首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
2.
ABSTRACT

While foot orthoses are commonly used in running, little is known regarding biomechanical risk potentials during uphill running. This study investigated the effects of arch-support orthoses on kinetic and kinematic variables when running at different inclinations. Sixteen male participants ran at different inclinations (0°, 3° and 6°) when wearing arch-support and flat orthoses on an instrumented treadmill. Arch-support orthoses induced longer contact time, larger initial ankle dorsiflexion, maximum ankle eversion, and knee sagittal range of motion (RoM) (p < 0.05). As incline slopes increased, vertical impact peak and loading rate, stride length, and ankle coronal RoM decreased, but contact time, stride frequency, initial ankle dorsiflexion and inversion, maximum dorsiflexion, initial knee flexion, and ankle sagittal RoM increased (p < 0.05). Furthermore, knee sagittal RoM was lowest when running at an inclination of 3°. The interaction effect indicated that in arch-support condition, participants running at 6° induced higher maximum ankle eversion than running at 0° (p < 0.05), while no differences were found in flat orthosis condition. These findings suggest that the use of arch-support orthoses would influence running biomechanics that is related to injury risks. Running at higher inclination led to more alterations to biomechanical variables than at lower inclination.  相似文献   

3.
This study aimed to evaluate the test–retest reliability of a new device for assessing ankle joint kinesthesia. This device could measure the passive motion threshold of four ankle joint movements, namely plantarflexion, dorsiflexion, inversion and eversion. A total of 21 healthy adults, including 13 males and 8 females, participated in the study. Each participant completed two sessions on two separate days with 1-week interval. The sessions were administered by the same experimenter in the same laboratory. At least 12 trials (three successful trials in each of the four directions) were performed in each session. The mean values in each direction were calculated and analysed. The ICC values of test–retest reliability ranged from 0.737 (dorsiflexion) to 0.935 (eversion), whereas the SEM values ranged from 0.21° (plantarflexion) to 0.52° (inversion). The Bland–Altman plots showed that the reliability of plantarflexion–dorsiflexion was better than that of inversion–eversion. The results evaluated the reliability of the new device as fair to excellent. The new device for assessing kinesthesia could be used to examine the ankle joint kinesthesia.  相似文献   

4.
PurposeThe purpose of this study was to examine effects of a sport version of a semi-rigid ankle brace (Element?) and a soft ankle brace (ASO) on ankle biomechanics and ground reaction forces (GRFs) during a drop landing activity in subjects with chronic ankle instability (CAI) compared to healthy subjects with no history of CAI.MethodsTen healthy subjects and 10 subjects who had multiple ankle sprains participated in the study as the control and unstable subjects, respectively. The CAI subjects were age, body mass index and gender matched with the control subjects. The arch index and ankle functions of the subjects were measured in a subject screening session. During the biomechanical test session, participants performed five trials of drop landing from 0.6 m, wearing no brace (NB), Element? brace and ASO brace. Simultaneous recording of three-dimensional kinematic (240 Hz) and GRF (1200 Hz) data were performed.ResultsThe CAI subjects had lower ankle functional survey scores. The arch index and deformity results showed greater arch deformity of Element? against a static load than in NB and ASO due to greater initial arch position held by the brace. CAI participants had greater eversion velocity than healthy controls. The ASO brace reduced the first peak vertical GRF whereas Element? increased 2nd peak vertical GRF. Element? brace reduced eversion range of motion (ROM) and peak eversion velocity compared to NB and ASO. In addition, Element? reduced dorsiflexion ROM and increased peak plantarflexion moment compared to NB and ASO.ConclusionResults of static arch measurements and dynamic ankle motion suggest that the restrictions offered by both braces are in part due to more dorsiflexed ankle positions at contact, and higher initial arch position and stiffer ankle for Element?.  相似文献   

5.
The purpose of this investigation was to analyze the validity and reliability of an iPhone app (named: Dorsiflex) for the measurement of weight-bearing ankle dorsiflexion. To do this, twelve healthy participants (age=28.6±2.3 years) performed a weight-bearing lunge test with each leg in five separate occasions, while dorsiflexion angle was simultaneously registered using a professional digital inclinometer and the Dorsiflex iPhone app, which was specifically developed for this study. A total of 120 angles measured both with the digital inclinometer and the app were then compared for validity, reliability and accuracy purposes using several statistical tests. There was an almost perfect correlation between the digital inclinometer and the Dorsiflex app for the measurement of ankle dorsiflexion (r=0.989, 95% CI=0.986-0.993, SEE=0.48º), with trivial, non-significant differences between devices (SMD=0.17, p=0.10). When analyzing the reliability of the app for the measurement of five different trials for each participant, similar coefficients of variation (CV) were observed in comparison with those obtained with the digital inclinometer (Dorsiflex app: CV=5.1±2.3 %; Digital inclinometer: CV=4.9±2.5 %). The results of the present study show that weight-bearing ankle dorsiflexion can be easily, accurately, and reliably evaluated using the Dorsiflex iPhone app.  相似文献   

6.
研究背景:现有研究文献尚无有关在着地过程中不同表面倾斜度和踝关节护具效应的运动学、动力学和地面反作用力的综合数据。通过对比25°斜面和平面的着地以及使用和不使用踝关节护具情况下来检测踝关节的生物力学特性。研究方法: 11名健康受试者[年龄:(24.6±3.5)岁,身高:(24.6±0.10)m,质量:(65.6±14.9)kg)参与本次研究。受试者在4个动态运动条件下各进行5五次实验:从0.45米高处垂直下落至25°的斜面(IS)或平面(FS)上,使用或不使用半刚性踝关节护具,同时采集三维运动学和测力台地面反作用力数据。利用2×2(表面X踝关节护具)的重复测量方差分析来评估选定的变量。研究结果:与平面着地相比,斜面着地造成较小的垂直和内侧地面反作用力峰值。研究还发现踝关节背曲运动范围、着地角度和背曲速度、最大外翻与跖曲角速度提高,但产生了更大内翻角度和运动范围、着地内翻速度和最大跖曲力矩。踝关节护具在斜面着地时减少了达到地面反作用力第二垂直峰值的时间、着地角度、背曲速度、最大外翻和跖曲速度,但增加了跖曲力矩的最大值。研究结论:斜面增加踝关节额状面的运动范围和踝关节负荷。但是,就斜面着地而言,踝关节护具对踝关节额状面的运动范围和踝关节负荷的影响是相当有限的。  相似文献   

7.
The purpose of this study was to examine the effects of varying amounts of dynamic stretching (DS) on joint range of motion (ROM) and stiffness of the muscle–tendon unit (MTU). Fifteen healthy participants participated in four randomly ordered experimental trials, which involved one (DS1), four (DS4) and seven (DS7) sets of DS, or control conditions/seated at rest (CON). Each DS set consisted of 15 repetitions of an ankle dorsiflexion–plantarflexion movement. The displacement of the muscle–tendon junction (MTJ) was measured using ultrasonography while the ankle was passively dorsiflexed at 0.0174 rad · s?1 to its maximal dorsiflexion angle. Passive torque was also measured using an isokinetic dynamometer. Ankle ROM was significantly increased after DS4 and DS7 compared with the pre-intervention values (P < 0.05), but there were no significant differences in ankle ROM between DS4 and DS7. No differences were observed in ankle ROM after DS1 and CON. In addition, the stiffness of the MTU, passive torque and displacement of the MTJ at submaximal dorsiflexion angles did not change in any of the experimental conditions. These results indicate that DS4 increased ankle ROM without changing the mechanical properties of the MTU, and that this increase in ankle ROM plateaued after DS4.  相似文献   

8.
The purpose of this study was to examine the impact of age on running mechanics separately for male and female runners and to quantify sex differences in running mechanics and coordination variability for older runners. Kinematics and kinetics were captured for 20 younger (10 male) and 20 older (10 male) adults running overground at 3.5 m · s?1. A modified vector coding technique was used to calculate segment coordination variability. Lower extremity joint angles, moments and segment coordination variability were compared between age and sex groups. Significant sex–age interaction effects were found for heel-strike hip flexion and ankle in/eversion angles and peak ankle dorsiflexion angle. In older adults, mid-stance knee flexion angle, ankle inversion and abduction moments and hip abduction and external rotation moments differed by sex. Older compared with younger females had reduced coordination variability in the thigh–shank transverse plane couple but greater coordination variability for the shank rotation–foot eversion couple in early stance. These results suggest there may be a non-equivalent aging process in the movement mechanics for males and females. The age and sex differences in running mechanics and coordination variability highlight the need for sex-based analyses for future studies examining injury risk with age.  相似文献   

9.
Abstract

The purpose of this study was to investigate changes in ankle joint stiffness and the associated changes in the gastrocnemius muscle and tendon due to static stretching. Seven healthy male participants lay supine with the hip and knee joints fully extended. The right ankle joint was rotated into dorsiflexion from a 30° plantar flexed position and the torque measured by a dynamometer. The ankle joint was maintained in a dorsiflexed position for 20 min (static stretching of the calf muscles). We performed surface electromyography of the medial and lateral gastrocnemii, the soleus, and the tibialis anterior of the right leg to confirm no muscle activity throughout static stretching and the passive test (passive dorsiflexion). During static stretching, the ankle joint angle and elongation of the gastrocnemius were recorded by goniometry and ultrasonography, respectively. Tendon elongation of the gastrocnemius was calculated based on the changes in the ankle joint angle and muscle elongation. In addition, the relationships between passive torques and ankle joint angles, and elongation of muscle and tendon, were examined before and after static stretching. The ankle dorsiflexion angle and tendon elongation increased significantly by 10 min after the onset of static stretching, while there was no further increase in muscle length. In addition, ankle dorsiflexion angle and tendon elongation at an identical passive torque (30 N · m) increased significantly (from 24±7° to 33±5° and from 17±2 mm to 22±1 mm, respectively) after static stretching. However, muscle elongation was unchanged. In conclusion, the current results suggest that an increase in the ankle joint dorsiflexion angle due to static stretching is attributable to a change in tendon not muscle stiffness.  相似文献   

10.
An articulated boot design is commonly used in skiing and skating sports because it allows sagittal plane ankle mobility while still providing critical frontal plane stability. Although articulated boots have been in use for several decades, current manufacturers of these boots differ in their articulation placement. In this study we determined an optimal position of the ankle articulation axis. We also calculated the amount of anterior skin movement that a boot tongue must account for during a full range of ankle motion. Three-dimensional kinematic data were collected and analyzed from 40 participants moving their right foot through a full range of sagittal plane motion. The calculated horizontal position of the articulation axis was found to be highly predictable from foot length (r = 0.87, standard error of estimate = 3.44 mm), while its vertical component displayed less predictability (r = 0.49, standard error of estimate = 7.46 mm). The expansion required by the boot tongue had a moderate association with foot length and low variability (r = 0.58, standard error of estimate = 0.07 mm). An accurate axis placement will minimize relative motion between the boot cuff and the ankle, reducing friction and motion resistance. An expandable tongue will accommodate full plantar flexion and reduce pressure on the anterior ankle during dorsiflexion, eliminating common pressure-related injuries.  相似文献   

11.
Skiing‐Skating     
An articulated boot design is commonly used in skiing and skating sports because it allows sagittal plane ankle mobility while still providing critical frontal plane stability. Although articulated boots have been in use for several decades, current manufacturers of these boots differ in their articulation placement. In this study we determined an optimal position of the ankle articulation axis. We also calculated the amount of anterior skin movement that a boot tongue must account for during a full range of ankle motion. Three‐dimensional kinematic data were collected and analyzed from 40 participants moving their right foot through a full range of sagittal plane motion. The calculated horizontal position of the articulation axis was found to be highly predictable from foot length (r = 0.87, standard error of estimate = 3.44 mm), while its vertical component displayed less predictability (r = 0.49, standard error of estimate = 7.46 mm). The expansion required by the boot tongue had a moderate association with foot length and low variability (r = 0.58, standard error of estimate = 0.07 mm). An accurate axis placement will minimize relative motion between the boot cuff and the ankle, reducing friction and motion resistance. An expandable tongue will accommodate full plantar flexion and reduce pressure on the anterior ankle during dorsiflexion, eliminating common pressure‐related injuries.  相似文献   

12.
Abstract

The aim of this study was to test the correlation between knee-to-hip flexion ratio during a single leg landing task and hip and knee strength, and ankle range of motion. Twenty-four male participants from a professional soccer team performed a continuous single leg jump-landing test during 10s, while lower limb kinematics data were collected using a motion analysis system. After biomechanical testing, maximal isometric hip (abduction, extension, external rotation), knee extension and flexion strength were measured. Maximum ankle dorsiflexion range of motion was assessed statically using the weight bearing lunge test. Pearson correlation coefficients were calculated to determine the associations between the predictor variables (knee and hip strength, and ankle ROM) and the main outcome measure (knee-to-hip flexion ratio). Correlation between knee-to-hip flexion ratio and hip abductors strength was significant (r = ?0.47; p = 0.019). No other significant correlations were observed among the variables (p > 0.05). These results demonstrated that a lower hip abductors strength in male soccer players was correlated with a high knee-to-hip flexion ratio during landing from a single leg jump, potentially increasing knee overload by decreasing energy absorption at the hip. The results provide a novel proposal for the functioning of hip muscles to control knee overload.  相似文献   

13.
ABSTRACT

Running-related injuries have been associated with excessive foot pronation and high vertical loading rates. Traditional plaster-molded (TPM) foot orthoses are commonly prescribed to minimize these atypical biomechanical patterns. Recently, 3D printed (3DP) orthoses have become popular, yet the functional difference between these two types of orthoses remains unknown. Therefore, this study compared running biomechanics and perceived comfort during treadmill running in three orthotic conditions: 3DP orthoses, TPM orthoses, and a no-orthoses control condition (CON). Thirteen female asymptomatic runners with excessive foot pronation were recruited. Rearfoot eversion angle and velocity (at initial contact and peak) during stance, vertical loading rates, and perceived comfort were compared. Results showed lower peak rearfoot eversion angles during running with TPM (p=0.001, d=0.38) or 3DP orthoses (p=0.002, d=0.24) than CON. No differences were observed in other biomechanical parameters among the three conditions (p>0.05). Running with TPM (p≤0.001, d=1.74–1.82) and 3DP orthoses (p<0.003, d=1.06–1.34) resulted in better perceived comfort in “medial-lateral control” and “heel cushioning” than CON. There were no statistical differences in all parameters between TPM and 3DP orthoses. The present findings indicate improved comfort during running with TPM or 3DP orthoses, which hinted 3DP orthoses could be a viable alternative to TPM orthoses for clinical practice.  相似文献   

14.
The purpose of this study was to investigate kinematic and spatiotemporal variables of aquatic treadmill walking at three different water depths. A total of 15 healthy individuals completed three two-minute walking trials at three different water depths. The aquatic treadmill walking was conducted at waist-depth, chest-depth and neck-depth, while a customised 3-D underwater motion analysis system captured their walking. Each participant’s self-selected walking speed at the waist level was used as a reference speed, which was applied to the remaining two test conditions. A repeated measures ANOVA showed statistically significant differences among the three walking conditions in stride length, cadence, peak hip extension, hip range of motion (ROM), peak ankle plantar flexion and ankle ROM (All p values < 0.05). The participants walked with increased stride length and decreased cadence during neck level as compared to waist and chest level. They also showed increased ankle ROM and decreased hip ROM as the water depth rose from waist and chest to the neck level. However, our study found no significant difference between waist and chest level water in all variables. Hydrodynamics, such as buoyancy and drag force, in response to changes in water depths, can affect gait patterns during aquatic treadmill walking.  相似文献   

15.
Cardan/Euler and helical angles are the popular methods of quantifying angular kinematics. Cardan angles are sequence dependent and crosstalk can influence the kinematic calculations. The International Society of Biomechanics (ISB) recommends a sagittal, coronal, and then transverse (XYZ) sequence of rotations, although it has been proposed that when calculating rotations outside of the sagittal plane, this may not be the most appropriate method. This study investigated the influence of the helical and six available Cardan sequences on three-dimensional (3D) ankle joint kinematics. Kinematic data were obtained using an eight-camera motion analysis system as participants ran at 4.0 m/s ± 5%. Repeated measures ANOVAs were used to compare kinematic parameters, and intra-class correlations were employed to identify evidence of crosstalk across planes. The results indicate that in the transverse and coronal planes, peak angle and range of motion values using the YXZ and ZXY sequences were significantly greater than the other sequences. Furthermore, utilization of YXZ and ZXY sequences was associated with the strongest correlations from the sagittal plane, and the XYZ sequence was found to be associated with the lowest correlations. It appears that for the representation of 3D ankle joint kinematics, the XYZ sequence is associated with minimal planar crosstalk and as such its use is encouraged.  相似文献   

16.
Large impact loading with abnormal muscle activity and motion patterns may contribute to lower extremity injuries in ballet dancers. Yet, few studies investigated the influence of injury on the ballet movement. The purpose of this study was to find the neuromuscular and biomechanical characteristics in dancers with and without ankle injury during a jump-landing Sissonne Fermée task. Twenty-two ballet dancers were recruited and divided into the injured group (n = 11) and the uninjured group (n = 11). They performed a ballet movement called "Sissonne Fermée" with reflective markers and electrodes attached to their lower extremities. Ground reaction force, joint kinematics, and muscle activity were measured. The injured dancers had greater peak ankle eversion but smaller hindfoot-to-tibial eversion angles. Also, the injured dancers had greater activity of the hamstring of the dominant leg and tibialis anterior of the non-dominant leg during the pre-landing phase. The injured dancers had greater tibialis anterior activity of the dominant leg but less muscle activity in the medial gastrocnemius of the non-dominant leg during the post-landing phase. The injured dancers had a greater co-contraction index in the non-dominant ankle and a lower loading rate. The higher co-contraction indices showed that the injured dancers required more muscle effort to control ankle stability. Furthermore, the injured dancers used a "load avoidance strategy" to protect themselves from re-injury. Neuromuscular control training of the ankle joint for ballet dancers to prevent injury is necessary.  相似文献   

17.
Running on side-sloped surfaces is a common obstacle in the environment; however, how and to what extent the lower extremity kinematics adapt is not well known. The purpose of this study was to determine the effects of side-sloped surfaces on three-dimensional kinematics of hip, knee, and ankle during stance phase of running. Ten healthy adult males ran barefoot along an inclinable runway in level (0°) and side-sloped (10° up-slope and down-slope inclinations, respectively) configurations. Right hip, knee, and ankle angles along with their time of occurrence were analysed using repeated measures MANOVA. Up-slope hip was more adducted (p = 0.015) and internally rotated (p = 0.030). Knee had greater external rotations during side-sloped running at heel-strike (p = 0.005), while at toe-off, it rotated externally and internally during up-slope and down-slope running, respectively (p = 0.001). Down-slope ankle had greatest plantar flexion (p = 0.001). Up-slope ankle had greatest eversion compared with down-slope (p = 0.043), while it was more externally rotated (p = 0.030). These motion patterns are necessary to adjust the lower extremity length during side-sloped running. Timing differences in the kinematic events of hip adduction and external rotation, and ankle eversion were observed (p = 0.006). Knowledge on these alterations is a valuable tool in adopting strategies to enhance performance while preventing injury.  相似文献   

18.
Ballerinas use their ankle joints more extremely and sustain injuries on the ankle joint more frequently than non-dancers. Therefore, the ankle movement of dancers is important and should be studied to prevent injuries. Measuring ankle joint range of motion (ROM) using radiographs could demonstrate the contribution to motion of each joint. The aim of this study was to analyse and compare ankle joint movements and the ratio of each joint’s contribution during movement between dancers and non-dancers, using radiographic images. Dancers have lower dorsiflexion (26.7 ± 6.2°), higher plantarflexion (74.3 ± 7.1°) and higher total (101.1 ± 10.8°) ROMs than non-dancers (33.9 ± 7.0°, 57.2 ± 6.8° and 91.1 ± 9.3°, respectively) (p < 0.05). Although the ROMs were different between the two groups, the ratios of each joint movement were similar between these two groups, in all movements. Regarding total movement, the movement ratio of the talocrural joint was almost 70% and other joints accounted for almost 30% of the movement role in both dancers and non-dancers. Therefore, the differences in ROM between dancers and non-dancers were not a result of a specific joint movement but of all the relevant joints’ collaborative movement.  相似文献   

19.
This study determined the effects of simulated technique manipulations on early acceleration performance. A planar seven-segment angle-driven model was developed and quantitatively evaluated based on the agreement of its output to empirical data from an international-level male sprinter (100 m personal best = 10.28 s). The model was then applied to independently assess the effects of manipulating touchdown distance (horizontal distance between the foot and centre of mass) and range of ankle joint dorsiflexion during early stance on horizontal external power production during stance. The model matched the empirical data with a mean difference of 5.2%. When the foot was placed progressively further forward at touchdown, horizontal power production continually reduced. When the foot was placed further back, power production initially increased (a peak increase of 0.7% occurred at 0.02 m further back) but decreased as the foot continued to touchdown further back. When the range of dorsiflexion during early stance was reduced, exponential increases in performance were observed. Increasing negative touchdown distance directs the ground reaction force more horizontally; however, a limit to the associated performance benefit exists. Reducing dorsiflexion, which required achievable increases in the peak ankle plantar flexor moment, appears potentially beneficial for improving early acceleration performance.  相似文献   

20.
Abstract

External supports that reduce ankle joint mobility such as ski-boots can impair postural control of healthy participants. Although this disruptive effect has been attributed to the rigidity of the external supports, the results remained controversial and no study has been conducted in order to evaluate the influence of ski-boots rigidity. Hence, the question about the influence of ankle support rigidity on postural control remains open. This study was therefore undertaken in order to investigate the effect of ski-boots rigidity on postural control. Ten healthy active participants were recruited. The wearing of soft and rigid ski-boots was compared to barefoot while standing on a seesaw generating mediolateral and anteroposterior instability. Centre of pressure displacements were sampled with a force platform. The surface electromyographic activity of the main muscles from the leg, thigh and trunk was recorded. A motion analysis system was also used to calculate the ankle, knee and hip angles. The results did not reveal any negative influence of ski-boot rigidity on postural control but rather suggest a less active postural control with the rigid ski-boots which offered a higher mechanical contribution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号