首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aims of this study were to determine if the primary time constant (tau) for oxygen uptake (VO2) at the onset of moderate-intensity treadmill exercise is related to endurance running performance, and to establish if tau could be considered a determinant of endurance running performance. Thirty-six endurance trained male runners performed a series of laboratory tests, on separate days, to determine maximal oxygen uptake (VO2max), the ventilatory threshold (VT) and running economy. In addition, runners completed six transitions from walking (4 km x h-1) to moderate-intensity running (80% VT) for the determination of the VO2 primary time constant and mean response time. During all tests, pulmonary gas-exchange was measured breath-by-breath. Endurance running performance was determined using a treadmill 5-km time-trial, after which runners were considered as combined performers (n=36) and, using a ranking system, high performers (n=10) and low performers (n=10). Relationships between tau and endurance running performance were quantified using correlation coefficients (r). Stepwise multiple regression was used to determine the primary predictor variables of endurance running performance in combined performers. Moderate correlations were observed between tau, mean response time and endurance running performance, but only for the combined performers (r=-0.55, P=0.001 and r=-0.50, P=0.002, respectively). The regression model for predicting 5-km performance did not include tau or mean response time. The velocity at VO2max was strongly correlated to endurance running performance in all groups (r=0.72 - 0.84, P < 0.01) and contributed substantially to the prediction of performance. In conclusion, the results suggest that despite their role in determining the oxygen deficit and having a moderate relationship with endurance running performance, neither tau nor mean response time is a primary determinant of endurance running performance.  相似文献   

2.
Twenty specialist marathon runners and 23 specialist ultra-marathon runners underwent maximal exercise testing to determine the relative value of maximum oxygen consumption (VO2max), peak treadmill running velocity, running velocity at the lactate turnpoint, VO2 at 16 km h-1, % VO2max at 16 km h-1, and running time in other races, for predicting performance in races of 10-90 km. Race time at 10 or 21.1 km was the best predictor of performance at 42.2 km in specialist marathon runners and at 42.2 and 90 km in specialist ultra-marathon runners (r = 0.91-0.97). Peak treadmill running velocity was the best laboratory-measured predictor of performance (r = -0.88(-)-0.94) at all distances in ultra-marathon specialists and at all distances except 42.2 km in marathon specialists. Other predictive variables were running velocity at the lactate turnpoint (r = -0.80(-)-0.92); % VO2max at 16 km h-1 (r = 0.76-0.90) and VO2max (r = 0.55(-)-0.86). Peak blood lactate concentrations (r = 0.68-0.71) and VO2 at 16 km h-1 (r = 0.10-0.61) were less good predictors. These data indicate: (i) that in groups of trained long distance runners, the physiological factors that determine success in races of 10-90 km are the same; thus there may not be variables that predict success uniquely in either 10 km, marathon or ultra-marathon runners, and (ii) that peak treadmill running velocity is at least as good a predictor of running performance as is the lactate turnpoint. Factors that determine the peak treadmill running velocity are not known but are not likely to be related to maximum rates of muscle oxygen utilization.  相似文献   

3.
The aim of this study was to determine which physiological variables predict excellence in middle- and long-distance runners. Forty middle-distance runners (age 23 ± 4 years, body mass 67.2 ± 5.9 kg, stature 1.80 ± 0.05 m, VO(2max) 65.9 ± 4.5 ml · kg(-1) · min(-1)) and 32 long-distance runners (age 25 ± 4 years, body mass 59.8 ± 5.1 kg, stature 1.73 ± 0.06 m, VO(2max) 71.6 ± 5.0 ml · kg(-1) · min(-1)) competing at international standard performed an incremental running test to exhaustion. Expired gas analysis was performed breath-by-breath and maximum oxygen uptake (VO(2max)) and two ventilatory thresholds (VT(1) and VT(2)) were calculated. Long-distance runners presented a higher VO(2max) than middle-distance runners when expressed relative to body mass (P < 0.001, d = 1.18, 95% CI [0.68, 1.68]). At the intensities corresponding to VT(1) and VT(2), long-distance runners showed higher values for VO(2) expressed relative to body mass or %VO(2max), speed and oxygen cost of running (P < 0.05). When oxygen uptake was adjusted for body mass, differences between groups were consistent. Logistic binary regression analysis showed that VO(2max) (expressed as l · min(-1) and ml · kg(-1) · min(-1)), VO(2VT2) (expressed as ml · kg(-0.94) · min(-1)), and speed at VT(2) (v(VT2)) categorized long-distance runners. In addition, the multivariate model correctly classified 84.7% of the athletes. Thus, VO(2max), VO(2VT2), and v(VT2) discriminate between elite middle-distance and long-distance runners.  相似文献   

4.
Endurance running performance in athletes with asthma   总被引:1,自引:0,他引:1  
Laboratory assessment was made during maximal and submaximal exercise on 16 endurance trained male runners with asthma (aged 35 +/- 9 years) (mean +/- S.D.). Eleven of these asthmatic athletes had recent performance times over a half-marathon, which were examined in light of the results from the laboratory tests. The maximum oxygen uptake (VO2max) of the group was 61.8 +/- 6.3 ml kg-1 min-1 and the maximum ventilation (VEmax) was 138.7 +/- 24.7 l min-1. These maximum cardio-respiratory responses to exercise were positively correlated to the degree of airflow obstruction, defined as the forced expiratory volume in 1 s (expressed as a percentage of predicted normal). The half-marathon performance times of 11 of the athletes ranged from those of recreational to elite runners (82.4 +/- 8.8 min, range 69-94). Race pace was correlated with VO2max (r = 0.863, P less than 0.01) but the highest correlation was with the running velocity at a blood lactate concentration of 2 mmol l-1 (r = 0.971, P less than 0.01). The asthmatic athletes utilized 82 +/- 4% VO2max during the half-marathon, which was correlated with the %VO2max at 2 mmol l-1 blood lactate (r = 0.817, P less than 0.01). The results of this study suggest that athletes with mild to moderate asthma can possess high VO2max values and can develop a high degree of endurance fitness, as defined by their ability to sustain a high percentage of VO2max over an endurance race. In athletes with more severe airflow obstruction, the maximum ventilation rate may be reduced and so VO2max may be impaired. The athletes in the present study have adapted to this limitation by being able to sustain a higher %VO2max before the accumulation of blood lactate, which is an advantage during an endurance race. Therefore, with appropriate training and medication, asthmatics can successfully participate in endurance running at a competitive level.  相似文献   

5.
The purpose of the present study was to assess fitness and running performance in a group of recreational runners (men, n = 18; women, n = 13). 'Fitness' was determined on the basis of their physiological and metabolic responses during maximal and submaximal exercise. There were strong correlations between VO2 max and treadmill running speeds equivalent to blood lactate concentrations of 2 mmol l-1 (V-2 mM) or 4 mmol l-1 (V-4 mM), 'relative running economy' and 5 km times (r = -0.84), but modest and non-significant correlations between muscle fibre composition and running performance. The results of the submaximal exercise tests suggested that the female runners were as well trained as the male runners. However, the men still recorded faster 5 km times (19.20 +/- 1.97 min vs 20.97 +/- 1.70 min; P less than 0.05). Therefore the of the present study suggest that the faster performance times recorded by the men were best explained by their higher VO2 max values, rather than their training status per se.  相似文献   

6.
Traditionally, it has been assumed that during middle-distance running oxygen uptake (VO2) reaches its maximal value (VO2max) providing the event is of a sufficient duration; however, this assumption is largely based on observations in individuals with a relatively low VO2max. The aim of this study was to determine whether VO2max is related to the VO2 attained (i.e. VO2peak) during middle-distance running on a treadmill. Fifteen well-trained male runners (age 23.3 +/- 3.8 years, height 1.80 +/- 0.10 m, body mass 76.9 +/- 10.6 kg) volunteered to participate in the study. The participants undertook two 800-m trials to examine the reproducibility of the VO2 response. These two trials, together with a progressive test to determine VO2max, were completed in a randomized order. Oxygen uptake was determined throughout each test using 15-s Douglas bag collections. Following the application of a 30-s rolling average, the highest VO2 during the progressive test (i.e. VO2max) was compared with the highest VO2 during the 800-m trials (i.e. VO2peak) to examine the relationship between VO2max and the VO2 attained in the 800-m trials. For the 15 runners, VO2max was 58.9 +/- 7.1 ml x kg(-1) x min(-1). Two groups were formed using a median split based on VO2max. For the high and low VO2max groups, VO2max was 65.7 +/- 3.0 and 52.4 +/- 1.8 ml x kg(-1) x min(-1) respectively. The limits of agreement (95%) for test-retest reproducibility for the VO2 attained during the 800-m trials were +/- 3.5 ml x kg(-1) x min(-1) for a VO2peak of 50.6 ml x kg(-1) x min(-1) (the mean VO2peak for the low VO2max group) and +/- 2.3 ml x kg(-1) x min(-1) for a VO2peak of 59.0 ml x kg(-1) x min(-1) (the mean VO2peak for the high VO2max group), with a bias in VO2peak between the 800-m runs (i.e. the mean difference) of 1.2 ml x kg(-1) x min(-1). The VO2peak for the 800-m runs was 54.8 +/- 4.9 ml x kg(-1) x min(-1) for all 15 runners. For the high and low VO2max groups, VO2peak was 59.0 +/- 3.3 ml x kg(-1) x min(-1) (i.e. 90% VO2max) and 50.6 +/- 2.0 ml x kg(-1) x min(-1) (i.e. 97% VO2max) respectively. The negative relationship (-0.77) between VO2max and % VO2max attained for all 15 runners was significant (P = 0.001). These results demonstrate that (i) reproducibility is good and (ii) that VO2max is related to the %VO2max achieved, with participants with a higher VO2max achieving a lower %VO2max in an 800-m trial on a treadmill.  相似文献   

7.
Previous studies have reported strong correlations between 5-km performance times and maximal oxygen uptake (VO2 max) and also for running speeds equivalent to blood lactate concentrations of 4 mM. However, there is little information on the physiological responses of individuals during races over this distance. Therefore, the aim of the present study was to measure the physiological and metabolic responses of endurance trained male (n = 8) and female (n = 8) runners during a 5-km time trial using an instrumented treadmill. Performance times were 18.77 +/- 1.27 min for the men and 21.80 +/- 1.98 min for the women (P less than 0.01). The corresponding times on the athletics track were 17.68 +/- 0.39 min for the men (P less than 0.05) and 20.70 +/- 2.16 min for the women (N.S.). During the treadmill time trials, both the men and women were able to utilize approximately 90% VO2 max, 82% VE max, 98% HR max and produce similar concentrations of blood lactate. Although the physiological and metabolic responses of these endurance-trained men and women to 5-km treadmill running were similar, the faster running times recorded by the men in this study were the result of their higher VO2 max values.  相似文献   

8.
Thirty-eight female subjects (M +/ SD = 33 +/- 3.0 years) had VO2max measured on the cycle ergometer (M +/- SD = 37.3 +/- 6.4 ml.kg-1.min-1) and on the treadmill (M +/- SD = 41.3 +/- 6.6 ml.kg-1.min-1). VO2max was estimated for each subject from heart rate (HR) at submaximal workloads on the cycle ergometer using the Astrand-Rhyming nomogram (A/R) and the extrapolation method (XTP). VO2max was also estimated from three field tests: 1.5-mile run (RUN) (independent variable [IV] = time), mile walk (WALK) (IV = time, age, HR, gender, body weight), and the Queens College Step Test (ST) (IV = HR during 5-20 s recovery). Repeated measure ANOVA revealed significant mean differences between the criterion cycle ergometer VO2max versus A/R and XTP (20 and 12% overestimation). The WALK, RUN, and ST VO2max values were not significantly different from the criterion treadmill VO2max. The correlation between criterion VO2max estimated from the WALK and RUN were r = .73 (SEE = 4.57 ml,kg-1.min-1) and r = .79 (SEE = 4.13 ml.kg-1.min-1), respectively. The ST, A/R, and XTP had higher SEEs (13-13.5% of the mean) and lower r s (r = .55 to r = .66). These results suggest both the WALK and RUN tests are satisfactory predictors of VO2max in 30 to 39-year-old females.  相似文献   

9.
The aim of this study was to determine the incidence of subject drop-out on a multi-stage shuttle run test and a modified incremental shuttle run test in which speed was increased by 0.014m.s-1 every 20-m shuttle to avoid the need for verbal speed cues. Analysis of the multi-stage shuttle run test with 208 elite female netball players and 381 elite male lacrosse players found that 13 (+/-3) players stopped after the first shuttle of each new level, in comparison with 5 (+/-2) players on any other shuttle. No obvious drop-out pattern was observed on the incremental shuttle run test with 273 male and 79 female undergraduate students. The mean difference between a test-retest condition (n= 20) for peak shuttle running speed (-0.03+/- 0.01m.s-1) and maximal heart rate (0.4+/- 0.1 beats.min-1) on the incremental test showed no bias (P > 0.05). The 95% absolute confidence limits of agreement were 0.11m.s-1 for peak shuttle running speed and +/-5 beats.min-1 for maximal heart rate. The relationship (n= 27) between peak shuttle running speed on the incremental shuttle run test (4.22+/- 0.14m.s-1) and VO2max (59.0+/- 1.7ml.kg-1.min-1) was r=0.91 (P< 0.01), with a standard error of prediction of 2.6ml.kg-1.min-1. These results suggest verbal cues during the multi-stage shuttle run test may influence subject drop-out. The incremental shuttle run test shows no obvious drop-out patten and provides a valid estimate of VO2max.  相似文献   

10.
The purposes of this study were to determine the relationships between: (a) measures of body size/composition and heat production/storage, and (b) heat production/storage and heart rate (HR) drift during running at 95% of the velocity that elicited lactate threshold, which was determined for 20 healthy recreational male runners. Subsequently, changes in skin and tympanic temperatures associated with a vigorous 20-min run, HR, and VO2 data were recorded. It was found that heat production was significantly correlated with body mass (r = .687), lean mass (r = .749), and body surface area (BSA, r = .699). Heat storage was significantly correlated with body mass (r = .519), fat mass (r = .464), and BSA (r = .498). The percentage of produced heat stored was significantly correlated with body mass (r = .427), fat mass (r = .455), and BSA (r = .414). Regression analysis showed that the sum of body mass, percentage of body fat, BSA, lean mass, and fat mass accounted for 30% of the variability in heat storage. It was also found that HR drift was significantly correlated with heat storage (r = .383), percentage of produced heat stored (r = .433), and core temperature change (r = .450). It was concluded that heavier runners experienced greater heat production, heat storage, and core temperature increases than lighter runners during vigorous running.  相似文献   

11.
Comparison of maximal anaerobic running tests on a treadmill and track   总被引:1,自引:0,他引:1  
To develop a track version of the maximal anaerobic running test, 10 sprint runners and 12 distance runners performed the test on a treadmill and on a track. The treadmill test consisted of incremental 20-s runs with a 100-s recovery between the runs. On the track, 20-s runs were replaced by 150-m runs. To determine the blood lactate versus running velocity curve, fingertip blood samples were taken for analysis of blood lactate concentration at rest and after each run. For both the treadmill and track protocols, maximal running velocity (v max), the velocities associated with blood lactate concentrations of 10 mmol x l-1 (v10 mM) and 5 mmol x l(-1) (v5 mM), and the peak blood lactate concentration were determined. The results of both protocols were compared with the seasonal best 400-m runs for the sprint runners and seasonal best 1000-m time-trials for the distance runners. Maximal running velocity was significantly higher on the track (7.57 +/- 0.79 m x s(-1)) than on the treadmill (7.13 +/- 0.75 m x s(-1)), and sprint runners had significantly higher vmax, v10 mM, and peak blood lactate concentration than distance runners (P < 0.05). The Pearson product--moment correlation coefficients between the variables for the track and treadmill protocols were 0.96 (v max), 0.82 (v10 mM), 0.70 (v5 mM), and 0.78 (peak blood lactate concentration) (P < 0.05). In sprint runners, the velocity of the seasonal best 400-m run correlated positively with vmax in the treadmill (r = 0.90, P < 0.001) and track protocols (r = 0.92, P < 0.001). In distance runners, a positive correlation was observed between the velocity of the 1000-m time-trial and vmax in the treadmill (r = 0.70, P < 0.01) and track protocols (r = 0.63, P < 0.05). It is apparent that the results from the track protocol are related to, and in agreement with, the results of the treadmill protocol. In conclusion, the track version of the maximal anaerobic running test is a valid means of measuring different determinants of sprint running performance.  相似文献   

12.
The purpose of this study was threefold: to determine (a) the test-retest reliability of the 20-m shuttle test (20 MST) (number of laps), (b) the concurrent validity of the 20 MST (number of laps), and (c) the validity of the prediction equation for VO2max developed by Léger, Mercier, Gadoury, and Lambert (1988) on Canadian children for use with American children 12-15 years old. An intraclass coefficient of .93 was obtained on 20 students (12 males; R = .91 and 8 females; R = .87) who completed the test twice, 1 week apart (MT1 = 47.80 +/- 20.29 vs. MT2 = 50.55 +/- 22.39 laps; p > or = .13). VO2peak was obtained by a treadmill test to volitional fatigue on 48 subjects. The number of laps run correlated significantly with VO2peak in males (n = 22; r = .65; F [1, 20] = 14.30 p < or = .001), females (n = 26; r = .51; F [1, 24] = 8.34; p < or = .01), and males and females = (r = .69; F [1, 46] = 42.54, p < or = .001). When the measured VO2peak (M = 49.97 +/- 7.59 ml.kg-1.min-1) was compared with the estimated VO2max (M = 48.72 +/- 5.72 ml.kg-1.min-1) predicted from age and maximal speed of the 20 MST (Léger et al., 1988) no significant difference was found, t (47) = -1.631; p > or = .11, between the means; the r was .72 and SEE was 5.26 ml.kg-1.min-1.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
The aims of this study were to determine if there are significant kinematic changes in running pattern after intense interval workouts, whether duration of recovery affects running kinematics, and whether changes in running economy are related to changes in running kinematics. Seven highly trained male endurance runners (VO 2max = 72.3 +/- 3.3 ml kg -1 min -1 ; mean +/- s) performed three interval running workouts of 10 X 400 m at a speed of 5.94 +/- 0.19 m s -1 (356 +/- 11.2 m min -1 ) with a minimum of 4 days recovery between runs. Recovery of 60, 120 or 180 s between each 400 m repetition was assigned at random. Before and after each workout, running economy and several kinematic variables were measured at speeds of 3.33 and 4.47 m s -1 (200 and 268 m min -1 ). Speed was found to have a significant effect on shank angle, knee velocity and stride length (P ? 0.05). Correlations between changes pre- and post-test for VO 2 (ml kg -1 min -1 ) and several kinematic variables were not significant (P > 0.05) at both speeds. In general, duration of recovery was not found to adversely affect running economy or the kinematic variables assessed, possibly because of intra-individual adaptations to fatigue.  相似文献   

14.
The aims of the study were to describe the physiological profile of a 65-km (4000-m cumulative elevation gain) running mountain ultra-marathon (MUM) and to identify predictors of MUM performance. Twenty-three amateur trail-runners performed anthropometric evaluations and an uphill graded exercise test (GXT) for VO2max, ventilatory thresholds (VTs), power outputs (PMax, PVTs) and heart rate response (HRmax, HR@VTs). Heart rate (HR) was monitored during the race and intensity was expressed as: Zone I (VT2) for exercise load calculation (training impulse, TRIMP). Mean race intensity was 77.1%±4.4% of HRmax distributed as: 85.7%±19.4% Zone I, 13.9%±18.6% Zone II, 0.4%±0.9% Zone III. Exercise load was 766±110 TRIMP units. Race time (11.8±1.6h) was negatively correlated with VO2max (r = ?0.66, <0.001) and PMax (r = ?0.73, <0.001), resulting these variables determinant in predicting MUM performance, whereas exercise thresholds did not improve performance prediction. Laboratory variables explained only 59% of race time variance, underlining the multi-factorial character of MUM performance. Our results support the idea that VT1 represents a boundary of tolerable intensity in this kind of events, where exercise load is extremely high. This information can be helpful in identifying optimal pacing strategies to complete such extremely demanding MUMs.  相似文献   

15.
The purpose of this study was to develop a submaximal, 1.5-mile endurance test for college-aged students using walking, jogging, or running exercise. College students (N = 101: 52 men, 47 women), ages 18-26years, successfully completed the 1.5-mile test twice, and a maximal graded exercise test. Participants were instructed to achieve a "somewhat hard" exercise intensity (rating of perceived exertion = 13) and maintain a steady pace throughout each 1.5-mile test. Multiple linear regression generated the following prediction equation: VO2 max = 65.404 + 7.707 x gender (1 = male; 0 =female) - 0.159 x body mass (kg) - 0.843 x elapsed exercise time (min; walking, jogging orrunning). This equation shows acceptable validity (R = .86, SEE = 3.37 ml x kg(-1) min(-1)) similar to the accuracy of comparable field tests, and reliability (ICC = .93) is also comparable to similar models. The statistical shrinkage is minimal (R(press) = 0.85, SEE(press) = 3.51 ml x kg(-) x min(-1)); hence, it should provide comparable results when applied to other similar samples. A regression model (R =.90, and SEE = 2.87 ml x kg(-1) min(-1)) including exercise heart rate was also developed: VO2 max = 100.162 +/- 7.301 x gender(1 = male; 0 =female) - 0.164 x body mass (kg) - 1.273 x elapsed exercise time -0.156 x exercise heart rate, for those who have access to electronic heart rate monitors. This submaximal 1.5-mile test accurately predicts maximal oxygen uptake (VO2max) without measuring heart rate and is similar to the 1.5-mile run in that it allowsfor mass testing and requires only a flat, measured distance and a stopwatch. Further, it can accommodate a wide range of fitness levels (from walkers to runners).  相似文献   

16.
The aims of this study were to determine if there are significant kinematic changes in running pattern after intense interval workouts, whether duration of recovery affects running kinematics, and whether changes in running economy are related to changes in running kinematics. Seven highly trained male endurance runners (VO2max = 72.3+/-3.3 ml x kg(-1) x min(-1); mean +/- s) performed three interval running workouts of 10 x 400 m at a speed of 5.94+/-0.19 m x s(-1) (356+/-11.2 m x min(-1)) with a minimum of 4 days recovery between runs. Recovery of 60, 120 or 180 s between each 400 m repetition was assigned at random. Before and after each workout, running economy and several kinematic variables were measured at speeds of 3.33 and 4.47 m x s(-1) (200 and 268 m x min(-1)). Speed was found to have a significant effect on shank angle, knee velocity and stride length (P < 0.05). Correlations between changes pre- and post-test for VO2 (ml x kg(-1) x min(-1)) and several kinematic variables were not significant (P > 0.05) at both speeds. In general, duration of recovery was not found to adversely affect running economy or the kinematic variables assessed, possibly because of intra-individual adaptations to fatigue.  相似文献   

17.
The aim of this study was to compare the evolution of oxygen uptake (VO2) in specifically trained runners during running tests based on the 400-, 800-, and 1500-m pacing strategies adopted by elite runners to optimize performance. Final velocity decreased significantly for all three distances, with the slowest velocity in the last 100 m expressed relative to the peak velocity observed in the 400 m (77%), 800 m (88%), and 1500 m (96%). Relative to the previously determined VO2max values, the respective VO 2peak corresponded to 94% (400 m) and 100% (800 and 1500 m). In the last 100 m, a decrease in VO2 was observed in all participants for the 400-m (15.6 ± 6.5%) and 800-m races (9.9 ± 6.3%), whereas a non-systematic decrease (3.6 ± 7.6%) was noted for the 1500 m. The amplitude of this decrease was correlated with the reduction in tidal volume recorded during the last 100 m of each distance (r = 0.85, P < 0.0001) and with maximal blood lactate concentrations after the three races (r = 0.55, P < 0.005). The present data demonstrate that the 800 m is similar to the 400 m in terms of decreases in velocity and VO2.  相似文献   

18.
The aim of the present study was to determine the repeatability of a running endurance test using an automated treadmill system that requires no manual input to control running speed. On three separate occasions, 7 days apart, 10 experienced male endurance-trained runners (mean age 32 years, s = 10; VO2peak 61 ml x kg(-1) x min(-1), s = 7) completed a treadmill time trial, in which they were instructed to run as far as possible in 60 min. The treadmill was instrumented with an ultrasonic feedback-controlled radar modulator that spontaneously regulated treadmill belt speed corresponding to the changing running speed of each runner. Estimated running intensity was 70% VO2peak (s = 11) and the distance covered 13.5 km (s = 2), with no difference in mean performances between trials. The coefficient of variation, estimated using analysis of variance, with participant and trial as main effects, was 1.4%. In summary, the use of an automated treadmill system improved the repeatability of a 60-min treadmill time trial compared with time trials in which speed is controlled manually. The present protocol is a reliable method of assessing endurance performance in endurance-trained runners.  相似文献   

19.
In 219 recreational male runners, we investigated changes in body mass, total body water, haematocrit, plasma sodium concentration ([Na(+)]), and urine specific gravity as well as fluid intake during a 100-km ultra-marathon. The athletes lost 1.9 kg (s = 1.4) of body mass, equal to 2.5% (s = 1.8) of body mass (P < 0.001), 0.7 kg (s = 1.0) of predicted skeletal muscle mass (P < 0.001), 0.2 kg (s = 1.3) of predicted fat mass (P < 0.05), and 0.9 L (s = 1.6) of predicted total body water (P < 0.001). Haematocrit decreased (P < 0.001), urine specific gravity (P < 0.001), plasma volume (P < 0.05), and plasma [Na(+)] (P < 0.05) all increased. Change in body mass was related to running speed (r = -0.16, P < 0.05), change in plasma volume was associated with change in plasma [Na(+)] (r = -0.28, P < 0.0001), and change in body mass was related to both change in plasma [Na(+)] (r = -0.36) and change in plasma volume (r = 0.31) (P < 0.0001). The athletes consumed 0.65 L (s = 0.27) fluid per hour. Fluid intake was related to both running speed (r = 0.42, P < 0.0001) and change in body mass (r = 0.23, P = 0.0006), but not post-race plasma [Na(+)] or change in plasma [Na(+)] (P > 0.05). In conclusion, faster runners lost more body mass, runners lost more body mass when they drank less fluid, and faster runners drank more fluid than slower runners.  相似文献   

20.
The aim of this study was to objectively quantify ratings of perceived enjoyment using the Physical Activity Enjoyment Scale following high-intensity interval running versus moderate-intensity continuous running. Eight recreationally active men performed two running protocols consisting of high-intensity interval running (6 × 3 min at 90% VO(2max) interspersed with 6 × 3 min active recovery at 50% VO(2max) with a 7-min warm-up and cool down at 70% VO(2max)) or 50 min moderate-intensity continuous running at 70% VO(2max). Ratings of perceived enjoyment after exercise were higher (P < 0.05) following interval running compared with continuous running (88 ± 6 vs. 61 ± 12) despite higher (P < 0.05) ratings of perceived exertion (14 ± 1 vs. 13 ± 1). There was no difference (P < 0.05) in average heart rate (88 ± 3 vs. 87 ± 3% maximum heart rate), average VO(2) (71 ± 6 vs. 73 ± 4%VO(2max)), total VO(2) (162 ± 16 vs. 166 ± 27 L) or energy expenditure (811 ± 83 vs. 832 ± 136 kcal) between protocols. The greater enjoyment associated with high-intensity interval running may be relevant for improving exercise adherence, since running is a low-cost exercise intervention requiring no exercise equipment and similar relative exercise intensities have previously induced health benefits in patient populations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号