首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
Numerical analysis of dynamic behavior of RC slabs under blast loading   总被引:2,自引:0,他引:2  
In Order to reduce economic and life losses due to terrorism or accidental explosion threats,reinforced concrete(RC)slabs of buildings need to be designed or retrofitted to resist blast loading.In this paper the dynamic behavior Of RC slabs under blast loading and its influencing factors are studied.The numerical model of an RC slab subjected to blast loading is established using the explicit dynamic analysis software.Both the strain rate effect and the damage accumulation are taken into account in the material model.The dynamic responses of the RC slab subiected to blast loading are analyzed,and the influence of concrete strength,thickness and reinforcement ratio on the behavior of the RC slab under blast loading iS numerically investigated.Based on the numerical results.some principles for blast-resistant design and retrofitting are proposed to improve the behavior of the RC slab subjected to blast loading.  相似文献   

2.
This paper discusses the collapse mode of thin reinforced concrete (RC) plates subjected to blast load.To extend the well known plastic-mode method to analyze,not only perfectplastic plates,but also RC plates,it is needed to investigate the effect of material cracking on the collapse mode because the plate might have been cracked on both upper and lower surface before the plastic-mode fully develops,creating an unexpected type of collapse mode shape.A new failure mode is proposed and verified by numerical analysis in this paper.The new mode is a result of the material cracking and has an un-negligible effect on the reaction mechanism of the RC plate to the blast load.  相似文献   

3.
Current guidelines recommend using single-degree-of-freedom(SDOF) method for dynamic analysis of reinforced concretec (RC) structures against blast loads, which is not suitable for retrofitted members. Thus, a finite difference procedure developed in another study was used to accurately and efficiently analyze the dynamic response of fibre reinforced polymer (FRP) plated members under blast loads. It can accommodate changes in the mechanical properties of a member's cross section along its length and through its depth in each time step, making it possible to directly incorporate both strain rate effects (which will vary along the length and depth of a member) and non-uniform member loading to solve the partial differential equation of motion. The accuracy of the proposed method was validated in part using data from field blast testing. The finite difference procedure is implemented easily and enables accurate predictions of FRP-plated-member response.  相似文献   

4.
In this study, the effect of steel fibers coated with chemically reactive enamel (CRE) on the system response of concrete structures with reinforcing bars has been investigated for the first time. In particular, the ultimate strength, ductility, and failure mechanism of 24 reinforced concrete slabs were experimentally characterized under static and blast loads. CRE coating applied on steel bars reduced the crater area of slabs under blast loads by up to 20%; it slightly increased the strength of slabs and significantly reduced the strength degradation of slabs when increasingly deflected under static loads, making the slabs more ductile. CRE coating applied on steel fibers increased the strength of slabs by up to 16% under static loads. The influence of CRE coating applied on both steel fibers and bars may be taken into account by introducing a coating factor in the range of 0.57<β<1.0 in the American Concrete Institute (ACI) development length equation.  相似文献   

5.
Abstract: An innovative occupant friendly retrofitting technique has been developed for reinforced concrete (RC) building structures with hollow brick infill wails used as partition walls which constitute the major portion of the existing building stock in Turkey. The idea is to convert the existing hollow brick infill wall into a load carrying system acting as a cast-in-place RC wall by reinforcing it with relatively thin concrete plates bonded to the mortar coated infill wall by use of tile adhesive and fixed by qb6 (6 mm diameter) bolts. Test parameters were the shape and thickness of the plates, presence of reinforcement in plates, number and arrangement of O6 bolts. It was observed that lateral strength, stiffness, energy dissipation capacity, and ductility of the strengthened infill walls were improved and behaviour was enhanced by the proposed technique. Plates with two different basic shapes were used to strengthen the test specimens.  相似文献   

6.
Spallation mechanism of RC slabs under contact detonation   总被引:2,自引:0,他引:2  
The spallation of the concrete slabs or walls resulting from contact detonation constitutes risk to the personnel and equipment inside the structures because of the high speed concrete fragments even though the overall structures or structural members are not destroyed completely.Correctly predicting the damage caused by any potential contact detonation can lead to better for-tification design to withstand the blast loadings.It is therefore of great significance to study the mechanism involved in the spallation of concrete slabs and walls.Existing studies on this topic of-ten employ simplified material models and 1D wave analysis,which cannot reproduce the realistic response in the spallation process.Numerical simulations are therefore carried out under different contact blast loadings in the free air using LS-DYNA.Sophisticated concrete and reinforcing bar material models are adopted,taking into account the strain rate effect on both tension and com-pression.The erosion technique is used to model the fracture and failure of materials under tensile stress.Full processes of the deformation and dynamic damage of reinforced concrete (RC) slabs and plain concrete slabs are thus observed realistically.It is noted that with the increase of quantity of explosive,the dimensions of damage crater increase and the slabs experience four different damage patterns,namely explosive crater,spalling,perforation,and punching.Comparison be-tween the simulation results of plain concrete slabs and those of RC slabs show that reinforcing bars can enhance the integrity and shearing resistance of the slabs to a certain extent,and mean-while attenuate the ejection velocity and decrease the size of the concrete fragments.Therefore,optimizing reinforcement arrangement can improve the anti-spallation capability of the slabs and walls to a certain extent.  相似文献   

7.
In order to evaluate the capacity of reinforced concrete (RC) structures subjected to blast loadings,the damaged plasticity model for concrete was used in the analysis of the dynamic responses of blast-loaded RC structures,and all three failure modes were numerically simulated by the finite element software ABAQUS.Simulation results agree with the experimental observations.It is demonstrated that the damaged plasticity model for concrete in the finite element software ABAQUS can predict dynamic responses and typical flexure,flexure-shear and direct shear failure modes of the blast-loaded RC structures.  相似文献   

8.
Progressive collapse of building structures under blast and impact loads has attracted great attention all over the world. Progressive collapse analysis is essential for an economic and safe design of building structures against progressive collapse to blast and impact loads. Because of the catastrophic nature of progressive collapse and the potentially high cost of constructing or retrofitting buildings to resist it, it is imperative that the progressive collapse analysis methods be reliable. For engineers; their methodology to carry out progressive collapse evaluation need not only be accurate and concise, but also be easily used and works fast. Thus, many researchers have been spending lots of effort in developing reliable, efficient and straightforward progressive collapse analysis methods recently. In the present paper, current progressive collapse analysis methods available in the literature are reviewed. Their suitability, applicability and reliability are discussed. Our recent proposed new method for progressive collapse analysis of reinforced concrete frames under blast loads is also introduced.  相似文献   

9.
This paper discusses the collapse mode of thin reinforced concrete (RC) plates sub-jected to blast load. To extend the well known plastic-mode method to analyze, not only perfect-plastic plates , but also RC plates, it is needed to investigate the effect of material cracking on the collapse mode because the plate might have been cracked on both upper and lower surface before the plastic-mode fully develops, creating an unexpected type of collapse mode shape. A new fail-ure mode is proposed and verified by numerical analysis in this paper. The new mode is a result of the material cracking and has an un-negligible effect on the reaction mechanism of the RC plate to the blast load.  相似文献   

10.
The dynamic characteristics and failure modes of steel reinforced concrete (SRC) columns subjected to blast loading are complicated because of the transient stress wave in the SRC columns and the interaction between steel and concrete. This paper presents a numerical simulation of the response of SRC columns subjected to blast loading using hydrocode LS-DYNA. In the numerical model, a sophisticate concrete material model (the Concrete Damage Model) is employed with consideration of the strain rate effect and the damage accumulation. An erosion technique is adopted to model the spalling process of concrete. The possible failure modes of SRC columns are evaluated. It is observed that the failure of SRC columns subjected to blast load can generally be classified into three modes, namely, a direct failure in concrete body due to the stress wave, a transverse shear failure near the support sections due to the high shear force, and a flexural failure pertaining to large local and global deformation of the reinforcing steel.  相似文献   

11.
Time-to-cracking of the concrete cover induced by the steel corrosion is one of the critical problems faced by engineers, operators and asset managers in making strategies for the maintenance and repairs of reinforced concrete (RC)structures affected by corrosion. In this paper, a theoretical model for predicting the time-to-cracking is derived by assuming the bond between the steel bar and the concrete as a linear combination of perfectly smooth and bonded. The model takes into account the characteristics of existing exiguous flaws and initial cracks in the concrete before the load acting on RC structures. The validity of the proposed model is preliminarily verified by comparing the obtained results with the available experimental results. A remarkable advantage of the proposed method is its application to the prediction of the service life of RC structures, made of the deformed steel bars as well as the round bars. By determining an experimental constant α, which is related to the interface bond state between the steel bar and the concrete, the service life of RC structures can be predicted using the proposed scheme. Analysis of major factors affecting the time-to-cracking demonstrates that the length of the initial crack affects the service life of RC structures significantly. Moreover, the larger cover thickness and the smaller diameter of the steel bar within a certain range are beneficial to prolonging the time-to-cracking.  相似文献   

12.
The blast resistance of structures used in buildings needs to be investigated due to the increased threat of a terrorist attack. The damage done by Composition B or Powergel to steel fibre reinforced reactive powder concrete (SFRPC) panels and ordinary reinforced concrete (RC) panels of equivalent static flexural strength is compared. A 0.5 kg charge was detonated at a distance of 0.1 m from the 1.3 m×1.0 m×0. 1 m (thick) panels, which were simply supported and spaning 1.3m. Dynamic displacement measurements, high-speed video recording and visual examination of the panels for spall and breach were undertaken. The SFRPC panels withstood the bare charge blast better than the reinforced ordinary concrete panels. Neither type of panel was breached using a 0.5 kg charge. The RC panel exhibited more spalling when Composition B was used. Under successive Composition B loading conditions, the RC panel was breached. In comparison the SFRPC panel was not breached. Exposure to fragmenting charge loading conditions confirmed these performance differences between the SFRPC panel and the reinforced ordinary concrete panel.  相似文献   

13.
Terrorist attacks using improvised explosive devices (lED) can result in unreinforced masonry (URM) wall collapse.Protecting URM wall from lED attack is very complicated.An effective solution to mitigate blast effects on URM wall is to retrofit URM walls with metallic foam sheets to absorb blast energy.However,mitigation of blast effects on metallic foam protected URM walls is currently in their infancy in the world.In this palaer,numerical models are used to simulate the performance of aluminum foam protected URM walls subjected to blast loads.A distinctive model,in which mortar and brick units of masonry are discritized individually,is used to model the performance of masonry and the contact between the masonry and steel face-sheet of aluminum foam is modelled using the interface element model.The aluminum foam is modelled by a nonlinear elastoplastic material model.The material models for masonry,aluminum foam and interface are then coded into a finite element program LS-DYNA3D to perform the numerical calculations of response and damage of aluminum foam protected URM walls under airblast loads.Discussion is made on the effectiveness of the aluminum foam protected system for URM wall against blast loads.  相似文献   

14.
Terrorist attacks using improvised explosive devices (IED) can result in unreinforced ma-sonry (URM) wall collapse. Protecting URM wall from IED attack is very complicated. An effective solution to mitigate blast effects on URM wall is to retrofit URM walls with metallic foam sheets to absorb blast energy. However, mitigation of blast effects on metallic foam protected URM walls is currently in their infancy in the world. In this paper, numerical models are used to simulate the per-formance of aluminum foam protected URM walls subjected to blast loads. A distinctive model, in which mortar and brick units of masonry are discritized individually, is used to model the perform-ance of masonry and the contact between the masonry and steel face-sheet of aluminum foam is modelled using the interface element model. The aluminum foam is modelled by a nonlinear elas-toplastic material model. The material models for masonry, aluminum foam and interface are then coded into a finite element program LS-DYNA3D to perform the numerical calculations of response and damage of aluminum foam protected URM walls under airblast loads. Discussion is made on the effectiveness of the aluminum foam protected system for URM wall against blast loads.  相似文献   

15.
The progressive collapse of steel frame structures under the blast load was investigated using LS-DYNA. The multi-material Eulerian and Lagrangian coupling algorithm was adopted. A flu-id-structure coupling finite element model was established which consists of Lagrange element for simulating steel frame structures and concrete ground, multiple ALE element for simulating air and TNT explosive material. Numerical simulations of the blast pressure wave propagation, struc-tural dynamic responses and deformation, and progressive collapse of a five-story steel frame structure in the event of an explosion near above ground were performed. The numerical analysis showed that the Lagrangian and Eulerian coupling algorithm gave good simulations of the shock wave propagation in the mediums and blast load effects on the structure. The columns subjected to blast load may collapse by shear yielding rather than by flexural deformation. The columns and joints of steel beam to column in the front steel frame structure generated enormous plastic defor-mation subjected to intensive blast waves, and columns lost carrying capacity, subsequently lead-ing to the collapse of the whole structure. The approach coupling influence between struc-tural deformation and fluid load well simulated the progressive collapse process of structures, and provided an effective tool for analyzing the collapse mechanism of the steel frame structure under blast load.  相似文献   

16.
The progressive collapse of steel frame structures under the blast load was investigated using LS-DYNA.The multi-material Eulerian and Lagrangian coupling algorithm was adopted.A fluid-structure coupling finite element model was established which consists of Lagrange element for simulating steel frame structures and concrete ground,multiple ALE element for simulating air and TNT explosive material.Numerical simulations of the blast pressure wave propagation,structural dynamic responses and deformation,and progressive collapse of a five-story steel frame structure in the event of an explosion near above ground were performed.The numerical analysis showed that the Lagrangian and Eulerian coupling algorithm gave good simulations of the shock wave propagation in the mediums and blast load effects on the structure.The columns subjected to blast load may collapse by shear yielding rather than by flexural deformation.The columns and joints of steel beam to column in the front steel frame structure generated enormous plastic deformation subjected to intensive blast waves,and columns lost carrying capacity,subsequently leading to the collapse of the whole structure.The approach coupling influence between structural deformation and fluid load well simulated the progressive collapse process of structures,and provided an effective tool for analyzing the collapse mechanism of the steel frame structure under blast load.  相似文献   

17.
高层钢结构组合楼盖的设计研究   总被引:1,自引:0,他引:1  
基于对高层钢结构设计中的三种常见组合楼盖的优缺点分析,论述了适当的连接形式可以保证压型钢板与混凝土可靠连接的机理,组合楼盖的设计验算主要包括施工阶段验算与使用阶段的验算。构造设计包括栓钉的设置、混凝土板的配筋、压型钢板尺寸及表面处理。对组合楼盖的设计研究有利于高层钢结构建筑的长足发展。  相似文献   

18.
To investigate the seismic behavior of connections composed of steel reinforced ultra high strength concrete (SRUHSC) column and reinforced concrete (RC) beam, six interior strong-column-weak-beam connection specimens were tested subjected to reversal cyclic load. Effects of applied axial load ratio and volumetric stirrup ratio on ductility, energy dissipation capacity, strength degradation and rigidity degradation were discussed. It was found that all connection specimens failed in bending in a ductile manner with a beam plastic hinge. The ductility and energy dissipation capacity increased with the decrease of applied axial load ratio or increase of volumetric stirrup ratio. The displacement ductility coefficient and equivalent damping coefficient lay between those of steel reinforced ordinary concrete connection and those of reinforced concrete connection. The applied axial load ratio and volumetric stirrup ratio had less influence on the strength degradation and more influence on the stiffness degradation. The stiffness degraded sharply with the decrease of volumetric stirrup ratio or increase of applied axial load ratio. The experimental results indicate that SRUHSC column and RC beam connection exhibited better seismic performance and can provide reference for engineering application.  相似文献   

19.
In this study, two full-size concrete walls were tested and analyzed to demonstrate the effectiveness of a chemically reactive enamel (CRE) coating in improving their mechanical behavior under blast loading: one with CRE-coated rebar and the other with uncoated rebar. Each wall was subjected in sequence to four explosive loads with equivalent 2, 4, 6-trinitrotoluene (TNT) charge weights of 1.82, 4.54, 13.6, and 20.4 kg. A finite element model of each wall under a close-in blast load was developed and validated with pressure and strain measurements, and used to predict rebar stresses and concrete surface strain distributions of the wall. The test results and visual inspections consistently indicated that, compared with the barrier wall with uncoated reinforcement, the wall with CRE-coated rebar has fewer concrete cracks on the front and back faces, more effective stress transfers from concrete to steel rebar, and stronger connections with its concrete base. The concrete surface strain distributions predicted by the model under various loading conditions are in good agreement with the crack patterns observed during the tests.  相似文献   

20.
The nonlinear analysis of reinforced concrete rectangular slabs undermonotonic transverse loads is performed by finite element method.The layered rectangu-lar element with 4 nodes and 20 degrees of freedom is developed,in whichbending-stretching coupling effect is taken into account.An orthotropic equivalentuniaxial stress-strain constitutive model of concrete is used.A program is worked out andused to calculate two reinforced concrete slabs.The results of calculation are in goodconformity with the corresponding test results.In addition,the influence of tension stif-fening effect of cracked concrete on the results of calculation is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号