumferences (P < 0.01) than the Ironman triathletes. The Triple Iron ultra-triathletes trained for more hours (P < 0.01) and covered more kilometres (P < 0.01), but speed in running during training was slower compared with the Ironman triathletes (P < 0.01). For Triple Iron ultra-triathletes, percent body fat (P = 0.022), training volume per week (P < 0.0001), and weekly kilometres in both cycling (P < 0.0001) and running (P < 0.0001) were related to race time. For Ironman triathletes, percent body fat (P < 0.0001), circumference of upper arm (P = 0.006), and speed in cycling training (P = 0.012) were associated with total race time. We conclude that both Triple Iron ultra-triathletes and Ironman triathletes appeared to profit from low body fat. Triple Iron ultra-triathletes relied more on training volume in cycling and running, whereas speed in cycling training was related to race time in Ironman triathletes.  相似文献   

6.
The purpose of this study was to examine the validity of a highly popular pedometer application (Samsung Health). Sixteen adults (28.8 ± 8.9 years of age) wore two Samsung smartphone models, Samsung Galaxy Core Prime (SGCP) and Samsung Galaxy S4 (SGS4), at three body locations (waist, arm, and hand) while walking and running over a 50-m test. All trials were recorded using a video as a gold standard measure of step counts. Results indicated that the validity of Samsung Health varied depending on the smartphone model, its body location, and the type of gait (walking and running). Samsung Health showed acceptable validity when the SGCP was located on the hand (Bias = ?8.3%; RMSE = 5.6), and especially on the arm (Bias = ?7.2%; RMSE = 4.9) while running, and when the SGS4 was located on the arm (Bias = ?7.5%; RMSE = 5.4), and especially on the waist (Bias = 5.4%; RMSE = 3.7) while walking. Samsung Health only showed good validity when the SGS4 was located on the arm (Bias = 2.9%; RMSE = 3.6), and especially on the hand (Bias = 0.5%; RMSE = 2.5) while running. This application showed unacceptable validity in the remaining options.  相似文献   

7.
This study aimed to investigate whether treadmill versus overground soccer match simulations have similar effects on knee joint mechanics during side cutting. Nineteen male recreational soccer players completed a 45-min treadmill and overground match simulation. Heart rate (HR) and rating of perceived exertion (RPE) were recorded every 5 min. Prior to exercise (time 0 min), at “half-time” (time 45 min) and 15 min post-exercise (time 60 min), participants performed five trials of 45° side-cutting manoeuvres. Knee abduction moments and knee extension angles were analysed using two-way repeated measures analysis of variance (α = 0.05). Physiological responses were significantly greater during the overground (HR 160 ± 7 beats ? min?1; RPE 15 ± 2) than the treadmill simulation (HR 142 ± 5 beats ? min?1; RPE 12 ± 2). Knee extension angles significantly increased over time and were more extended at time 60 min compared with time 0 min and time 45 min. No significant differences in knee abduction moments were observed. Although knee abduction moments were not altered over time during both simulations, passive rest during half-time induced changes in knee angles that may have implications for anterior cruciate ligament injury risk.  相似文献   

8.
Little is known about the reliability, validity and smallest detectable differences of selected kinetic and temporal variables recorded by the Zebris FDM-THQ instrumented treadmill especially during running. Twenty male participants (age = 31.9 years (±5.6), height = 1.81 m (±0.08), mass = 80.2 kg (±9.5), body mass index = 24.53 kg/m2 (±2.53)) walked (5 km/h) and ran (10 and 15 km/h) on an instrumented treadmill, wearing running shoes fitted with Pedar-X insoles. A test-double retest protocol was conducted over two consecutive days. Maximal vertical force (Fmax), contact time (CT) and flight time (FT) data from 10 consecutive steps were collected. Within- and between-day reliability, smallest detectable differences (SDD) and validity (95% limits of agreement (LOA)) were calculated. ICC values for the Zebris for Fmax were acceptable (ICC ≥ 0.7) while CT and FT reliability indices were predominantly good (ICC ≥ 0.8) to excellent (ICC ≥ 0.9). The Zebris significantly underestimated Fmax when compared with the Pedar-X. The 95% LOA increased with speed. SDD ranged between 96 N and 169 N for Fmax, 0.017s and 0.055s for CT and 0.021s and 0.026s for FT. In conclusion, Zebris reliability was acceptable to excellent for the variables examined, but inferior in comparison with Pedar-X. With increased running speeds, a bias effect (underestimation) existed for the Zebris compared with Pedar-X.  相似文献   

9.
Abstract

In this study, we examined the effects of different work:rest durations during 20 min intermittent treadmill running and subsequent performance. Nine males (mean age 25.8 years, s = 6.8; body mass 73.9 kg, s = 8.8; stature 1.75 m, s = 0.05; [Vdot]O2max 55.5 ml · kg?1 · min?1, s = 5.8) undertook repeated sprints at 120% of the speed at which [Vdot]O2max was attained interspersed with passive recovery. The work:rest ratio was constant (1:1.5) with trials involving either short (6:9 s) or long (24:36 s) work:rest exercise protocols (total exercise time 8 min). Each trial was followed by a performance run to volitional exhaustion at the same running speed. Testing order was randomized and counterbalanced. Heart rate, oxygen consumption, respiratory exchange ratio, and blood glucose were similar between trials (P > 0.05). Blood lactate concentration was greater during the long than the short exercise protocol (P < 0.05), whereas blood pH was lower during the long than the short exercise protocol (7.28, s = 0.11 and 7.30, s = 0.03 at 20 min, respectively; P < 0.05). Perceptions of effort were greater throughout exercise for the long than the short exercise protocol (16.6, s = 1.4 and 15.1, s = 1.6 at 20 min, respectively; P < 0.05) and correlated with blood lactate (r = 0.43) and bicarbonate concentrations (r = ?0.59; P < 0.05). Although blood lactate concentration at 20 min was related to performance time (r = ?0.56; P < 0.05), no differences were observed between trials for time to exhaustion (short exercise protocol: 95.8 s, s = 30.0; long exercise protocol: 92.0 s, s = 37.1) or physiological responses at exhaustion (P > 0.05). Our results demonstrate that 20 min of intermittent exercise involving a long work:rest duration elicits greater metabolic and perceptual strain than intermittent exercise undertaken with a short work:rest duration but does not affect subsequent run time to exhaustion.  相似文献   

10.
Vibration in cycling has been proved to have undesirable effects over health, comfort and performance of the rider. In this study, 15 participants performed eight 6-min sub-maximal pedalling exercises at a constant power output (150W) and pedalling cadence (80 RPM) being exposed to vibration at different frequencies (20, 30, 40, 50, 60, 70 Hz) or without vibration. Oxygen uptake (VO2), heart rate (HR), surface EMG activity of seven lower limb muscles (GMax, RF, BF, VM, GAS, SOL and TA) and 3-dimentional accelerations at ankle, knee and hip were measured during the exercises. To analyse the dynamic response, the influence of the pedalling movement was taken into account. The results show that there was not significant influence of vibrations on HR and VO2 during this pedalling exercise. However, muscular activity presents a significant increase with the presence of vibration that is influenced by the frequency, but this increase was very low (< 1%). Also, the dynamic response shows an influence of the frequency as well as an influence of the different parts of the pedalling cycle. Those results help to explain the effects of vibration on the human body and the influence of the rider/bike interaction in those effects.  相似文献   

11.
Purpose: The purpose of this study was to determine the reliability of cardiorespiratory and pelvic kinematic responses to simulated horseback riding (SHBR) and to characterize responses to SHBR relative to walking in apparently healthy children. Method: Fifteen healthy children (Mage = 9.5 ± 2.6 years) completed SHBR on a commercially available simulator at low intensity (0.27 Hz) and high intensity (0.65 Hz) during 3 sessions on different occasions. Heart rate (HR), blood pressure, and respiratory gases were measured at rest and during steady-state exercise at both intensities. Pelvic displacement was measured during steady-state exercise. Rate of energy expenditure, mean arterial pressure, and rate pressure product (RPP) were calculated. Participants also walked on a treadmill for 26.8 m/min to 80.5 m/min in 13.4-m/min increments at 0% grade during 1 session to compare cardiorespiratory responses with those of SHBR. Results: Physiological variables across all 3 SHBR sessions were similar at both intensities (p>.05 for all). Intraclass correlation coefficients (ICCs) and coefficients of variation indicate good to modest reliability of cardiorespiratory measures during SHBR (ICCs = .542–.996 for oxygen consumption, energy expenditure, and RPP). Cardiorespiratory variables, except for HR, were 2% to 19% greater, and pelvic displacement was up to 37% greater with high-intensity riding. Treadmill walking at all speeds elicited greater physiological responses compared with SHBR (p < .05). Conclusion: Cardiorespiratory responses and pelvic kinematics are reproducible with SHBR in young children, and these responses were lower than those elicited by slow treadmill walking.  相似文献   

12.
Abstract

The bradycardia effect of a 10-week jogging program was studied in 13 previously sedentary middle-aged subjects (seven women and six men). This response during standardized submaximal treadmill walking and leg cycling was related to changes in cardiac output ([Qdot]), stroke volume (SV), and arteriovenous oxygen differences (a-vO2 diff). Heart rate (HR) response was also studied during load carrying and arm cycling tasks, and a [Vdot]O2 max test was administered. All tests were repeated posttraining. The posttraining increases in [Vdot]O2 max (ml/kg × min-1) were 19.7% and 14.8% for the men and women respectively. Training also produced significant reductions in submaximal HR and Q during treadmill and leg cycling exercise. A-vO2 diff rose, while there were no changes in [Vdot]O2 during the submaximal work tasks, suggesting either altered blood flow or a greater capacity to utilize O2 by the working muscle. Both men and women showed significant reductions in HR during the arm cycling and load carrying as well. These data suggest that a jogging program can alter cardiovascular function in tasks other than running. The magnitude and direction of change showed no sex differences; therefore, it was also concluded that there are no differences in the trainability of previously sedentary middle-aged men and women.  相似文献   

13.
The aim of the present study was to determine maximal oxygen uptake (VO2max) directly during uphill walking exercise and to compare these values with those achieved during running and cycling exercise. Forty untrained students (20 males and 20 females) took part in three exercise tests. The running test was performed on a horizontal treadmill and the speed was gradually increased by 0.3 m . s(-1) every 3 min. The walking test was conducted on a treadmill inclined at 12% (speed of 1.8 m . s(-1)). The load was further increased every 3 min by the addition of a mass of one-twentieth of the body mass of the participant (plastic containers filled with water and added to a backpack carried by the participant). During the bicycle ergometry test, the workload was increased by 20 W every 2 min. All tests were performed until volitional exhaustion. During all tests, oxygen uptake, minute ventilation, tidal volume, respiratory frequency, heart rate, hydrogen ion concentration, base excess, and blood lactate concentration were analysed. The Pearson correlation coefficients between the weighted walking test and the commonly applied running and bicycle ergometry tests indicate a strong association with the new test in evaluating maximal oxygen uptake. The negligible differences in VO2max between the three tests for the male participants (running: 61.0 ml . kg(-1) . min(-1); walking: 60.4 ml . kg(-1) . min(-1); cycling: 60.2 ml . kg(-1) . min(-1)), and the fact that the females achieved better results on the walking test than the cycle ergometer test (running: 45.0 ml . kg(-1) . min(-1); walking: 42.6 ml . kg(-1) . min(-1); cycling: 40.1 ml . kg(-1) . min(-1)), confirm the suitability of the new method for evaluating aerobic power. The weighted walking test could be useful in the assessment of aerobic power in individuals for whom running is not advised or is difficult. In addition, the new test allows for determination of VO2max on small treadmills with a limited speed regulator, such as those found in specialist physiotherapy and fitness centres.  相似文献   

14.
Abstract

Ghrelin is a hormone that stimulates hunger. Intense exercise has been shown to temporarily suppress hunger after exercise. In the present study, we investigated whether post-exercise hunger suppression is mediated by reduced plasma total ghrelin concentrations. Nine men and nine women participated in the study. Their mean physical characteristics were as follows: age 24.8 (s x  = 0.9) years, body mass index 22.9 (s x  = 0.6) kg · m?2, maximal oxygen uptake ([Vdot]O2max) 57.7 (s x  = 2.2) ml · kg?1 · min?1. The participants completed two 3-h trials (exercise and control) on separate days in a randomized balanced design after overnight fasts. The exercise trial involved a 1-h treadmill run at 73.5% of [Vdot]O2max followed by 2 h of rest. The control trial consisted of 3 h of rest. Blood samples were collected at 0, 0.5, 1, 1.5, 2, and 3 h. Total ghrelin concentrations were determined from plasma. Hunger was assessed following blood sampling using a 15-point scale. The data were analysed using repeated-measures analysis of variance. Hunger scores were lower in the exercise trial than in the control trial (trial, P = 0.009; time, P < 0.001; trial × time, P < 0.001). Plasma total ghrelin concentrations did not differ between trials. These findings indicate that treadmill running suppresses hunger but this effect is not mediated by changes in plasma total ghrelin concentration.  相似文献   

15.
The aims of the study were to describe the physiological profile of a 65-km (4000-m cumulative elevation gain) running mountain ultra-marathon (MUM) and to identify predictors of MUM performance. Twenty-three amateur trail-runners performed anthropometric evaluations and an uphill graded exercise test (GXT) for VO2max, ventilatory thresholds (VTs), power outputs (PMax, PVTs) and heart rate response (HRmax, HR@VTs). Heart rate (HR) was monitored during the race and intensity was expressed as: Zone I (VT2) for exercise load calculation (training impulse, TRIMP). Mean race intensity was 77.1%±4.4% of HRmax distributed as: 85.7%±19.4% Zone I, 13.9%±18.6% Zone II, 0.4%±0.9% Zone III. Exercise load was 766±110 TRIMP units. Race time (11.8±1.6h) was negatively correlated with VO2max (r = ?0.66, <0.001) and PMax (r = ?0.73, <0.001), resulting these variables determinant in predicting MUM performance, whereas exercise thresholds did not improve performance prediction. Laboratory variables explained only 59% of race time variance, underlining the multi-factorial character of MUM performance. Our results support the idea that VT1 represents a boundary of tolerable intensity in this kind of events, where exercise load is extremely high. This information can be helpful in identifying optimal pacing strategies to complete such extremely demanding MUMs.  相似文献   

16.
The treadmill is an attractive device for the investigation of human locomotion, yet the extent to which lower limb kinematics differ from overground running remains a controversial topic. This study aimed to provide an extensive three-dimensional kinematic comparison of the lower extremities during overground and treadmill running. Twelve participants ran at 4.0 m/s ( ± 5%) in both treadmill and overground conditions. Angular kinematic parameters of the lower extremities during the stance phase were collected at 250 Hz using an eight-camera motion analysis system. Hip, knee, and ankle joint kinematics were quantified in the sagittal, coronal, and transverse planes, and contrasted using paired t-tests. Of the analysed parameters hip flexion at footstrike and ankle excursion to peak angle were found to be significantly reduced during treadmill running by 12° (p = 0.001) and 6.6° (p = 0.010), respectively. Treadmill running was found to be associated with significantly greater peak ankle eversion (by 6.3°, p = 0.006). It was concluded that the mechanics of treadmill running cannot be generalized to overground running.  相似文献   

17.
We investigated the association between changes in vastii electromyography (EMG) and knee extensor fatigue during high-intensity cycling, and the subsequent effect on lower-limb power and intermuscular coordination during all-out cycling. On two separate days, participants completed 30-s all-out cycling or 10-min of high-intensity cycling followed by 30-s all-out cycling. EMG for gluteus maximus (GMAX), rectus femoris (RF), vastii (VAS), hamstrings (HAM) and gastrocnemius (GAS); co-activation for GMAX/RF, VAS/HAM and VAS/GAS; isometric maximal voluntary force (IMVF) and resting twitch (RT) of the knee extensors were measured. VAS EMG increases during high-intensity cycling (6% to 14%, P < 0.05) were negatively correlated (r = ?0.791, P < 0.05) with knee extensor IMVF decreases (?2% to?36%, P < 0.05) following the exercise. Knee extensor IMVF decreases were positively correlated (r = 0.757, P < 0.05) with all-out cycling power reductions (0% to ?27%, P < 0.05). VAS/GAS co-activation did not change (P > 0.05) during all-out cycling while VAS and GAS EMG decreased. Larger increase in VAS EMG during high-intensity cycling was associated with greater knee extensor fatigue and larger power reduction during all-out cycling. High VAS/GAS co-activation potentially limited power reduction induced by knee extensor fatigue during all-out cycling.  相似文献   

18.
Purpose: Correlations between fatigue-induced changes in exercise performance and maximal rate of heart rate (HR) increase (rHRI) may be affected by exercise intensity during assessment. This study evaluated the sensitivity of rHRI for tracking performance when assessed at varying exercise intensities. Method: Performance (time to complete a 5-km treadmill time-trial [5TTT]) and rHRI were assessed in 15 male runners following 1 week of light training, 2 weeks of heavy training (HT), and a 10-day taper (T). Maximal rate of HR increase (measured in bpm·s?1) was the first derivative maximum of a sigmoidal curve fit to HR data recorded during 5 min of running at 8 km·h?1 (rHRI8km·h?1), and during subsequent transition to 13 km·h?1 (rHRI8–13km·h?1) for a further 5 min. Results: Time to complete a 5-km treadmill time-trial was likely slower following HT (effect size ± 90% confidence interval = 0.16 ± 0.06), and almost certainly faster following T (–0.34 ± 0.08). Maximal rate of HR increase during 5 min of running at 8 km·h?1 and rHRI8–13km·h?1 were unchanged following HT and likely increased following T (0.77 ± 0.45 and 0.66 ± 0.62, respectively). A moderate within-individual correlation was found between 5TTT and rHRI8km·h?1 (r value ± 90% confidence interval = –.35 ± .32). However, in a subgroup of athletes (= 7) who were almost certainly slower to complete the 5TTT (4.22 ± 0.88), larger correlations were found between the 5TTT and rHRI8km·h?1 (r = –.84 ± .22) and rHRI8–13km·h?1 (r = –.52 ± .41). Steady-state HR during rHRI assessment in this group was very likely greater than in the faster subgroup (≥ 1.34 ± 0.86). Conclusion(s): The 5TTT performance was tracked by both rHRI8km·h?1 and rHRI8–13km·h?1. Correlations between rHRI and performance were stronger in a subgroup of athletes who exhibited a slower 5TTT. Individualized workloads during rHRI assessment may be required to account for varying levels of physical conditioning.  相似文献   

19.
Abstract

The assessment of nutrition and activity in athletes requires accurate and precise methods. The aim of this study was to validate a protocol for parallel assessment of diet and exercise against doubly labelled water, 24-h urea excretion, and respiratory gas exchange. The participants were 14 male triathletes under normal training conditions. Energy intake and doubly labelled water were weakly associated with each other (r = 0.69, standard error of estimate [SEE] = 304 kcal · day?1). Protein intake was strongly correlated with 24-h urea (r = 0.89) but showed considerable individual variation (SEE = 0.34 g · kg?1 · day?1). Total energy expenditure based on recorded activities was highly correlated with doubly labelled water (r = 0.95, SEE = 195 kcal · day?1) but was proportionally biased. During running and cycling, estimated exercise energy expenditure was highly correlated with gas exchange (running: r = 0.89, SEE = 1.6 kcal · min?1; cycling: r = 0.95, SEE = 1.4 kcal · min?1). High exercise energy expenditure was slightly underestimated during running. For nutrition data, variations appear too large for precise measurements in individual athletes, which is a common problem of dietary assessment methods. Despite the high correlations of total energy expenditure and exercise energy expenditure with reference methods, a correction for systematic errors is necessary for the valid estimation of energetic requirements in individual athletes.  相似文献   

20.
This study investigated the effects of aerobic exercise, fluid loss and rehydration on cognitive performance in well-trained athletes. Ten endurance-trained males (25 ± 5 years; 175 ± 5 cm; 70.35 ± 5.46 kg; VO2max, 62.95 ± 7.20 ml · kg.min?1) lost ~2.5 ± 0.6% body mass via continuous cycling exercise at ~65% peak sustainable power output (60 min duration) before consuming different beverages (Water = W1 and W2, Sustagen Sport = SS, Powerade = PD) and food ad libitum on four separate occasions. Cognitive function using a four-choice reaction time task (CRT), body mass, fluid consumption volumes, urine samples and subjective ratings (alertness, concentration, energy) were obtained before and after exercise, and hourly during recovery (for 4 h). CRT latency was significantly reduced immediately after exercise compared to pre-exercise measures for all trials (W1 = ?16 ± 18 ms, W2 = ?22 ± 21 ms, PD = ?22 ± 22 ms, SS = ?19 ± 26 ms). However, this effect was short-lived with subsequent measures not different from pre-exercise values. No difference in CRT accuracy was observed at any time across all trials. Subjective ratings were not different at any time across all trials. Aerobic exercise, hypohydration or an interaction between these two may provide a small cognitive performance benefit. However, these effects are temporary and confined to the immediate post-exercise period.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号