首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
The current management of intrauterine growth restriction (IUGR) being empirical and aimed at selecting a safe time for delivery. Acknowledging the beneficial effects of l-arginine on endothelial vasculature the present study was designed to evaluate efficacy of l-arginine on bioavailability of nitric oxide (NO) with respect to fetal outcome. With l-arginine supplementation, mean NO levels were significantly increased and a significant mild reduction in systolic/end-diastolic velocity ratio (S/D ratio) was observed on doppler blood flow study, also neonatal outcome improved and incidences of complications were lowered. A deficiency in NO may play an important role in the causation of asymmetric fetal growth restriction. l-Arginine can be used to increase maternal NO levels, enhancing birth weight and decreasing neonatal morbidity. The ideal candidate for arginine therapy according to our study would be IUGR cases with S/D ratio less than 4.96 ± 0.49 and NO levels below 33 μmol/L with minimum of 3 weeks duration of arginine supplementation.  相似文献   

2.
Methods for assaying lysosomal diseases in dried blood samples are very useful today due to its several advantages related to the stability of samples, its transportation, handled and analysis, and its potential use for newborn screening compared to traditional methods in leucocytes samples. For this reason, it is important to validate these assays before being used in routine laboratory. Because of different in biological markers based on ethnicity, we aimed this study to validation a DBS-based fluorometric assay for measurement of α-l-Iduronidase activity for diagnosis of MPS I patients in Iran. DBS samples were collected from 15 MPS I patients and 60 healthy age matched subjects. Diagnostic value, biological variance and α-l-Iduronidase activity were determined. DBS α-l-Iduronidase activity was significantly higher in male subjects than in female group. Using a cut-off level of 1.08 µmol/spot 20 h, sensitivity and specificity were 100 and 98 %. The linearity of test was proved and we showed that within-run and between run precision were 5.6 and 14.66 %. Measurement of α-l-Iduronidase activity in DBS samples is an accurate test for diagnosis of MPS I and because of its rapid shipping and simplicity to keeping, DBS-based enzyme activity could be considered as a useful diagnostic tool in this disease.  相似文献   

3.
The purpose of this study is optimizing the l-arginine (l-Arg) doses on the basis of chemical structure in regional accessible tumor therapy to settle down a new protocol for the treatment of cancer. 3H-thymidine-based cell proliferation assay was performed in vitro on tumor cell lines of fibrosarcoma (FS), lymphosarcoma-ascitic and on normal cell line of NIH 3T3 after treatment with different concentrations of l-Arg in phosphate buffered saline (PBS). The cultures were harvested after 22 h and the incorporated radioactivity was counted to identify their histologic grades as described in earlier studies. In vivo therapy of murine tumors was conducted where FS cells injected subcutaneously at ventro-lateral position of mice. Various drug delivery schedules were injected into the centre of tumor base, once a day for 4 days. Tumor diameter and survivals were monitored where the day of sacrifice was considered for monitoring the survival period. By identifying the histologic grades of the treated cultures in vitro and in vivo by different concentrations of l-Arg, the corresponding energy of such concentrations were determined. An efficient model with a good fit (R2 = 0.98) was established to describe the energy yield by l-Arg dose. The equivalence between the tumor histologic grade and energy of the l-Arg dose delivered in saline (PBS) environment is the optimum condition for regional tumor therapy achieves higher survival rate. The selective cytotoxicity to tumor cells with minimal damage to normal cells by l-Arg due to its chemical structure suggests to be considered the most promising drug for regional therapy of the accessible tumors like breast cancers of early stage with no distant metastasis.  相似文献   

4.
Nowadays, microfluidics is attracting more and more attentions in the biological society and has provided powerful solutions for various applications. This paper reported a microfluidic strategy for aqueous sample sterilization. A well-designed small microchannel with a high hydrodynamic resistance was used to function as an in-chip pressure regulator. The pressure in the upstream microchannel was thereby elevated which made it possible to maintain a boiling-free high temperature environment for aqueous sample sterilization. A 120 °C temperature along with a pressure of 400 kPa was successfully achieved inside the chip to sterilize aqueous samples with E. coli and Staphylococcus aureus inside. This technique will find wide applications in portable cell culturing, microsurgery in wild fields, and other related micro total analysis systems.Microfluidics, which confines fluid flow at microscale, attracts more and more attentions in the biological society.1–4 By scaling the flow domain down to microliter level, microfluidics shows attractive merits of low sample consumption, precise biological objective manipulation, and fast momentum/energy transportation. For example, various cell operations, such as culturing5–7 and sorting,8–10 have already been demonstrated with microfluidic approaches. In most biological applications, sterilization is a key sample pre-treatment step to avoid contamination. However, as far as the author knew, this important pre-treatment operation is generally achieved in an off-chip way, by using high temperature and high pressure autoclave. Actually, microfluidics has already been utilized to develop new solution for high pressure/temperature reactions. The required high pressure/temperature condition was generated either by combining off-chip back pressure regulator and hot-oil bath,11,12 or by integrating pressure regulator, heater, and temperature sensor into a single chip.13 This work presented a microfluidic sterilization strategy by implementing the previously developed continuous flowing high pressure/temperature microfluidic reactor.Figure Figure11 shows the working principle of the present microfluidic sterilization chip. The chip consists of three zones: sample loading (a microchannel with length of 270 mm and width of 40 μm), sterilization (length of 216 mm and width of 100 μm), and pressure regulating (length of 42 mm and width of 5 μm). Three functional zones were separated by two thermal isolation trenches. The sample was injected into the chip by a syringe pump and experienced two-step filtrations (feature sizes of 20 μm and 5 μm, not shown in Figure Figure1)1) at the entrance to avoid the channel clog. All channels had the same depth of 40 μm. According to the Hagen–Poiseuille relationship,15 the pressure regulating channel had a large flow resistance (around 1.09 × 1017 Pa·s/m3, see supplementary S1 for details16) because of its small width, thereby generated a high working pressure in the upstream sterilization channel under a given flow rate. The boiling point of the solution will then be raised up by the elevated pressure in the sterilization zone followed by the Antoine equation.16 By integrating heater/temperature sensors in the pressurized zone, a high temperature environment with temperature higher than 100 °C can thereby be realized for aqueous sample sterilization. The sample was collected from the outlet and cultured at 37 °C for 12 h. Bacterial colony was counted to evaluate the sterilization performance.Open in a separate windowFIG. 1.Working principle of the present microfluidic sterilization. Only microfluidic channel, heater, and temperature sensor were schematically shown. The varied colour of the microchannel represents the pressure and that of the halation stands for the temperature.Fabrication of this chip has been introduced elsewhere.14 The fabricated chip and the experimental system are shown in Figure Figure2.2. There were two inlets of the chip. While, in the experiment, only one inlet used and connected to the syringe pump. The backup one was blocked manually. The sample load zone was arranged in between of the sterilization zone and the pressure regulating zone based on thermal management consideration. A temperature control system (heater/temperature sensor, power source, and multi-meter) was setup to provide the required high temperature. The heater and the temperature sensor were microfabricated Pt resistors. The temperature coefficient of resistance (TCR) was measured as 0.00152 K−1.Open in a separate windowFIG. 2.The fabricated chip and the experimental system. (a) Two chips with a penny for comparison. The left chip was viewed from the heater/temperature sensor side, while the right one was observed from the microchannel side (through a glass substrate). (b) The experimental system.Thermal isolation performance of the present chip before packaging with inlet/outlet was shown in Figure Figure3,3, to show the thermal interference issue. The results indicated that when the sterilization zone was heated up to 140 °C, the pressure regulating zone was about 40 °C. At this temperature, the viscosity of water decreases to 0.653 mPa·s from 1.00 mPa·s (at 20 °C), which will make the pressure in the sterilization zone reduced from 539 kPa (calculated at 20 °C and flow rate of 4 nl/s) to 387 kPa. The boiling point will then decrease to 142.8 °C, which will guarantee a boiling-free sterilization. In the cases without the thermal isolation trenches, the temperature of the pressure regulating zone reached as high as 75 °C because of the thermal interference from the sterilization zone, as shown in Figure Figure3.3. The pressure in the sterilization zone was then reduced to 268 kPa (calculated at flow rate of 4 nl/s) and the boiling temperature was around 130 °C, which was lower than the set sterilization temperature. Detail calculation can be found in supplementary S2.16Open in a separate windowFIG. 3.The temperature distribution of the chips (before packaged) with and without thermal isolation trenches (powered at 1 W). The data were extracted from the central lines of infrared images, as shown as inserts.Bacterial sterilization performance of the present chip was tested and the experimental results were shown in Figure Figure4.4. E. coli with initial concentration of 106/ml was pumped into and flew through the chip with the sterilization temperatures varied from 25 °C to 120 °C at flow rates of 2 nl/s and 4 nl/s. The outflow was collected and inoculated onto the SS agar plate evenly with inoculation loops. The population of bacteria in the outflow was counted based on the bacterial colonies after incubation at 37 °C for 12 h. Typical bacterial colonies were shown in Figure Figure4.4. The low flow rate case showed a better sterilization performance because of the longer staying period in the sterilization channel. The population of E. coli was around 1.25 × 104/ml after a 432 s-long, 70 °C sterilization (at flow rate of 2 nl/s). While at the flow rate of 4 nl/s, the cultivation result indicated the population was around 3.8 × 104/ml because the sterilization time was shorten to 216 s. A control case, where the solution flew through an un-heated chip at 2 nl/s, was conducted to investigate the effect of the shear stress on the sterilization performance (see the supplementary S3 for details16). As listed in Table TableI,I, the results indicated that the shear stress did not show any noticeable effect on the bacterial sterilization. When the chip was not heated, i.e., the case with the largest shear stress because of the highest viscosity of fluid, the bacterial cultivation was nearly the same as the off-chip results (no stress). The temperature has the most significant effect on the sterilization performance. No noticeable bacteria proliferation was observed in the cases with the sterilization temperature higher than 100 °C, as shown in Figure Figure44.

Table I.

The E. coli cultivation results under different flow rates and sterilization temperatures. a
 25 °C70 °C100 °C120 °C25 °C b
2 nl/s1.89/+++1.38/+1.16/−1.04/−0/+++
4 nl/s3.78/+++2.76/+2.32/−2.08/−0/+++
Open in a separate windowaData in the table are shear stress (Pa)/population of bacteria, where “+++” indicates a large proliferation, “+” means small but noticeable proliferation, “−” represents no proliferation.bOff-chip control group.Open in a separate windowFIG. 4.Sterilization performance of the present chip with E. coli and S. aureus as test bacteria. All the original population was 106/ml. Inserted images showed the images of the culture disk after bacteria incubation.Sterilization of another commonly encountered bacterium, Staphylococcus aureus, with initial population of 106/ml was also tested in the present chip, as shown in Figure Figure4.4. Similarly, no noticeable S. aureus proliferation was found when the sterilization temperature was higher than 100 °C.In short, we demonstrated a microfluidic sterilization strategy by utilizing a continuous flowing high temperature/pressure chip. The population of E. coli or S. aureus was reduced from 106/ml to an undetectable level when the sterilization temperature of the chip was higher than 100 °C. The chip holds promising potential in developing portable microsystem for biological/clinical applications.  相似文献   

5.
Surface-enhanced Raman scattering (SERS) shows promise for identifying single bacteria, but the short range nature of the effect makes it most sensitive to the cell membrane, which provides limited information for species-level identification. Here, we show that a substrate based on black silicon can be used to impale bacteria on nanoscale SERS-active spikes, thereby producing spectra that convey information about the internal composition of the bacterial capsule. This approach holds great potential for the development of microfluidic devices for the removal and identification of single bacteria in important clinical diagnostics and environmental monitoring applications.Plasma etching of silicon can be used to produce inexpensive, large surface area, nano-textured surfaces known as black silicon. Recently, it has been shown that black silicon nano-needles can impale bacteria1 and that it can be used as a sensor in microfluidic devices.2 When coated by a plasmonic metal, such as gold, the nano-textured surface of black silicon is ideal for use as a surface-enhanced Raman scattering (SERS) sensing platform.3 This work aims to investigate whether gold-coated black silicon nano-needles can be used to both impale bacteria and identify them by SERS. This combination of properties would promote the development of microfluidic devices for the removal and monitoring of bacteria in a wide range of medical, environmental, and industrial applications.4Black silicon was fabricated by a reactive ion etching technique,5 resulting in pyramidal-shaped spikes of height 185 ± 30 nm, full width at half height of 54 ± 10 nm, and 10 ± 2.4 nm radius of curvature at the tip. Samples were then magnetron sputter coated with 200 nm of gold, as this coating thickness was found to provide a suitable compromise between SERS enhancement and impalement efficiency. E. coli (ATCC 25922) from −80 °C stock was isolated on a nutrient agar plate (Difco nutrient broth, Becton Dickinson) for approximately 12 h. A single E. coli colony was then inoculated from the plate into 20 ml of nutrient broth media and incubated overnight at 37 °C with orbital shaking at 200 rpm. The total biomass of overnight culture was adjusted to an optical density of 0.3 at λ = 600 nm by adding fresh sterile nutrient broth (Cary 50 spectrophotometer, Agilent). The E. coli planktonic cells were washed three times by centrifugation at 12 000 rpm (Centrifuge 5804 R, Eppendorf) for 2 min. The washed cells were then re-suspended in a low strength minimum medium (Dulbecco A, phosphate buffered saline). A volume of 100 μl of solution was pipetted onto substrates and left to incubate for 1 h on the bench. Separate sets of samples were created for scanning electron microscope (SEM) imaging, live/dead staining, and SERS. Three sets were needed as each of these measurements altered the samples and left them unsuitable for further analysis.The first set of samples was washed three times with milliQ water after incubation, allowed to dry and then immediately sputter coated with gold using the Emitech K975x (operating current 35 mA, sputter time 32 s, stage rotation 138 rpm, and vacuum of 1 × 10−2 mbar). SEM imaging was performed with a Zeiss Supra 40VP in high vacuum mode with a working distance of 5 mm and an accelerating voltage of 3 kV. Figure Figure11 shows an example of the different levels of impalement that occurred on the black silicon surface. All cells showed signs of damage, but in some cases, the damage was limited to the perimeter of the cell and the main body appeared whole. In other cases, the entire cell had collapsed onto the spikes.Open in a separate windowFIG. 1.A typical SEM image showing E. coli cells with different levels of impalement on gold-coated black silicon.The second set of samples was used for live/dead staining (Invitrogen BacLight Bacterial Viability Kit L7012) with 3.34 mM SYTO 9 (green fluorescence) and 20 mM propidium iodide (red fluorescence). Equal volumes of both dyes were mixed thoroughly in a tube and added to the sample in a ratio of 3 μl of mixed dye to 1 ml of bacterial suspension. After mixing, a volume of 100 μl of the solution was pipetted onto the substrates, which were then incubated at room temperature in the dark for 15 min, before the staining solution was removed by pipetting. The substrates were then washed three times with milliQ water and mounted on a microscope slide for fluorescence imaging. The substrates were not allowed to dry and were stored in phosphate buffered saline at 4 °C when not in use. An epifluorescence microscope (Olympus IX71) with a mercury lamp source and a 60× water immersion objective was used to collect live/dead images from the substrates. Two filter blocks were used to collect the images: U-MNIBA2 blue excitation narrow band delivered green emission (live) and U-MWIG2 green excitation wide band provided red emission (dead).The live/dead image in Figure Figure22 shows a mix of both live and dead cells on the black silicon sample. The prevalence of live cells could be due to the incomplete impalement seen under SEM for some cells. It can also be explained by the sample still being wet during live/dead staining. The cells are dried prior to imaging in the SEM and this could weaken the cell wall and allow capillary forces to draw the cells onto the spikes for impalement. This hypothesis is supported by the large number of cells on the stained sample and the presence of cell groupings and cells imaged during mid-division. If the cells were immediately impaled, then such activity would not have been visible and a greater proportion of red cells would be expected.Open in a separate windowFIG. 2.Epifluorescence image showing live (green) and dead (red) E. coli cells after incubation on gold-coated black silicon.The third set of samples was washed three times with milliQ water after incubation and allowed to dry prior to spectral analysis. SERS spectra were collected with a Renishaw inVia Raman spectrometer operating at 785 nm with a 1200 l/mm grating. Power at the sample was 150 mW focused with a 100 × /0.85 NA objective to obtain a diffraction limited laser spot. The resulting spot size (≤2 μm in diameter) is well matched to the size of the bacterial cells. Spectra were collected with three accumulations of 10 s. Data were background subtracted6 and normalised to unity for ease of plotting. A great deal of variability was observed in the resulting spectra, as shown in Figure Figure33.Open in a separate windowFIG. 3.SERS spectra of E. coli after incubation on a gold-coated black silicon substrate. The spectrum numbers represent single cells at different locations and different levels of impalement.It should be noted that E. coli SERS is known to produce a high level of variability,7–12 depending on the experimental setup.13 However, the variability seen in the SERS spectra of Fig. Fig.33 is unusual for measurements performed under consistent experimental conditions. This increased level of variability may be related to the different levels of impalement seen in Fig. Fig.1,1, which results in the probing of different internal components. SERS is a surface sensitive technique, with the signal primarily arising within 2 nm of the metal surface.14 Note that unlike apertureless nanoprobes15 or conical plasmonic nanotips,16 the SERS signal in black silicon arises primarily from “hot spots” between the spikes, where the plasmon resonance field is particularly strong.17 Therefore, depending on the depth and location of impalement, different biomolecules are expected to be excited by this novel substrate.Some peaks occur in the same position for multiple spectra (e.g., peak positions 420, 893, 1001, 1285, and 1307 cm−1), but there are also a lot of unique peaks. The vertical lines in Fig. Fig.33 indicate peaks which have appeared in the literature for SERS of E. coli.7–12 Spectrum 3 has a high proportion of peaks matching published values. This is also the case for spectrum 5, which shares a few peak positions with spectrum 3. Preliminary peak allocations have identified carbohydrates11 (420 cm−1), tyrosine11 (650 cm−1), adenine10,11 (706 and 735 cm−1), hypoxanthine7 (722 and1373 cm−1), phenylalanine9 (1001 cm−1), amide III (Ref. 10) (1285 cm−1), CH2 deformation12 (1556 cm−1), and C=C10 (1587 cm−1).Given the varying levels of impalement observed in the SEM, it appears that the spike shape and Au coating should be further optimized to ensure that the entire cell is consistently pierced and the internal biomolecules are more comprehensively probed. In this way, it may be possible to obtain a more reproducible SERS spectrum of the internal biomolecular constituents of single bacterial cells, thereby providing rapid identification for medical and environmental diagnostic applications. Given that SERS is insensitive to water,4 future work should aim to achieve impalement in an aqueous environment, so that the full capability of microfluidics can be used to separate and concentrate suspended bacteria before presenting them to the substrate for rapid analysis.4 This suggests a broad range of potential applications in the detection, monitoring, and control of bacterial contamination.  相似文献   

6.
7.
8.
Polymer-based microneedles have drawn much attention in transdermal drug delivery resulting from their flexibility and biocompatibility. Traditional fabrication approaches are usually time-consuming and expensive. In this study, we developed a new double drawing lithography technology to make biocompatible SU-8 microneedles for transdermal drug delivery applications. These microneedles are strong enough to stand force from both vertical direction and planar direction during penetration. They can be used to penetrate into the skin easily and deliver drugs to the tissues under it. By controlling the delivery speed lower than 2 μl/min per single microneedle, the delivery rate can be as high as 71%.Microelectromechanical systems (MEMS) technology has enabled wide range of biomedical devices applications, such as micropatterning of substrates and cells,1 microfluidics,2 molecular biology on chips,3 cells on chips,4 tissue microengineering,5 and implantable microdevices.6 Transdermal drug delivery using MEMS based devices can delivery insoluble, unstable, or unavailable therapeutic compounds to reduce the amount of those compounds used and to localize the delivery of potent compounds.7 Microneedles for transdermal drug delivery are increasingly becoming popular due to their minimally invasive procedure,8 promising chance for self-administration,9 and low injury risks.10 Moreover, since pharmaceutical and therapeutic agents can be easily transported into the body through the skin by microneedles,11, 12 the microneedles are promising to replace traditional hypodermic needles in the future. Previously, various microneedles devices for transdermal drug delivery applications have been reported. They have been successfully fabricated by different materials, including silicon,13 stainless steel,14 titanium,15 tantalum,16 and nickel.17 Although microneedles with these kinds of materials can be easily fabricated into sharp shape and offer the required mechanical strength for penetration purpose, such microneedles are prone to be damaged18 and may not be biocompatible.19 As a result, polymer based microneedles, such as SU-8,20, 21 polymethyl meth-acrylate (PMMA),22, 23 polycarbonates (PCs),24, 25 maltose,26, 27 and polylactic acid (PLA),28, 29 have caught more and more attentions in the past few years. However, in order to obtain ultra-sharp tips for penetrating the barrier layer of stratum corneum,30 conventional fabrication technologies, for instances, PDMS (Polydimethylsiloxane) molding technology,31, 32 stainless steel molding technology,33 reactive ion etching technology,34 inclined UV (Ultraviolet) exposure technology,35 and backside exposure with integrated lens technology36 are time-consuming and expensive. In this paper, we report an innovative double drawing lithography technology for scalable, reproducible, and inexpensive microneedle devices. Drawing lithography technology37 was first developed by Lee et al. They leveraged the polymers'' different viscosities under different temperatures to pattern 3D structures. However, it required that the drawing frames need to be regular cylinders, which is not proper for our devices. To solve the problem, the new double drawing lithography is developed to create sharp SU-8 tips on the top of four SU-8 pillars for penetration purpose. Drugs can flow through the sidewall gaps between the pillars and enter into the tissues under the skin surface. The experiment results indicate that the new device can have larger than 1N planar buckling force and be easily penetrated into skin for drugs delivery purpose. By delivering glucose solution inside the hydrogel, the delivering rate of the microneedles can be as high as 71% when the single microneedle delivery speed is lower than 2 μl/min.An array of 3 × 3 SU-8 supporting structures was patterned on a 140 μm thick, 6 mm × 6 mm SU-8 membrane (Fig. (Fig.1a).1a). Each SU-8 supporting structure included four SU-8 pillars and was 350 μm high. The four pillars were patterned into a tubelike shape on the membrane (Fig. (Fig.1b).1b). The inner diameter of the tube was 150 μm, while the outer diameter was 300 μm. SU-8 needles of 700 μm height were created on the top of SU-8 supporting structures to ensure the ability of transdermal penetration. Two PDMS layers were bonded with SU-8 membrane to form a sealed chamber for storing drugs from the connection tube. Once the microneedles entered into the tissue, drugs could be delivered into the body through the sidewall gaps between the pillars (Fig. (Fig.1c1c).Open in a separate windowFigure 1Schematic illustration of the SU-8 microneedles. (a) Overview of the whole device; (b) SU-8 supporting structures made of 4 SU-8 pillars; and (c) enlarged view of a single SU-8 microneedle.The fabrication process of SU-8 microneedles is shown in Fig. Fig.2.2. SU-8 microneedles fabrication started from a layer of Polyethylene Terephthalate (PET, 3M, USA) film pasted on the Si substrate by sticking the edge area with kapton tape (Fig. (Fig.2a).2a). The PET film, a kind of transparent film with poor adhesion to SU-8, was used as a sacrificial layer to dry release the final device from Si substrate. A 140 μm thick SU-8 layer was deposited on the top of this PET film. To ensure a uniform surface of this thick SU-8 layer, the SU-8 deposition was conducted in two steps coating. After exposed under 450 mJ/cm2 UV, the membrane pattern could be defined (Fig. (Fig.2b).2b). In order to ensure an even surface for following spinning process, another 350 μm SU-8 layer was directly deposited on this layer in two steps without development. With careful alignment, an exposure of 650 mJ/cm2 UV energy was performed on this 350 μm SU-8 layer to define the SU-8 supporting structures (Fig. (Fig.2c).2c). The SU-8 structure could be easily released from the PET substrate by removing the kapton tape and slightly bending the PET film. Two PDMS layers were bonded with this SU-8 structure by a method reported by Zhang et al.38 (Fig. (Fig.2d2d).Open in a separate windowFigure 2Fabrication process for SU-8 microtubes. (a) Attaching a PET film on the Si substrate; (b) exposing the first layer of SU-8 membrane without development; (c) depositing and patterning two continuous SU-8 layers as sidewall pillars; (d) releasing the SU-8 structure from the substrate and bonding it with PDMS; (e) drawing hollowed microneedles on the top of supporting structures; (f) baking and melting the hollowed microneedles to allow the SU-8 flow in the gaps between pillars; and (g) drawing second time on the top of the melted SU-8 flat surface to get microneedles.In our previous work,39 we used one time stepwise controlled drawing lithography technology for the sharp tips integration. However, since the frame used to conduct drawing process in present study is a four-pillars structure rather than a microtube, the conventional drawing process can only make a hollowed tip but not a solid tip structure (Fig. (Fig.3).3). This kind of tip was fragile and could not penetrate skin in the practical testing process. To solve the problem, we developed an innovative double drawing lithography process. After bonding released SU-8 structure with PDMS layers (Fig. (Fig.2d),2d), we used it to conduct first time stepwise controlled drawing lithography37 and got hollowed tips (Fig. (Fig.2e).2e). Briefly, the SU-8 was spun on the Si substrate and kept at 95 °C until the water inside completely vaporized. Device of SU-8 supporting structures was fixed on a precision stage. Then, the SU-8 supporting structures were immersed into the SU-8 by adjusting the precision state. The SU-8 were coated on the pillars'' surface. Then, the SU-8 supporting structures were drawn away from the interface of the liquid maltose and air. After that, the temperature and drawing speed were increased. Since the SU-8 was less viscous at higher temperature, the connection between the SU-8 supporting structures and surface of the liquid SU-8 became individual SU-8 bridge, shrank, and then broke. The end of the shrunk SU-8 bridge forms a sharp tip on the top of each SU-8 supporting structure when the connection was separated. After the hollowed tips were formed in the first step drawing process, the whole device was baked on the hotplate to melt the hollowed SU-8 tips. Melted SU-8 reflowed into the gaps between four pillars and the tips became domes (Fig. (Fig.2f).2f). Then, a second drawing process was conducted on the top of melted SU-8 to form sharp and solid tips (Fig. (Fig.2g).2g). The final fabricated device is shown in Fig. Fig.44.Open in a separate windowFigure 3A hollowed SU-8 microneedle fabricated by single drawing lithography technology (scale bar is 100 μm).Open in a separate windowFigure 4Optical images for the finished SU-8 microneedles.During the double drawing process, as long as the heated time and temperature were controlled, the SU-8 flow-in speed of SU-8 inside the gaps could be precisely determined. The relationship between baking temperature and flow-in speed was studied. As shown in Fig. Fig.5,5, the flow-in speed is positive related to the baking temperature. The explanation for this phenomena is that the SU-8''s viscosity is different under different baking temperatures.40 Generally, baked SU-8 has 3 status when temperature increases, solid, glass, and liquid. The corresponding viscosity will decrease and the SU-8 can also have higher fluidity. When the baking temperature is larger than 120 °C, the flow-in speed will increase sharply. But, if the baking temperature is higher, the SU-8 will reflow in the gaps too fast, which makes the flow-in depth hard to be controlled. There is a high chance that the whole gaps will be blocked, and no drugs can flow through these gaps any more. Considering that the total SU-8 supporting structure is only 350 μm high, we choose 125 °C as baking temperature for proper SU-8 flow-in speed and easier SU-8 flow-in depth control.Open in a separate windowFigure 5The relationship between flow-in speed and baking temperature.To ensure the adequate stiffness of the SU-8 microneedles in vertical direction, Instron Microtester 5848 (Instron, USA) was deployed to press the microneedles with the similar method reported by Khoo et al.41 As shown in Fig. Fig.6a,6a, the vertical buckling force was as much as 8.1N, which was much larger than the reported minimal required penetration force.42 However, in the previous practical testing experiments, even though the microneedles were strong enough in vertical direction, the planar shear force induced by skin deformation might also break the interface between SU-8 pillars and top tips. In our new device with four pillars supporting structure, the SU-8 could flow inside the sidewall gaps between the pillars to form anchors. These anchors could enhance microneedles'' mechanical strength and overcome the planar shear force problems. Moreover, the anchors strength could be improved by controlling the SU-8 flow-in depth. Fig. Fig.77 shows that the flow-in depth increases when the baking time increases as the baking time increases at 125 °C. Fig. Fig.6b6b shows that the corresponding planar buckling force can be improved to be larger than 1 N by increasing flow-in depth. Some sidewall gaps at bottom are kept on purpose for drugs delivery; hence, the flow-in depth is chosen as 200 μm.Open in a separate windowFigure 6(a) Measurement of the vertical buckling force. (b) The planar buckling force varies under different flow-in depth (I, II, III, and IV corresponding to the certain images in Fig. Fig.77).Open in a separate windowFigure 7Different flow-in depth inside the gaps between SU-8 pillars. (a) 0 μm; (b) 100 μm; (c) 200 μm; and (d) 350 μm (scale bar is 100 μm).The penetration capability of the 3 × 3 SU-8 microneedles array is characterized by conducting the insertion experiment on the porcine cadaver skin. 10 microneedles devices were tested and all of them were strong enough to be inserted into the tissue without any breakage. Histology images of the skin at the site of one microneedle penetration were derived to prove that the sharp conical tip was not broken during the insertion process (Fig. (Fig.8).8). It also shows penetrated evidence because the hole shape is the same as the sharp conical tip.Open in a separate windowFigure 8Histology image of individual microneedle penetration (scale bar is 100 μm).In order to verify that the drug solution can be delivered into tissue from the sidewall gaps of the microneedles, FITC (Fluorescein isothiocyanate) (Sigma Aldrich, Singapore) solution was delivered through the SU-8 microneedles after they were penetrated into the mouse cadaver skin. The representative results were then investigated via a confocal microscope (Fig. (Fig.9).9). The permeation pattern of the solution along the microchannel created by microneedles confirmed the solution delivery results. The black area was a control area without any diffused florescent solution. In contrast, the illuminated area in Fig. Fig.99 indicates the area where the solution has diffused to it. These images were taken consecutively from the skin surface down to 180 μm with 30 μm intervals. The diffusion area had a similar dimension with the inserted microneedles. It has proved that the device can be used to deliver drugs into the body.Open in a separate windowFigure 9Images of confocal microscopy to show the florescent solution is successfully delivered into the tissue underneath the skin surface. (a) 30 μm; (b) 60 μm; (c) 90 μm; (d) 120 μm; (e) 150 μm; and (f) 180 μm (scale bar is 100 μm).Due to the uneven surface of deformed skin, there is always tiny gap happened between tips of some microneedles and local surface skin. The microneedles could not be entirely inserted into the tissue. Drugs might leak to the skin surface through the sidewall gaps under certain driven pressure. Hydrogel absorption experiment was conducted to quantify the delivery rate (i.e., the ratio of solution delivered into tissues in the total delivered volume) and to optimize the delivery speed. Using hydrogel as the tissue model for quantitative analysis of microneedle releasing process was reported by Tsioris et al.43 The details are shown here. Gelatin hydrogel was prepared by boiling 70 ml DI (Deionized) water and mixing it with 7 g of KnoxTM original unflavored gelatin powder. The solution was poured into petri dish to 1 cm high. Then, the petri dish was put into a fridge for half an hour. Gelatin solution became collagen slabs. The collagen slabs were cut into 6 mm × 6 mm sections. A piece of fully stretched parafilm (Parafilm M, USA) was tightly mounted on the surface of the collagen slabs. This parafilm was used here to block the leaked solution further diffusing into the collagen slab in the delivery process. Then, the microneedles penetrated the parafilm and went into the collagen slab. Controlled by a syringe pump, 0.1 ml–0.5 mg/ml glucose solution was delivered into the collagen slab under different speeds. Methylene Blue (Sigma Aldrich, Singapore) was mixed into the solution for better inspection purpose (Fig. 10a). Then, the collagen slabs was digested in 1 mg/ml collagenase (Sigma Aldrich, Singapore) at room temperature (Fig. 10b). It took around 1 h that all the collagen slabs could be fully digested (Fig. 10d). The solution was collected to measure the glucose concentration with glucose detection kit (Abcam, Singapore). Briefly, both diluted glucose standard solution and the collected glucose solution were added into a series of wells in a well plate. Glucose assay buffer, glucose enzyme, and glucose substrate were mixed with these samples in the wells. After incubation for 30 min, their absorbance were examined by using a microplate reader at a wavelength of 450 nm. By comparing the readings with the measured concentration standard curve (Fig. 11a), the glucose concentration in the hydrogel, the glucose absorption rate in the hydrogel, and the solution delivery rate by microneedles could be measured and calculated. As shown in Fig. 11b, when the delivering speed of a single microneedle increased from 0.1 μl/min to 2 μl/min, the glucose absorption rate also increased. Most of the glucose solution from microneedles could go into the hydrogel. The delivered rate could be as high as 71%. The rest solution leaked from sidewall gaps and blocked by parafilm. However, when the delivered speed for a single microneedle was larger than 2 μl/min, the hydrogel absorption rate was saturated. More and more solution could not go into the hydrogel but leak from the sidewall gaps. Then, the delivered rate decreased. Therefore, 2 μl/min was chosen as the optimized delivery speed for the microneedle.Open in a separate windowFigure 10Glucose solution could be delivered into the hydrogel, and the collagen stabs were dissolved by collagenase.Open in a separate windowFigure 11(a) Standard curve for glucose detection; (b) glucose absorption rate and solution delivery rate in a single needle corresponding to different delivery speed.In conclusion, a drug delivery device of integrated vertical SU-8 microneedles array is fabricated based on a new double drawing lithography technology in this study. Compared with the previous biocompatible polymer-based microneedles fabrication technology, the proposed fabrication process is scalable, reproducible, and inexpensive. The fabricated microneedles are rather strong along both vertical and planar directions. It is proved that the microneedles were penetrated into the pig skin easily. The feasibility of drug delivery using SU-8 microneedles is confirmed by FITC fluorescent delivery experiment. In the hydrogel absorption experiment, by controlling the delivery speed under 2 μl/min per microneedle, the delivery rate provided the microneedle is as high as 71%. In the next step, the microneedles will be further integrated with microfluidics on a flexible substrate, forming a skin-patch like drug delivery device, which may potentially demonstrate a self-administration function. When patients need an injection treatment at home, they can easily use such a device just like using an adhesive bandage strip.  相似文献   

9.
Fuchs (2010 Fuchs, C. 2010. Labor in information capitalism and on the Internet. The Information Society 26:179196.[Taylor & Francis Online], [Web of Science ®] [Google Scholar], 2012 Fuchs, C. 2012. With or without Marx? With or without capitalism?: A re-joinder to Adam Arvidsson and Eleanor Colleoni. tripleC 10 (2):63345. [Google Scholar]) argues that users of social media produce value and surplus value in the Marxian sense. Arvidsson and Colleoni (2012 Arvidsson, A., and E. Colleoni. 2012. Value in information capitalism and on the Internet. The Information Society 28:13550.[Taylor & Francis Online], [Web of Science ®] [Google Scholar]) critique this hypothesis, claiming that Marx's theory of value is irrelevant to the regime of value production on social media platforms in particular and in informational capitalism in general. They claim that the affective relations and financial speculations that generate value on social media are not dependent on labor time. This article critically engages Fuchs, and Arvidsson and Colleoni, by revisiting Marx's theory of value. Contra Fuchs, we argue that audiences do not produce value and surplus value—neither for social nor for mass media. Contra Arvidsson and Colleoni, we argue that so-called affective relations (philia) do not produce value either. Instead we demonstrate that social media generate revenue from four primary sources—by leasing advertisement space to generate advertisement rent, by selling information, by selling services to advertisers, and by generating profits from fictitious capital and speculative windfalls. All four, we argue, can be adequately explained by Marx's theory of value.  相似文献   

10.

Background

Short-chain acyl-CoA dehydrogenase deficiency (SCADD) is a rare inherited mitochondrial fatty acid oxidation disorder associated with variations in the ACADS (Acyl-CoA dehydrogenase, C-2 to C-3 short chain) gene. SCADD has highly variable biochemical, genetic and clinical characteristics. Phenotypes vary from fatal metabolic decompensation to asymptomatic individuals.

Subject and methods

A Romani boy presented at 3 days after birth with hypoglycaemia, hypotonia and respiratory pauses with brief generalized seizures. Afterwards the failure to thrive and developmental delay were present. Organic acids analysis with gas chromatography-mass spectrometry (GS/MS) in urine and acylcarnitines analysis with liquid chromatography-tandem mass spectrometry (LC-MS/MS) in dried blood spot were measured. Deoxyribonucleic acid (DNA) was isolated from blood and polymerase chain reactions (PCRs) were performed for all exons. Sequence analysis of all exons and flanking intron sequences of ACADS gene was performed.

Results

Organic acids analysis revealed increased concentration of ethylmalonic acid. Acylcarnitines analysis showed increase of butyrylcarnitine, C4-carnitine. C4-carnitine was 3.5 times above the reference range (<0.68 µmol/L). Confirmation analysis for organic acids and acylcarnitine profile was performed on the second independent sample and showed the same pattern of increased metabolites. Sequence analysis revealed 3-bp deletion at position 310-312 in homozygous state (c.310_312delGAG). Mutation was previously described as pathogenic in heterozygous state, while it is in homozygous state in our patient.

Conclusions

In our case clinical features of a patient, biochemical parameters and genetic data were consistent and showed definitely SCAD deficiency.Key words: SCAD deficiency, short chain acyl-CoA dehydrogenase deficiency, screening, acylcarnitine, polymorphism, genetic  相似文献   

11.
Morphological plasticity is an important survival strategy for bacteria adapting to stressful environments in response to new physical constraints. Here, we demonstrate Escherichia coli morphological plasticity can be induced by switching stress levels through the physical constraints of periodic micro-nanofluidic junctions. Moreover, the generation of diverse morphological aberrancies requires the intact functions of the divisome- and elongasome-directed pathways. It is also intriguing that the altered morphologies are developed in bacteria undergoing morphological reversion as stresses are removed. Cell filamentation underlies the most dominant morphological phenotypes, in which transitions between the novel pattern formations by the spatial regulators of the divisome, i.e., the Min system, are observed, suggesting their potential linkage during morphological reversion.Most bacteria have evolved sophisticated systems to manage their characteristic morphology by orchestrating the spatiotemporal synthesis of the murein sacculus (peptidoglycan exoskeleton), which is known to be the stress-bearing component of cell wall and presides over de novo generation of cell shape.1 Morphological plasticity is attributed to a bacterial survival strategy as responding to stressful environments such as innate immune effectors, antimicrobial therapy, quorum sensing, and protistan predation.2 It comes of no surprise that stress-induced diversified morphology and mechanisms, ascribed to shape control and determination, have drawn great attention in both fundamental and clinical studies.3–6 The molecular mechanism to form filamentous bacteria has been revealed that both β-lactam antibiotics3 and oxidative radicals produced by phagocytic cells5 trigger the SOS response, promoting cell elongation by inactivating cell division via the blockade of tubulin-like FtsZ, known as the divisome initiator. While apart from the scenario of length control by the divisome-directed filamentation, the elongasome assembled by proteins associated with actin-like MreB complex1,7,8 helps the insertion of peptidoglycans into lateral cell wall, suggesting the role in the determination of cell diameter during cell elongation.Recently, additional mechanisms other than the divisome/elongasome-directed pathways of shape maintenance are discovered to regenerate normal morphology de novo from wall-less lysozyme-induced (LI) spheroplasts of E. coli via a plethora types of aberrant division intermediates.9 Similar morphological reversion from different aberrant bacterial shapes has been observed as squashed wild-type bacteria generated through sub-micron constrictions are released into connected microchambers.10 Previous work using the microfluidic approach focuses on the septation accuracy and robustness of constricted bacteria,11 but the reversion process of stress-released bacteria is not well studied and analyzed. In particular, the aberrant bacterial shape is mainly branched-type with bent and curved variants in the reverting bacteria, analogous to the aberrant intermediate found in the morphological reversion of LI spheroplasts with PBP5-defective mutant.9 Since bacteria suffering from starvation12 or confronting mechanical stresses exerted by phagocytosis and protistan grazing6 can induce morphological alterations, one could manipulate the stress levels of physical constraints by adopting repeated structures of sub-micron constricted channels (nanoslits) and microchambers,10,11 to select and enrich bacteria converting to specified aberrant intermediates. The stress incurred by the nanoslit on bacteria is about the mechanical intervention over de novo synthesis of the cell wall, which is the major factor causing morphological aberrancy, while the second environmental stress comes from bacterial growth in the restricted space of microchamber as bacteria proliferate to full confluency, resulting in growth pressure of high population density, nutrient deficiency, and the size reduction of bacteria.Here, we report the selection of distinctive bacterial morphologies by size shrinkage in the outlet cross-section (W × H = 1.5 × 1.5 μm) of the terminal microchamber in the periodic structures of nanoslit-microchamber (Figs. 1(a) and 1(b)). The fluidic structures were micropatterned on fused silica wafers by photolithography, fabricated through reactive ion etching (RIE) and inductively coupled plasma (ICP) etching, and encapsulated by cover glasses coated with polydimethylsiloxane (PDMS) or polysilsesquioxane (PSQ) layer as described earlier.13,14 Two days after the outgrowth of Escherichia coli (imp4213 [MC4100 ΔlamB106 imp4213]) loaded to the microfluidic device at 25 °C, bacteria started to penetrate into the nanoslit as they proliferated to full confluency in the first microchamber (Fig. 1(c)). It takes about 10 days for bacteria traversing 500 μm long (5 repeated nanoslit-microchamber units) via proliferations and being released from the outlet of the terminal microchamber. The narrowed outlet allows only bacteria with smaller diameters to be squeezed into the spacious and nutrient-rich region, thus it acts as a spatial filter to avoid the passage of branching bacteria with cross-sectional size larger than that of the outlet. The rationale of this design is to select aberrant bacteria prone to promote de novo shape regeneration other than the branched-type, which is the dominant morphology of reverting bacteria in the prior microfluidic constriction study.10 As anticipated, the stress-released bacteria through the narrowed outlet are therefore mostly filamentous (see statistical analysis for cell morphology in the supplementary material).15 However, it is noted that the aberrant morphology of lemon-like shape with tubular poles (Figs. 1(d-1), 1(d-3), and 1(d-11)) is developed about 3 h after the stress-released bacteria escaped through the outlet. Though the generation of the lemon-like aberrancy in bacteria has been reported in PBP5/7-defective E. coli mutant subjected to a high-level inhibition of both MreB and FtsZ, while the same mutant treated with low-level MreB inhibitor, together with antagonized-FtsZ, displays filamentous shape with varying diameters,16 these morphological aberrances can be observed in our system (Figs. 1(d-2) and 1(d-12)). Besides, a high-level inhibition of MreB in E. coli with an intact divisome function is known to cause round bacteria, resembling to the cell morphology of the bacteria shown in Fig. 1(d-4). Interestingly, parallel experiments using bacteria mutants carrying impaired regulatory functions in either the divisome (Min) or the elongasome (MreB) do not develop morphological plasticity (supplementary Fig. S1).15 Taken together, the filamentous and lemon-like variants selected from our microfluidic platform, while elaborating the morphological plasticity and reverting progression, require both the functional divisome/elongasome. Alternatively, the selection by the spatial filter does not fully exclude cells with aberrant shapes such as the branched-type with initial budding (Fig. 1(d-7)), cells with asymmetric cross-section perpendicular to the longitudinal axis (Figs. 1(d-2), 1(d-8), 1(d-9), 1(d-9′), and 1(d-10)), and those resembling to the morphological phenotypes of the division intermediates reported in the LI-spheroplasts carrying genetic defects on some non-cytoskeletal proteins (Figs. 1(d-5) and 1(d-6)). In particular, intracellular vesicles and cell autolysis are observed in some reverting bacteria (Figs. 1(d-5) and 1(d-6)), which are reminiscent to the phenomena reported in the division intermediates of the LI-spheroplasts lacking stress response system (Rcs) or some accessory proteins (PBP1B and LpoB). Unlike the bacteria grow with odd shapes under the stress of nanofluidic confinement only10 (Fig. 1(c)), all the morphological aberrancy reported here are developed in the reverting bacteria, which grow in the spacious and nutrition-rich environment and are free from physical constraints. Further investigations over the expression levels of the divisome/elongasome networks and the stress-response system in bacterial cells subjected to micro-nanofluidic junctions could be insightful in understanding their role in bacterial shape control.9Open in a separate windowFIG. 1.(a) Schematics of the microfluidic device used in this study with an H-shaped geometry (left upper panel), where repeated nanoslit (L×W×H = 50×10×0.4 μm)−microchamber (L×W×H = 50×50×1.5 μm) structures are bridged between two arms of the H-shaped microchannels (left lower panel and enlarged view in right panel). (b) Top-view layout of an individual channel in (a) with close view of the outlet in the terminal microchamber (orange: nanoslits; blue: microchambers). (c) Fluorescence micrograph of E. coli imp4213 penetrating a nanoslit (scale bar: 5 μm). (d) Bright-field micrographs for various cell morphology of the selected imp4213 released from the outlet (magenta arrows: cells with vesicles; scale bar: 5 μm). (e) Sequential bright-field micrographs of morphological reversion. T1–T3 indicate the time after bacteria escaping from the outlet. T1: 3 h; T2: 6 h; T3: 24 h. Scale bar: 10 μm.During the morphological reversion, the stress-released bacteria rapidly increase their size in the first 3 h after escaping from the terminal microchamber (T1 in Fig. 1(e)). Some filamentous bacteria even grow over 50 μm long, though such a morphological phenotype implicates the cessation of functional divisome. With active growth and proliferation, the progeny of stress-released bacteria increase their population but gradually reduce their size about 6 h after being released from the constriction stress (T2 in Fig. 1(e)). Fig. Fig.22 displays the marginal histograms for different shape factors, where Fig. 2(a) is the plot of the minimal Feret diameter (cell diameter) versus Feret diameter (cell length), i.e., the shortest versus the longest distance between any two points with parallel tangents along the cell peripheral, respectively, indicating that cell diameters are larger for reverting bacteria at T1 (mean ± S.E.M. = 1.89 ± 0.08 μm) with respect to T2 (1.51 ± 0.06 μm). Moreover, the histogram of Feret diameter depicts two major populations of the cell length for reverting bacteria at T1, which mostly resume to typical cell length at T2 (the median of Feret diameter = 3.33 μm; see statistical analysis for Fig. Fig.22 in the supplementary material).15 The shape factors of circularity (4π × [area]/[perimeter]2) and aspect ratio ([major axis]/[minor axis] for the cell geometry fitted to an ellipse) confirm the existence of dual populations for bacteria at T1 as well (Fig. 2(b)). About 24 h after escaping (T3 in Fig. 1(e)), almost all the progeny of stress-released bacteria regained the rod shape.Open in a separate windowFIG. 2.Marginal histograms for shape factors measured from the reverting imp4213 at T1 and T2. (a) Minimal Feret diameter (cell diameter) versus Feret diameter (cell length). (b) Circularity versus aspect ratio. N = 366 for T1 and N = 494 for T2.The bacterial size reduction of filamentous and lemon-like shape variants, though involving negative control of the divisome positioning by the spatial regulators of MinCDE system,17 is not completely understood as to how they coordinate in aberrant geometries. Besides, the filamentation of stress-released bacteria during the period of T1 to T2 implicates the inhibition of functional divisome. With minimal perturbation of the divisome by leaky expression of GFP-MinD and MinE (imp4213/Plac-gfpmut2::minD minE), the patterning dynamics of GFP-MinD in different bacterial morphology were time-lapse imaged during morphological reversion. Intriguingly, more than the standing-wave-like pattern of MinD denoted in filamentous E. coli,18 we discovered bidirectional drifting of two standing-wave-like patterns of MinD occur in most reverting bacteria filaments (supplementary Figs. S2(a) and S2(b)).15 The bidirectional drifting in the longitudinal direction of the cells may be emanating from the cell poles (the blue upper panel of Fig. 3(a) and supplementary Fig. S2(c)15) and the cylinder region (the blue lower panel of Fig. 3(a) and supplementary Fig. S2(d)15). Furthermore, the MinD pattern transitions from the standing to traveling waves are occasionally observed (the lower panel of Figs. 3(a) and supplementary Fig. S2(e)15). Notably, the standing-wave-like MinD patterns exhibit bidirectional drifting along the cell longitudinal direction and intermittently change directions, implying the competition between coexisting MinD patterns can be supported under filamentous geometry. Despite there have been observations of multiple wave-packet of traveling waves in filamentous cells,19 the mixture of distinct wave-like MinD patterns have never been experimentally reported. While most intriguingly, multiple drifting movements of wave-like MinD patterns potentiate the mitigation of periodic minima in time-averaged Min gradient in the reverting filamentous bacteria, suggesting the disability of proper divisome positioning for recovering the typical rod shape. Apart from the wave-like movements, amoeba-like motion of Min proteins has been shown in vitro upon synthetic minimal system, but never been verified in vivo.20 Strikingly, here amoeba-like motion of MinD is the dominant mode in lemon-like bacteria and the transitions between wave-like patterns and amoeba-like motion are supported even under filamentous geometry (Figs. 3(b) and 3(c), Multimedia view).Open in a separate windowFIG. 3.Kymographs for GFP-MinD dynamics in selected imp4213 cells during morphological reversion: (a) Mixture modes of standing wave packets and traveling wave. The left panel is the stacked fluorescence micrograph displaying cell shape (scale bar = 5 μm). The kymograph is derived from the filamentous cell indicated by the green arrow (scale bar: 120 s horizontal; 5 μm vertical), where the lower panel follows the upper panel in time. The yellow windows indicate bidirectional-drifting standing wave packets, while the green indicates traveling waves (see also supplementary Fig. S2).15 (b) Sequential fluorescence micrographs of GFP-MinD in lemon-shape imp4213 show amoeba-like motion, with the first left a bright-field image (scale bar: 10 μm). (c) Mixed modes of amoeba-like motion and waves in selected filamentous imp4213 cell indicated by the green arrow in the left panel (scale bar = 5 μm). The filamentous cells depicted in (a) and (c) locate at the top region while the lemon-shape cell in (b) at the central region of the movie (time stamp in min:s). (Multimedia view) [URL: http://dx.doi.org/10.1063/1.4892860.1]In summary, we have demonstrated that the development of bacterial morphological plasticity can be stress-induced by periodic physical constraints with intact functions of the divisome and elongasome-directed pathways. Through size exclusion, the constricted outlet structure designed in our microfluidic device is useful in selecting bacteria with plethora morphological aberrancies other than the branched type. Interestingly, disparate morphological changes, rather than those being directly induced under a stressful environment, can be generated in the stress-released bacteria experiencing morphological reversion. Further, the discovery of novel transitions between the Min patterns in most reverting bacteria implicates its regulatory effect of cell filamentation. However, by exploiting the micro-nanofluidic approach, further investigations of the mechanism underlying the development of morphological plasticity in bacteria adapting to physical constraints are expected in future studies to gain more insights into the molecular basis of shape generation.  相似文献   

12.
Oxidative stress conditions associated with atherosclerosis leads to oxidative modification of low-density lipoprotein (LDL). The body’s capabilities to inhibit LDL oxidation and to remove or neutralize the atherogenic oxidized LDL (ox-LDL) are limited. When the LDL cholesterol level increases in the blood, it leads to dangerous consequences like atherosclerosis, leading to myocardial infarction. The major effect of an antioxidant in the LDL environment is to prevent the formation of ox-LDL (during atherogenesis. Strategies to reduce LDL oxidation and prevent atherogenesis can involve the enrichment of arterial cells with potent antioxidants that can prevent oxidative damage to the arterial wall. The objective of this study is to evaluate the effect of l-arginine on serum lipid and cholesterol levels in the patients of acute myocardial infarction (AMI). The study consisted of 70 AMI patients and 60 healthy individuals (serving as control) age 55–65 years. Serum levels of total cholesterol, high density lipoprotein (HDL), LDL and Triglycerides were determined on day 1 and day 15 of l-arginine administration (oral dose 3 g/day). The total cholesterol/HDL and the LDL/HDL ratio were calculated and compared. As per the observations, l-arginine administration was found to improve the lipid profile of the subjects. Hence it could be used as an adjuvant therapy for AMI and as a preventive measure for the onset of the disease in the healthy elderly also.  相似文献   

13.
This paper describes the use of electro-hydrodynamic actuation to control the transition between three major flow patterns of an aqueous-oil Newtonian flow in a microchannel: droplets, beads-on-a-string (BOAS), and multi-stream laminar flow. We observed interesting transitional flow patterns between droplets and BOAS as the electric field was modulated. The ability to control flow patterns of a two-phase fluid in a microchannel adds to the microfluidic tool box and improves our understanding of this interesting fluid behavior.Microfluidic technologies have found use in a wide range of applications, from chemical synthesis to biological analysis to materials and energy technologies.1,2 In recent years, there has been increasing interest in two-phase flow and droplet microfluidics, owing to their potential for providing a high-throughput platform for carrying out chemical and biological analysis and manipulations.3–8 Although droplets may be generated in many different ways, such as with electric fields or extrusion through a small nozzle,9–12 the most common microfluidic methods are based on the use of either T-junctions or flow-focusing geometries with which uniform droplets can be formed at high frequency in a steady-state fashion.13,14 Various operations, such as cell encapsulation, droplet fusion, splitting, mixing, and sorting, have also been developed, and these systems have been demonstrated for a wide range of applications, including cell analysis, protein crystallization, and material synthesis.1–17In addition to forming discrete droplets, where a disperse phase is completely surrounded by a continuous phase, it is also possible in certain situations to have different phases flow side-by-side. In fact, multi-stream laminar flow, either of the same phase or different phases, has been exploited for both biochemical analysis and microfabrication.1,2,18–20 Beads-on-a-string (BOAS) is another potential flow pattern, which has been attracting attentions in microfluidics field. BOAS flow, owing to its special flow structures, may be particularly useful in some applications, such as optical-sensor fabrication.21 In BOAS flow, queues of droplets are connected by a series of liquid threads, which makes them look like a fluid necklace with regular periods.21–25 The BOAS pattern is easily found in nature, such as silk beads and cellular protoplasm, and is often encountered in industrial processes as well, such as in electrospinning and anti-misting.21,22 In general, it is thought that BOAS structure occurs mostly in viscoelastic fluids22 and is an unstable structure, which evolves continually and breaks eventually.21–29Flow patterns determine the inter-relations of fluids in a microdevice and are an important parameter to control. Common methods for adjusting microfluidic flow patterns include varying the fluid flow rates, fluid properties, and channel geometries. Additionally, the application of an electric field can be a useful supplement for adjusting microfluidic flow patterns, although most work in this area has been focused on droplets and in some cases also on multi-stream laminar flows.30–33 Here, in addition to forming droplets and two-phase laminar flow with electro-hydrodynamic actuation, we also observed a new stable flow pattern in a non-viscoelastic fluid, BOAS flow. Such flow patterns may find use in controlling the interactions between droplets, such as limited mixing by diffusion between neighboring droplets.To generate droplets, we used the flow-focusing geometry (Figure 1(a)), in which aqueous phase (water) was flown down the middle channel and droplets were pinched off by the oil phase (1-octanol) from the two side channels at the junction; Figure 1(b) shows the droplets formed after the junction. To apply electric field along the main channel where the droplets were formed, we patterned a pair of electrodes upstream and downstream of the junction (Figure 1(a); for experimental details, please see Ref. 34 for supplementary material). The average electric field strength may be calculated from the voltages applied and the distance (1.7 mm) between the two electrodes. When a high voltage was applied along the channel between the two electrodes, the aqueous-oil interface at the flow-focusing junction became charged and behaved like a capacitor. As a result, more negative charges were drawn back upstream towards the positive electrode, and left behind more positive charges at the aqueous-oil interface, which then became encapsulated into the aqueous droplets dispersed in the oil phase.Open in a separate windowFIG. 1.(a) Schematic of the setup. (b) Micrograph showing droplet generation in a flow-focusing junction. The scale bar represents 40 μm.The positively charged aqueous-oil interface was stretched under an applied electric field, and by adjusting the voltage and/or the two-phase flow-rate ratio, we found interestingly that various flow patterns emerged. We tested different combinations of applied voltages and flow-rate ratios and found that most of them resulted in similar flow patterns and transitions between flow patterns.Figure Figure22 illustrates the effects of varying the applied voltages on droplets at a fixed liquid flow rate. With increasing electric-field strength and force, we found it was easier for the aqueous phase to overcome interfacial tension and form droplets. For example, as the voltage increased from 0.0 kV to 0.8 kV (average field strength increased from 0 to 0.47 V/μm), droplet-generation frequencies became slightly higher, and the formed droplets were smaller in volume. Additionally, droplets gradually became more spherical in shape at higher voltages.Open in a separate windowFIG. 2.Images showing the effects of applied voltage on droplet shape and flow pattern. Oil-phase flow rate, 0.5 μl/min; aqueous-phase flow rate, 0.2 μl/min. The scale bar represents 40 μm.As the voltage increased further (e.g., up to 1.0 kV in Figure Figure3),3), the distance between neighboring droplets became smaller, and the aqueous-oil interface at the junction was stretched further toward the downstream channel. At a threshold voltage (1 kV here with corresponding average field strength of 0.59 V/μm), the tip of the aqueous-oil interface would catch up with the droplet that just formed, and the tip of the interface of this newly captured droplet would in turn catch up with the interface of the droplet that formed before it. Consequently, a series of threads would connect all the droplets flowing between the two electrodes, thus resulting in a BOAS flow pattern.Open in a separate windowFIG. 3.Series of images showing the reversibility and synchronicity of a transitional flow pattern between droplets and BOAS (bead-on-a-string). Voltage applied, 1.00 kV (corresponding field strength of 0.59 V/μm); oil-phase flow rate, 0.5 μl/min; aqueous-phase flow rate, 0.2 μl/min. The scale bar represents 40 μm.At voltages near the threshold value, the flow pattern was not stable, but oscillated between droplets flow and BOAS flow. Figure Figure33 is a series of images captured by a high-speed camera that show the flow in this transition region. In Figures 3(a) and 3(b), the string of BOAS became thinner over time, and then the BOAS broke into droplets (Figures 3(c) and 3(d)). The newly formed droplets, however, were not stable either. Thin liquid threads would appear and then connect neighboring droplets, and a new switching period between discrete droplets and BOAS would repeat (Figures 3(e)–3(h)). In addition to this oscillation and reversibility, the flow pattern had a synchronous behavior: all the droplets appeared connected simultaneously by liquid threads or were separated at the same time.When the voltage reached 1.3 kV, which corresponded to an average field strength of 0.76 V/μm, a stable BOAS flow was obtained (Figure 4(a)). BOAS structures are thought to be present mostly in viscoelastic fluids,22 because viscoelasticity is helpful in enhancing the growth of beads and in delaying breakup of the string; thus, the viscoelastic filament has much longer life time than its Newtonian counterpart. Here, with the help of electric field, regular BOAS structures are realized in a non-viscoelastic fluid (water) in microchannels.Open in a separate windowFIG. 4.(a) Micrograph showing BOAS flow in a channel. (b) Profile of the top-half of the BOAS flow recorded continuously at a cross-section (shown in Figure 4(a)) of a channel. Voltage applied, 1.30 kV (corresponding field strength of 0.76 V/μm); oil-phase flow rate, 0.5 μl/min; aqueous-phase flow rate, 0.2 μl/min. The scale bar represents 40 μm.Microenvironment and electric fields alter the common evolution of BOAS structure observed in macroscopic or unbound environments. The BOAS structure formed in our experiments is not a stationary pattern, but a steady-state flowing one. Electric-field force prevents liquid strings from breaking between beads, and thus plays a similar role as elastic force in viscoelastic fluids. Figure 4(b) shows the dynamic BOAS profile, obtained at a fixed plane (shown in Figure 4(a)) perpendicularly across the channel as the BOAS structure passed through it. Droplets and liquid-thread diameters were nearly constant during the sampling time. The longer term experiments (over 3 min) showed there were slight variations of the two diameters in time, but the essential BOAS structure still remained qualitatively the same as a whole.When the voltage was further increased, the string diameter became larger and the droplet diameter became smaller. Because of the low flow-rate ratio (0.4) between the aqueous phase and oil phase used in the experiment depicted in Figure Figure4,4, the flow did not further develop into a multi-stream laminar flow, as would be expected at a higher voltage, and instead became unstable and irregular. When the flow-rate ratio was increased to 1.0 and the voltage was adjusted to 3.0 kV (corresponding field strength of 1.76 V/μm), we observed a stable multi-stream laminar flow (Figure (Figure5).5). The aqueous stream flowed in the channel center surrounded by the oil phase on the sides. This experiment showed that higher electric-field strengths alone would not give rise to another stable flow pattern (i.e., multi-stream laminar flow), but a suitable flow-rate ratio of aqueous phase to oil phase is required for the formation of stable two-phase laminar flow.Open in a separate windowFIG. 5.Micrograph showing multi-stream two-phase laminar flow in the channel. Voltage applied, 3.00 kV (corresponding field strength of 1.76 V/μm); oil-phase flow rate, 0.5 μl/min; aqueous-phase flow rate, 0.5 μl/min. The scale bar represents 40 μm.The flow patterns we observed may be described by a phase diagram (Figure (Figure6),6), which depends on two dimensionless numbers: capillary number, Ca = μaUa/σ, and electric Bond number, Boe = E2(εD/σ). Ca and Boe describe the ratio of viscous force to interfacial tension force and the ratio of electric-field force to interfacial tension force, respectively. Here, μa (1 mPa s), σ (8.5 mN/m), ε (7.1 × 10−10 F/m), E, Ua, and D are, respectively, the aqueous-phase viscosity, aqueous-oil interfacial tension, aqueous-phase permittivity, electric field strength, aqueous-phase velocity, and the hydraulic diameter of the channel at the junction. Figure Figure66 shows clearly that at higher Ca, flow pattern changes gradually from droplet to BOAS and to multi-stream laminar flow with increasing Boe, which indicates the increasing importance of the electric-field force compared with the interfacial tension force. At lower Ca, flow pattern and transition show similar trend with increasing Boe as in the higher Ca case, except that multi-stream laminar flow is not observed. The relatively higher viscous force at higher Ca may be necessary for transitioning to the multi-stream laminar flow regime. In addition, Figure Figure66 shows that the BOAS window at the lower Ca is smaller than that at the higher Ca.Open in a separate windowFIG. 6.Phase diagram showing different flow patterns in the Ca and Boe space. Hollow symbols: oil-phase flow rate, 0.5 μl/min; aqueous-phase flow rate, 0.5 μl/min. Solid symbols: oil-phase flow rate, 0.5 μl/min; aqueous-phase flow rate, 0.2 μl/min.In summary, we showed the ability to use electric fields to generate and control different flow patterns in two-phase flow. With the aid of an applied field, we were able to generate BOAS flow patterns in a non-viscoelastic fluid, a pattern that typically requires a viscoelastic fluid. The BOAS structure was stable and remained as long as the applied electric field was on. We also report transitional flow patterns, those between droplets and BOAS exhibited both good reversibility as well as synchronicity. And with a suitable flow-rate ratio between the two phases, BOAS flow could be transitioned into a stable two-phase laminar flow by applying a sufficiently high field strength. Finally, a phase diagram was presented to describe quantitatively the flow-pattern regimes using capillary number and electric Bond number. The phenomena we report here on the properties of two-phase flow under an applied electric field may find use in developing a different approach to exert control over droplet based or multi-phase laminar-flow based operations and assays, and also aid in understanding the physics of multi-phase flow.  相似文献   

14.
15.
Water is transported to Earth''s interior in lithospheric slabs at subduction zones. Shallow dehydration fuels hydrous island arc magmatism but some water is transported deeper in cool slab mantle. Further dehydration at ∼700 km may limit deeper transport but hydrated phases in slab crust have considerable capacity for transporting water to the core-mantle boundary. Quantifying how much remains the challenge.

Water can have remarkable effects when exposed to rocks at high pressures and temperatures. It can form new minerals with unique properties and often profoundly affects the physical, transport and rheological properties of nominally anhydrous mantle minerals. It has the ability to drastically reduce the melting point of mantle rocks to produce inviscid and reactive melts, often with extreme chemical flavors, and these melts can alter surrounding mantle with potential long-term geochemical consequences. At the base of the mantle, water can react with core iron to produce a super-oxidized and hydrated phase, FeO2Hx, with the potential to profoundly alter the mantle and even the surface and atmosphere redox state, but only if enough water can reach such depths [1].Current estimates for bulk mantle water content based on the average H2O/Ce ratio of oceanic basalts from melt inclusions and the most un-degassed basalts, coupled with mass balance constraints for Ce, indicate a fraction under one ocean mass [2], a robust estimate as long as the basalts sampled at the surface tap all mantle reservoirs. The mantle likely contains some primordial water but given that the post-accretion Earth was very hot, water has low solubility and readily degasses from magma at low pressures, and its solubility in crystallizing liquidus minerals is also very low, the mantle just after accretion may have been relatively dry. Thus, it is plausible that most or even all of the water in the current mantle is ‘recycled’, added primarily by subduction of hydrated lithospheric plates. If transport of water to the core–mantle boundary is an important geological process with planet-scale implications, then surface water incorporated into subducting slabs and transported to the core–mantle boundary may be a requirement.Water is added to the basaltic oceanic crust and peridotitic mantle in lithospheric plates (hereafter, slab crust and slab mantle, respectively) at mid-ocean ridges, at transform faults, and in bending faults formed at the outer rise prior to subduction [3]. Estimates vary but about 1 × 1012 kg of water is currently subducted each year into the mantle [4], and at this rate roughly 2–3 ocean masses could have been added to the mantle since subduction began. However, much of this water is returned to the surface through hydrous magmatism at convergent margins, which itself is a response to slab dehydration in an initial, and large, release of water. Meta-basalt and meta-sediments comprising the slab crust lose their water very efficiently beneath the volcanic front because most slab crust geotherms cross mineral dehydration or melting reactions at depths of less than 150 km, and even if some water remains stored in minerals like lawsonite in cooler slabs, nearly complete dehydration is expected by ∼300 km [5].Peridotitic slab mantle may have much greater potential to deliver water deeper into the interior. As shown in Fig. 1a, an initial pulse of dehydration of slab mantle occurs at depths less than ∼200 km in warmer slabs, controlled primarily by breakdown of chlorite and antigorite when slab-therms cross a deep ‘trough’, sometimes referred to as a ‘choke point’, along the dehydration curve (Fig. 1a) [6]. But the slab mantle in cooler subduction zones can skirt beneath the dehydration reactions, and antigorite can transform directly to the hydrated alphabet silicate phases (Phases A, E, superhydrous B, D), delivering perhaps as much as 5 wt% water in locally hydrated regions (e.g. deep faults and fractures in the lithosphere) to transition zone depths [6]. Estimates based on mineral phase relations in the slab crust and the slab mantle coupled with subduction zone thermal models suggest that as much as 30% of subducted water may have been transported past the sub-volcanic dehydration front and into the deeper mantle [4], although this depends on the depth and extent of deep hydration of the slab mantle, which is poorly constrained. Coincidentally, this also amounts to about one ocean mass if water subduction rates have been roughly constant since subduction began, a figure tantalizingly close to the estimated mantle water content based on geochemical arguments [2]. But what is the likely fate of water in the slab mantle in the transition zone and beyond?Open in a separate windowFigure 1.(a) Schematic phase relations in meta-peridotite modified after [6,10,12]. Slab geotherms are after those in [4]. Cold slabs may transport as much as 5 wt% water past ‘choke point 1’ in locally hydrated regions of the slab mantle, whereas slab mantle is dehydrated in warmer slabs. Colder slab mantle that can transport water into the transition zone will undergo dehydration at ‘choke point 2’. How much water can be transported deeper into the mantle and potentially to the core depends on the dynamics of fluid/melt segregation in this region. (b) Schematic showing dehydration in the slab mantle at choke point 2. Migration of fluids within slab mantle will result in water dissolving into bridgmanite and other nominally anhydrous phases with a bulk storage capacity of ∼0.1 wt%, potentially accommodating much or all of the released water. Migration of fluids out of the slab into ambient mantle would also hydrate bridgmanite and other phases and result in net fluid loss from the slab. Conversely, migration of hydrous fluids into the crust could result in extensive hydration of meta-basalt with water accommodated first in nominally anhydrous phases like bridgmanite, Ca-perovskite and NAL phase, but especially in dense SiO2 phases (stishovite and CaCl2-type) that can host at least 3 wt% water (∼0.6 wt% in bulk crust).Lithospheric slabs are expected to slow down and deform in the transition zone due to the interplay among the many factors affecting buoyancy and plate rheology, potentially trapping slabs before they descend into the lower mantle [7]. If colder, water-bearing slabs heat up by as little as a few hundred degrees in the transition zone, hydrous phases in the slab mantle will break down to wadsleyite or ringwoodite-bearing assemblages, and a hydrous fluid (Fig. 1a). Wadselyite and ringwoodite can themselves accommodate significant amounts of water and so hydrated portions of the slab mantle would retain ∼1 wt% water. A hydrous ringwoodite inclusion in a sublithospheric diamond with ∼1.5 wt% H2O may provide direct evidence for this process [8].But no matter if slabs heat up or not in the transition zone, as they penetrate into the lower mantle phase D, superhydrous phase B or ringwoodite in the slab mantle will dehydrate at ∼700–800 km due to another deep trough, or second ‘choke point’, transforming into an assemblage of nominally anhydrous minerals dominated by bridgmanite (∼75 wt%) with, relatively, a much lower bulk water storage capacity (< ∼0.1 wt%) [9] (Fig. 1a). Water released from the slab mantle should lead to melting at the top of the lower mantle [10], and indeed, low shear-wave velocity anomalies at ∼700–800 km below North America may be capturing such dehydration melting in real time [11].The fate of the hydrous fluids/melts released from the slab in the deep transition zone and shallow lower mantle determines how much water slabs can carry deeper into the lower mantle. Presumably water is released from regions of the slab mantle where it was originally deposited, like the fractures and faults that formed in the slab near the surface [3]. If hydrous melts can migrate into surrounding water-undersaturated peridotite within the slab, then water should dissolve into bridgmanite and coexisting nominally anhydrous phases (Ca-perovskite and ferropericlase) until they are saturated (Fig. 1b). And because bridgmanite (water capacity ∼0.1 wt%) dominates the phase assemblage, the slab mantle can potentially accommodate much or all of the released water depending on details of how the hydrous fluids migrate, react and disperse. If released water is simply re-dissolved into the slab mantle in this way then it could be transported deeper into the mantle mainly in bridgmanite, possibly to the core–mantle boundary. Water solubility in bridgmanite throughout the mantle pressure-temperature range is not known, so whether water would partially exsolve as the slab moves deeper stabilizing a melt or another hydrous phase, or remains stable in bridgmanite as a dispersed, minor component, remains to be discovered.Another possibility is that the hydrous fluids/melts produced at the second choke point in the slab mantle at ∼700 km migrate out of the slab mantle, perhaps along the pre-existing fractures and faults where bridgmanite-rich mantle should already be saturated, and into either oceanic crust or ambient mantle (Fig. 1b). If the hydrous melts move into ambient mantle, water would be consumed by water-undersaturated bridgmanite, leading to net loss of water from the slab to the upper part of the lower mantle, perhaps severely diminishing the slab’s capacity to transport water to the deeper mantle and core. But what if the water released from slab mantle migrates into the subducting, previously dehydrated, slab crust?Although slab crust is expected to be largely dehydrated in the upper mantle, changes in its mineralogy at higher pressures gives it the potential to host and carry significant quantities of water to the core–mantle boundary. Studies have identified a number of hydrous phases with CaCl2-type structures, including δ-AlOOH, ϵ-FeOOH and MgSiO2(OH)2 (phase H), that can potentially stabilize in the slab crust in the transition zone or lower mantle. Indeed, these phases likely form extensive solid solutions such that an iron-bearing, alumina-rich, δ-H solid solution should stabilize at ∼50 GPa in the slab crust [12], but only after the nominally anhydrous phases in the crust, (aluminous bridgmanite, stishovite, Ca-perovskite and NAL phase) saturate in water. Once formed, the δ-H solid solution in the slab crust may remain stable all the way to the core mantle boundary if the slab temperature remains well below the mantle geotherm otherwise a hydrous melt may form instead [12] (Fig. 1a). But phase δ-H solid solution and the other potential hydrated oxide phases, intriguing as they are as potential hosts for water, may not be the likely primary host for water in slab crust. Recent studies suggest a new potential host for water—stishovite and post-stishovite dense SiO2 phases [13,14].SiO2 minerals make up about a fifth of the slab crust by weight in the transition zone and lower mantle [15] and recent experiments indicate that the dense SiO2 phases, stishovite (rutile structure—very similar to CaCl2 structure) and CaCl2-type SiO2, structures that are akin to phase H and other hydrated oxides, can host at least 3 wt% water, which is much more than previously considered. More importantly, these dense SiO2 phases apparently remain stable and hydrated even at temperatures as high as the lower mantle geotherm, unlike other hydrous phases [13,14]. And as a major mineral in the slab crust, SiO2 phases would have to saturate with water first before other hydrous phases, like δ-H solid solution, would stabilize. If the hydrous melts released from the slab mantle in the transition zone or lower mantle migrate into slab crust the water would dissolve into the undersaturated dense SiO2 phase (Fig. 1b). Thus, hydrated dense SiO2 phases are possibly the best candidate hosts for water transport in slab crust all the way to the core mantle boundary due to their high water storage capacity, high modal abundance and high-pressure-temperature stability.Once a slab makes it to the core–mantle boundary region, water held in the slab crust or the slab mantle may be released due to the high geothermal gradient. Heating of slabs at the core–mantle boundary, where temperatures may exceed 3000°C, may ultimately dehydrate SiO2 phases in the slab crust or bridgmanite (or δ-H) in the slab mantle, with released water initiating melting in the mantle and/or reaction with the core to form hydrated iron metal and super oxides, phases that may potentially explain ultra-low seismic velocities in this region [1,10]. How much water can be released in this region from subducted lithosphere remains a question that is hard to quantify and depends on dynamic processes of dehydration and rehydration in the shallower mantle, specifically at the two ‘choke points’ in the slab mantle, processes that are as yet poorly understood. What is clear is that subducting slabs have the capacity to carry surface water all the way to the core in a number of phases, and possibly in a phase that has previously seemed quite unlikely, dense SiO2.  相似文献   

16.
The uncontrolled hyperglycemia can lead to disturbances in the cell structure and functions of organs. This study was performed to analyze the “differential proteome” change in rat liver associated with diabetes mellitus in relation to effects of an anti-diabetic herb, Cynodon dactylon leaf extracts. Rats were intraperitoneally injected with alloxan (150 mg/kg/bw) and treated with C. dactylon leaf extracts (450 mg/kg/bw/day/orally). The liver proteins were subjected to proteome analysis using the advanced technologies i.e., 2D electrophoresis (2-DE) and mass spectrometry. Comparison of 2-DE protein distribution profiles among the livers from normal, alloxan-induced diabetic rats and alloxan-induced diabetic rats treated with C. dactylon leaves identified three proteins that were up-regulated in alloxan-induced diabetic rats i.e., nucleophosmin, l-xylulose reductase and carbonic anhydrase III which are known to be mainly involved in ribosome biogenesis, centrosome duplication, cell proliferation, tumor suppression, glucose metabolism, osmo-regulation, water–CO2 balance and acid–base balance. These results help us to understand the elucidation of molecular mechanism connected to liver function and insulin associated with diabetes mellitus. These identified proteins were primarily involved in cell proliferation and homoeostasis of liver tissues upon the treatment with C. dactylon leaf extracts.  相似文献   

17.
We use a lattice-Boltzmann based Brownian dynamics simulation to investigate the separation of different lengths of DNA through the combination of a trapping force and the microflow created by counter-rotating vortices. We can separate most long DNA molecules from shorter chains that have lengths differing by as little as 30%. The sensitivity of this technique is determined by the flow rate, size of the trapping region, and the trapping strength. We expect that this technique can be used in microfluidic devices to separate long DNA fragments that result from techniques such as restriction enzyme digests of genomic DNA.The development of novel methods for manipulating biopolymers such as DNA is required for the continued advancement of microfluidic devices. Techniques such as restriction enzyme digests for genomic sequencing rely on the detection of DNA that differ in length by sometimes thousands of base pairs.1 Methods that separate DNA strands with resolutions on the order of kilobase pairs are required to analyze the products of this technique. To gain an insight into possible techniques to separate polymers, it can be helpful to review the methods to separate particles in microfluidic devices. Experimental work has shown how hydrodynamic mechanisms can lead to separation of particles based on size and deformability.2 Eddies, microvortices, and hydrodynamic tweezers have been used to trap and sort particles. The mechanism of the trapping and sorting arises from the differences between interactions of the particles with the fluid.2–8 In particular, counter-rotating vortices have been used to sort particles and manipulate biopolymers. They have been used to deposit DNA precisely across electrodes9 and trap DNA.10,11 Vortex flow may therefore be a good basis for a technique for sorting DNA by length.Streaming flow has been used in experiments to separate colloids of different size.3,4 Particles are passed through a channel with a flow field driven by oscillating bubbles and pressure. The flow field becomes a combination of closed and open streamlines. The vortex flow is controlled by the accoustic driving of the bubbles while pressure controls the net flow of the fluid. Larger particles are trapped in the closed vortex flow created by the bubbles, while smaller particles can escape the neighborhood of a bubble in the open streamlines. This leads to efficient separation of particles with size differences as small as 1 μm.Previous work on DNA has shown that counter-rotating vortices can be used to trap DNA dynamically. Long strands of DNA have been observed to stretch between the centers of two counter-rotating vortices. The polymer stays trapped in this state for significant amounts of time.12 In a different experiment, the vortices were used to thermally cycle the polymer and allow replication via the polymerase chain reaction (PCR). The DNA is also trapped against one wall by a thermophoretic force in these experiments.10 The strength of the trap is controlled by the gradient in temperature created by a focused infrared laser beam.Trapping DNA at one wall by counter-rotating vortices has also been explored in simulation and found to depend on the Peclet number, Pe = umaxL/Dm, where umax is the maximum speed of the vortex, L is the box size, and Dm is the diffusion coefficient of one bead in the polymer chain.11 The trapping rate of the DNA was shown to depend on the competition between the flow compressing the DNA into the trap region and the diffusion of the DNA out of the trap. For the work presented here, Pe ≅ 2000, similar to the previous work done with the same simulation.We extend the previous work to investigate if counter-rotating vortices can be used to separate DNA of different lengths. We use the same type of simulation outlined in Refs. 11 and 13–17, based on the lattice-Boltzmann method. The simulation method has successfully modeled systems as diverse as thermophoresis of DNA,14 migration of DNA in a microchannel,16 and translocation of DNA through a micropore.17,18 Using this method, the fluid is broken into a lattice with size, ΔL, chosen to be 0.5 μm, and is coupled to a worm-like chain model with Brownian dynamics for the polymer.19,20 The fluid velocity distribution function, ni(r, t), describes the fraction of fluid particles with a discretized velocity, ci, at each lattice site.21–24 A discrete velocity scheme with nineteen different velocities in three dimensions is used. The velocity distributions will evolve according to ni(r+ciΔτ,t+Δτ)=ni(r,t)+Lij[nj(r,t)njeq(r,t)],(1)where L is a collision operator such that the fluid relaxes to the equilibrium distribution, nieq given by a second-order expansion of the Maxwell-Boltzmann distribution nieq=ρaci[1+(ci·u)/cs2+uu:(cicics2I)/(2cs4)],(2)where cs=1/3ΔLΔτ is the speed of sound. Δτ is the time step for the fluid in the simulation, Δτ = 8.8 × 10−5. The coefficients aci are determined by satisfying a local isotropy condition iaciciαciβciγciδ=cs4(δαβδγδ+δαγδbetaγ+δαδδβγ).(3)To simplify computation, the velocity distributions are transformed into moment space. The density ρ, momentum density j, and momentum flux density Π are some of the hydrodynamic moments of ni(r, t). The equilibrium conditions for these three moments are given by ρ=nieq,(4) j=ci·nieq,(5) Π=nieq·cici.(6)L has eigenvalues τ01,τ11,,τ181, which are the characteristic relaxation times of the moments. The Bhatanagar-Gross-Krook model is used to determine L:25 the non-conserved moments have a single relaxation time, τs = 1.0. The conserved moments are density and momentum; for these, τ−1 = 0. Fluctuations are added to the fluid stress as in the method of Ladd.24 We have also compared simulations with lattice sizes of 1 μm and 0.25 μm and found no significant differences in the results.The DNA used in the simulation is represented by a worm-like chain model parameterized to capture the dynamics of YOYO-stained λ DNA in bulk solution at room temperature.15,16,26 Long, flexible DNA is modeled since techniques to separate long DNA molecules with kilobase pair resolution are necessary to complete techniques such as genomic level sequencing using restriction enzyme digests.1 In addition, such DNA is often used in experiment. Its properties are similar to unstained DNA or DNA stained by other methods.27 Each molecule is represented by Nb beads and Nb − 1 springs. A chain composed of Nb − 1 springs will have a contour length of (Nb − 1) × 2.1 μm. The forces acting on each monomer include: an excluded volume force, a non-linear spring force, the viscous drag force, a random force that produces Brownian motion, a repulsive force from the container walls, and an attractive trapping force only at one wall as shown in Fig. Fig.11.13 The excluded volume interaction between beads i and j located at ri and rj is modeled using the following potential: Uijev=12kBTνNks2(34πSs2)exp(3|rirj|24Ss2),(7)where ν=σk3 is the excluded volume parameter with σk = 0.105 μm, the length of one Kuhn segment, Nks = 19.8 is the number of Kuhn segments per spring, and Ss2=Nks/6)σk2 is the characteristic size of the bead. This excluded volume potential reproduces self avoiding walk statistics. The non-linear spring force is based on force-extension curves from experiments and is given by fijS=kBT2σk[(1|rjri|Nksσk)2+4|rjri|nKσk1]rjri|rjri|,(8)which applies when Nks ≫ 1.Open in a separate windowFIG. 1.Simulation set-up. Arrows indicate direction of fluid flow. The region where the trapping force is active is shaded, and its width (Xstick) is shown. The region used to determine the trapping rate is indicated by the area labeled trap region. Figure is not to scale, the trap region and Xstick are smaller than shown.The beads are modeled as freely draining but subject to a drag force given by Ff = ?6πηa(up ? uf).(9)The beads are also subjected to a random forcing term that is drawn from a Gaussian distribution with zero mean and a variance σv = 2kBTζΔt.(10)The random force reproduces Brownian motion. To conserve total momentum, the momentum change imparted to the beads through their interactions with the fluid is balanced by a momentum change in the fluid. The momentum change is distributed to the three closest fluid lattice sites using a linear interpolation scheme based on the proximity of the lattice site to the polymer beads. Through this momentum transfer, hydrodynamic interactions between the beads occur.The beads are repelled from the walls with a force of magnitude Fwall=250kBTσk3(xbeadxwall)2,xbead>(xwall1),(11)where the repulsion range is 1ΔL. Each monomer will also be attracted to the top wall by a force with magnitude Fstick=KstickkBTσk3(xbeadxwall+10)2,xbead>(xwallXstick)(12)and range Xstick (see Fig. Fig.1).1). The sticking force is turned off every one out of one hundred time steps of the polymer (1% of the simulation time steps). We vary both Xstick and Kstick to achieve separation of the polymers.In previous experiments, DNA has been trapped against one wall by using thermophoresis,10 dielectrophoresis,28 and nanoplasmonic tweezers.29 In the case of thermophoresis, the trap strength (Kstick) can be controlled by tuning the intensity of the temperature gradient and the trap extension (Xstick) can be controlled through the area over which the gradient extends. Both of these are set through focusing of the laser used to produce local heating. Similarly, the trap parameters can be controlled when using plasmonic tweezers by controlling the laser beam exciting the nanoplasmonic structures. In dielectrophoresis, the DNA is trapped by an AC electric field and can be controlled by tuning the frequency and amplitude of the field.In this work, the number of polymers, Np, is 10 unless otherwise noted, and the container size is 25 ΔL × 50 ΔL × 2 ΔL. The time step for the fluid is Δτ = 8.8 × 10−5 s, and for the polymer is Δt = 3.7 × 10−6 s. The total simulation time is over 100 chain relaxation times, allowing sufficient independent samples to perform statistical analysis.Two counter-rotating vortices, shown in 1, are produced by introducing external forces to the fluid bound by walls in the x-direction and periodic in the y and z. Two forces of equal magnitude push on the fluid in the upper x region (12ΔL < x < 25ΔL): one in the +y-direction along y = 10ΔL, and one in the –y-direction along y = 40ΔL. Such counter-rotating vortices can be produced in microfluidic channels using acoustically driven bubbles,3,4,30 local heating,10 or plasmonic nanostructures.5 The flow speed is controlled by very different external mechanisms in each case. We therefore choose a simple model to produce fluid flow that is not specific to one mechanism.The simulations are started using random initial conditions, and therefore, both lengths of polymer are dispersed throughout the channel. Within a few minutes, the steady state configurations pictured in Figs. Figs.22 and and33 are reached. We define the steady state as when the number of polymer chains in the trap changes by less than one chain (10 beads) per 1000 polymer time steps. Intermittently, some polymers may still escape and re-enter the trap even in the steady state. Three final configurations are possible: Both the lengths of DNA have become trapped, both lengths continue to rotate freely, or the shorter strand has become trapped while the longer rotates freely. Two of these states leave the polymers mixed; in the third, the strands have separated by size.Open in a separate windowFIG. 2.Snapshots at t = 0Δt (left) and t = 2500Δt (right) showing the separation of 15-bead strands (grey) from 10-bead strands (black) of DNA. For these simulations, Kstick = 55 and Ystick = 0.7ΔL.Open in a separate windowFIG. 3.Snapshots at t = 0Δt and t = 2500Δt showing the separation of 13-bead strands (grey) from 10-bead strands (black) of DNA. For these simulations, Kstick = 55 and Ystick = 0.7ΔL as in Fig. Fig.2.2. Note that one long polymer is trapped, as well as all of the shorter polymers.By tuning the attractive wall force parameters and fluid flow, the separated steady state can be realized. We first set the flow parameters that allow the larger chains to rotate freely at the center of the vortices while the shorter chains rotate closer to the wall. The trap strength, Kstick, and extension, Xstick, are changed until the shorter polymers do not leave the trap. The same parameters were used to separate 10-bead chains from 15-bead and 13-bead chains.As shown in Fig. Fig.2,2, we have been able to separate shorter 10-bead chains from longer 15-bead chains. In the steady state, 97% of the rotating polymers were long polymers averaged over twenty simulations initialized with different random starting conditions. For three simulations, one small polymer would intermittently leave the trap region. In two of these simulations, one long polymer became stably trapped in the steady state. In another simulation, one 15-bead chain was intermittently trapped. On average, the trapped polymers were 5% 15-bead chains and 95% 10-bead chains. Again, 97% of the rotating polymers were 15-bead chains.Simulations conducted with 10-bead and 13-bead chains also showed significant separation of the two sizes as can be seen in Fig. Fig.3.3. In the steady state, 30% of the trapped polymers are 13-bead chains and 70% are 10-bead chains, averaged over twenty different random initial starting conditions and 1000 polymer time steps. Only 14.8% of the shorter polymers were not trapped, leading to 85.2% of the freely rotating chains being 13-bead chains. This is therefore a viable test to detect the presence of these longer chains.We have also separated 20-bead chains from 10-bead chains with all of the shorter chains trapped and all of the longer chains freely rotating in the steady-state. These results do not change for twenty different random initial starting conditions and 1000 polymer time steps. None of the longer polymers intermittently enter the trap region nor do any of the shorter polymers intermittently escape.The separation is achieved by tuning the trapping force and flow rate. Strong flows will push all the DNA molecules into the trap. The final state is mixed, with both short and long strands trapped. For flows that are too weak, the short molecules are not sufficiently compressed by the flow and therefore do not enter the trap region. The end state is mixed, with all polymers freely rotating. Separation is achieved when the flow rate is tuned so that the short strands are compressed against the channel wall while the long polymers rotate near the center of the vortices. The trap strength must then be set sufficiently high enough to prevent the short strands from being pulled by the hydrodynamic drag force out of the trap.The mechanism of the separation depends on the differences in the steady state configurations of the polymers and chances of a polymer escaping the trap. As shown in Fig. Fig.4,4, both longer and shorter chains are pulled into the trap region by the flow. However, the longer chains have a larger chance of a bead escaping into a region of the flow where the fluid velocity is sufficient to pull the entire strand out of the trap. As shown in Ref. 11, the trapping rate depends on diffusion in a polymer depleted region near the trap, in agreement with classical theory which neglects bead-wall interactions. In addition, the theory depends on the single bead diffusion rate and does not take into account the elastic force holding the beads together. Diffusion becomes as significant as convection in the polymer depleted region leading to dependence on the Peclet number. Since longer polymers have more beads; they have more chances of a single bead diffusing through this layer into the region where convection is again more important. Thus, they are pulled out of the trap at a faster rate than the shorter chains.Open in a separate windowFIG. 4.N, number of beads in the trap region, versus time for 15-bead DNA strands (solid line) and 10-bead DNA strands (dashed line). Here, ΔT = 10000Δt. The simulation parameters are the same as in Fig. Fig.22.In addition, longer chains have a second trap resulting from the microflow. As shown in Ref. 12, DNA in counter-rotating vortices can tumble at the center of one vortex or be stretched between the centers of the two vortices. We have observed both these conformations for the longer polymer strand. They are a stable trajectory for the longer polymer that remains outside of the trapping region. As seen in Fig. Fig.4,4, few monomers of the longer chains enter the trap region once the steady state has been reached. However, the shorter polymer rotates at a larger radius than the longer polymer as seen in Fig. Fig.5.5. The shorter polymers therefore are pushed back into the trap while the longer strands rotate stably outside the trapping region.Open in a separate windowFIG. 5.Trajectories of 15-bead DNA (grey) and 10-bead DNA (black). The position of each monomer is plotted for 100 consecutive time steps. Note that the longer polymers rotate in the center of the channel while the shorter polymers rotate at the edges. Simulation parameters are the same as in Fig. Fig.22.This mechanism is similar to the one proposed for the separation of colloids by size in Refs. 3 and 4. In that experimental work, the smaller colloidal particles rotated at larger radii. This allowed the smaller beads to be pushed out of the vicinity of the vortices by the streaming flow, while the larger beads continued to circle. However, in our simulations, we have the additional mechanism of separation based on the increased chance of a longer polymer escaping the trap region. This mechanism is important for maintaining the separation. Long polymers initially in the trap region or which diffuse into the trap would not be able to escape without it.We expect that this technique could be used to detect the sizes of DNA fragments on the order of thousands of base pairs. It relies on the flexibility of the molecule and its interaction with the flow. Common lab procedures such as restriction enzyme digests for DNA fingerprinting can produce these long fragments. Current techniques such as gel electrophoresis require significant time to separate the long strands that move more slowly through the matrix. This effect could therefore be a good candidate for developing a microfluidic analysis that is significantly faster than traditional procedures. Our separation occurs in minutes rather than in hours as for gel electrophoresis.As pointed out in Ref. 2, hydrodynamic effects have been shown to be important for microfluidic devices for separation. We have demonstrated, in simulation, a novel hydrodynamic mechanism for separating polymers by length. We hope that these promising calculations will inspire experiments to verify these results.  相似文献   

18.

Using Layder's domain theory (1997) Layder, D. 1997. Modern social theory:Key debates and new directions, London: UCL Press.  [Google Scholar] as an analytical framework, this article shows how the information society can be measured through various levels of society. Layder's notions of psychobiography, situated activity, social setting, and contextual resources help identify cultural and social indicators for understanding changes in the information society. With the help of empirical indicators for each domain, this article uses the case of Estonia to show that there is often more to the information society than what is captured by traditional measures. This article calls for a context-sensitive approach, which takes into consideration social and cultural indicators. Measurements from all four domains are necessary for understanding the complexity of information-society-related issues.  相似文献   

19.
A flow redirection and single cell immobilization method in a microfluidic chip is presented. Microheaters generated localized heating and induced poly(N-isopropylacrylamide) phase transition, creating a hydrogel that blocked a channel or immobilized a single cell. The heaters were activated in sets to redirect flow and exchange the fluid in which an immobilized cell was immersed. A yeast cell was immobilized in hydrogel and a 4′,6-diamidino-2-phenylindole (DAPI) fluorescent stain was introduced using flow redirection. DAPI diffused through the hydrogel and fluorescently labelled the yeast DNA, demonstrating in situ single cell biochemistry by means of immobilization and fluid exchange.The ability to control microfluidic flow is central to nearly all lab-on-a-chip processes. Recent developments in microfluidics either include microchannel based flow control in which microvalves are used to control the passage of fluid,1 or are based on discrete droplet translocation in which electric fields or thermal gradients are used to determine the droplet path.2, 3 Reconfigurable microfluidic systems have certain advantages, including the ability to adapt downstream fluid processes such as sorting to upstream conditions and events. This is especially relevant for work with individual biomolecules and high throughput cell sorting.4 Additionally, reconfigurable microfluidic systems allow for rerouting flows around defective areas for high device yield or lifetime and for increasing the device versatility as a single chip design can have a variety of applications.Microvalves often form the basis of flow control systems and use magnetic, electric, piezoelectric, and pneumatic actuation methods.5 Many of these designs require complicated fabrication steps and can have large complex structures that limit the scalability or feasability of complex microfluidic systems. Recent work has shown how phase transition of stimuli-responsive hydrogels can be used to actuate a simple valve design.6 Beebe et al. demonstrated pH actuated hydrogel valves.7 Phase transition of thermosensitive poly(N-isopropylacrylamide) (PNIPAAm) using a heater element was demonstrated by Richter et al.8 Phase transition was also achieved by using light actuation by Chen et al.9 Electric heating has shown a microflow response time of less than 33 ms.11 Previous work10 showed the use of microheaters to induce a significant shift in the viscosity of thermosensitive hydrogel to block microchannel flow and deflect a membrane, stopping flow in another microchannel. Additionally, Yu et al.12 demonstrated thermally actuated valves based on porous polymer monoliths with PNIPAAm. Krishnan and Erickson13 showed how reconfigurable optically actuated hydrogel formation can be used to dynamically create highly viscous areas and thus redirect flow with a response time of  ~ 2?s. This process can be used to embed individual biomolecules in hydrogel and suppress diffusion as also demonstrated by others.15, 16 Fiddes et al.14 demonstrated the use of hydrogels to transport immobilized biomolecules in a digital microfluidic system. While the design of Krishnan and Erickson is highly flexible, it requires the use of an optical system and absorption layer to generate a geometric pattern to redirect flow.This paper describes the use of an array of gold microheaters positioned in a single layer polydimethylsiloxane (PDMS) microfluidic network to dynamically control microchannel flow of PNIPAAm solution. Heat generation and thus PNIPAAm phase transition were localized as the microheaters were actuated using pulse width modulation (PWM) of an applied electric potential. Additionally, hydrogel was used to embed and immobilise individual cells, exchange the fluid parts of the microfluidic system in order to expose the cells to particular reagents to carry out an in situ biochemical process. The PDMS microchannel network and the microheater array are shown in Figure Figure11.Open in a separate windowFigure 1A sketch of the electrical circuit and a microscope image of the gold microheaters and the PDMS microchannels. The power to the heaters was modulated with a PWM input through a H-bridge. For clarity, the electrical circuit for only the two heaters with gelled PNIPAAm is shown (H1 and V2). There are four heaters (V1-V4) in the “vertical channels” and three heaters (H1-H3) in the “horizontal” channel.The microchannels were fabricated using a patterned mould on a silicon wafer to define PDMS microchannels, as described by DeBusschere et al.17 and based on previous work.10 A 25 × 75 mm glass microscope slide served as the remaining wall of the microchannel system as well as the substrate for the microheater array. The gold layer had a thickness of 200 nm and was deposited and patterned using E-beam evaporation and photoresist lift-off.21 The gold was patterned to function as connecting electrical conductors as well as the microheaters.It was crucial that the microheater array was aligned with an accuracy of  ~ 20μm with the PDMS microchannel network for good heat localization. The PDMS and glass lid were treated with plasma to activate the surface and alignment was carried out by mounting the microscope slide onto the condenser lens of an inverted microscope (TE-2000 Nikon Instruments). While imaging with a 4× objective, the x, y motorized stage aligned the microchannels to the heaters and the condenser lens was lowered for the glass substrate to contact the PDMS and seal the microchannels.Local phase transition of 10% w/w PNIPAAm solution in the microchannels was achieved by applying a 7 V potential through a H-bridge that received a PWM input at 500 Hz which was modulated using a USB controller (Arduino Mega 2650) and a matlab (Mathworks) GUI. The duty cycle of the PWM input was calibrated for each microheater to account for differences in heater resistances (25?Ω to 52?Ω) due to varying lengths of on-chip connections and slight fabrication inconsistencies, as well as for different flow conditions during device operation. Additionally, thermal cross-talk between heaters required decreasing the PWM input significantly when multiple heaters were activated simultaneously. This allowed confining the areas of cross-linked PNIPAAm to the microheaters, allowing the fluid in other areas to flow freely.By activating the heaters in sets, it was possible to redirect the flow and exchange the fluid in the central area. Figure Figure22 demonstrates how the flow direction in the central microchannel area was changed from a stable horizontal flow to a stable vertical flow with a 3 s response time, using only PNIPAAm phase transition. Constant pressures were applied to the inlets to the horizontal channel and to the vertical channels. Activating heaters V1-4 (Figure (Figure2,2, left) resulted in flow in the horizontal channel only. Likewise, activating heaters H1 and H2 allowed for flow in the vertical channel only. In this sequence, the fluid in the central microchannel area from one inlet was exchanged with fluid from the other inlet. Additionally, by activating heater H3, a particle could be immobilised during the exchange of fluid as shown in Figure Figure33 (top).Open in a separate windowFigure 2Switching between fluid from the horizontal and the vertical channel using hydrogel activation and flow redirection with a response time of 3 s. A pressure of 25 mbar was applied to the inlet of the horizontal channel and a pressure of 20 mbar to the vertical channel. The flow field was determined using particle image velocimetry, in which the displacement of fluorescent seed particles was determined from image pairs generated by laser pulse exposure. Processing was carried out with davis software (LaVision).Open in a separate windowFigure 3A series of microscope images near heater H3 showing: (1a)-(1c) A single yeast cell captured by local PNIPAAm phase transition and immobilized for 5 min before being released. (2a) A single yeast cell was identified for capture by embedding in hydrogel. (2b) The cell as well as the hydrogel displayed fluorescence while embedded due to the introduction of DAPI in the surrounding region. (2c) The diffusion of DAPI towards the cell as the heating power of H3 is reduced after 15 min, showing a DAPI stained yeast cell immobilized.Particle immobilisation in hydrogel and fluid exchange in the central area of the microfluidic network were used to carry out an in situ biochemical process in which a yeast cell injected through one inlet was stained in situ with a 4′,6-diamidino-2-phenylindole (DAPI) solution (Invitrogen), which attached to the DNA of the yeast cell.18 A solution of yeast cells with a concentration of 5 × 107cells/ml suspended in a 10% w/w PNIPAAm solution was injected through the horizontal channel. A solution of 2μg/l DAPI in a 10% w/w PNIPAAm solution was injected through the vertical channel. A single yeast cell was identified and captured near the central heater, and by deactivating the heaters in the vertical channel, DAPI solution was introduced in the microchannels around the hydrogel. After immobilising the cell for 15 min, the heater was deactivated, releasing the cell in the DAPI solution. This process is shown in Figure Figure33 (bottom). The sequence of the heater activation and deactivation in order to immobilize the cell and exchange the fluid is outlined in the supplementary material.21Eriksen et al.15 demonstrated the diffusion of protease K in the porous hydrogel matrix,19 and it was therefore expected that DAPI fluorescent stain (molecular weight of 350 kDa, Ref. 20) would also diffuse. DAPI diffusion is shown in Figure 3(2b) in which the yeast cell shows fluorescence while embedded in the hydrogel. The yeast cell was released by deactivating the central heater and activating all the others to suppress unwanted flow in the microchannel. As a result, the single cell was fully immersed in the DAPI solution. Immobilization of a single cell allows for selection of a cell that exhibits a certain trait and introduction of a new fluid while maintaining the cell position in the field of view of the microscope such that a biochemical response can be imaged continuously.In summary, a microfluidic chip capable of local heating was used to induce phase transition of PNIPAAm to hydrogel, blocking microchannel flow, and thereby allowing for reconfigurable flow. Additionally, the hydrogel was used to embed and immobilise a single yeast cell. DAPI fluorescent stain was introduced using flow redirection, and it stained the immobilized cell, showing diffusion into the hydrogel. The versatile design of this microfluidic chip permits flow redirection, and is suitable to carry out in situ biochemical reactions on individual cells, demonstrating the potential of this technology for forming large-scale reconfigurable microfluidic networks for biochemical applications.  相似文献   

20.
Bipolar membranes (BMs) have interesting applications within the field of bioelectronics, as they may be used to create non-linear ionic components (e.g., ion diodes and transistors), thereby extending the functionality of, otherwise linear, electrophoretic drug delivery devices. However, BM based diodes suffer from a number of limitations, such as narrow voltage operation range and/or high hysteresis. In this work, we circumvent these problems by using a novel polyphosphonium-based BM, which is shown to exhibit improved diode characteristics. We believe that this new type of BM diode will be useful for creating complex addressable ionic circuits for delivery of charged biomolecules.Combined electronic and ionic conduction makes organic electronic materials well suited for bioelectronics applications as a technological mean of translating electronic addressing signals into delivery of chemicals and ions.1 For complex regulation of functions in cells and tissues, a chemical circuit technology is necessary in order to generate complex and dynamic signal gradients with high spatiotemporal resolution. One approach to achieve a chemical circuit technology is to use bipolar membranes (BMs), which can be used to create the ionic equivalents of diodes2, 3, 4, 5 and transistors.6, 7, 8 A BM consists of a stack of a cation- and an anion-selective membrane, and functions similar to the semiconductor PN-junction, i.e., it offers ionic current rectification9, 10 (Figure (Figure1a).1a). The high fixed charge concentration in a BM configuration make them more suited in bioelectronic applications as compared to other non-linear ionic devices, such as diodes constructed from surface charged nanopores11 or nanochannels,12 as the latter devices typically suffers from reduced performance at elevated electrolyte concentration (i.e., at physiological conditions) due to reduced Debye screening length.13 However, a unique property of most BMs, as compared to the electronic PN-junction and other ionic diodes, is the electric field enhanced (EFE) water dissociation effect.10, 14 This occurs above a threshold reverse bias voltage, typically around −1 V, as the high electric field across the ion-depleted BM interface accelerates the forward reaction rate of the dissociation of water into H+ and OH ions. As these ions migrate out from the BM, there will be an increase in the reverse bias current. The EFE water dissociation is a very interesting effect and is commonly used in industrial electrodialysis applications,15 where highly efficient water dissociating BMs are being researched.16 Also, BMs have also been utilized to generate H+ and OH ions in lab-on-a-chip applications.2, 17 However, the EFE water dissociation effect diminishes the diode property of BMs when operated outside the ±1 V window, which is unwanted in, for instance, chemical circuits and addressing matrices for delivery of complex gradients of chemical species. The effect can be suppressed by incorporating a neutral electrolyte inside the BM,10, 18 for instance, poly(ethylene glycol) (PEG).2, 6, 7 However, as previously reported,2 the PEG volume will introduce hysteresis when switching from forward to reverse bias, due to its ability to store large amounts of charges. This was circumvented by ensuring that only H+ and OH are present in the diode, which recombines into water within the PEG volume. Such diodes are well suited as integrated components in chemical circuits for pH-regulation, due to the in situ formed H+ and OH, but are less attractive if, for instance, other ions, e.g., biomolecules, are to be processed or delivered in and from the circuit. Furthermore, a PEG electrolyte introduces additional patterning layers, making device downscaling more challenging. This is undesired when designing complex, miniaturized, and large-scale ionic circuits. Thus, there is an interest in BM diodes that intrinsically do not exhibit any EFE water dissociation, are easy to miniaturize, and that turn off at relatively high speeds. It has been suggested that tertiary amines in the BM interface are important for efficient EFE water dissociation,19, 20, 21 as they function as a weak base and can therefore catalyze dissociation of water by accepting a proton. For example, anion-selective membranes that have undergone complete methylation, converting all tertiary amines to quaternary amines, shows no EFE water dissociation,19 although this effect was not permanent, as the quaternization was reversed upon application of a current. Similar results were found for anion-selective membranes containing alkali-metal complexing crown ethers as fixed charges.21 Also, EFE water dissociation was not observed or reduced in BMs with poor ion selectivity, for example, in BMs with low fixed-charge concentration5 or with predominantly secondary and tertiary amines in the anion-selective membrane,22 as the increased co-ion transport reduces the electric field at the BM interface. However, due to decreased ion selectivity, these membranes show reduced rectification. In this work, we present a non-amine based BM diode that avoids EFE water dissociation, enables easy miniaturization, and provides fast turn-off speeds and high rectification.Open in a separate windowFigure 1(a) Ionic current rectification in a BM. In forward bias, mobile ions migrate towards the interface of the BM. The changing ion selectivity causes ion accumulation, resulting in high ion concentration and high conductivity. At high ion concentration, the selectivity of the membranes fails (Donnan exclusion failure), and ions start to pass the BM. In reverse bias, the mobile ions migrate away from the BM, eventually giving a zone with low ion concentration and low conductivity. Reverse bias can cause EFE water dissociation, producing H+ and OH- ions. (b) Chemical structures of PSS, qPVBC, and PVBPPh3. (c) The device used to characterize the BMs and the BM1A, BM2A, and BM1P designs. The BM interfaces are 50 × 50 μm.An anion-selective phosphonium-based polycation (poly(vinylbenzyl chloride) (PVBC) quaternized by triphenylphospine, PVBPPh3) was synthesized and compared to the ammonium-based polycation (PVBC quaternized by dimethylbenzylamine, qPVBC) previously used in BM diodes2 and transistors,7, 8 when included in BM diode structures together with polystyrenesulfonate (PSS) as the cation-selective material (Figure (Figure1b).1b). Three types of BM diodes were fabricated using standard photolithography patterning (Figure (Figure1c),1c), either with qPVBC (BM1A and BM2A) or PVBPPh3 (BM1P) as polycation and either with (BM2A) or without PEG (BM1A and BM1P). Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) electrodes covered with aqueous electrolytes were used to convert electronic input signals into ionic currents through the BMs, according to the redox reaction PEDOT+:PSS + M+ + e ↔ PEDOT0 + M+:PSS.The rectifying behavior of the diodes was evaluated using linear sweep voltammetry (Figure (Figure2).2). The BM1A diode exhibited an increase in the reverse bias current for voltages lower than −1 V, a typical signature of EFE water dissociation,10, 14 which decreased the current rectification at ±4 V to 6.14. No such deviation in the reverse bias current was observed for BM2A and BM1P, which showed rectification ratios of 751 and 196, respectively. In fact, for BM1P, no evident EFE water dissociation was observed even at −40 V (see inset of Figure Figure2).2). Thus, the PVBPPh3 polycation allows BM diodes to operate at voltages beyond the ±1 V window with maintained high ion current rectification.Open in a separate windowFigure 2Linear sweep voltammetry from −4 to +4 V (25 mV/s) for the BM diodes. The inset shows BM1P scanning from −40 V to +4 V (250 mV/s).The dynamic performance of the diodes was tested by applying a square wave pulse from reverse bias to a forward bias voltage of 4 V with 5–90 s pulse duration (Figure (Figure3).3). To access the amount of charge injected and extracted during the forward bias and subsequent turn off, the current through the device was integrated. For BM2A, we observed that the fall time increased with the duration of the forward bias pulse. This hysteresis is due to the efficient storage of ions in the large PEG volume, with no ions crossing the BM due to Donnan exclusion failure.2 As a result, during the initial period of the return to reverse bias, a large amount of charge needs to be extracted in order to deplete the BM. After a 90 s pulse, 90.6% of the injected charge during the forward bias was extracted before turn-off. This may be contrasted with BM1P, where the fall time is hardly affected by the pulse duration, and the extracted/injected ratio is only 15.4% for a 90 s pulse. For this type of BM, the interface quickly becomes saturated with ions during forward bias, leading to Donnan exclusion failure and transport of ions across the BM.4 Thus, less charge needs to be extracted to deplete the BM, allowing for faster fall times and significantly reduced hysteresis.Open in a separate windowFigure 3Switching characteristics (5, 10, 20, 30, 60, or 90 s pulse) and ion accumulation (at 90 s pulse) of the BM2A and BM1P diodes. BM1A showed similar characteristics as BM1P when switched at ±1V (see supplementary material).24Since the neutral electrolyte is no longer required to obtain high ion current rectification over a wide potential range, the size of the BM can be miniaturized. This translates into higher component density when integrating the BM diode into ionic/chemical circuits. A miniaturized BM1P diode was constructed, where the interface of the BM was shrunk from 50 μm to 10 μm. The 10 μm device showed similar IV and switching characteristics as before (Figure (Figure4),4), but with higher ion current rectification ratio (over 800) and decreased rise/fall times (corresponding to 90%/–10% of forward bias steady state) from 10 s/12.5 s to 4 s/4 s. Since the overlap area is smaller, a probable reason for the faster switching times is the reduced amount of ions needed to saturate and deplete the BM interface. In comparison to our previous reported low hysteresis BM diode,2 this miniaturized polyphosphonium-based devices shows the same rise and fall times but increased rectification ratio.Open in a separate windowFigure 4(a) Linear sweep voltammetry and (b) switching performance of a BM1P diode with narrow junction.In summary, by using polyphosphonium instead of polyammonium as the polycation in BM ion diodes the EFE water dissociation can be entirely suppressed over a large operational voltage window, supporting the theory that a weak base, such as a tertiary amine, is needed for efficient EFE water dissociation.17, 18 As no additional neutral layer at the BM interface is needed, ion diodes that operate outside the usual EFE water dissociation window of ±1 V can be constructed using less active layers, fewer processing steps and with relaxed alignment requirement as compared to polyammonium-based devices. This enables the fabrication of ion rectification devices with an active interface as low as 10 μm. Furthermore, the exclusion of a neutral layer improves the overall dynamic performance of the BM ion diode significantly, as there is less hysteresis due to ion accumulation. Previously, the hysteresis of BM ion diodes has been mitigated by designing the diode so that only H+ and OH enters the BM, which then recombines into water.2 Such diodes also show high ion current rectification ratio and switching speed but are more complex to manufacture, and their application in organic bioelectronic systems is limited due to the H+/OH production. By instead using the polyphosphonium-based BM diode, reported here, we foresee ionic, complex, and miniaturized circuits that can include charged biomolecules as the signal carrier to regulate functions and the physiology in cell systems, such as in biomolecule and drug delivery applications, and also in lab-on-a-chip applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号