首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Introduction

Acute kidney injury (AKI) is significant problem in children with congenital heart disease (CHD) who undergo cardiac surgery. The economic impact of a biomarker-based diagnostic strategy for AKI in pediatric populations undergoing CHD surgery is unknown. The aim of this study was to perform the cost effectiveness analysis of using serum cystatin C (sCysC), urine neutrophil gelatinase-associated lipocalin (uNGAL) and urine liver fatty acid-binding protein (uL-FABP) for the diagnosis of AKI in children after cardiac surgery compared with current diagnostic method (monitoring of serum creatinine (sCr) level).

Materials and methods

We developed a decision analytical model to estimate incremental cost-effectiveness of different biomarker-based diagnostic strategies compared to current diagnostic strategy. The Markov model was created to compare the lifetime cost associated with using of sCysC, uNGAL, uL-FABP with monitoring of sCr level for the diagnosis of AKI. The utility measurement included in the analysis was quality-adjusted life years (QALY). The results of the analysis are presented as the incremental cost-effectiveness ratio (ICER).

Results

Analysed biomarker-based diagnostic strategies for AKI were cost-effective compared to current diagnostic method. However, uNGAL and sCys C strategies yielded higher costs and lower effectiveness compared to uL-FABP strategy. uL-FABP added 1.43 QALY compared to current diagnostic method at an additional cost of $8521.87 per patient. Therefore, ICER for uL-FABP compared to sCr was $5959.35/QALY.

Conclusions

Our results suggest that the use of uL-FABP would represent cost effective strategy for early diagnosis of AKI in children after cardiac surgery.Key words: acute kidney injury, cardiac surgery, children, biomarkers, cost effectiveness analysis  相似文献   

2.

Introduction

Acute kidney injury (AKI) is common in neonatal intensive care units (NICU). In recent years, every effort is made for early detection of AKI. Our hypothesis was that serum neutrophil gelatinase-associated lipocalin (sNGAL) may be a reliable screening test for early diagnosis of AKI in premature neonates after perinatal asphyxia. Therefore, our aim was to assess the diagnostic accuracy of sNGAL for AKI in premature asphyxiated neonates.

Materials and methods

AKI was defined in the third day of life (DOL 3) as a serum creatinine (sCr) increase ≥ 26.5 μmol/L from baseline (the lowest previous sCr). According to the increase of sCr, AKI patients were divided in AKIN1 (sCr increase up to 1.9 baseline) and AKIN2 (sCr increase from 2.0 to 2.9 baseline). sNGAL levels were measured on DOL 1, 3 and 7.

Results

AKI was diagnosed in 73 (0.676) of 108 enrolled premature asphyxiated neonates. Sixty one patients (0.836) were classified in AKIN1 and 12 patients (0.164) in AKIN2. sNGAL reached the maximal concentrations on DOL 1 within 4 hours after admission to NICU, being higher in AKI compared with no-AKI group (160.8 ± 113.1 vs. 87.1 ± 81.6; P < 0.001) as well as in AKIN2 compared with AKIN1 group (222.8 ± 112.9 vs. 147.8 ± 109.9; P < 0.001). The best areas under the receiver operating characteristic curves (AUC) for prediction of AKI were 0.72 [95% (0.62-0.80) P < 0.001] on DOL1 at 2h and 0.72 [95% (0.63-0.80) P < 0.001] at 4th hour after admission respectively. The corresponding sNGAL cutoff concentrations were 84.87 ng/mL (sensitivity 69.0% and specificity 71.9%) and 89.43 ng/mL (sensitivity 65.7% and specificity 74.3%).

Conclusions

In premature asphyxiated neonates sNGAL measured within the first 4 hours of DOL 1 is predictive of the occurrence and severity of AKI. Therefore, plasma levels of NGAL may be used for early diagnosis of AKI in these patients.Key words: serum neutrophil gelatinase-associated lipocalin, acute kidney injury, premature neonates, biomarker  相似文献   

3.

Introduction:

The aim of this study was to investigate whether serum levels of interleukin-1β (IL–1β) has any possible correlation on inflammatory parameters such as C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and fibrinogen concentration in patients with familial Mediterranean fever (FMF) patients during attack-free period.

Materials and methods:

The serum levels of IL-1β, as an indicator of cytokines status, and the acute phase response proteins, CRP, ESR and fibrinogen levels were evaluated in 35 attack-free patients with FMF and 25 healthy volunteers.

Results:

Serum IL-1β levels were significantly higher in patients with FMF than control subjects (P = 0.018). There was no statistically significant difference in the serum levels of ESR, CRP and fibrinogen between two groups (P = 0.181, P = 0.816, P = 0.686, respectively). There was a significant correlation between IL-1β and CRP (r = 0.513, P = 0.002) values of FMF group.

Conclusions:

In conclusion, our results confirm the presence of increased IL-1β levels in FMF patients during attack-free period. Serum IL-1β values seems to correlate with CRP levels. The elevation of IL-1β levels may be important in monitoring subclinical inflammation of attack free period in FMF patients.  相似文献   

4.

Background

In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.

Material and methods

Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.

Results

The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).

Conclusion

Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume  相似文献   

5.

Introduction

Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures.

Materials and methods:

We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semi-quantitative urine culture.

Results:

Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8–65.3), and a negative predictive value (NPV) of 88.8% (95% Cl = 85.0–91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test.

Conclusions:

Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis results do not accurately predict the outcome of culture.  相似文献   

6.

Introduction:

There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values.

Materials and methods:

70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values.

Results:

First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed.

Conclusion:

We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.  相似文献   

7.

Introduction

The aim of this study was to identify clinical variables which may be independently associated with positivity of a cardiac troponin I (cTnI) assay in a large population of patients admitted to the emergency department (ED).

Materials and methods

3166 subjects, with at least two troponin I tests ordered within 6 hours in the ED, were studied. Patient data were statistically analyzed to identify clinical associations with increased values of Troponin I.

Results

Although patients with diagnosis of acute coronary syndrome displayed troponin I values significantly higher than those of other groups, positivity to troponin I (> 40 ng/L) was also observed in patients with other clinical conditions. In multivariate analysis, age, elevated heart rate and electrocardiographyc changes were independently associated with troponin I positivity at admission. In the whole study population troponin I positivity exhibited high sensitivity and negative predictive value, counterbalanced by low specificity and limited positive predictive value.

Conclusions

Troponin I positivity should be combined with history and clinical evaluation and cautiously interpreted in the ED, especially in patients exhibiting factors associated with higher troponin I levels such as older age, elevated heart rate or ECG changes.Key words: troponin I, acute coronary syndrome, emergency service, hospital, chest pain  相似文献   

8.

Introduction

Vaspin (visceral adipose tissue-derived serpin) was first described as an insulin-sensitizing adipose tissue hormone. Recently its anti-inflammatory function has been demonstrated. Since no appropriate data is available yet, we sought to investigate the plasma concentrations of vaspin in sepsis.

Materials and methods

57 patients in intensive care, fulfilling the ACCP/SCCM criteria for sepsis, were prospectively included in our exploratory study. The control group consisted of 48 critically ill patients, receiving intensive care after trauma or major surgery. Patients were matched by age, sex, weight and existence of diabetes before statistical analysis. Blood samples were collected on the day of diagnosis. Vaspin plasma concentrations were measured using a commercially available enzyme-linked immunosorbent assay.

Results

Vaspin concentrations were significantly higher in septic patients compared to the control group (0.3 (0.1-0.4) ng/mL vs. 0.1 (0.0-0.3) ng/mL, respectively; P < 0.001). Vaspin concentration showed weak positive correlation with concentration of C-reactive protein (CRP) (r = 0.31, P = 0.002) as well as with SAPS II (r = 0.34, P = 0.002) and maximum of SOFA (r = 0.39, P < 0.001) scoring systems, as tested for the overall study population.

Conclusion

In the sepsis group, vaspin plasma concentration was about three-fold as high as in the median surgical control group. We demonstrated a weak positive correlation between vaspin and CRP concentration, as well as with two scoring systems commonly used in intensive care settings. Although there seems to be some connection between vaspin and inflammation, its role in human sepsis needs to be evaluated further.Key words: adipocytokine, inflammation, vaspin, CRP, intensive care  相似文献   

9.

Introduction

Measurements of blood ethanol concentrations must be accurate and reliable. The most important factors affecting blood ethanol stability are temperature and storage time. In this study, we aimed to compare ethanol stability in plasma samples at -20 °C for the different storage periods.

Materials and methods

Blood samples were collected from intoxicated drivers (N = 80) and initial plasma ethanol concentrations were measured immediately. Plasma samples were then stored at -20 °C and re-assessed after 2, 3, 4, or 5 months of storage. Differences between the initial and stored ethanol concentrations in each group (N = 20) were analyzed using Wilcoxon matched-pairs test. The deviation from the initial concentration was calculated and compared with Clinical Laboratory Improvement Amendments (CLIA’88) Proficiency Testing Limits. Relationships between the initial concentrations and deviations from initial concentrations were analyzed by Spearman’s correlation analysis. For all statistical tests, differences with P values of less than 0.05 were considered statistically significant.

Results

Statistically significant differences were observed between the initial and poststorage ethanol concentrations in the overall sample group (P < 0.001). However, for the individual storage duration groups, analytically significant decreases were observed only for samples stored for 5 months, deviations from the initial concentrations exceeded the allowable total error (TEa). Ethanol decreases in the other groups did not exceed the TEa.

Conclusion

According to our results, plasma ethanol samples can be kept at -20 °C for up to 3-4 months until re-analysis. However, each laboratory should also establish its own work-flow rules and criterion for reliable ethanol measurement in forensic cases.Key words: preanalytical phase, ethanol, stability, storage temperature  相似文献   

10.

Introduction:

We present our work of monitoring 202 different patients with markedly elevated serum index for lipemia whereby serum samples were clear. We tried to clarify the cause of occurrence of these indices which were detected in the years 2006–2010 on Siemens Dimension analyzers.

Materials and methods:

In samples with unusual lipemia index we measured the concentration of lipids (total cholesterol, triglycerides, HDL and LDL cholesterol, Lp(a), ApoA1, ApoB), total proteins and checked for possible interferents (rheumatoid factor, immunoglobulins). We performed serum protein and immuno- electrophoresis. We investigated the repeatability of unusual lipemia indices during the day and after different time periods and we compared them on four different analyzers (RXL Max, Vista, Hitachi 911 and former Olympus AU640).

Results:

In 87% of 202 samples we found a monoclonal or biclonal peak in serum protein electrophoresis. Different types of paraproteins were confirmed with immunofixation electrophoresis. In the remaining 13%, polyclonal elevated concentrations of immunoglobulins were measured. Other parameters had no influence on appearing of these indices. The repeatability of indices was good during the first day of measurements (P values > 0.05) and markedly lower in the next days or after 3 and 12 months (P values < 0.05). The indices were elevated only on Dimension analyzers, but not on Hitachi and former Olympus analysers.

Conclusion:

A markedly elevated lipemia index in a clear serum sample measured on Siemens analyzers Dimension indicates a high possibility for the presence of a paraprotein in the sample.  相似文献   

11.
12.

Introduction:

Respiratory syncytial virus (RSV) infection is the most common cause of hospitalization in infants and small children. The aim was to present a 13-months old boy diagnosed with acute airway infection, acute otitis media (AOM) and hepatitis during the RSV-infection.

Material and methods:

Serum catalytic activities of alkaline phosphatase (ALP), aspartate aminotranspherase (AST), alanine aminotranspherase (ALT), gamma glutamyl transpherase (GGT), lactate dehydrogenase (LD), and concentrations of bilirubin were monitored during hospitalization and at control examination.

Results:

The child had clinical signs and symptoms of respiratory failure, AOM, and laboratory findings of virus infection and liver disease. On admission, catalytic activities of enzymes were markedly increased, especially the activity of ALP (10333 U/L, i.e. 24-fold increase in comparison with the upper reference limit). The highest increased in AST (339 U/L, 4.5-fold), ALT (475 U/L, 10.3-fold) and LD (545 U/L, 1.5-fold) were registered on the 3rd day, and the highest increase in GGT (68 U/L, 3.1-fold) occurred on the 11th day. Seven weeks after discharge AST, ALT, GGT and LD decreased into reference range, and ALP remain mildly increased (478 U/L, 1.1 fold increase). RSV was confirmed in nasal lavage fluid.

Conclusion:

Laboratory results in patient with RSV infection needs to be interpreted in the light of both, respiratory and extrapulmonary manifestations of the infection, respectively.  相似文献   

13.

Introduction

Presepsin, the circulating soluble form of CD14 subtype (sCD14-ST) is a new emerging early marker for sepsis. Various cutoff levels of presepsin have been proposed, to discriminate between systemic bacterial and nonbacterial infectious diseases. The aim of this work was to define the reference interval for presepsin according to the CLSI C28-A3c approved guideline.

Materials and methods

Reference individuals (N = 200; 120 females) aged 18-75 years (median 39 years), free from inflammatory diseases, were selected for the study. Presepsin concentrations were measured by a commercially available chemiluminescent enzyme immunoassay (PATHFASTTM, Mitsubishi Chemical Europe GmbH, Düsseldorf, Germany). Reference limits were calculated using the non-parametric percentile method.

Results

Overall, the reference limits for the presepsin were 55–184 pg/mL (90% confidence intervals, CI, were 45 to 58 and 161 to 214, respectively). There were no significant differences between males and females and the presepsin concentrations were not even particularly influenced by age. The upper reference limit for the presepsin is much lower than every cut-off limit so far proposed, both for sepsis and also for systemic inflammatory response syndrome.

Conclusion

Specific decision levels are required to define the diagnostic and prognostic roles of presepsin in different settings of inflammatory and infectious diseases. Reference values can help to distinguish and quickly rule out healthy subjects or patients with other pathologies.Key words: CD14 Antigen, presepsin, reference values, male, female, Clinical and Laboratory Standard Institute  相似文献   

14.

Introduction

Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia.

Materials and methods

An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions.

Results

The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein.

Conclusions

There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia.Key words: survey, chronic kidney disease, estimated glomerular filtration rate (eGFR), albuminuria, proteinuria, creatinine, harmonization  相似文献   

15.

Introduction:

Zonulin is a eukaryotic protein structurally similar to Vibrio cholerae’s zonula occludens toxin. It plays an important role in the opening of small intestine tight junctions. The loss of gut wall integrity during sepsis might be pivotal and has been described in various experimental as well as human studies. Increased levels of zonulin could be demonstrated in diseases associated with increased intestinal inflammation, such as celiac disease and type 1 diabetes. We therefore investigated the role of plasma levels of zonulin in patients with sepsis as a non-invasive marker of gut wall integrity.

Materials and methods:

Plasma level of zonulin was measured in 25 patients with sepsis, severe sepsis or septic shock according to ACCP/SCCM criteria at the first day of diagnosed sepsis. 18 non-septic post-surgical ICU-patients and 20 healthy volunteers served as control. Plasma levels were determined by using commercially available ELISA kit. Data are given as median and interquartile range (IQR).

Results:

Significantly higher plasma concentration of zonulin were found in the sepsis group: 6.61 ng/mL (IQR 3.51–9.46), as compared to the to the post-surgical control group: 3.40 ng/mL (IQR 2.14–5.70) (P = 0.025), as well as to the healthy group: 3.55 ng/mL (IQR 3.14–4.14) (P = 0.008).

Conclusion:

We were able demonstrate elevated levels of plasma zonulin, a potential marker of intestinal permeability in septic patients. Increased zonulin may serve as an additional mechanism for the observed increased intestinal permeability during sepsis and SIRS.  相似文献   

16.

Introduction

This pilot study aimed to investigate the use of personal protective equipment (PPE) and compliance to the code of conduct (rules defined in institutional, governmental and professional guidelines) among laboratory technicians in Croatian medical laboratories. In addition, we explored the differences in compliance between participants of different age groups, laboratory ownership and accreditation status.

Materials and methods

An anonymous and voluntary survey with 15 questions was conducted among Croatian medical laboratory technicians (N = 217). The questions were divided into two groups: demographic characteristics and the use of PPE. The questions of the second part were graded according to the Likert scale (1-4) and an overall score, shown as median and range (min-max), was calculated for each participant. Differences between the overall scores were tested for each group of participants.

Results

The majority of participants always wear protective clothes at work, 38.7% of them always wear gloves in daily routine, more than 30.0% consume food and almost half of them drink beverages at workplace. A significantly lower overall score was found for participants working in public compared to private laboratories (36 (16-40) vs. 40 (31-40), P < 0.001). There were no statistically significant differences in overall scores for participants of different age groups (P = 0.456) and laboratory accreditation status (P = 0.081).

Conclusion

A considerable percentage of laboratory technicians in Croatian medical laboratories do not comply with safety measures. Lack of compliance is observed in all personnel regardless laboratory accreditation and participants’ age. However, those working in private laboratories adhere more to the code of conduct.Key words: survey, compliance, laboratory technician, universal safety measures, total quality management, clinical laboratory services  相似文献   

17.

Introduction

Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS).

Materials and methods

One hundred venous blood samples were randomly selected from routine vitamin D tests. Two of the serum aliquots were analyzed at the Abbott Architect i2000 and the Roche Cobas 6000’s module e601 in our laboratory within the same day. The other serum aliquots were analyzed at the LC-MS/MS in different laboratory. Passing-Bablok regression analysis and Bland-Altman plot were used to compare methods. Inter-rater agreement was analyzed using kappa (κ) analysis.

Results

The Roche assay showed acceptable agreement with the LC-MS/MS based on Passing-Bablok analysis (intercept: -5.23 nmol/L, 95% CI: -8.73 to 0.19; slope: 0.97, 95% CI: 0.77 to 1.15). The Abbott assay showed proportional (slope: 0.77, 95% CI: 0.67 to 0.85) and constant differences (intercept: 17.08 nmol/L; 95% CI: 12.98 to 21.39). A mean bias of 15.1% was observed for the Abbott and a mean bias of -14.1% was observed for the Roche based on the Bland-Altman plots. We found strong to nearly perfect agreement in vitamin D status between the immunoassays and LC-MS/MS. (κ: 0.83 for Abbott, κ: 0.93 for Roche) using kappa analysis.

Conclusion

Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.Key words: 25-Hydroxyvitamin D, chromatography, immunoassay, methods, tandem mass spectrometry  相似文献   

18.

Background

Platelet satellitism is a phenomenon of unknown etiology of aggregating platelets around polymorphonuclear neutrophils and other blood cells which causes pseudothrombocytopenia, visible by microscopic examination of blood smears. It has been observed so far in about a hundred cases in the world.

Case subject and methods

Our case involves a 73-year-old female patient with a urinary infection. Biochemical serum analysis (CRP, glucose, AST, ALT, ALP, GGT, bilirubin, sodium, potassium, chloride, urea, creatinine) and blood cell count were performed with standard methods on autoanalyzers. Serum protein fractions were examined by electrophoresis and urinalysis with standard methods on autoanalyzer together with microscopic examination of urine sediment. Erythrocyte sedimentation rate, blood culture and urine culture tests were performed with standard methods.

Results

Due to typical pathological values for bacterial urinary infection, the patient was admitted to the hospital. Blood smear examination revealed phenomenon, which has persisted for three weeks after the disease has been cured. Blood smears with EDTA as an anticoagulant had platelet satellitism whereas the phenomenon was not observed in tubes with different anticoagulants (Na, Li-heparin) and capillary blood.

Discussion

We hypothesize that satellitism was induced by some immunological mechanism through formation of antibodies which have mediated platelets binding to neutrophil membranes and vice versa. Unfortunately we were unable to determine the putative trigger for this phenomenon. To our knowledge this is the second case of platelet satellitism ever described in Croatia.Key words: blood platelets, thrombocytopenia, EDTA, urinary infection  相似文献   

19.

Introduction:

This study aimed to assess whether heart fatty acid-binding protein (H-FABP) and glycogen phosphorylase isoenzyme BB (GPBB) could be used for the accurate diagnosis of acute myocardial infarction (AMI) in acute coronary syndrome (ACS) patients.

Materials and methods:

The study included 108 ACS patients admitted to a coronary unit within 3 h after chest pain onset. AMI was distinguished from unstable angina (UA) using a classical cardiac troponin I (cTnI) assay. H-FABP and GPBB were measured by ELISA on admission (0 h) and at 3, 6, 12, and 24 h after admission; their accuracy to diagnose AMI was assessed using statistical methods.

Results:

From 92 patients with ACS; 71 had AMI. H-FABP and GPBB had higher peak value after 3 h from admission than cTnI (P = 0.001). Both markers normalized at 24 h. The area under the receiver operating characteristic curves was significantly greater for both markers in AMI patients than in UA patients at all time points tested, including admission (P < 0.001). At admission, the H-FABP (37%) and GPBB (40%) sensitivities were relatively low. They increased at 3 and 6 h after admission for both markers and decreased again after 24 h. It was 40% for H-FABP and approximately 2-times lower for GPBB (P < 0.01). In AMI patients, both biomarkers had similar specificities, positive- and negative-predictive values, positive and negative likelihood ratios, and risk ratios for AIM.

Conclusion:

H-FABP and GPBB can contribute to early AMI diagnosis and can distinguish AMI from UA.  相似文献   

20.

Introduction

The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia.

Materials and methods:

Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%).

Results:

The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%.

Conclusion:

We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏