 共查询到20条相似文献,搜索用时 31 毫秒
1.

Introduction

To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones.

Materials and methods

479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires.

Results

The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479 / 1307), 38% (228 / 598), and 36% (449 / 1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories.

Conclusions

Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.Key words: quality indicators, quality control, clinical laboratory services  相似文献   

2.

Introduction

In vitro human diagnostic (IVD) company recalls are a common practice aimed to either minimize a potential error or eliminate an existing failure. In this case report, we aim to provide a critical analysis of a recent IVD recall and to provide a practical framework about what to do when an IVD company recalls product(s) based on the International Organization for Standardization - ISO 15189:2012 standard.

Case report

In 2014, Abbott Laboratories® (Green Oaks, IL) published an urgent field safety notice regarding a product recall (Architect Intact parathyroid hormone (PTH) Assay List Number 8K25) with immediate action required. The IVD company explained the reasons for the recall as follows: i) Abbott has confirmed that a performance shift in the Architect Intact PTH assay has the potential to generate falsely elevated results on patient samples; ii) results generated with impacted lots may demonstrate a positive shift relative to those generated with previous reagent and/or calibrator lots. This issue may also impact established Architect Intact PTH reference ranges; iii) the magnitude of shift averages approximately 13% to 45%; iv) Abbott Architect Intact PTH controls do not detect the shift; and v) all current reagent, calibrator, and control inventory are impacted. The recall could have resulted in ~40,000 inaccurate laboratory tests reported by 18 laboratories from Italy (Lombardy region).

Conclusion

IVD company recalls have a serious impact on the patient safety and require a thorough investigation and responsible approach to minimize the possible damage. Medical laboratories accredited according to the ISO 15189 standard have procedures in place to manage such situations and ensure that patient safety is maintained when such recalls are issued.Key words: clinical laboratory techniques, patient safety, laboratory variability, reference standards, quality control, parathyroid hormone  相似文献   

3.

Introduction

Technological innovation requires the laboratories to ensure that modifications or incorporations of new techniques do not alter the quality of their results. In an ISO 15189 accredited laboratory, flexible scope accreditation facilitates the inclusion of these changes prior to accreditation body evaluation. A strategy to perform the validation of a biochemistry analyzer in an accredited laboratory having a flexible scope is shown.

Materials and methods:

A validation procedure including the evaluation of imprecision and bias of two Dimension Vista analysers 1500 was conducted. Comparability of patient results between one of them and the lately replaced Dimension RxL Max was evaluated. All studies followed the respective Clinical and Laboratory Standards Institute (CLSI) protocols. 30 chemistry assays were studied. Coefficients of variation, percent bias and total error were calculated for all tests and biological variation was considered as acceptance criteria. Quality control material and patient samples were used as test materials. Interchangeability of the results was established by processing forty patients’ samples in both devices.

Results:

27 of the 30 studied parameters met allowable performance criteria. Sodium, chloride and magnesium did not fulfil acceptance criteria. Evidence of interchangeability of patient results was obtained for all parameters except magnesium, NT-proBNP, cTroponin I and C-reactive protein.

Conclusions:

A laboratory having a well structured and documented validation procedure can opt to get a flexible scope of accreditation. In addition, performing these activities prior to use on patient samples may evidence technical issues which must be corrected to minimize their impact on patient results.  相似文献   

4.

Introduction

Poor harmonization of critical results management is present in various laboratories and countries, including Croatia. We aimed to investigate procedures used in critical results reporting in Croatian medical biochemistry laboratories (MBLs).

Materials and methods

An anonymous questionnaire, consisting of 24 questions/statements, related to critical results reporting procedures, was send to managers of MBLs in Croatia. Participants were asked to declare the frequency of performing procedures and degree of agreement with statements about critical values reporting using a Likert scale. Total score and mean scores for corresponding separate statements divided according to health care setting were calculated and compared.

Results

Responses from 111 Croatian laboratories (48%) were analyzed. General practice laboratories (GPLs) more often re-analyzed the sample before reporting the critical result in comparison with the hospital laboratories (HLs) (score: 4.86 (4.75-4.96) vs. 4.49 (4.25-4.72); P = 0.001) and more often reported the critical value exclusively to the responsible physician compared to HLs (4.46 (4.29-4.64) vs. 3.76 (3.48-4.03), P < 0.001). High total score (4.69 (4.56-4.82)) was observed for selection of the critical results list issued by the Croatian Chamber of Medical Biochemistry (CCMB) indicating a high harmonization level for this aspect of critical result management. Low total scores were observed for the statements regarding data recording and documentation of critical result notification.

Conclusions

Differences in practices about critical results reporting between HLs and GPLs were found. The homogeneity of least favorable responses detected for data recording and documentation of critical results notification reflects the lack of specific national recommendations.Key words: critical results, laboratory testing, quality indicators, survey, post-analytical phase  相似文献   

5.
6.

Introduction

Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia.

Materials and methods

An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions.

Results

The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein.

Conclusions

There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia.Key words: survey, chronic kidney disease, estimated glomerular filtration rate (eGFR), albuminuria, proteinuria, creatinine, harmonization  相似文献   

7.

Introduction:

The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia.

Materials and methods:

First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers.

Results:

Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively.

Conclusions:

Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.  相似文献   

8.

Introduction

This pilot study aimed to investigate the use of personal protective equipment (PPE) and compliance to the code of conduct (rules defined in institutional, governmental and professional guidelines) among laboratory technicians in Croatian medical laboratories. In addition, we explored the differences in compliance between participants of different age groups, laboratory ownership and accreditation status.

Materials and methods

An anonymous and voluntary survey with 15 questions was conducted among Croatian medical laboratory technicians (N = 217). The questions were divided into two groups: demographic characteristics and the use of PPE. The questions of the second part were graded according to the Likert scale (1-4) and an overall score, shown as median and range (min-max), was calculated for each participant. Differences between the overall scores were tested for each group of participants.

Results

The majority of participants always wear protective clothes at work, 38.7% of them always wear gloves in daily routine, more than 30.0% consume food and almost half of them drink beverages at workplace. A significantly lower overall score was found for participants working in public compared to private laboratories (36 (16-40) vs. 40 (31-40), P < 0.001). There were no statistically significant differences in overall scores for participants of different age groups (P = 0.456) and laboratory accreditation status (P = 0.081).

Conclusion

A considerable percentage of laboratory technicians in Croatian medical laboratories do not comply with safety measures. Lack of compliance is observed in all personnel regardless laboratory accreditation and participants’ age. However, those working in private laboratories adhere more to the code of conduct.Key words: survey, compliance, laboratory technician, universal safety measures, total quality management, clinical laboratory services  相似文献   

9.

Introduction:

Proper preparation of the individual is a key prerequisite for ensuring the quality of laboratory testing. Our hypothesis was that many outpatients are not sufficiently familiar with the correct way of preparing for the laboratory tests, for which the individual needs to be at fasting. This study aimed to investigate: i) whether patients are aware of how they need to prepare properly for laboratory tests; ii) the way in which users are informed about how to prepare for laboratory testing; and iii) whether users arrive to the laboratory for phlebotomy properly prepared.

Materials and methods:

An anonymous questionnaire was conducted on 150 outpatients older than 18 years, during February 2013. The response rate was 11%. All patients were interviewed by the laboratory staff. Patients were informed about detail of the questionnaire and agreed to participate in the survey.

Results:

Out of the total number subjects, 39% were fully aware of the proper definition of the fasting, whereas even 46% subjects replied that the last meal has to be taken the day before and the exact time that must pass after the last meal to blood sampling is not important. Furthermore, 52% subjects did not receive any information about how they need to prepare themselves properly for blood testing. Only 60% of them came properly prepared for the laboratory blood testing.

Conclusions:

Substantial proportion of patients do not come properly prepared for laboratory testing. We conclude that patients are not well informed about the fasting requirements for laboratory blood testing. Moreover, requesting physician is the preferred source of information from which patients learn how to prepare themselves for phlebotomy.  相似文献   

10.

Introduction

The study was performed to compare and analyze the inter-departmental variability in the request of rarely requested laboratory tests in primary care, as opposed to other more common and highly requested tests.

Materials and methods

Data from production statistics for the year 2012 from 76 Spanish laboratories was used. The number of antinuclear antibodies, antistreptolysin O, creatinine, cyclic citrullinated peptide antibodies, deaminated peptide gliadine IgA antibodies, glucose, protein electrophoresis, rheumatoid factor, transglutaminase IgA antibodies, urinalysis and uric acid tests requested was collected. The number of test requests per 1000 inhabitants was calculated. In order to explore the variability the coefficient of quartile dispersion was calculated.

Results

The smallest variation was seen for creatinine, glucose, uric acid and urinalysis; the most requested tests. The tests that were least requested showed the greatest variability.

Conclusion

Our study shows through a very simplified approach, in a population close to twenty million inhabitants, how in primary care, the variability in the request of laboratory tests is inversely proportional to the request rate.Key words: primary care, laboratory proficiency testing, clinical laboratory services, test requesting, preanalytical phase  相似文献   

11.
The practice of medical biochemistry in Slovenia includes clinical biochemistry (including toxicology, therapeutic drug monitoring, endocrinology, molecular diagnostics, immunology), hematology and coagulation. To start the vocational medical biochemistry training programme it's necessary to have a completed university degree (second cycle) in pharmacy, chemistry, biochemistry, medicine or other relevant university study and 1 year supervised practical training in medical laboratories, completed with mandatory state exam at Ministry of Health. The duration of vocational training programme is 4 years and is completed with final exam. The title after passed final examination is Medical biochemistry specialist. In October 2005 EC4 (Communities Confederation of Clinical Chemistry and Laboratory Medicine) approved Equivalence of standards of Slovenian national standards for medical biochemistry specialists. Since 2006 it is mandatory to be registered and to have valid license for medical biochemistry specialists and other professionals in laboratory medicine with at least university degree (second cycle) of education. Laboratory medicine in Slovenia is regulated globally through the Law of health-care activity and particularly through the Bylaw of laboratory medicine. The latter is based on standard ISO 15189, ratified in 2004. The Bylaw envisages granting working license to laboratories, valid for 5 years period. Granting of working licenses is ongoing process and first licenses have been granted in 2009. Important improvement toward the quality requirements for medical laboratories can be observed in the last 5 years. Parallel with the Bylaw of medical laboratories, Slovenian Accreditation (SA), the legal national accreditation body, started the initiative for accreditation of medical laboratories according to ISO 15189. It is in the implementation phase.  相似文献   

12.
13.

Introduction:

Serum blood collection tubes with separator gel are widely used by many laboratories for chemistry analyses. We describe a case of a primary blood collection tube filled with blood sample and a floating separator gel.

Materials and methods:

The blood sample was collected from a 51 years old female in intensive care unit with the diagnosis of pneumonia into a BD Vacutainer SST tube (Becton Dickinson, NJ, USA) containing serum separator gel and conveyed to the core laboratory of Marmara University Hospital within 30 minutes from collection. Sample was immediately centrifuged at room temperature at 1500 × g for 10 minutes.

Results:

The analyses revealed a highly increased total protein concentration of 145 g/L (reference interval 64–83 g/L). The nephelometric analyses showed an elevated serum IgG concentration of 108 g/L (reference interval 6.5–16 g/L) and IgG lambda monoclonal band was determined by serum immunofixation electrophoresis.

Conclusion:

Limitation of the separator gel tubes in patients with a high plasma density and its possible effects on test results and laboratory costs should be remembered. The clinical diagnosis stated in the information system should also reveal known comorbid conditions besides the apparent admission reason. This information would avoid resampling, additional testing, and communication efforts with the clinicians.  相似文献   

14.

Background

Early diagnosis is crucial for management of patients with suspected acute myocardial infarction (AMI). Among innovative and promising biomarkers, the recent interest raised on glycogen phosphorylase isoenzyme BB (GPBB) has prompted us to perform a meta-analysis of published studies.

Materials and methods:

A systematic electronic search was carried out on PubMed, Web of Science and Google Scholar, with no date restriction, to retrieve all articles that have investigated the early diagnostic performance of GPBB in patients with suspected AMI, and directly reported or allowed calculation of sensitivity and specificity. A meta-analysis of the reported sensitivity and specificity of each study and pooled area under the curve (AUC) was then performed by random effect approach. Heterogeneity was assessed by I-square statistics.

Results:

Eight studies were finally selected for analysis (941 subjects; 506 cases and 435 controls), with a high heterogeneity (I-squared, 86.3%). The resulting pooled estimates and 95% confidence interval were 0.854 (0.801–0.891) for sensitivity, 0.767 (0.713–0.815) for specificity, 0.826 (0.774–0.870) for negative predictive value, 0.802 (0.754–0.844) for positive predictive value, and 0.754 (0.602–0.907) for AUC. In those studies that have simultaneously assessed GPBB and a troponin immunoassay, the combination of these biomarkers did not significantly improve the performance of troponin alone.

Conclusion:

GPBB does not meet the current requirements for an efficient diagnosis of AMI when used as a stand-alone test, whereas its combination with troponin merits further investigation in larger trials.  相似文献   

15.

Introduction:

The activities involving phlebotomy, a critical task for obtaining diagnostic blood samples, are poorly studied as regards the major sources of errors and the procedures related to laboratory quality control. The aim of this study was to verify the compliance with CLSI documents of clinical laboratories from South America and to assess whether teaching phlebotomists to follow the exact procedure for blood collection by venipuncture from CLSI/NCCLS H03-A6 - Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture might improve the quality of the process.

Materials and methods:

A survey was sent by mail to 3674 laboratories from South America to verify the use of CLSI documents. Thirty skilled phlebotomists were trained with the CLSI H03-A6 document to perform venipuncture procedures for a period of 20 consecutive working days. The overall performances of the phlebotomists were further compared before and after the training program.

Results:

2622 from 2781 laboratories that did answer our survey used CLSI documents to standardize their procedures and process. The phlebotomists’ training for 20 days before our evaluation completely eliminated non-conformity procedures for: i) incorrect friction of the forearm, during the cleaning of the venipuncture site to ease vein location; ii) incorrect sequence of vacuum tubes collection; and iii) inadequate mixing of the blood in primary vacuum tubes containing anticoagulants or clot activators. Unfortunately the CLSI H03-A6 document does not caution against both unsuitable tourniquet application time (i.e., for more than one minute) and inappropriate request to clench the fist repeatedly. These inadequate procedures were observed for all phlebotomists.

Conclusion:

We showed that strict observance of the CLSI H03-A6 document can remarkably improve quality, although the various steps for collecting diagnostic blood specimens are not a gold standard, since they may still permit errors. Tourniquet application time and forearm clench should be verified by all quality laboratory managers in the services. Moreover, the procedure for collecting blood specimens should be revised to eliminate this source of laboratory variability and safeguard the quality.  相似文献   

16.

Introduction

Glycosylated hemoglobin (HbA1c) concentrations measured in clinical chemistry laboratories show large differences between their interlaboratory reported values. Laboratory measurements of quality performance should be based on quantitative data. The sigma metrics model provides an objective method for the assessment of current HbA1c assays and is useful in quality management planning. The aim of our study was to evaluate the analytical performance of the MQ-2000 PT HbA1c analyzer test results in the context of our operating conditions on the sigma scale.

Materials and methods

The coefficient of variation was determined from the calculated mean and standard deviation evaluated from internal quality control (QC) (N = 168 days) (Shanghai Huachen Biological Reagent Co. Ltd, China) data, and records of external quality data (KBUDEK, İstanbul, Turkey) measured in the period from May to November 2013 were used to determine the bias. The resulting data and total allowable error rate (TEA = 10%) from the Clinical Laboratory Improvement Amendments of 1988 (CLIA’88) were used to calculate the sigma level.

Results

The calculated coefficient of variations (CVs) at the two levels, normal (QC1 = 36.6 ± 2.38 mmol/mol) and pathological (QC2 = 84.7 ± 2.68 mmol/mol), were 6.5% and 3.1%, respectively. The average bias between the external QC and MQ-2000 PT during the study period was 4.3%. The calculated average sigma value was 1.19.

Conclusions

The MQ-2000 PT HbA1c is a new analyser in the market; there is need for improvement and the method should be controlled with greater attention to ensure quality.Key words: diabetes mellitus, hemoglobin A1c protein, human, chromatography, high pressure liquid chromatography  相似文献   

17.

Introduction:

We examined the cost-effectiveness of the three different D-dimer measurements in the screening of DVT in models with and without calculation of pre-test probability (PTP) score. Moreover, we calculated the minimal cost in DVT detection.

Material and methods:

In the group of 192 patients with clinically suspected acute DVT, we examined the three different D-dimer measurements (Innovance D-dimer, Hemosil D-dimer HS and Vidas D-dimer Exclusion II) in combination with and without PTP assessment.

Results:

The diagnostic alternative employing Vidas D-dimer Exclusion II assay without and with PTP calculation gave lower incremental cost-effectiveness ratio (ICER) than the alternative employing Hemosil D-dimer HS assay (0.187 Euros vs. 0.998 Euros per one additional DVT positive patient selected for CUS in model without PTP assessment and 0.450 vs. 0.753 Euros per one DVT positive patient selected for CUS in model with PTP assessment). According to sensitivity analysis, the Hemosil D-dimer HS assay was the most cost effective alternative when one patient was admitted to the vascular ambulance per day. Vidas D-dimer Exclusion II assay was the most cost effective alternative when more than one patient were admitted to the vascular ambulance per day. Cost minimisation analysis indicated that selection of patients according to PTP score followed by D-dimer analysis decreases the cost of DVT diagnosis.

Conclusions:

ICER analysis enables laboratories to choose optimal laboratory tests according to number of patients admitted to laboratory. Results support the feasibility of using PTP scoring and D-dimer measurement before CUS examination in DVT screening.  相似文献   

18.

Introduction:

Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory.

Materials and methods:

This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors.

Results:

A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients.

Conclusions:

The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.  相似文献   

19.

Introduction:

Capillary sampling is increasingly used to obtain blood for laboratory tests in volumes as small as necessary and as non-invasively as possible. Whether capillary blood sampling is also frequent in Croatia, and whether it is performed according to international laboratory standards is unclear.

Materials and methods:

All medical laboratories that participate in the Croatian National External Quality Assessment Program (N = 204) were surveyed on-line to collect information about the laboratory’s parent institution, patient population, types and frequencies of laboratory tests based on capillary blood samples, choice of reference intervals, and policies and procedures specifically related to capillary sampling. Sampling practices were compared with guidelines from the Clinical and Laboratory Standards Institute (CLSI) and the World Health Organization (WHO).

Results:

Of the 204 laboratories surveyed, 174 (85%) responded with complete questionnaires. Among the 174 respondents, 155 (89%) reported that they routinely perform capillary sampling, which is carried out by laboratory staff in 118 laboratories (76%). Nearly half of respondent laboratories (48%) do not have a written protocol including order of draw for multiple sampling. A single puncture site is used to provide capillary blood for up to two samples at 43% of laboratories that occasionally or regularly perform such sampling. Most respondents (88%) never perform arterialisation prior to capillary blood sampling.

Conclusions:

Capillary blood sampling is highly prevalent in Croatia across different types of clinical facilities and patient populations. Capillary sampling procedures are not standardised in the country, and the rate of laboratory compliance with CLSI and WHO guidelines is low.  相似文献   

20.
IntroductionEffective implementation and continual compliance with ISO 15189:2012 require ongoing commitment and active involvement of laboratory staff. Our aim was to assess attitudes regarding accreditation implementation by conducting a survey in three Croatian accredited medical laboratories.Materials and methodsAn anonymous survey consisting of 34 questions was distributed either electronically or in a paper form a week prior to scheduled annual audits. Distributions of answers regarding age, work experience, laboratory workplace, and education level and according to the respective laboratory were compared.ResultsThe overall response rate was 76% (225/297). Preference towards working in an accredited laboratory and a positive attitude were revealed by 70% and 56% participants, respectively, with better process documentation as the main advantage. Only 14% of responders considered themselves completely familiar with ISO 15189:2012. Total of 68% of responders felt that accreditation increases the usual workload, with excessive paperwork as the main contributor. Half of the responders declared partial agreement that accreditation requirements and expectations were clearly explained and claimed that their suggestions were taken into account only occasionally, which was especially emphasized by technical staff. The vast majority (89%) completely follow the prescribed protocols. Only 27% consider turnaround time monitoring useful. Competence assessment is considered efficient by 41% of responders. The majority (73%) prefer an online audit in times of COVID-19.ConclusionsDespite an overall positive attitude towards accreditation, further efforts are needed in providing better education about ISO 15189:2012 for technical staff and modifying formats of competence assessment, in order to achieve better adherence to ISO 15189:2012 requirements.  相似文献   