首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

The aim of the current study was to investigate the validity and reliability of a radio frequency-based system for accurately tracking athlete movement within wheelchair court sports. Four wheelchair-specific tests were devised to assess the system during (i) static measurements; (ii) incremental fixed speeds; (iii) peak speeds; and (iv) multidirectional movements. During each test, three sampling frequencies (4, 8 and 16 Hz) were compared to a criterion method for distance, mean and peak speeds. Absolute static error remained between 0.19 and 0.32 m across the session. Distance values (test (ii)) showed greatest relative error in 4 Hz tags (1.3%), with significantly lower errors seen in higher frequency tags (<1.0%). Relative peak speed errors of <2.0% (test (iii)) were revealed across all sampling frequencies in relation to the criterion (4.00 ± 0.09 m · sˉ1). Results showed 8 and 16 Hz sampling frequencies displayed the closest-to-criterion values, whilst intra-tag reliability never exceeded 2.0% coefficient of variation (% CV) during peak speed detection. Minimal relative distance errors (<0.2%) were also seen across sampling frequencies (test (iv)). To conclude, the indoor tracking system is deemed an acceptable tool for tracking wheelchair court match play using a tag frequency of 8 or 16 Hz.  相似文献   

2.
The purpose of this study was to assess the validity of accelerometers using force plates (i.e., ground reaction force (GRF)) during the performance of different tasks of daily physical activity in children. Thirteen children (10.1 (range 5.4–15.7) years, 3 girls) wore two accelerometers (ActiGraph GT3X+ (ACT), GENEA (GEN)) at the hip that provide raw acceleration signals at 100 Hz. Participants completed different tasks (walking, jogging, running, landings from boxes of different height, rope skipping, dancing) on a force plate. GRF was collected for one step per trial (10 trials) for ambulatory movements and for all landings (10 trials), rope skips and dance procedures. Accelerometer outputs as peak loading (g) per activity were averaged. ANOVA, correlation analyses and Bland–Altman plots were computed to determine validity of accelerometers using GRF. There was a main effect of task with increasing acceleration values in tasks with increasing locomotion speed and landing height (P < 0.001). Data from ACT and GEN correlated with GRF (r = 0.90 and 0.89, respectively) and between each other (r = 0.98), but both accelerometers consistently overestimated GRF. The new generation of accelerometer models that allow raw signal detection are reasonably accurate to measure impact loading of bone in children, although they systematically overestimate GRF.  相似文献   

3.
The validity of an Ultra-wideband (UWB) positioning system was investigated during linear and change-of-direction (COD) running drills. Six recreationally-active men performed ten repetitions of four activities (walking, jogging, maximal acceleration, and 45º COD) on an indoor court. Activities were repeated twice, in the centre of the court and on the side. Participants wore a receiver tag (Clearsky T6, Catapult Sports) and two reflective markers placed on the tag to allow for comparisons with the criterion system (Vicon). Distance, mean and peak velocity, acceleration, and deceleration were assessed. Validity was assessed via percentage least-square means difference (Clearsky-Vicon) with 90% confidence interval and magnitude-based inference; typical error was expressed as within-subject standard deviation. The mean differences for distance, mean/peak speed, and mean/peak accelerations in the linear drills were in the range of 0.2–12%, with typical errors between 1.2 and 9.3%. Mean and peak deceleration had larger differences and errors between systems. In the COD drill, moderate-to-large differences were detected for the activity performed in the centre of the court, increasing to large/very large on the side. When filtered and smoothed following a similar process, the UWB-based positioning system had acceptable validity, compared to Vicon, to assess movements representative of indoor sports.  相似文献   

4.
Abstract

The aim of the present study was to examine the effects of movement intensity and path linearity on global positioning system (GPS) distance validity and reliability. One participant wore eight 1-Hz GPS receivers while walking, jogging, running, and sprinting over linear and non-linear 200-m courses. Five trials were performed at each intensity of movement on each 200-m course. One receiver was excluded from analysis due to errors during data collection. The results from seven GPS receivers showed the mean (±s) and percent bias of the GPS distance values on the 200-m linear course were 205.8 ± 2.4 m (2.8%), 201.8 ± 2.8 m (0.8%), 203.1 ± 2.2 m (1.5%), and 205.2 ± 4 m (2.5%) for the walk, jog, run, and sprint trial respectively. Walk and sprint distances were significantly different from jogging and running distances (P < 0.05). The GPS distance values on the 200-m non-linear course were 198.9 ± 3.5 m (?0.5%), 188.3 ± 2 m (?5.8%), 184.6 ± 2.9 m (?7.7%), and 180.4 ± 5.7 m (?9.8%) for the walk, jog, run, and sprint trial respectively; these were significantly lower than those for the corresponding values on the linear course (P < 0.05). Differences between all non-linear movement intensities were significant (P < 0.05). The overall coefficient of variation within and between receivers was 2.6% and 2.8% respectively. Path linearity and movement intensity appear to affect GPS distance accuracy via inherent positioning errors, update rate, and conditions of use; reliability decreases with movement intensity.  相似文献   

5.
This study assessed the validity of a tri-axial accelerometer worn on the upper body to estimate peak forces during running and change-of-direction tasks. Seventeen participants completed four different running and change-of-direction tasks (0°, 45°, 90°, and 180°; five trials per condition). Peak crania-caudal and resultant acceleration was converted to force and compared against peak force plate ground reaction force (GRF) in two formats (raw and smoothed). The resultant smoothed (10 Hz) and crania-caudal raw (except 180°) accelerometer values were not significantly different to resultant and vertical GRF for all running and change-of-direction tasks, respectively. Resultant accelerometer measures showed no to strong significant correlations (r = 0.00–0.76) and moderate to large measurement errors (coefficient of variation [CV] = 11.7–23.9%). Crania-caudal accelerometer measures showed small to moderate correlations (r = ? 0.26 to 0.39) and moderate to large measurement errors (CV = 15.0–20.6%). Accelerometers, within integrated micro-technology tracking devices and worn on the upper body, can provide a relative measure of peak impact force experienced during running and two change-of-direction tasks (45° and 90°) provided that resultant smoothed values are used.  相似文献   

6.
Abstract

This study aimed to elucidate the movements requiring greater trunk accelerations and its frequencies during badminton games, and compare the acceleration components among such movements. Trunk acceleration was measured using a triaxial accelerometer during badminton games. The moments that generated >4 G resultant acceleration were extracted, and movements consistent with the extracted moments were identified. We calculated the extracted movement ratio and frequency and compared the resultant, mediolateral, vertical and anteroposterior accelerations between the top five extracted movements. There were 1,342 movements that generated >4 G [mean, 7.72 (95% confidence interval, 7.31–8.14) cases/min]. The top five movements were lunging during underhand strokes with the dominant hand side leg, landing after overhand strokes on the dominant and non-dominant hand side leg, and cutting from a split step using the dominant and non-dominant hand side leg. Landing on the dominant hand side leg had a greater resultant acceleration than the other movements and had the greatest impact during the badminton game. Lunging during underhand strokes on the dominant hand side leg had greater mediolateral acceleration than the other movements. These results reflected the properties of badminton.  相似文献   

7.
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.  相似文献   

8.
Self-recall training diaries are a frequently used tool to quantify training load and training information. While accelerometers are predominantly used to validate training diaries, they are unable to validate contextual training information. Thus this study aimed to examine the novel use of data fusion from a wearable camera device (SenseCam) and accelerometer to validate a self-recall training diary. Thirty participants filled in a training diary for 1 day while simultaneously wearing a SenseCam and accelerometer. The training diary was validated using Bland–Altman plots, Spearman’s rank-order correlation, percentage agreement and κ measure of agreement between the diary and the SenseCam and accelerometer. The results demonstrated overall agreement, and no bias, between the training diary and the accelerometer for training intensity, and the SenseCam for duration of activity and travel time. A positive correlation was found for duration (r = 0.82, P < 0.001) and intensity (r = 0.67, P < 0.001). Hundred per cent agreement was found between the SenseCam and training diary for activity, training surface and footwear (κ = 1, P < 0.0001), with a lower agreement noted for sports played (97.3%, κ = 0.91, P < 0.0001). The self-recall training diary was found to be a valid measure of capturing training load and training information using the combined wearable camera device and accelerometer.  相似文献   

9.
The aim was to compare the physical characteristics of under-18 academy and schoolboy rugby union competition by position (forwards and backs). Using a microsensor unit, match characteristics were recorded in 66 players. Locomotor characteristics were assessed by maximum sprint speed (MSS) and total, walking, jogging, striding and sprinting distances. The slow component (<2 m · s?1) of PlayerLoadTM (PLslow), which is the accumulated accelerations from the three axes of movement, was analysed as a measure of low-speed activity (e.g., rucking). A linear mixed-model was assessed with magnitude-based inferences. Academy forwards and backs almost certainly and very likely covered greater total distance than school forwards and backs. Academy players from both positions were also very likely to cover greater jogging distances. Academy backs were very likely to accumulate greater PLslow and the academy forwards a likely greater sprinting distance than school players in their respective positions. The MSS, total, walking and sprinting distances were greater in backs (likely-almost certainly), while forwards accumulated greater PLslow (almost certainly) and jogging distance (very likely). The results suggest that academy-standard rugby better prepares players to progress to senior competition compared to schoolboy rugby.  相似文献   

10.
Abstract

The goal of this paper was to investigate the possible trade-off between peak hand acceleration and accuracy and consistency of hand strikes performed by martial artists of different training experiences. Ten male martial artists with training experience ranging from one to nine years volunteered to participate in the experiment. Each participant performed 12 maximum effort goal-directed strikes. Hand acceleration during the strikes was obtained using a tri-axial accelerometer block. A pressure sensor matrix was used to determine the accuracy and consistency of the strikes. Accuracy was estimated by the radial distance between the centroid of each subject's 12 strikes and the target, whereas consistency was estimated by the square root of the 12 strikes mean squared distance from their centroid. We found that training experience was significantly correlated to hand peak acceleration prior to impact (r 2=0.456, p =0.032) and accuracy (r 2=0. 621, p=0.012). These correlations suggest that more experienced participants exhibited higher hand peak accelerations and at the same time were more accurate. Training experience, however, was not correlated to consistency (r 2=0.085, p=0.413). Overall, our results suggest that martial arts training may lead practitioners to achieve higher striking hand accelerations with better accuracy and no change in striking consistency.  相似文献   

11.
This study establishes tri-axial activity count (AC) cut-points for the GT3X+ accelerometer to classify physical activity intensity in overweight and obese adults. Further, we examined the accuracy of established and novel energy expenditure (EE) prediction equations based on AC and other metrics. Part 1: Twenty overweight or obese adults completed a 30 minute incremental treadmill walking protocol. Heart rate (HR), EE, and AC were measured using the GT3X+ accelerometer. Part 2: Ten overweight and obese adults conducted a self-paced external walk during which EE, AC, and HR were measured. Established equations (Freedson et al., 1998; Sasaki et al., 2011) overestimated EE by 40% and 31%, respectively (< .01). Novel gender-specific prediction equations provided good estimates of EE during treadmill and outdoor walking (standard error of the estimate = .91 and .65, respectively). We propose new cut-points and prediction equations to estimate EE using the GT3X+ tri-axial accelerometer in overweight and obese adults.  相似文献   

12.
The purpose of this study was to examine the validity of the Smarthealth watch (Salutron, Inc., Fremont, California, USA), a heart rate monitor that includes a wristwatch without an accompanying chest strap. Twenty-five individuals participated in 3-min periods of standing, 2.0 mph walking, 3.5 mph walking, 4.5 mph jogging, and 6.0 mph running. Heart rate was simultaneously measured and recorded at 60-sec intervals using three methods: the Smarthealth wristwatch, the Polar Vantage XL monitor with an accompanying chest strap (Kempele, Finland), and an electrocardiograph, which served as the criterion method. The heart rates obtained from the Smarthealth watch were highly correlated with those from the electrocardiograph (r ≥ .95) and the standard error of estimate was below 5 bpm for all measurements. Additionally, correlation coefficients and standard errors of estimate between the Smarthealth watch and Polar heart rate monitor were ≥.97 and <3.7 bpm, respectively. However, the Smarthealth watch exhibited a reduced ability to detect a heart rate during the 4.5 and 6.0 mph conditions compared to the Polar heart rate monitor (6% and 13.9% reduced ability, respectively). The Smarthealth watch appears to be a valid device for monitoring heart rate while standing and during treadmill exercise involving walking and jogging in a healthy young adult sample, although it may not be able to consistently detect a heart rate when body motion is excessive.  相似文献   

13.
The purposes of the study were to track weightlifters' barbell acceleration with a portable accelerometer over three training sessions to examine test–retest reliability and to compare peak barbell acceleration at different training intensities. Twelve nationally ranked weightlifters volunteered for this study. The portable accelerometer was attached to the right side of the barbell to measure barbell resultant acceleration during the snatch lift at a sampling frequency of 100 Hz. The data were collected over three training sessions at intensity levels of 80%, 85%, and 90% of one repetition maximum. The data were analyzed using intra-class correlation coefficients (ICCs) for the three training sessions and one-way repeated measure ANOVA to compare the difference in peak barbell acceleration at three intensities. Results showed that the device was highly reliable with an ICC of 0.88 and 95% confidence interval of 0.81–0.93. There were significant differences in peak barbell acceleration at various lifting intensities, indicating a decline of the acceleration as the mass of the barbell became heavier. The portable accelerometer seems useful in measuring barbell acceleration data, which can be analyzed in future studies to monitor a weightlifter's performance in a practical setting instead of testing at a laboratory.  相似文献   

14.
Race walking is an event where the knee must be straightened from first contact with the ground until midstance. The aim of this study was to compare knee angle measurements between 2D videography and 3D optoelectronic systems. Passive retroreflective markers were placed on the right leg of 12 race walkers and 3D marker coordinate data captured (250 Hz), with 2D video data (100 Hz) recorded simultaneously. Knee angle data were first derived based on the markers’ coordinates, and separately by using a 3D model that also incorporated thigh and shank clusters; the video data were analysed using both automatic tracking and manual digitising, creating four conditions overall. Differences were calculated between conditions for stance (using root mean square values), and at discrete events. There were few differences between systems, although the 3D model produced larger angles at midstance than using automatic tracking and marker coordinates (by 3 – 6°, P < 0.05). These differences might have occurred because of how the 3D model locates the hip joint, and because of the addition of marker clusters. 2D videography gave similar results to the 3D model when using manual digitising, as it allowed for errors caused by skin movement to be corrected.  相似文献   

15.
Race walking is an Olympic event where no visible loss of contact should occur and the knee must be straightened until midstance. The purpose of this study was to analyse ground reaction forces of world-class race walkers and associate them with key spatiotemporal variables. Nineteen athletes race walked along an indoor track and made contact with two force plates (1000 Hz) while being filmed using high-speed videography (100 Hz). Race walking speed was correlated with flight time (r = .46, p = .049) and flight distance (r = .69, p = .001). The knee's movement from hyperextension to flexion during late stance meant the vertical push-off force that followed midstance was smaller than the earlier loading peak (p < .001), resulting in a flattened profile. Athletes with narrower stride widths experienced reduced peak braking forces (r = .49, p = .046), peak propulsive forces (r = .54, p = .027), peak medial forces (r = .63, p = .007) and peak vertical push-off forces (r = .60, p = .011). Lower fluctuations in speed during stance were associated with higher stride frequencies (r = .69, p = .001), and highlighted the importance of avoiding too much braking in early stance. The flattened trajectory and consequential decrease in vertical propulsion might help the race walker avoid visible loss of contact (although non-visible flight times were useful in increasing stride length), while a narrow stride width was important in reducing peak forces in all three directions and could improve movement efficiency.  相似文献   

16.
LivePod LP2检测人体运动中能量消耗水平的信、效度检验   总被引:2,自引:1,他引:1  
加速度传感器以其轻便、客观、精确等特点,在人体体力活动测量与评价中被广泛使用。LivePod LP2是一款国产新型加速度传感器,它基于3轴加速度MEMS传感器技术,采用人体动作智能模糊识别模型和个性化能耗模型测量人体运动中的能量消耗。对LivePodLP2在测量人体运动能量消耗的信度和效度水平进行了验证。26名受试者在4个不同部位佩戴LivePod LP2,在3种速度下(4km/h、6km/h、8km/h)运动。通过计算ICC,发现其值处于0.978~0.997;采用相关分析、配对样本t检验以及Bland-Altman分析法等方法对仪器和MAXII测量数据分析表明:LivePod LP2佩戴于右侧臀部上方,在慢跑速度水平下效度水平最高。LivePod LP2可以用于记录体力活动能量消耗,在日常应用中,用户可以选择将LivePod LP2固定于腰部来监测运动能量消耗情况。  相似文献   

17.
Abstract

The capturing of movements by means of wearable sensors has become increasingly popular in order to obtain sport performance measures during training or competition. The purpose of the current study was to investigate the feasibility of using body worn accelerometers to identify previous highlighted performance related biomechanical changes in terms of substantial differences across skill levels and skating phases. Twenty-two ice hockey players of different caliber were equipped with two 3D accelerometers, located on the skate and the waist, as they performed 30 m forward skating sprints on an ice rink. Two measures of the temporal stride characteristics (contact time and stride time) and one measure of the propulsive power (stride propulsion) of a skating stride were calculated and checked for discriminating effects across (i) skill levels and (ii) sprint phases as well as for their (iii) strength of association with the sprint performance (total sprint time). High caliber players showed an increased stride propulsion (+22%, P?<?0.05) and shorter contact time (?5%, P?<?0.05). All three analysed variables highlighted substantial biomechanical differences between the accelerative and constant velocity phases (P?<?0.05). Stride propulsion of acceleration strides primarily correlated to total sprint time (r?=??0.57, P?<?0.05). The results demonstrate the potential of accelerometers to assess skating technique elements such as contact time or elements characterizing the propulsive power such as center of mass acceleration, to gauge skating performance. Thus, the findings of this study might contribute to establishing wearable sensors for in-field ice hockey skating performance analysis.  相似文献   

18.
The purpose of this study was to determine the association between weightlifting performance and vertical barbell acceleration patterns. Barbell kinematic time-series data were tracked from 18 snatches from six weightlifters during a regional weightlifting competition. These data were used to calculate vertical barbell accelerations. Time-series data were normalised to 100% of lift phase, defined as the time interval between barbell lift-off and maximum height of the barbell during each snatch lift. The time-series data were then entered into a pattern recognition algorithm that extracted principal patterns and calculated principal pattern scores. Body mass-normalised lift weight, which was used to quantify weightlifting performance, was significantly correlated (r = 0.673; P = 0.033) with a pattern that captured a difference in peak vertical barbell acceleration between the transition and the second pull phase. This correlation indicated that barbell acceleration profiles of higher weight snatch lifts were characterised by smaller decreases in acceleration during the second knee bend and smaller peak acceleration during the second pull phase. Weightlifting coaches and sports scientist should monitor and track vertical acceleration of the barbell, with focus on acceleration profiles that limit (1) deceleration during the transition phase between the first and second pull and (2) peak acceleration during the second pull phase of the snatch.  相似文献   

19.
20.
Abstract

There has been no previous investigation of the concurrent validity and reliability of the current 5 Hz global positioning system (GPS) to assess sprinting speed or the reliability of integrated GPS–accelerometer technology. In the present study, we wished to determine: (1) the concurrent validity and reliability of a GPS and timing gates to measure sprinting speed or distance, and (2) the reliability of proper accelerations recorded via GPS–accelerometer integration. Nineteen elite youth rugby league players performed two over-ground sprints and were simultaneously assessed using GPS and timing gates. The GPS measurements systematically underestimated both distance and timing gate speed. The GPS measurements were reliable for all variables of distance and speed (coefficient of variation [CV] = 1.62% to 2.3%), particularly peak speed (95% limits of agreement [LOA] = 0.00 ± 0.8 km · h?1; CV = 0.78%). Timing gates were more reliable (CV = 1% to 1.54%) than equivalent GPS measurements. Accelerometer measurements were least reliable (CV = 4.69% to 5.16%), particularly for the frequency of proper accelerations (95% LOA = 1.00 ± 5.43; CV = 14.12%). Timing gates and GPS were found to reliably assess speed and distance, although the validity of the GPS remains questionable. The error found in accelerometer measurements indicates the limits of this device for detecting changes in performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号