共查询到20条相似文献,搜索用时 406 毫秒
1.
Cubranic Z Madzar Z Matijevic S Dvornik S Fisic E Tomulic V Kunisek J Laskarin G Kardum I Zaputovic L 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2012,22(2):225-236
Introduction:
This study aimed to assess whether heart fatty acid-binding protein (H-FABP) and glycogen phosphorylase isoenzyme BB (GPBB) could be used for the accurate diagnosis of acute myocardial infarction (AMI) in acute coronary syndrome (ACS) patients.Materials and methods:
The study included 108 ACS patients admitted to a coronary unit within 3 h after chest pain onset. AMI was distinguished from unstable angina (UA) using a classical cardiac troponin I (cTnI) assay. H-FABP and GPBB were measured by ELISA on admission (0 h) and at 3, 6, 12, and 24 h after admission; their accuracy to diagnose AMI was assessed using statistical methods.Results:
From 92 patients with ACS; 71 had AMI. H-FABP and GPBB had higher peak value after 3 h from admission than cTnI (P = 0.001). Both markers normalized at 24 h. The area under the receiver operating characteristic curves was significantly greater for both markers in AMI patients than in UA patients at all time points tested, including admission (P < 0.001). At admission, the H-FABP (37%) and GPBB (40%) sensitivities were relatively low. They increased at 3 and 6 h after admission for both markers and decreased again after 24 h. It was 40% for H-FABP and approximately 2-times lower for GPBB (P < 0.01). In AMI patients, both biomarkers had similar specificities, positive- and negative-predictive values, positive and negative likelihood ratios, and risk ratios for AIM.Conclusion:
H-FABP and GPBB can contribute to early AMI diagnosis and can distinguish AMI from UA. 相似文献2.
Matteo Vidali Enrica Verzotti Nicole Cabraz Francesca Santi Alessia Puma Giorgio Bellomo Alessandro Lupi Giuseppe Lippi Gian Carlo Avanzi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(3):421-429
Introduction
The aim of this study was to identify clinical variables which may be independently associated with positivity of a cardiac troponin I (cTnI) assay in a large population of patients admitted to the emergency department (ED).Materials and methods
3166 subjects, with at least two troponin I tests ordered within 6 hours in the ED, were studied. Patient data were statistically analyzed to identify clinical associations with increased values of Troponin I.Results
Although patients with diagnosis of acute coronary syndrome displayed troponin I values significantly higher than those of other groups, positivity to troponin I (> 40 ng/L) was also observed in patients with other clinical conditions. In multivariate analysis, age, elevated heart rate and electrocardiographyc changes were independently associated with troponin I positivity at admission. In the whole study population troponin I positivity exhibited high sensitivity and negative predictive value, counterbalanced by low specificity and limited positive predictive value.Conclusions
Troponin I positivity should be combined with history and clinical evaluation and cautiously interpreted in the ED, especially in patients exhibiting factors associated with higher troponin I levels such as older age, elevated heart rate or ECG changes.Key words: troponin I, acute coronary syndrome, emergency service, hospital, chest pain 相似文献3.
Ka?an Huysal Yasemin U. Budak Ayse Ulusoy Karaca Murat Aydos Serdar Kahvecio?lu Mehtap Bulut Murat Polat 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(2):211-217
Introduction
Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures.Materials and methods:
We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semi-quantitative urine culture.Results:
Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8–65.3), and a negative predictive value (NPV) of 88.8% (95% Cl = 85.0–91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test.Conclusions:
Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis results do not accurately predict the outcome of culture. 相似文献4.
Lippi G Cervellin G Aloe R Montagnana M Salvagno GL Guidi GC 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2012,22(1):127-129
Introduction:
The measurement of cardiospecific troponins is pivotal in the diagnostic and prognostic approach of patients with suspected acute myocardial infarction (AMI). However, no information is available on the commutability of results between the novel highly-sensitive (HS) troponin T (TnT) and I (TnI) immunoassays.Materials and methods:
The study population consisted in 47 consecutive patients presenting at the emergency department (ED) of the Academic Hospital of Parma with suspected AMI. TnI was measured with the novel prototype Beckman Coulter HS-AccuTnI immunoassay on Access 2, whereas TnT was measured with the Roche HS-TnT immunoassay on Cobas.Results:
Eight out of the 47 patients (17%) were finally diagnosed as having an AMI. The overall correlation between TnT and TnI for total patient group was acceptable (r = 0.944; P < 0.01). Nevertheless, when the analysis of data was carried out in separate groups according to the final diagnosis of AMI, two different equation results were obtained, i.e., HS-TnT = HS-AccuTnI × 0.349 + 20 (r = 0.823; P < 0.01) in non-AMI patients, and HS-TnT = HS-AccuTnI × 0.134 + 67 (r = 0.972; P < 0.01) in those with AMI.Conclusions:
This study suggests the existence of two biological relationships between TnI and TnT in plasma, depending on the source of release from the myocardium. Moreover, the non-commutability of data between HS-TnT and HS-AccuTnI jeopardizes the clinical decision making, makes it impossible to calculate the delta or reference change value using the two biomarkers and to finally establish a reliable kinetics of troponin release from the injured myocardium. 相似文献5.
Xi Zhang Goce Dimeski Chamindie Punyadeera 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(2):258-265
Introduction:
We have previously shown that the concentrations of D-dimer are significantly elevated in saliva compared with plasma. Saliva offers several advantages compared with blood analysis. We hypothesised that human saliva contains plasminogen activator inhibitor-1 (PAI-1) and that the concentrations are not affected by the time of saliva collection. The aim was to adopt and validate an immunoassay to quantify PAI-1 concentrations in saliva and to determine whether saliva collection time has an influence in the measurement.Materials and methods:
Two saliva samples (morning and afternoon) from the same day were collected from healthy subjects (N = 40) who have had no underlying heart conditions. A customized AlphaLISA® immunoassay (PerkinElmer®, MA, USA) was adopted and used to quantify PAI-1 concentrations. We validated the analytical performance of the customized immunoassay by calculating recovery of known amount of analyte spiked in saliva.Results:
The recovery (95.03%), intra- (8.59%) and inter-assay (7.52%) variations were within the acceptable ranges. The median salivary PAI-1 concentrations were 394 pg/mL (interquartile ranges (IQR) 243.4–833.1 pg/mL) in the morning and 376 (129.1–615.4) pg/mL in the afternoon and the plasma concentration was 59,000 (24,000–110,000) pg/mL. Salivary PAI-1 did not correlate with plasma (P = 0.812).Conclusions:
The adopted immunoassay produced acceptable assay sensitivity and specificity. The data demonstrated that saliva contains PAI-1 and that its concentration is not affected by the time of saliva collection. There is no correlation between salivary and plasma PAI-1 concentrations. Further studies are required to demonstrate the utility of salivary PAI-1 in CVD risk factor studies. 相似文献6.
Dra?an Butorac Ivana ?elap Sanja Ka?kov Vera Robi? Tomislav Mileti? Zlata Flegar Me?tri? Andrea Hulina Krunoslav Kuna Tihana ?ani? Grubi?i? Marija Grdi? Rajkovi? 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(2):273-280
Introduction
Postmenopausal women have higher risk of cardiovascular disease. One of the contributing factors could be reduced activity of anti-atherogenic enzyme paraoxonase 1 (PON1). The aim of this study was to examine differences in the lipid status, paraoxonase and arylesterase PON1 activities and PON1 phenotype in women with regular menstrual cycle and in postmenopausal women.Materials and methods:
The study included 51 women in reproductive age (25 in follicular and 26 in luteal phase of the menstrual cycle) and 23 women in postmenopause. Lipid parameters in sera were determined using original reagents and according to manufacturer protocol. PON1 activity in serum was assessed by spectrophotometric method with substrates: paraoxon and phenylacetate. PON1 phenotype was determined by double substrate method.Results:
Compared to the women in follicular and luteal phase, postmenopausal women have significantly higher concentration of triglyceride [0.9 (0.7–1.3), 0.7 (0.6–1.0) vs. 1.5 (0.9–1.7) mmol/L; P = 0.002], cholesterol [5.10 (4.78–6.10), 5.05 (4.70–5.40) vs. 6.30 (5.73–7.23) mmol/L; P < 0.001], LDL [3.00 (2.56–3.63), 3.00 (2.70–3.70) vs. 3.90 (3.23–4.50) mmol/L; P < 0.001], and apolipoprotein B [0.88 (0.75–1.00), 0.79 (0.68–1.00) vs. 1.07 (0.90–1.24) mmol/L; P = 0.002]. PON1 basal [104 (66–260), 106 (63–250) vs. 93 (71–165) U/L; P = 0.847] and salt-stimulated paraoxonase activity [210 (131–462), 211 (120–442) vs. 180 (139–296) U/L; P = 0.857] as well as arylesterase activity [74 (63–82), 70 (54–91) vs. 70 (60–81) kU/L; P = 0.906] and PON1 phenotype (P = 0.810) were not different in the study groups.Conclusion:
There are no differences in PON1 activity and PON1 phenotype between women with regular menstrual cycle and postmenopausal women. 相似文献7.
Ayfer Colak Burak Toprak Nese Dogan Fusun Ustuner 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(3):321-325
Introduction:
Studies about vitamin D [25(OH)D] stability in plasma are limited and preanalytical variables such as tube type may affect results. We aimed to evaluate effect of storage conditions, sample type and some preanalytical variables on vitamin D concentration.Materials and methods:
Blood samples from 15 healthy subjects were centrifuged at different temperatures and stored under different conditions. Serum and plasma 25(OH)D difference, effect of centrifugation temperature and common storage conditions were investigated.Results:
There was no difference between serum and plasma vitamin D concentration. Centrifugation temperature had no impact on vitamin D concentration. 25(OH)D is stable under common storage conditions: 4 hours at room temperature, 24 hours at 2–8 °C, 7 days at −20 °C, 3 months at −80 °C.Conclusion:
Vitamin D does not require any special storage conditions and refrigeration. Both serum and plasma can be used for measurement. 相似文献8.
9.
Fethullah Gerin Dilber Coban Ramazan Ozgur Baykan Onder Sirikci Goncagul Haklar 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(1):180-182
Introduction:
Serum blood collection tubes with separator gel are widely used by many laboratories for chemistry analyses. We describe a case of a primary blood collection tube filled with blood sample and a floating separator gel.Materials and methods:
The blood sample was collected from a 51 years old female in intensive care unit with the diagnosis of pneumonia into a BD Vacutainer SST tube (Becton Dickinson, NJ, USA) containing serum separator gel and conveyed to the core laboratory of Marmara University Hospital within 30 minutes from collection. Sample was immediately centrifuged at room temperature at 1500 × g for 10 minutes.Results:
The analyses revealed a highly increased total protein concentration of 145 g/L (reference interval 64–83 g/L). The nephelometric analyses showed an elevated serum IgG concentration of 108 g/L (reference interval 6.5–16 g/L) and IgG lambda monoclonal band was determined by serum immunofixation electrophoresis.Conclusion:
Limitation of the separator gel tubes in patients with a high plasma density and its possible effects on test results and laboratory costs should be remembered. The clinical diagnosis stated in the information system should also reveal known comorbid conditions besides the apparent admission reason. This information would avoid resampling, additional testing, and communication efforts with the clinicians. 相似文献10.
Gabriel Lima-Oliveira Gian Luca Salvagno Giuseppe Lippi Elisa Danese Matteo Gelati Martina Montagnana Geraldo Picheth Gian Cesare Guidi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(3):343-349
Background:
Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests.Materials and methods:
A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV).Results:
A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104–117) and 111 (107–120) vs. 109 (102–118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9–34.8) vs. 34.1 (32.2–35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV.Conclusion:
A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake. 相似文献11.
Biljana Pejovi? Jelena Eri?-Marinkovi? Marija Pejovi? Jelena Kotur-Stevuljevi? Amira Peco-Anti? 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(3):450-459
Introduction
Acute kidney injury (AKI) is common in neonatal intensive care units (NICU). In recent years, every effort is made for early detection of AKI. Our hypothesis was that serum neutrophil gelatinase-associated lipocalin (sNGAL) may be a reliable screening test for early diagnosis of AKI in premature neonates after perinatal asphyxia. Therefore, our aim was to assess the diagnostic accuracy of sNGAL for AKI in premature asphyxiated neonates.Materials and methods
AKI was defined in the third day of life (DOL 3) as a serum creatinine (sCr) increase ≥ 26.5 μmol/L from baseline (the lowest previous sCr). According to the increase of sCr, AKI patients were divided in AKIN1 (sCr increase up to 1.9 baseline) and AKIN2 (sCr increase from 2.0 to 2.9 baseline). sNGAL levels were measured on DOL 1, 3 and 7.Results
AKI was diagnosed in 73 (0.676) of 108 enrolled premature asphyxiated neonates. Sixty one patients (0.836) were classified in AKIN1 and 12 patients (0.164) in AKIN2. sNGAL reached the maximal concentrations on DOL 1 within 4 hours after admission to NICU, being higher in AKI compared with no-AKI group (160.8 ± 113.1 vs. 87.1 ± 81.6; P < 0.001) as well as in AKIN2 compared with AKIN1 group (222.8 ± 112.9 vs. 147.8 ± 109.9; P < 0.001). The best areas under the receiver operating characteristic curves (AUC) for prediction of AKI were 0.72 [95% (0.62-0.80) P < 0.001] on DOL1 at 2h and 0.72 [95% (0.63-0.80) P < 0.001] at 4th hour after admission respectively. The corresponding sNGAL cutoff concentrations were 84.87 ng/mL (sensitivity 69.0% and specificity 71.9%) and 89.43 ng/mL (sensitivity 65.7% and specificity 74.3%).Conclusions
In premature asphyxiated neonates sNGAL measured within the first 4 hours of DOL 1 is predictive of the occurrence and severity of AKI. Therefore, plasma levels of NGAL may be used for early diagnosis of AKI in these patients.Key words: serum neutrophil gelatinase-associated lipocalin, acute kidney injury, premature neonates, biomarker 相似文献12.
Giuseppe Lippi Gianfranco Cervellin Camilla Mattiuzzi 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(2):193-200
Background:
A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis.Materials and methods:
We performed a systematic search on PubMed, Web of Science and Scopus to estimate the risk of spurious hemolysis in blood samples collected from intravenous catheters. A meta-analysis with calculation of Odds ratio (OR) and Relative risk (RR) along with 95% Confidence interval (95% CI) was carried out using random effect mode.Results:
Fifteen articles including 17 studies were finally selected. The total number of patients was 14,796 in 13 studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes, and 1251 in 4 studies assessing catheter and evacuated tubes versus catheter and manual aspiration. A significant risk of hemolysis was found in studies assessing catheter and evacuated tubes versus straight needle and evacuated tubes (random effect OR 3.4; 95% CI = 2.9–3.9 and random effect RR 1.07; 95% CI = 1.06–1.08), as well as in studies assessing catheter and evacuated tubes versus catheter and manual aspiration of blood (OR 3.7; 95% CI = 2.7–5.1 and RR 1.32; 95% CI = 1.24–1.40).Conclusions:
Sample collection through intravenous catheters is associated with significant higher risk of spurious hemolysis as compared with standard blood drawn by straight needle, and this risk is further amplified when intravenous catheter are associated with primary evacuated blood tubes as compared with manual aspiration. 相似文献13.
Daniel A. Klaus Michael C. Motal Ursula Burger-Klepp Corinna Marschalek Elisabeth M. Schmidt Diana Lebherz-Eichinger Claus G. Krenn Georg A. Roth 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(1):107-111
Introduction:
Zonulin is a eukaryotic protein structurally similar to Vibrio cholerae’s zonula occludens toxin. It plays an important role in the opening of small intestine tight junctions. The loss of gut wall integrity during sepsis might be pivotal and has been described in various experimental as well as human studies. Increased levels of zonulin could be demonstrated in diseases associated with increased intestinal inflammation, such as celiac disease and type 1 diabetes. We therefore investigated the role of plasma levels of zonulin in patients with sepsis as a non-invasive marker of gut wall integrity.Materials and methods:
Plasma level of zonulin was measured in 25 patients with sepsis, severe sepsis or septic shock according to ACCP/SCCM criteria at the first day of diagnosed sepsis. 18 non-septic post-surgical ICU-patients and 20 healthy volunteers served as control. Plasma levels were determined by using commercially available ELISA kit. Data are given as median and interquartile range (IQR).Results:
Significantly higher plasma concentration of zonulin were found in the sepsis group: 6.61 ng/mL (IQR 3.51–9.46), as compared to the to the post-surgical control group: 3.40 ng/mL (IQR 2.14–5.70) (P = 0.025), as well as to the healthy group: 3.55 ng/mL (IQR 3.14–4.14) (P = 0.008).Conclusion:
We were able demonstrate elevated levels of plasma zonulin, a potential marker of intestinal permeability in septic patients. Increased zonulin may serve as an additional mechanism for the observed increased intestinal permeability during sepsis and SIRS. 相似文献14.
Tijl Vermassen Charles Van Praet Filip Poelaert Nicolaas Lumen Karel Decaestecker Piet Hoebeke Simon Van Belle Sylvie Rottey Joris Delanghe 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(3):439-449
Introduction
Although prostatitis is a common male urinary tract infection, clinical diagnosis of prostatitis is difficult. The developmental mechanism of prostatitis is not yet unraveled which led to the elaboration of various biomarkers. As changes in asparagine-linked-(N-)-glycosylation were observed between healthy volunteers (HV), patients with benign prostate hyperplasia and prostate cancer patients, a difference could exist in biochemical parameters and urinary N-glycosylation between HV and prostatitis patients. We therefore investigated if prostatic protein glycosylation could improve the diagnosis of prostatitis.Materials and methods
Differences in serum and urine biochemical markers and in total urine N-glycosylation profile of prostatic proteins were determined between HV (N = 66) and prostatitis patients (N = 36). Additionally, diagnostic accuracy of significant biochemical markers and changes in N-glycosylation was assessed.Results
Urinary white blood cell (WBC) count enabled discrimination of HV from prostatitis patients (P < 0.001). Urinary bacteria count allowed for discriminating prostatitis patients from HV (P < 0.001). Total amount of biantennary structures (urinary 2A/MA marker) was significantly lower in prostatitis patients compared to HV (P < 0.001). Combining the urinary 2A/MA marker and urinary WBC count resulted in an AUC of 0.79, 95% confidence interval (CI) = (0.70–0.89) which was significantly better than urinary WBC count (AUC = 0.70, 95% CI = [0.59–0.82], P = 0.042) as isolated test.Conclusions
We have demonstrated the diagnostic value of urinary N-glycosylation profiling, which shows great potential as biomarker for prostatitis. Further research is required to unravel the developmental course of prostatic inflammation.Key words: diagnostic marker, prostatitis, urinary asparagine-linked glycosylation 相似文献15.
Yasemin U Budak Ka?an Huysal Hakan Demirci 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(1):97-102
Background
In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.Material and methods
Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.Results
The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).Conclusion
Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume 相似文献16.
Eva Fliser Ksenija Jerkovi? Tanja Vidovi? Maksimiljan Gorenjak 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2012,22(3):352-362
Introduction:
We present our work of monitoring 202 different patients with markedly elevated serum index for lipemia whereby serum samples were clear. We tried to clarify the cause of occurrence of these indices which were detected in the years 2006–2010 on Siemens Dimension analyzers.Materials and methods:
In samples with unusual lipemia index we measured the concentration of lipids (total cholesterol, triglycerides, HDL and LDL cholesterol, Lp(a), ApoA1, ApoB), total proteins and checked for possible interferents (rheumatoid factor, immunoglobulins). We performed serum protein and immuno- electrophoresis. We investigated the repeatability of unusual lipemia indices during the day and after different time periods and we compared them on four different analyzers (RXL Max, Vista, Hitachi 911 and former Olympus AU640).Results:
In 87% of 202 samples we found a monoclonal or biclonal peak in serum protein electrophoresis. Different types of paraproteins were confirmed with immunofixation electrophoresis. In the remaining 13%, polyclonal elevated concentrations of immunoglobulins were measured. Other parameters had no influence on appearing of these indices. The repeatability of indices was good during the first day of measurements (P values > 0.05) and markedly lower in the next days or after 3 and 12 months (P values < 0.05). The indices were elevated only on Dimension analyzers, but not on Hitachi and former Olympus analysers.Conclusion:
A markedly elevated lipemia index in a clear serum sample measured on Siemens analyzers Dimension indicates a high possibility for the presence of a paraprotein in the sample. 相似文献17.
Background
The preanalytical phase represents the major source of variability in laboratory diagnostics. Our aim was to assess to what extent underfilling of primary blood tubes may impact upon routine coagulation testing.Materials and methods:
Blood was drawn by syringe from 21 healthy volunteers and 6 patients on warfarin therapy, and immediately transferred into 3.6 mL vacuum tubes containing 3.2% sodium citrate (Terumo Europe N.V., Leuven, Belgium). All tubes were filled using standardized volumes of whole blood to produce scalar amounts of filling: 3.6 mL (i.e., 100%), 3.2 mL (89%), 2.8 mL (78%) and 2.4 mL (67%). Samples were mixed and centrifuged at 1300 × g for 10 min. The plasma was tested for prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FBG) on ACL TOP (Instrumentation Laboratory - IL, Milan, Italy), using IL reagents. A polynomial plot was derived for each parameter from interpolation of clotting values obtained with different percentages of filling, and these plots were compared with quality specifications (± 2.0 for PT, ± 2.3 for APTT and ± 4.8 for FBG) to calculate the minimal filling volume required to produce clinically acceptable results.Results:
The equations were (PF, Percentage of filling): PT (sec) = 3.375 × PF^2–6.255 × PF + 17.806 (r = 0.980); APTT (sec) = 8.925 × PF^2–23.578 × PF + 46.356 (r = 0.979); and FBG (mg/dL) = −311.5 × PF^2 + 422.1 × PF + 147.07 (r = 0.994). According to these equations, the minimum allowed thresholds of blood tubes filling were > 61% for PT, > 87% for APTT and > 71% for FBG.Conclusions:
Our results confirm that routine coagulation testing performed on underfilled tubes may generate biased and clinically misleading test results. This is particularly critical for APTT, wherein tubes filled at less than ∼90% generate unreliable data. The FBG and the PT seem more resistant to underfilling, clinical significant biases being observed only where blood tubes were filled at less than ∼60 and ∼70%, respectively. 相似文献18.
Lora Dukic Anja Jokic Josipa Kules Daria Pasalic 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2016,26(1):90-97
Introduction
The educational program for health care personnel is important for reducing preanalytical errors and improving quality of laboratory test results. The aim of our study was to assess the level of knowledge on preanalytical phase in population of biomedicine students through a cross-sectional survey.Materials and methods
A survey was sent to students on penultimate and final year of Faculty of Pharmacy and Biochemistry – study of medical biochemistry (FPB), Faculty of Veterinary Medicine (FVM) and School of Medicine (SM), University of Zagreb, Croatia, using the web tool SurveyMonkey. Survey was composed of demographics and 14 statements regarding the preanalytical phase of laboratory testing. Comparison of frequencies and proportions of correct answers was done with Fisher’s exact test and test of comparison of proportions, respectively.Results
Study included 135 participants, median age 24 (23-40) years. Students from FPB had higher proportion of correct answers (86%) compared to students from other biomedical faculties 62%, P < 0.001. Students from FPB were more conscious of the importance of specimen mixing (P = 0.027), prevalence of preanalytical errors (P = 0.001), impact of hemolysis (P = 0.032) and lipemia interferences (P = 0.010), proper choice of anticoagulants (P = 0.001), transport conditions for ammonia sample (P < 0.001) and order of draw during blood specimen collection (P < 0.001), in comparison with students from SM and FVM.Conclusions
Students from FPB are more conscious of the importance of preanalytical phase of testing in comparison with their colleagues from other biomedical faculties. No difference in knowledge between penultimate and final year of the same faculty was found.Key words: survey, education, preanalytical phase 相似文献19.
Matteo Vidali Vincenza Bianchi Marco Bagnati Nadia Atzeni Andrea Marco Bianchi Giorgio Bellomo 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(1):175-179
Introduction:
In this work we report on the possible effect of the medical therapy on CDT concentration in a chronic alcohol abuser, with known medical history (July 2007 – April 2012) and alcohol abuse confirmed by relatives.Case history:
At the end of 2007, patient displayed the following laboratory results: AST 137 U/L, ALT 120 U/L, GGT 434 U/L, MCV 101 fL and CDT 3.3%. On December 2007, after double coronary artery bypass surgery, he began a pharmacological treatment with amlodipine, perindopril, atorvastatin, isosorbide mononitrate, carvedilol, ticlopidine and pantoprazole. In the next months, until may 2011, the patient resumed alcohol abuse, as confirmed by relatives; however, CDT values were repeatedly found negative (0.8% and 1.1%) despite elevated transaminases and GGT, concurrent elevated ethyl glucuronide concentration (> 50 mg/L) and blood alcohol concentration (> 1 g/L). Alcohol consumption still continued despite increasing disulfiram doses ordered by an Alcohol Rehab Center. On May 2011, the patient was transferred to a private medical center where he currently lives.Conclusions:
This study suggests the possibility that a medical therapy including different drugs may hamper the identification of chronic alcohol abusers by CDT. 相似文献20.
Fatma Emel Ko?ak Mustafa Y?ntem ?zlem Yücel Mustafa ?ilo ?zlem Gen? Ayfer Meral 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(2):206-210