首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到13条相似文献,搜索用时 15 毫秒
1.
Abstract

The aim was to assess the technical variability of a new wrist-worn accelerometer under controlled conditions with a shaker device and during normal daily physical activities (PAs). In the first experiment, 10 wrist-worn accelerometers (Vivago® Wellness, Paris, France) were attached to the shaker device. Variability was tested at five shaking frequencies (1.1, 2.1, 3.1, 4.1, and 10 Hz) for 10 min at each frequency. In the second experiment, 21 participants wore wrist-worn accelerometers and performed six consecutive 10-min periods of activity at increasing levels of intensity from sedentary to vigorous. Results from the first experiment show a modest inter- and intra-instrument reliability at low frequencies and that reliability improved as frequency increased. The inter-instrument coefficient of variation (CV) was 2.6–18.3%. The intra-instrument CV was 4.1–23.2%. Variability was similar in the second experiment with a CV inversely related to PA intensity. The inter- and intra-instrument CV varied from 24.2% and 19.9% for sedentary activities to 3.7% and 4.3% for vigorous PA, respectively. Results suggest that reliability was higher at high intensities, corresponding to moderate and vigorous PA, intensities generally recommended for public health purposes.  相似文献   

2.
This study investigated the effects of combined sleep deprivation and strenuous exercise on cognitive and neurobehavioral performance among long-distance runners completing one of the most difficult ultramarathons in the world. Seventeen runners participated. Each had a wrist-worn actigraph throughout the race to record their sleep time. In addition, each individual’s performance in 10-min response-time tests before and after the race was recorded and a questionnaire enabled participants to report any difficulties they experienced during the competition. During race completion times of 27 to 44 h, combined acute lack of sleep (12 ± 17 min of rest during the race) and strenuous exercise (168.0 km) had marked adverse effects on cognitive performances ranging from mere lengthening of response time to serious symptoms such as visual hallucinations. This study suggests that regardless of rest duration and time in race, cognitive performances of ultramarathoners are adversely affected.  相似文献   

3.
Abstract

Spinning is a type of indoor fitness activity performed on stationary bikes by participants who pedal together to the rhythm of music and the motivating words of an instructor. Despite worldwide popularity of this type of recreational activity, to date there have been few, mainly non-scientific, studies of the impact of spinning on metabolic, respiratory, and cardiovascular functions. The main aim of this study was to evaluate a number of metabolic and cardiovascular variables during a standard 50-min class performed by Spinning® instructors of both sexes: six males (age 30 ± 4.8 years, body mass index 24 ± 2.5 kg · m?2; mean ± s) and six females (age 34 ± 6.3 years, body mass index 21 ± 1.9 kg · m?2). The mean power output, heart rate, and oxygen uptake during the performance were 120 ± 4 W, 136 ± 13 beats · min?1, and 32.8 ± 5.4 ml · kg?1 · min?1 respectively for males, and 73 ± 43 W, 143 ± 25 beats · min?1, and 30 ± 9.9 ml · kg?1 · min?1 respectively for females. Analysis of individual performances showed that they were compatible with physical exercise that ranged from moderate-to-heavy to very heavy, the latter conditions prevailing. The results show that this type of fitness activity has a high impact on cardiovascular function and suggest that it is not suitable for unfit or sedentary individuals, especially the middle aged or elderly, who are willing to begin a recreational physical activity programme.  相似文献   

4.
Accelerometer-based systems are often used to quantify human movement. This study’s aim was to assess the reliability and validity of the Myotest® accelerometer-based system for measuring running stride kinematics. Twenty habitual runners ran two 60 m trials at 12, 15, 18 and 21 km·h?1. Contact time, aerial time and step frequency parameters from six consecutive running steps of each trial were extracted using Myotest® data. Between-trial reproducibility of measures was determined by comparing kinematic parameters from the two runs performed at the same speed. Myotest® measures were compared against photocell-based (Optojump Next®) and high-frequency video data to establish concurrent validity. The Myotest®-derived parameters were highly reproducible between trials at all running speeds (intra-class correlation coefficient (ICC): 0.886 to 0.974). Compared to the photo-cell and high-speed video-based measures, the mean contact times from the Myotest® were 34% shorter and aerial times were 64% longer. Only step frequency was comparable between systems and demonstrated high between-system correlation (ICC ≥ 0.857). The Myotest® is a practical portable device that is reliable for measuring contact time, aerial time and step frequency during running. In terms of validity, it provides accurate step frequency measures but underestimates contact time and overestimates aerial time compared to photocell- and optical-based systems.  相似文献   

5.
The purposes of this study were to determine (a) the test-retest reliability of cardiorespiratory responses to exercise performed on the StairMaster 4000PT® (SM-4000) and (b) the validity of the SM-4000 for estimating oxygen consumption (VO2) based on final SM-4000 stepping speed. Sixty-one participants (30 men, 31 women) performed two graded exercise tests separated by 6 to 8 days. Participants began stepping at the lowest intensity stage (26 steps/min-1) and intensity was increased by 1 stage each minute (8-9 steps/min-1) until volitional exhaustion or until maximal stepping speed was reached (138 steps/min-1). SM-4000-generated VO2 (SMVO2), measured VO2 (MVO2), heart rate, respiratory exchange ratio, and ratings of perceived exertion were measured during each minute of the test. Intraclass (Rxx') and interclass (rxx') reliability coefficients were high for both men and women for all variables (Rxx' ≥ .91 and rxx' ≥ .83 for men, Rxx' ≥ .92 and rxx' ≥ .88 for women). Estimated reliability coefficients from a single administration of the test based on intraclass reliability were high for all variables for both sexes (Rxx' ≥ .83). Standard errors of measurement for SMVO2 and MVO2 indicate these variables are reproducible within small ranges of variation. High concurrent validity coefficients for men and women (rxx' = .87 and .92, respectively) and small Standard Errors of Estimate (2.3 and 2.2 ml middot; kg-1 min-1, respectively), indicate a high correlation exists between SMVO2 and MVO2. However, significant differences between group means for SMVO2 and MVO2 occurred for men (44.3 vs. 37.9 ml · kg-1 · min-1, p < .0001) and women (41.3 vs. 33.2 ml · kg-1 · min -1, p < .0001). This, coupled with large total error values (6.9 and 8.5 ml · kg -1 · min-1 for...  相似文献   

6.
We compared SenseWear Armband versions (v) 2.2 and 5.2 for estimating energy expenditure in healthy adults. Thirty-four adults (26 women), 30.1 ± 8.7 years old, performed two trials that included light-, moderate- and vigorous-intensity activities: (1) structured routine: seven activities performed for 8-min each, with 4-min of rest between activities; (2) semi-structured routine: 12 activities performed for 5-min each, with no rest between activities. Energy expenditure was measured by indirect calorimetry and predicted using SenseWear v2.2 and v5.2. Compared to indirect calorimetry (297.8 ± 54.2 kcal), the total energy expenditure was overestimated (P < 0.05) by both SenseWear v2.2 (355.6 ± 64.3 kcal) and v5.2 (342.6 ± 63.8 kcal) during the structured routine. During the semi-structured routine, the total energy expenditure for SenseWear v5.2 (275.2 ± 63.0 kcal) was not different than indirect calorimetry (262.8 ± 52.9 kcal), and both were lower (P < 0.05) than v2.2 (312.2 ± 74.5 kcal). The average mean absolute per cent error was lower for the SenseWear v5.2 than for v2.2 (P < 0.001). SenseWear v5.2 improved energy expenditure estimation for some activities (sweeping, loading/unloading boxes, walking), but produced larger errors for others (cycling, rowing). Although both algorithms overestimated energy expenditure as well as time spent in moderate-intensity physical activity (P < 0.05), v5.2 offered better estimates than v2.2.  相似文献   

7.
The purpose of this study was to gain a holistic understanding of the efficacy of Zumba® fitness in a community-recruited cohort of overweight and physically inactive women by evaluating (i) its physiological effects on cardiovascular risk factors and inflammatory biomarkers and (ii) its mental health-enhancing effects on factors of health-related quality of life (HRQoL). Participants were randomly assigned to either engagement in one to two 1 h classes of Zumba® fitness weekly (intervention group; n = 10) or maintenance of habitual activity (control group; n = 10). Laboratory assessments were conducted pre- (week 0) and post-intervention (week 8) with anthropometric, physiological, inflammatory and HRQoL data collected. In the intervention group, maximal oxygen uptake significantly increased (P < 0.05; partial η2 = 0.56) by 3.1 mL · kg?1 · min?1, per cent body fat significantly decreased (P < 0.05; partial η2 = 0.42) by –1.2%, and interleukin-6 and white blood cell (WBC) count both significantly decreased (P < 0.01) by –0.4 pg · mL?1 (partial η2 = 0.96) and –2.1 × 109 cells · L?1 (partial η2 = 0.87), respectively. Large magnitude enhancements were observed in the HRQoL factors of physical functioning, general health, energy/fatigue and emotional well-being. When interpreted in a community-based physical activity and psychosocial health promotion context, our data suggest that Zumba® fitness is indeed an efficacious health-enhancing activity for adults.  相似文献   

8.
Abstract

The purpose of this study was to determine the validity and reliability of a new method for measuring three-dimensional (3D) putting stroke kinematics using the TOMI® device. A putting robot and a high-speed camera were used to simultaneously collect data for the validity evaluation. The TOMI® device, when used in conjunction with standard 3D coordinate data processing techniques, was found to be a valid and reliable method for measuring face angle, stroke path, putter speed, and impact spot at the moment of ball contact. The validity of the TOMI® measurement system was quantified using the 95% limits of agreement method for each aforementioned variable. The practical significance of each validity score was assessed by incorporating the maximum estimated measurement error into the stroke of the putting robot for 10 consecutive putts. All putts were executed from a distance of 4 m on a straight and flat synthetic putting surface. Since all putts were holed successfully, the measurement error for each variable was deemed to be negligible for the purposes of measuring putting stroke kinematics. The influence of key kinematic errors, at impact, on the outcome of a putt was also determined.  相似文献   

9.
Cost effective, quantifiable assessment of lower extremity movement represents potential improvement over standard tools for evaluation of injury risk. Ten healthy participants completed three trials of a drop jump, overhead squat, and single leg squat task. Peak hip and knee kinematics were assessed using an 8 camera BTS Smart 7000DX motion analysis system and the Microsoft Kinect® camera system. The agreement and consistency between both uncorrected and correct Kinect kinematic variables and the BTS camera system were assessed using interclass correlations coefficients. Peak sagittal plane kinematics measured using the Microsoft Kinect® camera system explained a significant amount of variance [Rangehip = 43.5–62.8%; Rangeknee = 67.5–89.6%] in peak kinematics measured using the BTS camera system. Across tasks, peak knee flexion angle and peak hip flexion were found to be consistent and in agreement when the Microsoft Kinect® camera system was directly compared to the BTS camera system but these values were improved following application of a corrective factor. The Microsoft Kinect® may not be an appropriate surrogate for traditional motion analysis technology, but it may have potential applications as a real-time feedback tool in pathological or high injury risk populations.  相似文献   

10.
Force plates represent the “gold standard” in measuring running kinetics to predict performance or to identify the sources of running-related injuries. As these measurements are generally limited to laboratory analyses, wireless high-quality sensors for measuring in the field are needed. This work analysed the accuracy and precision of a new wireless insole forcesensor for quantifying running-related kinetic parameters. Vertical ground reaction force (GRF) was simultaneously measured with pit-mounted force plates (1?kHz) and loadsol® sensors (100?Hz) under unshod forefoot and rearfoot running-step conditions. GRF data collections were repeated four times, each separated by 30 min treadmill running, to test influence of extended use. A repeated-measures ANOVA was used to identify differences between measurement devices. Additionally, mean bias and Bland–Altman limits of agreement (LoA) were calculated. We found a significant difference (p?® devices for these parameters. For these same parameters, the LoA analysis showed that 95% of all measurement differences between insole and force plate measurements were less than 12%, demonstrating high precision of the sensors. However, highly dynamic behaviour of GRF, such as force rate, is not yet sufficiently resolved by the insole devices, which is likely explained by the low sampling rate.  相似文献   

11.
The objectives were to compare the metabolic load elicited by Zumba® classes and DVD workouts and link the physiological responses to participants’ psychological characteristics. Fifteen women (25.4 ± 4.3 years old; 164.9 ± 5.1 cm; 56.9 ± 5.8 kg; 23.9 ± 4.9% body fat) performed three Zumba® classes and three Zumba® DVD workouts using a repeated measure design. Energy expenditure was assessed by extrapolating oxygen cost from heart rate (HR) using regressions from a preliminary incremental running test. Differences between Zumba® classes and Zumba® DVD workouts were assessed by Student’s T tests and repeated measures analysis of variance and correlations between physiological and psychological variables by the Pearson’s coefficient. Results showed that Zumba® classes allowed greater energy expenditure compared to Zumba® DVD workouts (6.8 ± 0.9 vs 5.6 ± 0.9 kcal · min?1, 95% confidence interval (CI) limits: 0.3–2.1, = 0.016), with significant differences in the time spent with a HR above 85% of HR reserve (14.7 vs 1.7%, 95% CI: 5.6–20.4, = 0.021). Furthermore, women with a greater autonomy score showed a smaller difference between DVD and class (r = 0.511, = 0.048), while greater differences were shown in women with greater interpersonal skills (r = ?0.563, = 0.028). The results suggest that while both types of workouts are suitable to maintain fitness Zumba® classes allow greater energy expenditure.  相似文献   

12.
The study compared the agreement, internal consistency, and measurement stability of the GE iDXA, BOD POD, and InBody 720. Body composition of 43 men and 37 women (31.4 ± 10.7 years; 90% Caucasian and 10% other) was assessed in triplicate using each method over two different days. Mean percent body fat (% BF) of the participants was different for all three machines (27.6 ± 10.0% [GE iDXA)] 25.6 ± 10.4% [BOD POD], and 21.3 ± 10.6% [InBody 720]; p < .05). The coefficient of variation for same day repeated measures was 1.06% (GE iDXA), 3.29% (BOD POD), and 2.97% (InBody 720). The coefficient of variation for 2-day repeated measures was 1.81% (GE iDXA), 4.61% (BOD POD), and 4.24% (InBody 720). The difference between the GE iDXA and BOD POD was within acceptable variability, while the InBody 720 significantly underestimated % BF. The internal consistency was highest for the GE iDXA, followed by the InBody 720, and then the BOD POD.  相似文献   

13.
We compared the effectiveness of topical ketoprofen in Transfersome® gel (IDEA-033) with oral ketoprofen and drug-free Sequessome? vesicles (FLEXISEQ® Sport; TDT 064) in reducing calf muscle soreness. One hundred and sixty eight healthy individuals with a pain score ≥3 (10-point scale) 12–16 h post-exercise (walking down stairs with an altitude of 300–400 m) were randomised to receive IDEA-033 plus oral placebo (two dose groups), oral ketoprofen plus TDT 064, or TDT 064 plus oral placebo. The primary endpoint was muscle soreness reduction from pre-dosing to Day 7. Higher pain scores were recorded with oral ketoprofen plus TDT 064 (mean ± s 462.4 ± 160.4) versus IDEA-033 plus oral placebo (434.7 ± 190.8; = 0.2931) or TDT 064 plus oral placebo (376.2 ± 159.1; P = 0.0240) in the 7 days post-exercise. Recovery from muscle soreness was longer with oral ketoprofen plus TDT 064 (mean 91.0 ± 19.5 h) versus IDEA-033 plus placebo (mean 81.4 ± 22.9 h; P = 0.5964) or TDT 064 plus placebo (mean 78.9 ± 22.8 h; P = 0.0262). In conclusion, ultradeformable phospholipid vesicles ± ketoprofen did not retard recovery from muscle soreness. TDT 064 improves osteoarthritis-related pain and could be of interest as a treatment for joint pain during and post-exercise.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号