1.
In laboratory medicine, several studies have described the most frequent errors in the different phases of the total testing process, and a large proportion of these errors occur in the pre-analytical phase. Schemes for registration of errors and subsequent feedback to the participants have been conducted for decades concerning the analytical phase by External Quality Assessment (EQA) organizations operating in most countries. The aim of the paper is to present an overview of different types of EQA schemes for the pre-analytical phase, and give examples of some existing schemes. So far, very few EQA organizations have focused on the pre-analytical phase, and most EQA organizations do not offer pre-analytical EQA schemes (EQAS). It is more difficult to perform and standardize pre-analytical EQAS and also, accreditation bodies do not ask the laboratories for results from such schemes. However, some ongoing EQA programs for the pre-analytical phase do exist, and some examples are given in this paper. The methods used can be divided into three different types; collecting information about pre-analytical laboratory procedures, circulating real samples to collect information about interferences that might affect the measurement procedure, or register actual laboratory errors and relate these to quality indicators. These three types have different focus and different challenges regarding implementation, and a combination of the three is probably necessary to be able to detect and monitor the wide range of errors occurring in the pre-analytical phase.  相似文献   

2.
Proficiency of laboratory services is the mainstay in clinical medicine in providing error free diagnostic results. The efficiency of the laboratory needs to be evaluated as per standard international criterion. The quality indicators of the different phases of total testing process are considered the fundamental measurable tool for evaluation of laboratory performance. In order to optimize the laboratory’s proficiency and accreditate it as per international standard in our newly established lab, the study was conducted to evaluate the frequency of errors incurred by laboratory and nonlaboratory professionals during the whole testing process. Retrospective analysis was done for data received from April 2016 to Dec 2016 in our lab. Total number of samples received was 61,674, out of which 43200 samples could be analyzed for quality indicators. Total numbers of tests processed in these samples were 172,800. In the study samples, 26.5% errors were due to pre-analytical factors whereas 9.4% of errors were contributed by analytical phase and 18% by post-analytical phase. Inappropriateness of test requisition was observed to be the major attributing determinant for pre-analytical errors. Instrumentation efficiency in form of frequent breakdown (~7%), greatly affected the proficiency of analytical phase in our lab. 12% of post-analytical errors were ascribed by excessive turn-around-time. However, timeliness of critical value call out and reporting for STAT samples revealed high proficiency up to 97%. High error rates were observed in pre–pre- and pre-analytical phases that also accorded for high error frequency in post analytical phase. This emphasizes urgent need to formulate guidelines for processing all steps of total testing process and initiate strategic measures for reducing risk of errors and increasing patient safety.  相似文献   

3.
4.
Quality indicators (QIs) measure the extent to which set targets are attained and provide a quantitative basis for achieving improvement in care and, in particular, laboratory services. A body of evidence collected in recent years has demonstrated that most errors fall outside the analytical phase, while the pre- and post-analytical steps have been found to be more vulnerable to the risk of error. However, the current lack of attention to extra-laboratory factors and related QIs prevent clinical laboratories from effectively improving total quality and reducing errors. Errors in the pre-analytical phase, which account for 50% to 75% of all laboratory errors, have long been included in the ‘identification and sample problems’ category. However, according to the International Standard for medical laboratory accreditation and a patient-centered view, some additional QIs are needed. In particular, there is a need to measure the appropriateness of all test request and request forms, as well as the quality of sample transportation. The QIs model developed by a working group of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) is a valuable starting point for promoting the harmonization of available QIs, but further efforts should be made to achieve a consensus on the road map for harmonization.  相似文献   

5.
Quality in laboratory has huge impact on diagnosis and patient management as 80–90% of all diagnosis is made on the basis of laboratory tests. Monitoring of quality indicators covering the critical areas of pre-analytical, analytical and post-analytical phases like sample misidentification, sample rejection, random and systemic errors, critical value reporting and TATs have a significant impact on performance of laboratory. This study was conducted in diagnostic laboratories receiving approximately 42,562 samples for clinical chemistry, hematology and serology. The list of quality indicators was developed for the steps of total testing process for which errors are frequent and improvements are possible. The trend was observed for all the QI before and after sensitisation of the staff over the period of 12 months. Incomplete test requisition form received in the lab was the most poor quality indicator observed (7.89%), followed by sample rejection rate (4.91%). Most significant improvement was found in pre- and post-analytical phase after sensitisation of staff but did not have much impact on analytical phase. Use of quality indicators to assess and monitor the quality system of the clinical laboratory services is extremely valuable tool in keeping the total testing process under control in a systematic and transparent way.  相似文献   

6.
Preanalytical steps are the major sources of error in clinical laboratory. The analytical errors can be corrected by quality control procedures but there is a need for stringent quality checks in preanalytical area as these processes are done outside the laboratory. Sigma value depicts the performance of laboratory and its quality measures. Hence in the present study six sigma and Pareto principle was applied to preanalytical quality indicators to evaluate the clinical biochemistry laboratory performance. This observational study was carried out for a period of 1 year from November 2015–2016. A total of 1,44,208 samples and 54,265 test requisition forms were screened for preanalytical errors like missing patient information, sample collection details in forms and hemolysed, lipemic, inappropriate, insufficient samples and total number of errors were calculated and converted into defects per million and sigma scale. Pareto`s chart was drawn using total number of errors and cumulative percentage. In 75% test requisition forms diagnosis was not mentioned and sigma value of 0.9 was obtained and for other errors like sample receiving time, stat and type of sample sigma values were 2.9, 2.6, and 2.8 respectively. For insufficient sample and improper ratio of blood to anticoagulant sigma value was 4.3. Pareto`s chart depicts out of 80% of errors in requisition forms, 20% is contributed by missing information like diagnosis. The development of quality indicators, application of six sigma and Pareto`s principle are quality measures by which not only preanalytical, the total testing process can be improved.  相似文献   

7.
Improper design or use of blood collection devices can adversely affect the accuracy of laboratory test results. Vascular access devices, such as catheters and needles, exert shear forces during blood flow, which creates a predisposition to cell lysis. Components from blood collection tubes, such as stoppers, lubricants, surfactants, and separator gels, can leach into specimens and/or adsorb analytes from a specimen; special tube additives may also alter analyte stability. Because of these interactions with blood specimens, blood collection devices are a potential source of pre-analytical error in laboratory testing. Accurate laboratory testing requires an understanding of the complex interactions between collection devices and blood specimens. Manufacturers, vendors, and clinical laboratorians must consider the pre-analytical challenges in laboratory testing. Although other authors have described the effects of endogenous substances on clinical assay results, the effects/impact of blood collection tube additives and components have not been well systematically described or explained. This review aims to identify and describe blood collection tube additives and their components and the strategies used to minimize their effects on clinical chemistry assays.  相似文献   

8.
This study evaluated the types and frequencies of pre-examination errors recorded in the chemical pathology laboratory at the University Hospital of the West Indies, Jamaica. This was a retrospective analysis of errors recorded over a three year period. Data analysis was done on an average of 519,084 samples collected and tested per year. Samples included blood, urine, stool and other fluids. Pre-examination errors were identified and recorded following visual inspection of the samples and corresponding request forms by laboratory staff, then subsequently by the Senior Medical Technologist. Errors were generally classified as inappropriate sample (58 %), inappropriate form (23.4 %), inappropriate sample volume (9.3 %) and inappropriate sample tube (9.3 %). Over 90 % of recorded pre-examination errors were related to blood samples while urine samples accounted for 6.8 % error. Pre-examination errors were lower at this study location than elsewhere. Measures aimed at reducing instances of these errors are recommended for improved laboratory quality output.  相似文献   

9.
Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease.  相似文献   

10.
IntroductionMoving average (MA) is one possible way to use patient results for analytical quality control in medical laboratories. The aims of this study were to: (1) implement previously optimized MA procedures for 10 clinical chemistry analytes into the laboratory information system (LIS); (2) monitor their performance as a real-time quality control tool, and (3) define an algorithm for MA alarm management in a small-volume laboratory to suit the specific laboratory.Materials and methodsMoving average alarms were monitored and analysed over a period of 6 months on all patient results (total of 73,059) obtained for 10 clinical chemistry parameters. The optimal MA procedures were selected previously using an already described technique called the bias detection simulation method, considering the ability of bias detection the size of total allowable error as the key parameter for optimization.ResultsDuring 6 months, 17 MA alarms were registered, which is 0.023% of the total number of generated MA values. In 65% of cases, their cause was of pre-analytical origin, in 12% of analytical origin, and in 23% the cause was not found. The highest alarm rate was determined on sodium (0.10%), and the lowest on calcium and chloride.ConclusionsThis paper showed that even in a small-volume laboratory, previously optimized MA procedures could be successfully implemented in the LIS and used for continuous quality control. Review of patient results, re-analysis of samples from the stable period, analysis of internal quality control samples and assessment of the analyser malfunctions and maintenance log have been proposed for the algorithm for managing MA alarms.  相似文献   

11.
Errors in laboratory medicine occur in the preanalytical, analytical, and postanalytical phases. The errors are mostly detected in the preanalytical period. However, analytical errors are still an important source of error, despite their frequency is reduced significantly in years thanks to developments in laboratories. In this case, an analytical error was noticed during the verification of a patient’s results. The direct bilirubin of a 66-year-old male patient admitted to the emergency department was higher than the total bilirubin. The patient’s symptoms were fatigue and dyspnoea. Albumin and haemoglobin (Hb) concentrations of the patient were significantly low. After considering the patient’s demographics and laboratory results, the laboratory specialist suspected a paraproteinemia interference. Total protein was performed as a reflective test. The albumin/globulin ratio was reversed. Thereafter, serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE) were performed as another reflective tests, respectively. SPEP and IFE results were in favour of monoclonal gammopathy. The patient was directed to a haematologist, underwent a bone marrow biopsy, and the result was reported as Waldenstrom’s macroglobulinemia with plasma cell differentiation expressing IgM-Kappa. The patient went on a chemotherapy protocol, and his condition has been improved in subsequent months. Detection of analytical errors is of great importance, like in our case, and may be used as a tool to identify patients who have not yet been diagnosed. The laboratory specialist must dominate the entire process of each test in the laboratory, be aware of the limitations of tests, and turn these disadvantages into advantages when necessary.  相似文献   

12.
IntroductionTo interpret test results correctly, understanding of the variations that affect test results is essential. The aim of this study is: 1) to evaluate the clinicians’ knowledge and opinion concerning biological variation (BV), and 2) to investigate if clinicians use BV in the interpretation of test results.Materials and methodsThis study uses a questionnaire comprising open-ended and close-ended questions. Questions were selected from the real-life numerical examples of interpretation of test results, the knowledge about main sources of variations in laboratories and the opinion of clinicians on BV. A total of 399 clinicians were interviewed, and the answers were evaluated using a scoring system ranked from A (clinician has the highest level of knowledge and the ability of using BV data) to D (clinician has no knowledge about variations in laboratory). The results were presented as number (N) and percentage (%).ResultsAltogether, 60.4% of clinicians have knowledge of pre-analytical and analytical variations; but only 3.5% of them have knowledge related to BV. The number of clinicians using BV data or reference change value (RCV) to interpret measurements results was zero, while 79.4% of clinicians accepted that the difference between two measurements results located within the reference interval may be significant.ConclusionsClinicians do not use BV data or tools derived from BV such as RCV to interpret test results. It is recommended that BV should be included in the medical school curriculum, and clinicians should be encouraged to use BV data for safe and valid interpretation of test results.  相似文献   

13.

Introduction:

Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory.

Materials and methods:

This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors.

Results:

A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients.

Conclusions:

The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.  相似文献   

14.
IntroductionFollowing a pandemic, laboratory medicine is vulnerable to laboratory errors due to the stressful and high workloads. We aimed to examine how laboratory errors may arise from factors, e.g., flexible working order, staff displacement, changes in the number of tests, and samples will reflect on the total test process (TTP) during the pandemic period.Materials and methodsIn 12 months, 6 months before and during the pandemic, laboratory errors were assessed via quality indicators (QIs) related to TTP phases. QIs were grouped as pre-, intra- and postanalytical. The results of QIs were expressed in defect percentages and sigma, evaluated with 3 levels of performance quality: 25th, 50th and 75th percentile values.ResultsWhen the pre- and during pandemic periods were compared, the sigma value of the samples not received was significantly lower in pre-pandemic group than during pandemic group (4.7σ vs. 5.4σ, P = 0.003). The sigma values of samples transported inappropriately and haemolysed samples were significantly higher in pre-pandemic period than during pandemic (5.0σ vs. 4.9σ, 4.3σ vs. 4.1σ; P = 0.046 and P = 0.044, respectively). Sigma value of tests with inappropriate IQC performances was lower during pandemic compared to the pre-pandemic period (3.3σ vs. 3.2σ, P = 0.081). Sigma value of the reports delivered outside the specified time was higher during pandemic than pre-pandemic period (3.0σ vs. 3.1σ, P = 0.030).ConclusionIn all TTP phases, some quality indicators improved while others regressed during the pandemic period. It was observed that preanalytical phase was affected more by the pandemic.  相似文献   

15.
During post-analytical phase, critical value notification to responsible caregiver in a timely manner has potential to improve patient safety which requires cooperative efforts between laboratory personnel and caregivers. It is widely accepted by hospital accreditors that ineffective notification can lead to diagnostic errors that potentially harm patients and are preventable. The objective of the study was to assess the variables affecting critical value notification, their role in affecting it’s quality and approaches to improve it. In the present study 1,187 critical values were analysed in the Clinical Chemistry Laboratory catering to tertiary care hospital for neuropsychiatric diseases. During 25 months of study period, we evaluated critical value notification with respect to clinical care area, caregiver to whom it was notified and timeliness of notification. During the study period (25 months), the laboratory obtained 1,279 critical values in clinical chemistry. The analytes most commonly notified were sodium and potassium (20.97 & 20.8 % of total critical results). Analysis of critical value notification versus area of care showed that critical value notification was high in ICU and emergency area followed by inpatients and 64.61 % critical values were notified between 30 and 120 min after receiving the samples. It was found that failure to notify the responsible caregiver in timely manner represent an important patient safety issue and may lead to diagnostic errors. The major area of concern are notification of critical value for outpatient samples, incompleteness of test requisition forms regarding illegible writing, lack of information of treating physician and location of test ordering and difficulty in contacting the responsible caregiver.  相似文献   

16.
IntroductionThe COVID-19 pandemic has posed several challenges to clinical laboratories across the globe. Amidst the outbreak, errors occurring in the preanalytical phase of sample collection, transport and processing, can further lead to undesirable clinical consequences. Thus, this study was designed with the following objectives: (i) to determine and compare the blood specimen rejection rate of a clinical laboratory and (ii) to characterise and compare the types of preanalytical errors between the pre-pandemic and the pandemic phases.Materials and methodsThis retrospective study was carried out in a trauma-care hospital, presently converted to COVID-19 care centre. Data was collected from (i) pre-pandemic phase: 1st October 2019 to 23rd March 2020 and (ii) pandemic phase: 24th March to 31st October 2020. Blood specimen rejection rate was calculated as the proportion of blood collection tubes with preanalytical errors out of the total number received, expressed as percentage.ResultsTotal of 107,716 blood specimens were screened of which 43,396 (40.3%) were received during the pandemic. The blood specimen rejection rate during the pandemic was significantly higher than the pre-pandemic phase (3.0% versus 1.1%; P < 0.001). Clotted samples were the commonest source of preanalytical errors in both phases. There was a significant increase in the improperly labelled samples (P < 0.001) and samples with insufficient volume (P < 0.001), whereas, a significant decline in samples with inadequate sample-anticoagulant ratio and haemolysed samples (P < 0.001).ConclusionIn the ongoing pandemic, preanalytical errors and resultant blood specimen rejection rate in the clinical laboratory have significantly increased due to changed logistics. The study highlights the need for corrective steps at various levels to reduce preanalytical errors in order to optimise patient care and resource utilisation.  相似文献   

17.

Introduction

Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC).

Materials and methods

We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square.

Results

There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients.

Conclusion

We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system.Key words: Preanalytical phase, errors in laboratory medicine, balanced scorecard, patient safety  相似文献   

18.
IntroductionThe detection and prevention of errors in the postanalytical phase can be done through the harmonization and standardization of constituent parts of this phase of laboratory work. The aim was to investigate how well the ongoing management of the postanalytical phase corresponds to the document “Post-analytical laboratory work: national recommendations” in Croatian medical biochemistry laboratories (MBLs).Materials and methodsAll 195 MBLs participating in the national external quality assessment scheme, were invited to undertake a part in a survey. Through 23 questions the participants were asked about management of the reference intervals (RI), delta check, reflex/reflective testing, postanalytical quality indicators and other parts of the postanalytical phase recommended in the national recommendations. The results are presented in numbers and percentages.ResultsOut of 195 MBLs, 119 participated in the survey, giving a response rate of 61%. Not all of the respondents provided answers to all the questions. Delta check has not been used in 59% (70/118) of the laboratories. Only 22/113 (20%) laboratories use reflex and/or reflective testing. In 53% of the laboratories, critical results were reported within 30 minutes of the confirmation of the results. In 34% (40/118) of the laboratories, turnaround time and reporting of critical results are two most often monitored postanalytical quality indicators.ConclusionThe results showed the critical results reporting and monitoring of postanalytical quality indicators are in the line with the recommendations. However, the management of RI verification, the use of delta check and reflex/reflective testing still must be harmonized among Croatian MBLs.  相似文献   

19.
Laboratories have a major impact on patient safety as 80–90 % of all the diagnosis are made on the basis of laboratory tests. Laboratory errors have a reported frequency of 0.012–0.6 % of all test results. Patient safety is a managerial issue which can be enhanced by implementing active system to identify and monitor quality failures. This can be facilitated by reactive method which includes incident reporting followed by root cause analysis. This leads to identification and correction of weaknesses in policies and procedures in the system. Another way is proactive method like Failure Mode and Effect Analysis. In this focus is on entire examination process, anticipating major adverse events and pre-emptively prevent them from occurring. It is used for prospective risk analysis of high-risk processes to reduce the chance of errors in the laboratory and other patient care areas.  相似文献   

20.

Introduction:

There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values.

Materials and methods:

70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values.

Results:

First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed.

Conclusion:

We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.  相似文献   