首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
Purpose: Several studies have demonstrated that physiological variables predict cycling endurance performance. However, it is still unclear whether the predictors will change over different performance durations. The aim of this study was to assess the correlations between physiological variables and cycling time trials with different durations. Methods: Twenty trained male cyclists (maximal oxygen uptake [VO2max] = 60.5 ± 5.6 mL/kg/min) performed 4 separate experimental trials during a 2-week period. Cyclists initially completed an incremental exercise test until volitional exhaustion followed by 3 maximal cycling time trials on separate days. Each time trial consisted of 3 different durations: 5 min, 20 min, and 60 min performed in a randomized order. Results: The main results showed that the physiological measures strongly correlated with long cycling performances rather than short and medium time trials. The time-trial mean power output was moderately high to highly correlated with peak power output and VO2max (r = .61–.87, r = .72–.89, respectively), and was moderately to highly correlated with the lactate threshold Dmax method and second ventilatory threshold (r = .52–.75, r = .55–.82, respectively). Conclusions: Therefore, trained cyclists should develop maximal aerobic power irrespective of the duration of time trial, as well as enhancements in metabolic thresholds for long-duration time trials.  相似文献   

2.
The aim of the present study was to examine the relationship between the performance heart rate during an ultra-endurance triathlon and the heart rate corresponding to several demarcation points measured during laboratory-based progressive cycle ergometry and treadmill running. Less than one month before an ultra-endurance triathlon, 21 well-trained ultra-endurance triathletes (mean +/- s: age 35 +/- 6 years, height 1.77 +/- 0.05 m, mass 74.0 +/- 6.9 kg, = 4.75 +/- 0.42 l x min(-1)) performed progressive exercise tests of cycle ergometry and treadmill running for the determination of peak oxygen uptake (VO2peak), heart rate corresponding to the first and second ventilatory thresholds, as well as the heart rate deflection point. Portable telemetry units recorded heart rate at 60 s increments throughout the ultra-endurance triathlon. Heart rate during the cycle and run phases of the ultra-endurance triathlon (148 +/- 9 and 143 +/- 13 beats x min(-1) respectively) were significantly (P < 0.05) less than the second ventilatory thresholds (160 +/- 13 and 165 +/- 14 beats x min(-1) respectively) and heart rate deflection points (170 +/- 13 and 179 +/- 9 beats x min(-1) respectively). However, mean heart rate during the cycle and run phases of the ultra-endurance triathlon were significantly related to (r = 0.76 and 0.66; P < 0.01), and not significantly different from, the first ventilatory thresholds (146 +/- 12 and 148 +/- 15 beats x min(-1) respectively). Furthermore, the difference between heart rate during the cycle phase of the ultra-endurance triathlon and heart rate at the first ventilatory threshold was related to marathon run time (r = 0.61; P < 0.01) and overall ultra-endurance triathlon time (r = 0.45; P < 0.05). The results suggest that triathletes perform the cycle and run phases of the ultra-endurance triathlon at an exercise intensity near their first ventilatory threshold.  相似文献   

3.
In this study, we assessed age-related changes in indoor 16.1-km cycling time-trial performance in 40 competitive male cyclists aged 25-63 years. Participants completed two tests: (1) a maximal ramped Kingcycle ergometer test, with maximal ramped minute power (RMPmax, W) recorded as the highest mean external power during any 60 s and maximal heart rate (HRmax, beats min(-1)) as the highest value during the test; and (2) an indoor Kingcycle 16.1-km time-trial with mean external power output (W), heart rate (beats min(-1)), and pedal cadence (rev min(-1)) recorded throughout the event. Results revealed age-related declines (P < 0.05) in absolute and relative time-trial external power output [(24 W (7.0%) per decade], heart rate [7 beats min(-1) (3.87%) per decade], and cadence [3 rev min(-1) (3.1%) per decade]. No relationships (P > 0.05) were observed for mean power output and heart rate recorded during the time-trial versus age when expressed relative to maximal ramped minute power and maximal heart rate respectively. Strong relationships (P < 0.05) were observed for maximal ramped minute power and time-trial power (r= 0.95) and for maximal heart rate and time-trial heart rate (r= 0.95). Our results show that indoor 16.1-km time-trial performance declines with age but relative exercise intensity (%RMPmax and %HRmax) does not change.  相似文献   

4.
It is common for the physiological working capacity of a triathlete when cycling and running to be assessed on two separate days. The aim of this study was to establish whether an incremental running test to exhaustion has a negative effect after a 5 h recovery from an incremental cycling test. Eight moderately trained triathletes (age, 26.2 +/- 3.4 years; body mass, 67.3 +/- 9.1 kg; VO2max when cycling, 59 +/- 13 ml x kg x min(-1); mean +/- s) completed an incremental running test 5 h after an incremental cycling test (fatigue) as well as an incremental running test without previous activity (control). Maximum running speed, maximal oxygen uptake (VO2max) and the lactate threshold were determined for each incremental running test and correlated with the average speed during a 5 km run, which was performed immediately after a 20 km cycling time-trial, as in a sprint triathlon. There were no significant differences in maximum running speed, VO2max or the lactate threshold in either incremental running test (control or fatigue). Furthermore, good agreement was found for each physiological variable in both the control and fatigue tests. For the fatigue test, there were significant correlations between the average speed during a 5 km run and both VO2max expressed in absolute terms (r = 0.83) and the lactate threshold (r = 0.88). However, maximum running speed correlated most strongly with the average speed during a 5 km run (r = 0.96). The results of this study indicate that, under controlled conditions, an incremental running test can be performed successfully 5 h after an incremental cycling test to exhaustion. Also, the maximum running speed achieved during an incremental running test is the variable that correlates most strongly with the average running speed during a 5 km run after a 20 km cycling time-trial in well-trained triathletes.  相似文献   

5.
The aim of this study was to establish a graded exercise test protocol for determining the peak physiological responses of female outrigger canoeists. Seventeen trained female outrigger canoeists completed two outrigger ergometer graded exercise test protocols in random order: (1) 25 W power output for 2 min increasing by 7.5 W every minute until exhaustion; and (2) 25 W power output for 2 min increasing by 15 W every 2 min to exhaustion. Heart rate and power output were recorded every 15 s. Expired air was collected continuously and sampled for analysis at 15-s intervals, while blood lactate concentration was measured immediately after and 3, 5, and 7 min after exercise. The peak physiological and performance variables examined included peak oxygen uptake (VO2peak), minute ventilation, tidal volume, ventilatory thresholds 1 and 2, respiratory rate, respiratory exchange ratio, heart rate, blood lactate concentration, power output, performance time, and time to VO2peak. There were no significant differences in peak physiological responses, ventilatory thresholds or performance variables between the two graded exercise test protocols. Despite no significant differences between protocols, due to the large limits of agreement evident between protocols for the peak physiological responses, it is recommended that the same protocol be used for all comparison testing to minimize intra-individual variability of results.  相似文献   

6.
The aim of this study was to determine the alterations in oxygen uptake kinetics following endurance training in previously trained athletes. Sixteen competitive cyclists completed 8 weeks of supervised endurance cycle training. Ventilatory threshold, maximal oxygen uptake (VO2max), oxygen uptake kinetics and simulated 40-km time-trial tests were performed three times over a 4-week period before training, and then after 4 and 8 weeks of training. The protocol for measuring oxygen uptake kinetics consisted of three square-wave increments from unloaded cycling to a power output of 78 W followed by a single increment from 78 to 156 W. No significant differences in any variables were observed over the pre-training period. The ventilatory threshold and VO2max increased, and the time for 40 km decreased (P < 0.05) with training. Shorter VO2 time constants and lower heart rates were observed during the protocol for measuring oxygen uptake kinetics (same absolute power output) post-training. These results indicate that oxygen uptake kinetics may be improved with endurance training in previously trained athletes.  相似文献   

7.
In this study, we assessed the performance of trained senior (n = 6) and veteran (n = 6) cyclists (mean age 28 years, s = 3 and 57 years, s = 4 respectively). Each competitor completed two cycling tests, a ramped peak aerobic test and an indoor 16.1-km time-trial. The tests were performed using a Kingcycle ergometer with the cyclists riding their own bicycle fitted with an SRM powermeter. Power output, heart rate, and gas exchange variables were recorded continuously and blood lactate concentration [HLa] was assessed 3 min after the peak ramped test and at 2.5-min intervals during the time-trial. Peak values for power output (RMP(max)), heart rate (HR(peak)), oxygen uptake (VO2(peak)), and ventilation (V(Epeak)) attained during the ramped test were higher in the senior group (P < 0.05), whereas [HLa](peak), RER(peak), V(E): VO2(peak), and economy(peak) were similar between groups (P > 0.05). Time-trial values (mean for duration of race) for power output (W(TT)), heart rate (HR(TT)), VO2 (VO(2TT)), and V(E) (V(ETT)) were higher in the seniors (P < 0.05), but [HLa](TT), RER(TT), V(ETT): VO2(TT), and economy(TT) were similar between the groups (P > 0.05). Time-trial exercise intensity, expressed as %RMP(max), %HR(peak), % VO2(peak), and % V(Epeak), was similar (P > 0.05) for seniors and veterans (W(TT): 81%, s = 2 vs. 78%, s = 8; HR(TT): 96%, s = 4 vs. 94%, s = 4; VO2(TT): 92%, s = 4 vs. 95%, s = 10; V(ETT): 89%, s = 8 vs. 85%, s = 8, respectively). Overall, seniors attained higher absolute values for power output, heart rate, VO2, and V(E) but not blood lactate concentration, respiratory exchange ratio (RER), V(E): VO2, and economy. Veterans did not accommodate age-related declines in time trial performance by maintaining higher relative exercise intensity.  相似文献   

8.
The aims of this study were to compare the physiological and anthropometric characteristics of successful mountain bikers and professional road cyclists and to re-examine the power-to-weight characteristics of internationally competitive mountain bikers. Internationally competitive cyclists (seven mountain bikers and seven road cyclists) completed the following tests: anthropometric measurements, an incremental cycle ergometer test and a 30 min laboratory time-trial. The mountain bikers were lighter (65.3+/-6.5 vs 74.7+/-3.8 kg, P= 0.01; mean +/- s) and leaner than the road cyclists (sum of seven skinfolds: 33.9+/-5.7 vs 44.5+/-10.8 mm, P = 0.04). The mountain bikers produced higher power outputs relative to body mass at maximal exercise (6.3+/-0.5 vs 5.8+/-0.3 W x kg(-1), P= 0.03), at the lactate threshold (5.2+/-0.6 vs 4.7+/-0.3 W x kg(-1), P= 0.048) and during the 30 min time-trial (5.5+/-0.5 vs 4.9+/-0.3 W x kg(-1), P = 0.02). Similarly, peak oxygen uptake relative tobody mass was higher in the mountain bikers (78.3+/-4.4 vs 73.0+/-3.4 ml x kg(-1) x min(-1), P = 0.03). The results indicate that high power-to-weight characteristics are important for success in mountain biking. The mountain bikers possessed similar anthropometric and physiological characteristics to previously studied road cycling uphill specialists.  相似文献   

9.
Graded exercise tests are commonly used to assess peak physiological capacities of athletes. However, unlike time trials, these tests do not provide performance information. The aim of this study was to examine the peak physiological responses of female outrigger canoeists to a 1000-m ergometer time trial and compare the time-trial performance to two graded exercise tests performed at increments of 7.5 W each minute and 15 W each two minutes respectively. 17 trained female outrigger canoeists completed the time trial on an outrigger canoe ergometer with heart rate (HR), stroke rate, power output, and oxygen consumption (VO2) determined every 15 s. The mean (+/- s) time-trial time was 359 +/- 33 s, with a mean power output of 65 +/- 16 W and mean stroke rate of 56 +/- 4 strokes min(-1). Mean values for peak VO2, peak heart rate, and mean heart rate were 3.17 +/- 0.67 litres min(-1), 177 +/- 11 beats min(-1), and 164 +/- 12 beats min(-1) respectively. Compared with the graded exercise tests, the time-trial elicited similar values for peak heart rate, peak power output, peak blood lactate concentration, and peak VO2. As a time trial is sport-specific and can simultaneously quantify sprint performance and peak physiological responses in outrigger canoeing, it is suggested that a time trial be used by coaches for crew selection as it doubles as a reliable performance measure and a protocol for monitoring peak aerobic capacity of female outrigger canoeists.  相似文献   

10.
Physiological correlates to off-road cycling performance   总被引:1,自引:1,他引:0  
The aim of this study was to examine the relationships between maximal and submaximal tests for aerobic fitness and performance in an off-road cross-country circuit race. Thirteen competitive off-road male cyclists participated in the study. Peak oxygen uptake (VO2peak), peak power output, and lactate thresholds corresponding to 1 mmol x l(-1) above baseline (lactate threshold) and to 4 mmol x l(-1) (onset of blood lactate accumulation) were measured during an incremental cycling test. Race time and final ranking within the same group of cyclists were determined during a cross-country off-road competition. All correlations between the measured parameters of aerobic fitness and off-road cycling performance were significant, particularly between race time and physiological parameters scaled to body mass0.79 (r = -0.68 to -0.94; P < 0.05) and between final ranking and physiological parameters expressed relative to body mass0.79 (r = -0.81 to - 0.96; P < 0.001). Moreover, there was a large difference (effect sizes = 1.12-1.70) in all measured parameters of aerobic fitness between the group of six cyclists with a race time above the median and the group of six cyclists with a race time below the median (P < 0.05). In conclusion, the results of this study provide empirical support to the widespread use of these maximal (VO2peak, peak power output) and submaximal (lactate thresholds) parameters of aerobic fitness in the physiological assessments of off-road cyclists. Furthermore, our results suggest body size should be taken into account when evaluating such athletes.  相似文献   

11.
Abstract

The aims of this study were to compare the physiological demands of laboratory- and road-based time-trial cycling and to examine the importance of body position during laboratory cycling. Nine male competitive but non-elite cyclists completed two 40.23-km time-trials on an air-braked ergometer (Kingcycle) in the laboratory and one 40.23-km time-trial (RD) on a local road course. One laboratory time-trial was conducted in an aerodynamic position (AP), while the second was conducted in an upright position (UP). Mean performance speed was significantly higher during laboratory trials (UP and AP) compared with the RD trial (P < 0.001). Although there was no difference in power output between the RD and UP trials (P > 0.05), power output was significantly lower during the AP trial than during both the RD (P = 0.013) and UP trials (P = 0.003). Similar correlations were found between AP power output and RD power output (r = 0.85, P = 0.003) and between UP power output and RD power output (r = 0.87, P = 0.003). Despite a significantly lower power output in the laboratory AP condition, these results suggest that body position does not affect the ecological validity of laboratory-based time-trial cycling.  相似文献   

12.
It is perceived that, during the triathlon or duathlon, cycling with a steep (> 76 degrees) rather than a shallow (< 76 degrees ) frame geometry might attenuate the fatigue associated with progression from the cycle to run disciplines and improve subsequent 10-km running performance. This is based on anecdotal testimony from athletes purporting to have experienced improved performance; no empirical evidence exists. To evaluate this view, eight male triathletes completed a counterbalanced, 40-km cycle ride at two frame geometries (73 degrees and 81 degrees) at approximately 70% VO2peak. Immediately after completion of each 40-km cycle, a self-paced 10-km treadmill time trial was undertaken, during which physiological, kinematic and performance variables were measured. The 10-km run performance (mean +/- s: 42:55 +/- 4:19 vs 46:15 +/- 4:52 min; P< 0.01) and combined cycle and run performance (1:45:49 +/- 5:45 vs 1:50:33 +/- 6:08; P< 0.001) were faster in the 81 degrees than the 73 degrees condition. Improvements in performance were most prominent during the first 5 km of the run (21:41 +/- 2:15 vs 24:15 +/- 2:31 min in the 81 degrees and 73 degrees conditions respectively). These improvements were not evident during the second 5 km of the run. No differences in physiological variables were noted, although heart rate, stride length and stride frequency were increased during the 81 degrees condition (P < 0.05). Modifying frame geometry from a seat tube angle of 73 degrees to 81 degrees improves 10-km running and combined cycle plus run performance. These improvements in performance might relate to alterations during the cycling phase, which minimizes the 'residual effect' of this (i.e. the adverse changes in substrate availability, thermoregulatory, cardiovascular and biomechanical factors felt immediately after transition from cycling to running) and attenuates negative changes in physiological and kinematic responses during the 10-km run.  相似文献   

13.
The aim of this study was to compare accumulated oxygen deficit data derived using two different exercise protocols with the aim of producing a less time-consuming test specifically for use with athletes. Six road and four track male endurance cyclists performed two series of cycle ergometer tests. The first series involved five 10 min sub-maximal cycle exercise bouts, a VO2peak test and a 115% VO2peak test. Data from these tests were used to estimate the accumulated oxygen deficit according to the calculations of Medb? et al. (1988). In the second series of tests, participants performed a 15 min incremental cycle ergometer test followed, 2 min later, by a 2 min variable resistance test in which they completed as much work as possible while pedalling at a constant rate. Analysis revealed that the accumulated oxygen deficit calculated from the first series of tests was higher (P < 0.02) than that calculated from the second series: 52.3 +/- 11.7 and 43.9 +/- 6.4 ml x kg(-1), respectively (mean +/- s). Other significant differences between the two protocols were observed for VO2peak, total work and maximal heart rate; all were higher during the modified protocol (P < 0.01 and P < 0.02, respectively). Oxygen kinetics were also significantly faster during the modified 2 min maximal test. We conclude that the difference in accumulated oxygen deficit between protocols was probably due to a reduced oxygen uptake, possibly caused by a slower oxygen on-response during the 115% VO2peak test in the first series, and VO2-power output regression differences caused by an elevated VO2 during the early stages of the second series.  相似文献   

14.
It is perceived that, during the triathlon or duathlon, cycling with a steep (>76°) rather than a shallow (?76°) frame geometry might attenuate the fatigue associated with progression from the cycle to run disciplines and improve subsequent 10-km running performance. This is based on anecdotal testimony from athletes purporting to have experienced improved performance; no empirical evidence exists. To evaluate this view, eight male triathletes completed a counterbalanced, 40-km cycle ride at two frame geometries (73° and 81°) at ~70% VO 2peak . Immediately after completion of each 40-km cycle, a self-paced 10-km treadmill time trial was undertaken, during which physiological, kinematic and performance variables were measured. The 10-km run performance (mean - s : 42:55 - 4:19 vs 46:15 - 4:52 min; P ? 0.01) and combined cycle and run performance (1:45:49 - 5:45 vs 1:50:33 - 6:08; P ? 0.001) were faster in the 81° than the 73° condition. Improvements in performance were most prominent during the first 5 km of the run (21:41 - 2:15 vs 24:15 - 2:31 min in the 81° and 73° conditions respectively). These improvements were not evident during the second 5 km of the run. No differences in physiological variables were noted, although heart rate, stride length and stride frequency were increased during the 81° condition ( P ? 0.05). Modifying frame geometry from a seat tube angle of 73° to 81° improves 10-km running and combined cycle plus run performance. These improvements in performance might relate to alterations during the cycling phase, which minimizes the 'residual effect' of this (i.e. the adverse changes in substrate availability, thermoregulatory, cardiovascular and biomechanical factors felt immediately after transition from cycling to running) and attenuates negative changes in physiological and kinematic responses during the 10-km run.  相似文献   

15.
Diurnal variation in cycling performance: influence of warm-up   总被引:2,自引:0,他引:2  
We examined the effects of time of day on a cycling time trial with and without a prolonged warm-up, among cyclists who tended towards being high in "morningness". Eight male cyclists (mean +/- s: age = 24.9 +/- 3.5 years, peak power output = 319 +/- 34 W, chronotype = 39 +/- 6 units) completed a 16.1-km time trial without a substantial warm-up at both 07:30 and 17:30 h. The time trial was also completed at both times of day after a 25-min warm-up at 60% of peak power. Power output, heart rate, intra-aural temperature and category ratings of perceived exertion (CR-10) were measured throughout the time trial. Post-test blood lactate concentration was also recorded. Warm-up generally improved time trial performance at both times of day (95% CI for improvement = 0 to 30 s), but mean cycling time was still significantly slower at 07:30 h than at 17:30 h after the warm-up (95% CI for difference = 33 to 66 s). Intra-aural temperature increased as the time trial progressed (P < 0.0005) and was significantly higher throughout the time trials at 17:30 h (P = 0.001), irrespective of whether the cyclists performed a warm-up or not. Blood lactate concentration after the time trial was lowest at 07:30 h without a warm-up (P = 0.02). No effects of time of day or warm-up were found for CR-10 or heart rate responses during the time trial. These results suggest that 16.1-km cycling performance is worse in the morning than in the afternoon, even with athletes who tend towards 'morningness', and who perform a vigorous 25-min warm-up. Diurnal variation in cycling performance is, therefore, relatively robust to some external and behavioural factors.  相似文献   

16.
The aims of this study were to compare the physiological demands of laboratory- and road-based time-trial cycling and to examine the importance of body position during laboratory cycling. Nine male competitive but non-elite cyclists completed two 40.23-km time-trials on an air-braked ergometer (Kingcycle) in the laboratory and one 40.23-km time-trial (RD) on a local road course. One laboratory time-trial was conducted in an aerodynamic position (AP), while the second was conducted in an upright position (UP). Mean performance speed was significantly higher during laboratory trials (UP and AP) compared with the RD trial (P < 0.001). Although there was no difference in power output between the RD and UP trials (P > 0.05), power output was significantly lower during the AP trial than during both the RD (P = 0.013) and UP trials (P = 0.003). Similar correlations were found between AP power output and RD power output (r = 0.85, P = 0.003) and between UP power output and RD power output (r = 0.87, P = 0.003). Despite a significantly lower power output in the laboratory AP condition, these results suggest that body position does not affect the ecological validity of laboratory-based time-trial cycling.  相似文献   

17.
The power output achieved at peak oxygen consumption (VO2peak) and the time this power can be maintained (i.e., Tmax) have been used in prescribing high-intensity interval training. In this context, the present study examined temporal aspects of the VO2 response to exercise at the cycling power that output well trained cyclists achieve their VO2peak (i.e., Pmax). Following a progressive exercise test to determine VO2peak, 43 well trained male cyclists (M age = 25 years, SD = 6; M mass = 75 kg, SD = 7; M VO2peak = 64.8 ml x kg(-1) x min(-1), SD = 5.2) performed two Tmax tests 1 week apart. Values expressed for each participant are means and standard deviations of these two tests. Participants achieved a mean VO2peak during the Tmax test after 176 s (SD = 40; M = 74% of Tmax, SD = 12) and maintained it for 66 s (SD = 39; M = 26% of Tmax, SD = 12). Additionally, they obtained mean 95% of VO2peak after 147 s (SD = 31; M = 62% of Tmax, SD = 8) and maintained it for 95 s (SD = 38; M = 38% of Tmax, SD = 8). These results suggest that 60-70% of Tmax is an appropriate exercise duration for a population of well trained cyclists to attain VO2peak during exercise at Pmax. However, due to intraparticipant variability in the temporal aspects of the VO2 response to exercise at Pmax, future research is needed to examine whether individual high-intensity interval training programs for well trained endurance athletes might best be prescribed according to an athlete's individual VO2 response to exercise at Pmax.  相似文献   

18.
The respiratory time and flow profile at volitional exercise termination   总被引:1,自引:0,他引:1  
In this study, we examine the effect of exercise on the time and flow characteristics of the respiratory cycle profile at the point of volitional exercise termination. Eight males (mean age 29 years, s = 10; body mass 74 kg, s = 7; height 1.75 m, s = 0.04) undertook a cycle test to volitional exhaustion on a cycle ergometer, which allowed peak oxygen uptake (VO(2peak)) to be measured (mean 51 ml x kg(-1) x min(-1), s = 7). At a later date, two sub-maximal tests to volitional exhaustion were completed in a random order at 76% (s = 6) and 86% VO(2peak) (s = 7). As expected, the magnitude of the respiratory flow and time characteristics varied with the three exercise intensities, as did the point of exercise termination and terminal ventilation rates, which varied from 7 to 27 min and 112 to 132 litres x min(-1) respectively. More importantly, however, at exercise termination some of the characteristics were similar, particularly the breathing frequency (at termination 49 breaths x min(-1)), the ratio between inspiration and total breath time (0.5), and the later occurrence of peak inspiratory flow (0.24-0.48 s). The coincident unity of these time and flow profile characteristics at exercise termination illustrates how the integration of timing and flow during breathing influence exercise capacity in non-elite athletes.  相似文献   

19.
The aim of this study was to assess the relationship between several commonly used aerobic and anaerobic cycle ergometer tests and performance during a treadmill cycling hill climb. Eight competitive cyclists (age 27+/-7 years; body mass 73.2+/-5.2 kg; height 177+/-6 cm; mean +/- s) completed six tests in random order: a lactate minimum test; a Wingate anaerobic power test; and two 6-km climbs at 6% and two 1-km climbs at 12% gradient performed on a motorized treadmill. The mean times and power outputs for the 6-km and 1-km climbs were 16:30+/-1:08 min: s and 330+/-17.8 W, and 4:19+/-0:27 min: s and 411+/-24.4 W, respectively. The best individual predictor of 6-km and 1-km performance times was the time for the corresponding climb at the other distance (r = 0.97). The next strongest predictor of both hill climb performances was the average power produced during the Wingate test divided by body mass. Stepwise regression analysis showed that the two variables contributing most to the prediction equation for both climbs were the Wingate average power per unit of body mass and maximal aerobic power divided by total mass (rider + bike), which together accounted for 92 and 96% of the variability in the 6-km and 1-km climbs. In conclusion, among competitive cyclists, the Wingate average power per unit of body mass was the best single predictor of simulated cycling hill climb performance at the distance and gradient used.  相似文献   

20.
Abstract

The aim of this study was to establish a graded exercise test protocol for determining the peak physiological responses of female outrigger canoeists. Seventeen trained female outrigger canoeists completed two outrigger ergometer graded exercise test protocols in random order: (1) 25 W power output for 2 min increasing by 7.5 W every minute until exhaustion; and (2) 25 W power output for 2 min increasing by 15 W every 2 min to exhaustion. Heart rate and power output were recorded every 15 s. Expired air was collected continuously and sampled for analysis at 15-s intervals, while blood lactate concentration was measured immediately after and 3, 5, and 7 min after exercise. The peak physiological and performance variables examined included peak oxygen uptake ([Vdot]O2peak), minute ventilation, tidal volume, ventilatory thresholds 1 and 2, respiratory rate, respiratory exchange ratio, heart rate, blood lactate concentration, power output, performance time, and time to [Vdot]O2peak. There were no significant differences in peak physiological responses, ventilatory thresholds or performance variables between the two graded exercise test protocols. Despite no significant differences between protocols, due to the large limits of agreement evident between protocols for the peak physiological responses, it is recommended that the same protocol be used for all comparison testing to minimize intra-individual variability of results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号