首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
It has previously been shown that females incur less muscle damage than males after strenuous exercise, but limited data are available for humans. To determine possible differences between the sexes in humans, the response to high-force eccentric exercise was examined in a large sample of women (n = 83) and men (n = 82). The participants performed a bout of eccentric exercise of the elbow flexors consisting of 70 maximal repetitions. Isometric strength, resting elbow angle and muscle soreness were measured before, immediately after (except soreness) and then daily for 7 days after exercise. There was a significant loss in strength among both groups (69% for women and 63% for men) (P < 0.01) immediately after exercise; at 168 h post-exercise, women still had a 27% strength loss and men had a 24% strength loss. No significant difference in strength loss or recovery rate was found between men and women. Soreness reached peak values 32-48 h post-exercise (P < 0.01), with no significant difference between men and women. Range of motion decreased significantly until 3 days after exercise (14.6 degrees or 0.255 rad loss for women; 12.2 degrees or 0.213 rad loss for men) (P < 0.01); at 168 h post-exercise, the women and men still showed a loss of 4.8 degrees (0.084 rad) and 4.0 degrees (0.07 rad), respectively. There was a significant interaction of sex x time (P < 0.01); a post-hoc test indicated that the women experienced a greater loss in range of motion at 72 h than men and this difference was maintained to 168 h post-exercise (P < 0.01). Thus, our results do not support the contention that women have a lower response to eccentric exercise than men.  相似文献   

2.
Abstract

In this study, we wished to determine whether a warm-up exercise consisting of 100 submaximal concentric contractions would attenuate delayed-onset muscle soreness and decreases in muscle strength associated with eccentric exercise-induced muscle damage. Ten male students performed two bouts of an elbow flexor exercise consisting of 12 maximal eccentric contractions with a warm-up exercise for one arm (warm-up) and without warm-up for the other arm (control) in a randomized, counterbalanced order separated by 4 weeks. Muscle temperature of the biceps brachii prior to the exercise was compared between the arms, and muscle activity of the biceps brachii during the exercise was assessed by surface integral electromyogram (iEMG). Changes in visual analogue scale for muscle soreness and maximal voluntary isometric contraction strength (MVC) of the elbow flexors were assessed before, immediately after, and every 24 h for 5 days following exercise, and compared between the warm-up and control conditions by a two-way repeated-measures analysis of variance. The pre-exercise biceps brachii muscle temperature was significantly (P<0.01) higher for the warm-up (35.8±0.2°C) than the control condition (34.4±0.2°C), but no significant differences in iEMG and torque produced during exercise were evident between conditions. Changes in muscle soreness and MVC were not significantly different between conditions, although these variables showed significant (P<0.05) changes over time. It was concluded that the warm-up exercise was not effective in mitigating delayed-onset muscle soreness and loss of muscle strength following maximal eccentric exercise.  相似文献   

3.
Post-exercise cryotherapy treatments are typically short duration interventions. This study examined the efficacy of prolonged cooling using phase change material (PCM) on strength loss and pain after eccentric exercise. Eight adults performed 120 bilateral eccentric quadriceps contractions (90% MVC). Immediately afterwards, frozen PCM packs (15°C) were placed over the quadriceps, with room temperature PCM packs on the contralateral quadriceps. Skin temperature was recorded continually (6 h PCM application). Isometric quadriceps strength and soreness were assessed before, 24, 48, 72 and 96 h post-exercise. The protocol was repeated 5 months later, with room temperature PCM applied to both legs. There were three treatments: legs treated with 15°C PCM packs (direct cooling), legs treated with room temperature PCM packs contralateral to the 15°C PCM packs (systemic cooling), and legs tested 5 months later both treated with room temperature PCM packs (control). Skin temperature was 9°C–10°C lower with direct cooling versus systemic cooling and control (P < 0.01). Strength loss and soreness were less (P < 0.05) with direct cooling versus systemic cooling and control (strength 101%, 94%, 93%, respectively; pain 1.0, 2.3, 2.7, respectively). Six hours of PCM cooling was well tolerated and reduced strength loss and pain after damaging exercise.  相似文献   

4.
The aim of this study was to examine neuromuscular variables contributing to differences in force loss after participants were exposed to the same relative bout of eccentric exercise. Thirty-six males performed 50 maximal eccentric contractions of the elbow flexors and were stratified into high responders (n?=?10) and low responders (n?=?10) based on force loss 36 h after exercise. Maximal voluntary isometric contractions (MVCs) and electromyography (EMG) were measured at baseline and 36 h after exercise. During eccentric exercise, mean peak torque, mean end-range torque from the final 25% of each trial and total angular impulse were computed over 25 contractions in each of two bouts. The slope of the change in these values for each 25 eccentric contractions was calculated for each participant using linear regression. At baseline, MVC was not different between groups (low responders: 97.0?±?9.6 N?·?m; high responders: 82.7?±?6.4 N?·?m; P?=?0.08). High responders demonstrated a 68% (range 62-78%) reduction in MVC and low responders a 39% (29-48%) reduction after exercise. Peak torque, end-range torque and total angular impulse were 13%, 40% and 33% higher, respectively, in the low than in the high responders (peak torque: P?=?0.0002; end-range torque: P?<?0.0001; total angular impulse: P?<?0.001). The rate of decline in peak torque slope was greater in high than in low responders (P?=?0.044). In conclusion, lower peak torque, end-range torque and total angular impulse during eccentric contractions and a greater peak torque slope may identify high responders to eccentric exercise.  相似文献   

5.
Delayed-onset muscle soreness refers to the skeletal muscle pain that is experienced following eccentric exercise. The aim of the present study was to examine the physiological effects of physical activity with or without ibuprofen on delayed onset muscle soreness. Forty-four non-athletic male volunteers (age 24.3?±?2.4 years) were randomly assigned to one of four groups: physical activity (n = 11), ibuprofen (n = 11), physical activity and ibuprofen (combination, n = 11), or control (n = 11). The physical activity programme comprised 5?min of walking and jogging, 10?min of static stretching of the hands and shoulder girdle, and 5?min of concentric movements with sub-maximal contractions. The total amount of ibuprofen consumed by a single individual was 2800?mg; this was taken from 1?h before the eccentric actions up to 48?h after it. Delayed onset muscle soreness was induced by performing 70 eccentric contractions of the biceps muscle of the non-dominant side on a modified arm curl machine. Perceived muscle soreness, maximal eccentric contraction, creatine kinase enzyme activity and elbow range of motion were assessed 1?h before and 1, 24 and 48?h after the eccentric actions. The results indicated that, after the eccentric actions, soreness increased (P?<?0.001) across time in all groups, with the highest values being recorded at 24?h. At 24 and 48?h, greater soreness (P <?0.001) was observed in the control group than in the physical activity and combination groups. After the eccentric actions, creatine kinase increased and was elevated (P?<?0.001) compared with baseline in all groups, with values returning to baseline in the physical activity and combination groups by 48?h. However, creatine kinase in the control and ibuprofen groups was still significantly higher than at baseline after 48?h. Creatine kinase was higher (P?<?0.001) in the control group than in physical activity and combination groups at 24 and 48?h. There was also a reduction (P?<?0.001) in elbow range of motion across time. This reduction in elbow range of motion was greater (P?<?0.001) in the control and ibuprofen groups than in the physical activity and combination groups at 1, 24 and 48?h. The reduction in maximum eccentric contraction was greater (P?<?0.001) in the control and ibuprofen groups than in the physical activity group at 24 and 48?h and the combination group at 48?h. In conclusion, the results add to our understanding of the effects of physical activity and the combination of physical activity and ibuprofen in reducing the severity of muscle soreness induced by eccentric exercise. Physical activity conducted before eccentric exercise alleviates muscle soreness. Our results indicate that physical activity with or without ibuprofen helps to prevent delayed-onset muscle soreness.  相似文献   

6.
Abstract

The purpose of this study was to investigate the eccentric torque–velocity and power–velocity relationships of the elbow flexors. Forty recreationally trained individuals (20 men, 20 women) performed maximal eccentric actions at each of five different velocities (1.04 rad · s?1, 2.09 rad · s?1, 3.14 rad · s?1, 4.18 rad · s?1, and 5.23 rad · s?1, in random order) and maximal isometric actions on a Biodex isokinetic dynamometer. A 2×6 (sex×velocity) mixed-factor repeated-measures analysis of variance (ANOVA) was used to assess peak elbow flexor torque during the eccentric and isometric actions. There was no interaction, but there were significant main effects for sex and velocity. Pairwise comparisons demonstrated that values for men were significantly (P<0.05) higher than those for women at all speeds. Furthermore, torques for both sexes were significantly less at 3.14 rad · s?1 (men: 103.94±28.28 N · m; women: 49.24±11.69 N · m) than at 4.18 rad · s?1 (men: 106.39±30.23 N · m; women: 52.77±11.31 N · m) and 5.23 rad · s?1 (men: 108.75±28.59 N · m; women: 53.3±11.67 N · m), while isometric torque was significantly less than at all other speeds (men: 98.66±28.0 N · m; women: 45.25±11.15 N · m). A 2×5 (sex×velocity) mixed-factor repeated-measures ANOVA was used to assess peak eccentric elbow flexor power. There were significant main effects for sex and velocity. Pairwise comparisons demonstrated that values for men were significantly higher than those for women at all speeds. Pairwise comparisons for velocity indicated that peak eccentric power increased across all speeds from 1.04 rad · s?1 (men: 110.44±32.56 W; women 54.36±13.05 W) to 5.23 rad · s?1 (men: 569.46±149.73 W; women: 279.10±61.10 W). These results demonstrate that an increase in velocity had little or no effect on eccentric elbow flexor torque, while eccentric elbow flexor power increased significantly with increases in velocity.  相似文献   

7.
Abstract

The aim of this study was to examine the effect of concentric warm-up exercise on eccentrically induced changes in muscle strength, range of motion, and soreness of the elbow flexors. Ten resistance-exercise naïve participants performed intermittent incremental eccentric actions (42 in total) of the elbow flexor muscles of each arm to induce muscle damage. The arms of each participant were randomly assigned either to a pre-eccentric exercise warm-up involving intermittent concentric exercise (warm-up) or no prior exercise (control). Strength, range of motion, and ratings of soreness were recorded before and 1, 2, 3, 4, and 7 days after exercise. Strength, range of motion, and soreness during muscular movements changed over time (P at most 0.01; Cohen's d at least 0.51, medium). There was an interaction (P < 0.001) for strength, showing a smaller reduction after exercise for warm-up than control (P < 0.001, d = 2.44, large effect). The decreased range of motion was less for warm-up than control for the arm while extended (P < 0.001), flexed (P = 0.002), and relaxed (P = 0.004). Muscle soreness was reduced for the warm-up group, while the muscle was flexed, extended, and relaxed compared with control (P < 0.001). The results demonstrate that a concentric warm-up exercise attenuates the reduction in loss of strength, range of motion, and muscle soreness after eccentric-exercise-induced muscle damage and might allow higher intensities of training to be performed.  相似文献   

8.
A single bout of eccentric exercise induces a protective adaptation against damage from a repeated bout. The aim of this study was to determine whether this repeated bout effect is due to a change in the length–tension relationship. Twelve individuals performed an initial bout of six sets of 10 eccentric quadriceps contractions and then performed a repeated bout 2 weeks later. Eccentric contractions were performed on an isokinetic dynamometer at 1.04 rad?·?s?1 with a target intensity of 90% of isometric strength at 70° of knee flexion. Isometric strength and pain were recorded before and after both eccentric bouts and on each of the next 3 days. Isometric strength was tested at 30°, 50°, 70°, 90° and 110° of knee flexion. On the days following the initial bout, there was a significant loss of isometric strength at all knee flexion angles except 110° (bout×angle: P?<0.01). On day 2, strength averaged 86% of baseline for 30–90° and 102% of baseline for 110°. Strength loss and pain after the initial bout was contrasted by minimal changes after the repeated bout (pain: P?<0.001; strength: P?<0.01). The repeated bout effect was associated with a rightward shift in the length–tension curve; before the repeated bout, isometric strength was 6.8% lower at 30° and 13.6% higher at 110° compared with values before the initial bout (bout×angle: P?<0.05). Assuming that torque production at 110° occurs on the descending limb of the length–tension curve, the increase in torque at 110° may be explained by a longitudinal addition of sarcomeres. The addition of sarcomeres would limit sarcomere strain for subsequent eccentric contractions and may explain the repeated bout effect observed here.  相似文献   

9.
Abstract

This study was undertaken to examine the acute effect of interferential current on mechanical pain threshold and isometric peak torque after delayed onset muscle soreness induction in human hamstrings. Forty-one physically active healthy male volunteers aged 18?33 years were randomly assigned to one of two experimental groups: interferential current group (n = 21) or placebo group (n = 20). Both groups performed a bout of 100 isokinetic eccentric maximal voluntary contractions (10 sets of 10 repetitions) at an angular velocity of 1.05 rad · s?1 (60° · s?1) to induce muscle soreness. On the next day, volunteers received either an interferential current or a placebo application. Treatment was applied for 30 minutes (4 kHz frequency; 125 μs pulse duration; 80?150 Hz bursts). Mechanical pain threshold and isometric peak torque were measured at four different time intervals: prior to induction of muscle soreness, immediately following muscle soreness induction, on the next day after muscle soreness induction, and immediately after the interferential current and placebo application. Both groups showed a reduction in isometric torque (P < 0.001) and pain threshold (P < 0.001) after the eccentric exercise. After treatment, only the interferential current group showed a significant increase in pain threshold (P = 0.002) with no changes in isometric torque. The results indicate that interferential current was effective in increasing hamstrings mechanical pain threshold after eccentric exercise, with no effect on isometric peak torque after treatment.  相似文献   

10.
Runners often experience delayed onset muscle soreness (DOMS), especially of the knee extensors, following prolonged running. Sagittal knee joint biomechanics are altered in the presence of knee extensor DOMS but it is unclear how muscle soreness affects lower limb biomechanics in other planes of motion. The purpose of this study was to assess the effects of knee extensor DOMS on three-dimensional (3D) lower limb biomechanics during running. Thirty-three healthy men (25.8?±?6.8 years; 84.1?±?9.2?kg; 1.77?±?0.07?m) completed an isolated eccentric knee extensor damaging protocol to elicit DOMS. Biomechanics of over-ground running at a set speed of 3.35?m?s?1±5% were measured before eccentric exercise (baseline) and, 24?h and 48?h following exercise in the presence of knee extensor DOMS. Knee flexion ROM was reduced at 48?h (P?=?0.01; d?=?0.26), and peak knee extensor moment was reduced at 24?h (P?=?0.001; d?=?0.49) and 48?h (P?<?0.001; d?=?0.68) compared to baseline. Frontal and transverse plane biomechanics were unaffected by the presence of DOMS (P?>?0.05). Peak positive ankle and knee joint powers and, peak negative knee joint power were all reduced from baseline to 24?h and 48?h (P?<?0.05). These findings suggest that knee extensor DOMS greatly influences sagittal knee joint angular kinetics and, reduces sagittal power production at the ankle joint. However, knee extensor DOMS does not affect frontal and transverse plane lower limb joint biomechanics during running.  相似文献   

11.
Cryotherapy is an effective treatment for acute sports injury to soft tissue, although the effect of cryotherapy on exercise-induced muscle damage is unclear. The aim of this study was to assess the effects of cold water immersion on the symptoms of exercise-induced muscle damage following strenuous eccentric exercise. After performing a bout of damage-inducing eccentric exercise (eight sets of five maximal reciprocal contractions at 0.58 rad x s(-1)) of the elbow flexors on an isokinetic dynamometer, 15 females aged 22.0+/-2.0 years (mean +/- s) were allocated to a control group (no treatment, n = 7) or a cryotherapy group (n = 8). Subjects in the cryotherapy group immersed their exercised arm in cold water (15 degrees C) for 15 min immediately after eccentric exercise and then every 12 h for 15 min for a total of seven sessions. Muscle tenderness, plasma creatine kinase activity, relaxed elbow angle, isometric strength and swelling (upper arm circumference) were measured immediately before and for 3 days after eccentric exercise. Analysis of variance revealed significant (P < 0.05) main effects for time for all variables, with increases in muscle tenderness, creatine kinase activity and upper arm circumference, and decreases in isometric strength and relaxed elbow angle. There were significant interactions (P<0.05) of group x time for relaxed elbow angle and creatine kinase activity. Relaxed elbow angle was greater and creatine kinase activity lower for the cryotherapy group than the controls on days 2 and 3 following the eccentric exercise. We conclude that although cold water immersion may reduce muscle stiffness and the amount of post-exercise damage after strenuous eccentric activity, there appears to be no effect on the perception of tenderness and strength loss, which is characteristic after this form of activity.  相似文献   

12.
We tested the hypothesis that backward downhill walking (eccentric component) impairs both voluntary activation and muscle contractile properties in the plantar flexors and delays recovery as compared to a gradient and distance-matched uphill walk. Fourteen males performed two 30-min walking exercises (velocity: 1?m/?s; grade: 25%; load: 12% of body weight), one downhill (DW) and one uphill (UP), in a counterbalanced order, separated by 6?weeks. Neuromuscular test sessions were performed before, after, 24-, 48- and 72-h post-exercise, including motor nerve stimulations during brief (5?s) and sustained (1?min) maximal isometric voluntary contractions of the plantar flexors. DW (?18.1?±?11.1%, P?P?=.15), decreased torque production during brief contractions for at least three days post-exercise (P?P?P?=?.024) and DW (?25.6?±?10.3%, P?P?=?.001) was lower in DW than UP. Peak twitch torque and maximum rates of torque development and relaxation were equally reduced after UP and DW (P?P?P?>?.05). Using a direct comparison, the capacity to drive the plantar flexors during sustained contractions remains sub-optimal during the three-day recovery period in response to non-exhaustive, downhill backward walking in reference to an uphill exercise matched for distance covered.  相似文献   

13.
The aim of this study was to examine the effect of concentric warm-up exercise on eccentrically induced changes in muscle strength, range of motion, and soreness of the elbow flexors. Ten resistance-exercise naive participants performed intermittent incremental eccentric actions (42 in total) of the elbow flexor muscles of each arm to induce muscle damage. The arms of each participant were randomly assigned either to a pre-eccentric exercise warm-up involving intermittent concentric exercise (warm-up) or no prior exercise (control). Strength, range of motion, and ratings of soreness were recorded before and 1, 2, 3, 4, and 7 days after exercise. Strength, range of motion, and soreness during muscular movements changed over time (P at most 0.01; Cohen's d at least 0.51, medium). There was an interaction (P?相似文献   

14.
Surface electromyographic (EMG) signals were recorded from the hamstring muscles during six sets of submaximal isokinetic (2.6 rad x s(-1)) eccentric (11 men, 9 women) or concentric (6 men, 4 women) contractions. The EMG per unit torque increased during eccentric (P < 0.01) but not during concentric exercise. Similarly, the median frequency increased during eccentric (P < 0.01) but not during concentric exercise. The EMG per unit torque was lower for submaximal eccentric than maximum isometric contractions (P < 0.001), and lower for submaximal concentric than maximum isometric contractions (P < 0.01). The EMG per unit torque was lower for eccentric than concentric contractions (P < 0.05). The median frequency was higher for submaximal eccentric than maximum isometric contractions (P < 0.001); it was similar, however, between submaximal concentric and maximum isometric contractions (P = 0.07). Eccentric exercise resulted in significant isometric strength loss (P < 0.01), pain (P < 0.01) and muscle tenderness (P < 0.05). The greatest strength loss was seen 1 day after eccentric exercise, while the most severe pain and muscle tenderness occurred 2 days after eccentric exercise. A lower EMG per unit torque is consistent with the selective recruitment of a small number of motor units during eccentric exercise. A higher median frequency during eccentric contractions may be explained by selective recruitment of fast-twitch motor units. The present results are consistent with the theory that muscle damage results from excessive stress on a small number of active fibres during eccentric contractions.  相似文献   

15.
Fatigue represents a reduction in the capability of muscle to generate force. The aim of the present study was to establish the effects of exercise that simulates the work rate of competitive soccer players on the strength of the knee extensors and knee flexors. Thirteen amateur soccer players (age 23.3±3.9 years, height 1.78±0.05?m, body mass 74.8±3.6?kg; mean±s) were tested during the 2000–2001 soccer season. Muscle strength of the quadriceps and hamstrings was measured on an isokinetic dynamometer. A 90?min soccer-specific intermittent exercise protocol, incorporating a 15?min half-time intermission, was developed to provide fatiguing exercise corresponding in work rate to a game of soccer. The exercise protocol, performed on a programmable motorized treadmill, consisted of the different intensities observed during soccer match-play (e.g. walking, jogging, running, sprinting). Muscle strength was assessed before exercise, at half-time and immediately after exercise. A repeated-measures analysis of variance showed significant reductions (P?<0.001) in peak torque for both the quadriceps and hamstrings at all angular velocities (concentric: 1.05, 2.09, 5.23 rad?·?s?1; eccentric: 2.09 rad?·?s?1). The peak torque of the knee extensors (KE) and knee flexors (KF) was greater before exercise [KE: 232±37, 182±34, 129±27, 219±41?N?·?m at 1.05, 2.09 and 5.23 rad?·?s?1 (concentric) and 2.09 rad?·?s?1 (eccentric), respectively; KF: 126±20, 112±19, 101±16, 137±23?N?·?m] than at half-time (KE: 209±45, 177±35, 125±36, 214±43?N?·?m; KF: 114±31, 102±20, 92±15, 125±25?N?·?m) and greater at half-time than after exercise (KE: 196±43, 167±35, 118±24, 204±43?N?·?m; KF: 104±25, 95±21, 87±13, 114±27?N?·?m). For the hamstrings?:?quadriceps ratio, significant changes were found (P?<0.05) for both legs, the ratio being greater before than after exercise. For fast?:?slow speed and left?:?right ratios, no significant changes were found. We conclude that there is a progressive reduction in muscle strength that applies across a range of functional characteristics during exercise that mimics the work rate in soccer.  相似文献   

16.
Abstract

This study investigated the effects of knee localised muscle damage on running kinematics at varying speeds. Nineteen young women (23.2 ± 2.8 years; 164 ± 8 cm; 53.6 ± 5.4 kg), performed a maximal eccentric muscle damage protocol (5 × 15) of the knee extensors and flexors of both legs at 60 rad · s-1. Lower body kinematics was assessed during level running on a treadmill at three speeds pre- and 48 h after. Evaluated muscle damage indices included isometric torque, muscle soreness and serum creatine kinase activity. The results revealed that all indices changed significantly after exercise, indicating muscle injury. Step length decreased and stride frequency significantly increased 48 h post-exercise only at the fastest running speed (3 m · s-1). Support time and knee flexion at toe-off increased only at the preferred transition speed and 2.5 m · s-1. Knee flexion at foot contact, pelvic tilt and obliquity significantly increased, whereas hip extension during stance-phase, knee flexion during swing-phase, as well as knee and ankle joints range of motion significantly decreased 48 h post-exercise at all speeds. In conclusion, the effects of eccentric exercise of both knee extensors and flexors on particular tempo-spatial parameters and knee kinematics of running are speed-dependent. However, several pelvic and lower joint kinematics present similar behaviour at the three running speeds examined. These findings provide new insights into how running kinematics at different speeds are adapted to compensate for the impaired function of the knee musculature following muscle damage.  相似文献   

17.
Abstract

Aim: To investigate the effect of different water immersion (WI) treatments on recovery from intermittent shuttle running exercise in comparison to an ecologically relevant control.

Methods: Forty males performed 90 minutes intermittent shuttle running, following which they were assigned to either: (1) 12-min standing WI at 12°C; (2) 12-min standing WI at 35°C; (3) 2-min seated WI at 12°C; (4) an ecologically relevant control consisting of 12 minutes walking at 5 km h?1. Muscle soreness, maximal voluntary contraction (MVC) of the knee flexors and extensors, hop distance, creatine kinase activity and myoglobin concentration were measured before exercise and in the 168 hours following the intervention. Between-group differences, time effects and interaction effects were investigated by mixed-model ANOVA.

Results: The shuttle running exercise induced an increase in muscle soreness (1, 24, 48 and 72 hours post-intervention) creatine kinase activity and myoglobin concentration (post-exercise and 1, 24 and 48 hours post-intervention), and reduced MVC of the knee extensors (11% reduction at 24 hours, remaining reduced at 48 and 72 hours), flexors (24% reduction at 24 hours, remaining reduced at 24, 48, 72 and 168 hours), and hop distance (24 and 48 hours). However, no between-group differences or interaction effects were evident for any of these parameters.

Conclusion: The WI protocols investigated were not better than light exercise in facilitating recovery from shuttle running exercise. Future studies examining the efficacy of WI as a recovery intervention should include a representative control condition to increase their relevance to sporting populations.  相似文献   

18.
Abstract

The aim of this study was to assess the effects of cold-water immersion (cryotherapy) on indices of muscle damage following a bout of prolonged intermittent exercise. Twenty males (mean age 22.3 years, s = 3.3; height 1.80 m, s = 0.05; body mass 83.7 kg, s = 11.9) completed a 90-min intermittent shuttle run previously shown to result in marked muscle damage and soreness. After exercise, participants were randomly assigned to either 10 min cold-water immersion (mean 10°C, s = 0.5) or a non-immersion control group. Ratings of perceived soreness, changes in muscular function and efflux of intracellular proteins were monitored before exercise, during treatment, and at regular intervals up to 7 days post-exercise. Exercise resulted in severe muscle soreness, temporary muscular dysfunction, and elevated serum markers of muscle damage, all peaking within 48 h after exercise. Cryotherapy administered immediately after exercise reduced muscle soreness at 1, 24, and 48 h (P < 0.05). Decrements in isometric maximal voluntary contraction of the knee flexors were reduced after cryotherapy treatment at 24 (mean 12%, s x  = 4) and 48 h (mean 3%, s x  = 3) compared with the control group (mean 21%, s x  = 5 and mean 14%, s x  = 5 respectively; P < 0.05). Exercise-induced increases in serum myoglobin concentration and creatine kinase activity peaked at 1 and 24 h, respectively (P < 0.05). Cryotherapy had no effect on the creatine kinase response, but reduced myoglobin 1 h after exercise (P < 0.05). The results suggest that cold-water immersion immediately after prolonged intermittent shuttle running reduces some indices of exercise-induced muscle damage.  相似文献   

19.
Abstract

In this study, we examined the long-term reductions in maximal isometric force (MIF) caused by a protocol of repeated maximal isometric contractions at long muscle length. Furthermore, we wished to ascertain whether the reductions in MIF are dependent on muscle length — that is, are the reductions in MIF more pronounced when the muscle contracts at a short length. The MIF of the elbow flexors of seven young male volunteers was measured at five different elbow angles between 50° and 160°. On a separate day, the participants performed 50 maximal voluntary isometric muscle contractions with the elbow flexors at a lengthened positions that is, with the shoulder hyperextended at 45° and the elbow joint fixed at 140°. Following this exercise, the MIF at the five elbow angles, range of motion, muscle soreness and plasma creatine kinase activity were measured at 24 h intervals for 4 days. On day 1, the decline in MIF was higher at the more acute elbow angles of 50° (42±8%) and 70° (39±8%; both P<0.01) than at 90° (26±4%) and 140° (16±3%; both P<0.01). No significant reduction in MIF was evident at an elbow angle of 160°. Maximal isometric force at an elbow angle of 140° was fully restored on day 3, whereas at an angle of 50° it remained depressed for the 4 day observation period. Restoration of MIF was a function of the elbow angle, with force recovery being less at the smaller angles. The range of motion was decreased by 14±2° on day 1 (P<0.01) and did not return to baseline values by day 4. Muscle soreness ratings remained significantly elevated for the 4 day period. Serum creatine kinase peaked on day 1 (522±129 IU, P<0.01) and decreased thereafter. We conclude that the disproportionate decrease in MIF at the small elbow angles and the length-specific recovery in MIF after repeated maximal isometric contractions at long muscle length may be explained by the presence of overstretched sarcomeres that increased in series compliance of the muscle, therefore causing a rightward shift of the force-length relationship.  相似文献   

20.
Surface electromyographic (EMG) signals were recorded from the hamstring muscles during six sets of submaximal isokinetic (2.6 rad s -1 ) eccentric (11 men, 9 women) or concentric (6 men, 4 women) contractions. The EMG per unit torque increased during eccentric (P < 0.01) but not during concentric exercise. Similarly, the median frequency increased during eccentric (P < 0.01) but not during concentric exercise. The EMG per unit torque was lower for submaximal eccentric than maximum isometric contractions (P < 0.001), and lower for submaximal concentric than maximum isometric contractions (P < 0.01). The EMG per unit torque was lower for eccentric than concentric contractions (P < 0.05). The median frequency was higher for submaximal eccentric than maximum isometric contractions (P < 0.001); it was similar, however, between submaximal concentric and maximum isometric contractions (P = 0.07). Eccentric exercise resulted in significant isometric strength loss (P < 0.01), pain (P < 0.01) and muscle tenderness (P < 0.05). The greatest strength loss was seen 1 day after eccentric exercise, while the most severe pain and muscle tenderness occurred 2 days after eccentric exercise. A lower EMG per unit torque is consistent with the selective recruitment of a small number of motor units during eccentric exercise. A higher median frequency during eccentric contractions may be explained by selective recruitment of fast-twitch motor units. The present results are consistent with the theory that muscle damage results from excessive stress on a small number of active fibres during eccentric contractions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号