1.

Introduction:

Zonulin is a eukaryotic protein structurally similar to Vibrio cholerae’s zonula occludens toxin. It plays an important role in the opening of small intestine tight junctions. The loss of gut wall integrity during sepsis might be pivotal and has been described in various experimental as well as human studies. Increased levels of zonulin could be demonstrated in diseases associated with increased intestinal inflammation, such as celiac disease and type 1 diabetes. We therefore investigated the role of plasma levels of zonulin in patients with sepsis as a non-invasive marker of gut wall integrity.

Materials and methods:

Plasma level of zonulin was measured in 25 patients with sepsis, severe sepsis or septic shock according to ACCP/SCCM criteria at the first day of diagnosed sepsis. 18 non-septic post-surgical ICU-patients and 20 healthy volunteers served as control. Plasma levels were determined by using commercially available ELISA kit. Data are given as median and interquartile range (IQR).

Results:

Significantly higher plasma concentration of zonulin were found in the sepsis group: 6.61 ng/mL (IQR 3.51–9.46), as compared to the to the post-surgical control group: 3.40 ng/mL (IQR 2.14–5.70) (P = 0.025), as well as to the healthy group: 3.55 ng/mL (IQR 3.14–4.14) (P = 0.008).

Conclusion:

We were able demonstrate elevated levels of plasma zonulin, a potential marker of intestinal permeability in septic patients. Increased zonulin may serve as an additional mechanism for the observed increased intestinal permeability during sepsis and SIRS.  相似文献   

2.

Introduction

Presepsin, the circulating soluble form of CD14 subtype (sCD14-ST) is a new emerging early marker for sepsis. Various cutoff levels of presepsin have been proposed, to discriminate between systemic bacterial and nonbacterial infectious diseases. The aim of this work was to define the reference interval for presepsin according to the CLSI C28-A3c approved guideline.

Materials and methods

Reference individuals (N = 200; 120 females) aged 18-75 years (median 39 years), free from inflammatory diseases, were selected for the study. Presepsin concentrations were measured by a commercially available chemiluminescent enzyme immunoassay (PATHFASTTM, Mitsubishi Chemical Europe GmbH, Düsseldorf, Germany). Reference limits were calculated using the non-parametric percentile method.

Results

Overall, the reference limits for the presepsin were 55–184 pg/mL (90% confidence intervals, CI, were 45 to 58 and 161 to 214, respectively). There were no significant differences between males and females and the presepsin concentrations were not even particularly influenced by age. The upper reference limit for the presepsin is much lower than every cut-off limit so far proposed, both for sepsis and also for systemic inflammatory response syndrome.

Conclusion

Specific decision levels are required to define the diagnostic and prognostic roles of presepsin in different settings of inflammatory and infectious diseases. Reference values can help to distinguish and quickly rule out healthy subjects or patients with other pathologies.Key words: CD14 Antigen, presepsin, reference values, male, female, Clinical and Laboratory Standard Institute  相似文献   

3.

Introduction:

Studies about vitamin D [25(OH)D] stability in plasma are limited and preanalytical variables such as tube type may affect results. We aimed to evaluate effect of storage conditions, sample type and some preanalytical variables on vitamin D concentration.

Materials and methods:

Blood samples from 15 healthy subjects were centrifuged at different temperatures and stored under different conditions. Serum and plasma 25(OH)D difference, effect of centrifugation temperature and common storage conditions were investigated.

Results:

There was no difference between serum and plasma vitamin D concentration. Centrifugation temperature had no impact on vitamin D concentration. 25(OH)D is stable under common storage conditions: 4 hours at room temperature, 24 hours at 2–8 °C, 7 days at −20 °C, 3 months at −80 °C.

Conclusion:

Vitamin D does not require any special storage conditions and refrigeration. Both serum and plasma can be used for measurement.  相似文献   

4.

Background

Early diagnosis is crucial for management of patients with suspected acute myocardial infarction (AMI). Among innovative and promising biomarkers, the recent interest raised on glycogen phosphorylase isoenzyme BB (GPBB) has prompted us to perform a meta-analysis of published studies.

Materials and methods:

A systematic electronic search was carried out on PubMed, Web of Science and Google Scholar, with no date restriction, to retrieve all articles that have investigated the early diagnostic performance of GPBB in patients with suspected AMI, and directly reported or allowed calculation of sensitivity and specificity. A meta-analysis of the reported sensitivity and specificity of each study and pooled area under the curve (AUC) was then performed by random effect approach. Heterogeneity was assessed by I-square statistics.

Results:

Eight studies were finally selected for analysis (941 subjects; 506 cases and 435 controls), with a high heterogeneity (I-squared, 86.3%). The resulting pooled estimates and 95% confidence interval were 0.854 (0.801–0.891) for sensitivity, 0.767 (0.713–0.815) for specificity, 0.826 (0.774–0.870) for negative predictive value, 0.802 (0.754–0.844) for positive predictive value, and 0.754 (0.602–0.907) for AUC. In those studies that have simultaneously assessed GPBB and a troponin immunoassay, the combination of these biomarkers did not significantly improve the performance of troponin alone.

Conclusion:

GPBB does not meet the current requirements for an efficient diagnosis of AMI when used as a stand-alone test, whereas its combination with troponin merits further investigation in larger trials.  相似文献   

5.

Background

The preanalytical phase represents the major source of variability in laboratory diagnostics. Our aim was to assess to what extent underfilling of primary blood tubes may impact upon routine coagulation testing.

Materials and methods:

Blood was drawn by syringe from 21 healthy volunteers and 6 patients on warfarin therapy, and immediately transferred into 3.6 mL vacuum tubes containing 3.2% sodium citrate (Terumo Europe N.V., Leuven, Belgium). All tubes were filled using standardized volumes of whole blood to produce scalar amounts of filling: 3.6 mL (i.e., 100%), 3.2 mL (89%), 2.8 mL (78%) and 2.4 mL (67%). Samples were mixed and centrifuged at 1300 × g for 10 min. The plasma was tested for prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FBG) on ACL TOP (Instrumentation Laboratory - IL, Milan, Italy), using IL reagents. A polynomial plot was derived for each parameter from interpolation of clotting values obtained with different percentages of filling, and these plots were compared with quality specifications (± 2.0 for PT, ± 2.3 for APTT and ± 4.8 for FBG) to calculate the minimal filling volume required to produce clinically acceptable results.

Results:

The equations were (PF, Percentage of filling): PT (sec) = 3.375 × PF^2–6.255 × PF + 17.806 (r = 0.980); APTT (sec) = 8.925 × PF^2–23.578 × PF + 46.356 (r = 0.979); and FBG (mg/dL) = −311.5 × PF^2 + 422.1 × PF + 147.07 (r = 0.994). According to these equations, the minimum allowed thresholds of blood tubes filling were > 61% for PT, > 87% for APTT and > 71% for FBG.

Conclusions:

Our results confirm that routine coagulation testing performed on underfilled tubes may generate biased and clinically misleading test results. This is particularly critical for APTT, wherein tubes filled at less than ∼90% generate unreliable data. The FBG and the PT seem more resistant to underfilling, clinical significant biases being observed only where blood tubes were filled at less than ∼60 and ∼70%, respectively.  相似文献   

6.

Background

In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.

Material and methods

Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.

Results

The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).

Conclusion

Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume  相似文献   

7.

Introduction

Vaspin (visceral adipose tissue-derived serpin) was first described as an insulin-sensitizing adipose tissue hormone. Recently its anti-inflammatory function has been demonstrated. Since no appropriate data is available yet, we sought to investigate the plasma concentrations of vaspin in sepsis.

Materials and methods

57 patients in intensive care, fulfilling the ACCP/SCCM criteria for sepsis, were prospectively included in our exploratory study. The control group consisted of 48 critically ill patients, receiving intensive care after trauma or major surgery. Patients were matched by age, sex, weight and existence of diabetes before statistical analysis. Blood samples were collected on the day of diagnosis. Vaspin plasma concentrations were measured using a commercially available enzyme-linked immunosorbent assay.

Results

Vaspin concentrations were significantly higher in septic patients compared to the control group (0.3 (0.1-0.4) ng/mL vs. 0.1 (0.0-0.3) ng/mL, respectively; P < 0.001). Vaspin concentration showed weak positive correlation with concentration of C-reactive protein (CRP) (r = 0.31, P = 0.002) as well as with SAPS II (r = 0.34, P = 0.002) and maximum of SOFA (r = 0.39, P < 0.001) scoring systems, as tested for the overall study population.

Conclusion

In the sepsis group, vaspin plasma concentration was about three-fold as high as in the median surgical control group. We demonstrated a weak positive correlation between vaspin and CRP concentration, as well as with two scoring systems commonly used in intensive care settings. Although there seems to be some connection between vaspin and inflammation, its role in human sepsis needs to be evaluated further.Key words: adipocytokine, inflammation, vaspin, CRP, intensive care  相似文献   

8.

Introduction:

Serum blood collection tubes with separator gel are widely used by many laboratories for chemistry analyses. We describe a case of a primary blood collection tube filled with blood sample and a floating separator gel.

Materials and methods:

The blood sample was collected from a 51 years old female in intensive care unit with the diagnosis of pneumonia into a BD Vacutainer SST tube (Becton Dickinson, NJ, USA) containing serum separator gel and conveyed to the core laboratory of Marmara University Hospital within 30 minutes from collection. Sample was immediately centrifuged at room temperature at 1500 × g for 10 minutes.

Results:

The analyses revealed a highly increased total protein concentration of 145 g/L (reference interval 64–83 g/L). The nephelometric analyses showed an elevated serum IgG concentration of 108 g/L (reference interval 6.5–16 g/L) and IgG lambda monoclonal band was determined by serum immunofixation electrophoresis.

Conclusion:

Limitation of the separator gel tubes in patients with a high plasma density and its possible effects on test results and laboratory costs should be remembered. The clinical diagnosis stated in the information system should also reveal known comorbid conditions besides the apparent admission reason. This information would avoid resampling, additional testing, and communication efforts with the clinicians.  相似文献   

9.

Introduction

Postmenopausal women have higher risk of cardiovascular disease. One of the contributing factors could be reduced activity of anti-atherogenic enzyme paraoxonase 1 (PON1). The aim of this study was to examine differences in the lipid status, paraoxonase and arylesterase PON1 activities and PON1 phenotype in women with regular menstrual cycle and in postmenopausal women.

Materials and methods:

The study included 51 women in reproductive age (25 in follicular and 26 in luteal phase of the menstrual cycle) and 23 women in postmenopause. Lipid parameters in sera were determined using original reagents and according to manufacturer protocol. PON1 activity in serum was assessed by spectrophotometric method with substrates: paraoxon and phenylacetate. PON1 phenotype was determined by double substrate method.

Results:

Compared to the women in follicular and luteal phase, postmenopausal women have significantly higher concentration of triglyceride [0.9 (0.7–1.3), 0.7 (0.6–1.0) vs. 1.5 (0.9–1.7) mmol/L; P = 0.002], cholesterol [5.10 (4.78–6.10), 5.05 (4.70–5.40) vs. 6.30 (5.73–7.23) mmol/L; P < 0.001], LDL [3.00 (2.56–3.63), 3.00 (2.70–3.70) vs. 3.90 (3.23–4.50) mmol/L; P < 0.001], and apolipoprotein B [0.88 (0.75–1.00), 0.79 (0.68–1.00) vs. 1.07 (0.90–1.24) mmol/L; P = 0.002]. PON1 basal [104 (66–260), 106 (63–250) vs. 93 (71–165) U/L; P = 0.847] and salt-stimulated paraoxonase activity [210 (131–462), 211 (120–442) vs. 180 (139–296) U/L; P = 0.857] as well as arylesterase activity [74 (63–82), 70 (54–91) vs. 70 (60–81) kU/L; P = 0.906] and PON1 phenotype (P = 0.810) were not different in the study groups.

Conclusion:

There are no differences in PON1 activity and PON1 phenotype between women with regular menstrual cycle and postmenopausal women.  相似文献   

10.

Introduction:

Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration.

Materials and methods:

Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot.

Results:

Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = −0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error.

Conclusion:

Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.  相似文献   

11.

Introduction

Measurements of blood ethanol concentrations must be accurate and reliable. The most important factors affecting blood ethanol stability are temperature and storage time. In this study, we aimed to compare ethanol stability in plasma samples at -20 °C for the different storage periods.

Materials and methods

Blood samples were collected from intoxicated drivers (N = 80) and initial plasma ethanol concentrations were measured immediately. Plasma samples were then stored at -20 °C and re-assessed after 2, 3, 4, or 5 months of storage. Differences between the initial and stored ethanol concentrations in each group (N = 20) were analyzed using Wilcoxon matched-pairs test. The deviation from the initial concentration was calculated and compared with Clinical Laboratory Improvement Amendments (CLIA’88) Proficiency Testing Limits. Relationships between the initial concentrations and deviations from initial concentrations were analyzed by Spearman’s correlation analysis. For all statistical tests, differences with P values of less than 0.05 were considered statistically significant.

Results

Statistically significant differences were observed between the initial and poststorage ethanol concentrations in the overall sample group (P < 0.001). However, for the individual storage duration groups, analytically significant decreases were observed only for samples stored for 5 months, deviations from the initial concentrations exceeded the allowable total error (TEa). Ethanol decreases in the other groups did not exceed the TEa.

Conclusion

According to our results, plasma ethanol samples can be kept at -20 °C for up to 3-4 months until re-analysis. However, each laboratory should also establish its own work-flow rules and criterion for reliable ethanol measurement in forensic cases.Key words: preanalytical phase, ethanol, stability, storage temperature  相似文献   

12.

Introduction

Acute kidney injury (AKI) is common in neonatal intensive care units (NICU). In recent years, every effort is made for early detection of AKI. Our hypothesis was that serum neutrophil gelatinase-associated lipocalin (sNGAL) may be a reliable screening test for early diagnosis of AKI in premature neonates after perinatal asphyxia. Therefore, our aim was to assess the diagnostic accuracy of sNGAL for AKI in premature asphyxiated neonates.

Materials and methods

AKI was defined in the third day of life (DOL 3) as a serum creatinine (sCr) increase ≥ 26.5 μmol/L from baseline (the lowest previous sCr). According to the increase of sCr, AKI patients were divided in AKIN1 (sCr increase up to 1.9 baseline) and AKIN2 (sCr increase from 2.0 to 2.9 baseline). sNGAL levels were measured on DOL 1, 3 and 7.

Results

AKI was diagnosed in 73 (0.676) of 108 enrolled premature asphyxiated neonates. Sixty one patients (0.836) were classified in AKIN1 and 12 patients (0.164) in AKIN2. sNGAL reached the maximal concentrations on DOL 1 within 4 hours after admission to NICU, being higher in AKI compared with no-AKI group (160.8 ± 113.1 vs. 87.1 ± 81.6; P < 0.001) as well as in AKIN2 compared with AKIN1 group (222.8 ± 112.9 vs. 147.8 ± 109.9; P < 0.001). The best areas under the receiver operating characteristic curves (AUC) for prediction of AKI were 0.72 [95% (0.62-0.80) P < 0.001] on DOL1 at 2h and 0.72 [95% (0.63-0.80) P < 0.001] at 4th hour after admission respectively. The corresponding sNGAL cutoff concentrations were 84.87 ng/mL (sensitivity 69.0% and specificity 71.9%) and 89.43 ng/mL (sensitivity 65.7% and specificity 74.3%).

Conclusions

In premature asphyxiated neonates sNGAL measured within the first 4 hours of DOL 1 is predictive of the occurrence and severity of AKI. Therefore, plasma levels of NGAL may be used for early diagnosis of AKI in these patients.Key words: serum neutrophil gelatinase-associated lipocalin, acute kidney injury, premature neonates, biomarker  相似文献   

13.

Introduction

The study of cardiac response to strenuous and continuous exercise is crucial to understanding the physiology of endurance. N-terminal proB-type natriuretic peptide (NT-proBNP) is a potential marker for monitoring myocardial wall stress, and troponins (TnT and TnI) are widely used in the diagnosis of cardiac ischemia and infarction. Strenuous exercise may generate transitory ischemia, myocardial stress, and diastolic left ventricular dysfunction, inducing the increased production of both these biomarkers. We measured changes in NT-proBNP and TnT in elite cyclists during a 3-week stage race, a model of strenuous exercise.

Materials and methods:

The study population was 9 professional cyclists participating in the 2011 Giro d’Italia. Pre-analytical and analytical phases scrupulously followed official recommendations. Anthropometric data, net energy expenditure and cardiac indexes (rate, diastolic and systolic blood pressure) were recorded. Blood samples were drawn pre-race (day −1) and at days 12 and 22; NT-proBNP and highly sensitive-troponin (Hs-TnT) concentrations were assayed and corrected for plasma volume changes.

Results:

Body-mass index decreased and energy expenditure increased by 52% during the race. NT-proBNP concentrations increased [day −1: 23.52 ng/L (9.67–34.33); day 12: 63.46 ng/L (22.15–93.31); P = 0.039; day 22: 89.26 ng/L (34.66–129.78) vs. day −1; P < 0.001] and correlated with heart rate (r = −0.51; P = 0.006), systolic pressure (r = 0.39; P = 0.046) and energy expenditure (r = 0.70; P < 0.001). TnT concentrations did not vary, but a widened TnT amplitude distribution was observed.

Conclusions:

Increases in NT-proBNP correlated with higher energy expenditure over a 3-week cycling stage race, possibly indicating myocardial stress.  相似文献   

14.

Introduction:

Two Italian adults arrived at the Emergency Department referring diarrhea, nausea and vomiting for 4 days; weakness, fatigue and visual hallucinations were also complained of. Patients reported the ingestion of some leaves of a plant, which they supposed to be “donkey ears”, a week before. Physical examination showed hypotension and bradycardia and ECG examination disclosed sinus rhythm and repolarization abnormalities (scooping of the ST-T complex) in both patients and a 2:1 AV block in the man.

Materials and methods:

Digoxin concentration was evaluated twice for each patient (at the admission and after 4 hours) by the automated immunoassay system ADVIA Centaur®. Digitoxin concentration was evaluated by liquid chromatography-mass spectrometry (LC-MS/MS).

Results:

Despite clinical picture was suggestive of digitalis intoxication, digoxin levels were undetectable. Due to the more severe clinical picture, the male patient was treated with anti-digoxin antibodies (Digifab®) achieving a good clinical improvement and remission of the AV block within two hours. Initial diagnosis was confirmed by LC-MS/MS showing high digitoxin concentrations, but digoxin was undetectable. Patients remained stable and 48 hours later were discharged from the hospital.

Conclusion:

Whereas digoxin determination frequently relies on monoclonal antibodies which do not cross-react to digitoxin, polyclonal antibodies constituting Digifab® recognize a large spectrum of cardiac glycosides, including digitoxin. This report emphasizes the primary role of the clinical approach to patients in the emergency setting and how an active communication and a continuous sharing of professional experiences between Laboratory and Clinicians ensure an early and correct diagnosis.  相似文献   

15.

Background:

Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests.

Materials and methods:

A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV).

Results:

A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104–117) and 111 (107–120) vs. 109 (102–118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9–34.8) vs. 34.1 (32.2–35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV.

Conclusion:

A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.  相似文献   

16.

Background:

Overcrowding and prolonged length of stay in emergency departments (ED) are increasing problems in hospitals. Rapid availability of all laboratory results has an impact on clinical decision-making, admissions or discharge decisions and resource utilisation. Increasing number of our urinary drugs of abuse (DOA) screens had a turnaround time (TAT) of up to 33 days after the discharge of the patient.

Materials and methods:

Following an audit and a consultation period with clinicians using the service, a policy change was implemented to reduce the use of gas chromatography mass spectroscopy (GCMS): all requests would have a standard immunoassay (IA) test panel undertaken unless specifically they requested GCMS (including medico-legal) analysis.

Results:

Almost all of the clinicians interviewed had no understanding of the DOA screening or the difference in the information generated between a confirmatory GCMS urine toxicology screen and IA DOA panel. It appeared none of the patients surveyed in the audit would have had a different clinical decision made if a GCMS had not been undertaken. Post change audit showed only 4.3% of drug requests for IA also received a confirmatory GCMS testing. The estimated saving post change implementation was $127,000 (AU $) in test costs alone over a two year period. The TAT of GCMS results was reduced to 3–4 days.

Conclusion:

A laboratory-led behavioural change in test requesting is possible and sustainable provided the reason is clinically sound and accompanied by consultation and availability of advice by phone when requested on test requesting or interpretation.  相似文献   

17.

Introduction

Centrifugation is an essential step for plasma preparation to remove residual elements in plasma, especially platelets and platelet-derived microparticles (PMPs). Our working hypothesis was that centrifugation as a preanalytical step may influence some coagulation parameters.

Materials and methods

Healthy young men were recruited (N = 17). For centrifugation, two protocols were applied: (A) the first centrifugation at 2500 x g for 15 min and (B) at 2500 x g for 20 min at room temperature with a light brake. In protocol (A), the second centrifugation was carried out at 2500 x g for 15 min, whereas in protocol (B), the second centrifugation involved a 10 min spin at 13,000 x g. Thrombin-antithrombin (TAT) and plasmin-antiplasmin (PAP) complexes concentrations were determined by enzyme-linked immunosorbent assays. PMPs were stained with CD41 antibody and annexin V, and analyzed by flow cytometry method. Procoagulant activity was assayed by the Calibrated Automated Thrombogram method as a slope of thrombin formation (CAT velocity).

Results

Median TAT and PAP concentrations did not differ between the centrifugation protocols. The high speed centrifugation reduced the median (IQR) PMP count in plasma from 1291 (841-1975) to 573 (391-1010) PMP/µL (P = 0.001), and CAT velocity from 2.01 (1.31-2.88) to 0.97 (0.82-1.73) nM/min (P = 0.049). Spearman’s rank correlation analysis showed correlation between TAT and PMPs in the protocol A plasma which was (rho = 0.52, P < 0.050) and between PMPs and CAT for protocol A (rho = 0.74, P < 0.050) and protocol B (rho = 0.78, P < 0.050).

Conclusion

Centrifugation protocols do not influence the markers of plasminogen (PAP) and thrombin (TAT) generation but they do affect the PMP count and procoagulant activity.Key words: cell-derived microparticles, blood coagulation tests, centrifugation, preanalytical phase  相似文献   

18.

Background:

A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis.

Materials and methods:

We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode.

Results:

Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40).

Conclusions:

Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration.  相似文献   

19.

Introduction

Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS).

Materials and methods

One hundred venous blood samples were randomly selected from routine vitamin D tests. Two of the serum aliquots were analyzed at the Abbott Architect i2000 and the Roche Cobas 6000’s module e601 in our laboratory within the same day. The other serum aliquots were analyzed at the LC-MS/MS in different laboratory. Passing-Bablok regression analysis and Bland-Altman plot were used to compare methods. Inter-rater agreement was analyzed using kappa (κ) analysis.

Results

The Roche assay showed acceptable agreement with the LC-MS/MS based on Passing-Bablok analysis (intercept: -5.23 nmol/L, 95% CI: -8.73 to 0.19; slope: 0.97, 95% CI: 0.77 to 1.15). The Abbott assay showed proportional (slope: 0.77, 95% CI: 0.67 to 0.85) and constant differences (intercept: 17.08 nmol/L; 95% CI: 12.98 to 21.39). A mean bias of 15.1% was observed for the Abbott and a mean bias of -14.1% was observed for the Roche based on the Bland-Altman plots. We found strong to nearly perfect agreement in vitamin D status between the immunoassays and LC-MS/MS. (κ: 0.83 for Abbott, κ: 0.93 for Roche) using kappa analysis.

Conclusion

Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.Key words: 25-Hydroxyvitamin D, chromatography, immunoassay, methods, tandem mass spectrometry  相似文献   

20.