首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 42 毫秒
1.
Despite the increasing popularity of futsal, there is little information on performance characteristics of players. We aimed to determine the validity and reliability of a futsal shooting test and to evaluate and compare performance characteristics of three futsal playing levels. Twenty-four males (n = 8 elite, n = 8 semi-elite, n = 8 social) completed two trials to examine the reliability of the Massey Futsal Shooting Test (MFST) and to compare various fitness characteristics between groups. MFST time taken (P = 0.010), shot speed (P < 0.001) and points scored per shot (P < 0.001) were better for elite relative to social players. Test–retest reliability was acceptable for all groups, but it was most repeatable in elite players. Loughborough Soccer Passing Test performance was better in elite relative to social players (P = 0.004). There were no differences in countermovement-jump height between groups. Elite players ran faster over 5 m than both semi-elite (P = 0.043) and social (P = 0.002) and faster than the social players through 10 m (P = 0.028) and 20 m (P = 0.026). Distance covered in the Futsal Intermittent Endurance Test was higher in elite relative to semi-elite (P = 0.005) and social (P < 0.001) groups. The MFST is a valid and reliable protocol to assess futsal shooting-skill performance; elite players have superior shooting and passing skill and have greater sprinting and intermittent-running ability.  相似文献   

2.
Abstract

Thirty-eight competitive cross-country skiers were divided into three groups to assess the reliability and validity of a new double poling ergometer. Group A (n = 22) performed two maximal 60-s tests, Group B (n = 8) repeated peak oxygen uptake tests on the double poling ergometer, and Group C (n = 8) performed a maximal 6-min test on the double poling ergometer and a double poling time-trial on snow. The correlation between the power calculated at the flywheel and the power applied at the base of the poles was r = 0.99 (P < 0.05). The power at the poles was 50 – 70% higher than that at the flywheel. There was a high test – retest reliability in the two 60-s power output tests (coefficient of variation = 3.0%) and no significant difference in peak oxygen uptake in the two 6-min all-out tests (coefficient of variation = 2.4%). There was a strong correlation between the absolute (W) and relative power (W · kg?1) output in the 6-min double poling ergometer test and the double poling performance on snow (r = 0.86 and 0.89 respectively; both P < 0.05). In conclusion, our results show that the double poling ergometer has both high reliability and validity. However, the power calculated at the flywheel underestimated the total power produced and needs to be corrected for in ergonomic estimations.  相似文献   

3.
Abstract

The aim of this study was to assess the validity (Study 1) and reliability (Study 2) of a novel intermittent running test (Carminatti's test) for physiological assessment of soccer players. In Study 1, 28 players performed Carminatti's test, a repeated sprint ability test, and an intermittent treadmill test. In Study 2, 24 players performed Carminatti's test twice within 72 h to determine test–retest reliability. Carminatti's test required the participants to complete repeated bouts of 5 × 12 s shuttle running at progressively faster speeds until volitional exhaustion. The 12 s bouts were separated by 6 s recovery periods, making each stage 90 s in duration. The initial running distance was set at 15 m and was increased by 1 m at each stage (90 s). The repeated sprint ability test required the participants to perform 7 × 34.2 m maximal effort sprints separated by 25 s recovery. During the intermittent treadmill test, the initial velocity of 9.0 km · h?1 was increased by 1.2 km · h?1 every 3 min until volitional exhaustion. No significant difference (P > 0.05) was observed between Carminatti's test peak running velocity and speed at VO2max (v-VO2max). Peak running velocity in Carminatti's test was strongly correlated with v-VO2max (r = 0.74, P < 0.01), and highly associated with velocity at the onset of blood lactate accumulation (r = 0.63, P < 0.01). Mean sprint time was strongly associated with peak running velocity in Carminatti's test (r = ?0.71, P < 0.01). The intraclass correlation was 0.94 with a coefficient of variation of 1.4%. In conclusion, Carminatti's test appears to be avalid and reliable measure of physical fitness and of the ability to perform intermittent high-intensity exercise in soccer players.  相似文献   

4.
The current study aimed to assess the validity and test–retest reliability of a linear position transducer when compared to a force plate through a counter-movement jump in female participants. Twenty-seven female recreational athletes (19 ± 2 years) performed three counter-movement jumps simultaneously using the linear position transducer and force plate for validity. In addition, 11 elite female athletes (23 ± 6 years) performed 3 counter-movement jumps with the linear position transducer on three separate days for test–retest reliability. Pearson correlations for jump height between the devices were at a high level (= .90), with the linear position transducer overestimating jump height by 7.0 ± 2.8 cm. The reliability measured by the linear position transducer resulted in a mean intraclass correlation of .70 for jump height, .90 for peak velocity, and .91 for mean velocity. The linear position transducer was reliable for measuring counter-movement jumps in elite female athletes; however, caution should be taken for one-off jump measures as it may over-estimate jump height.  相似文献   

5.
Abstract

The aim of the present study was to examine the relationship between intensities of exercise during match-play of elite-standard soccer referees with those of the players from the same match. Match analysis data were collected (Prozone® Leeds, UK) for 18 elite-standard soccer referees (age 26–49 years) on FA Premier League matches during the 2008/09 English FA Premier League season (236 observations). Running categories for referees and players were as follows: total distance covered (m); high-speed running distance (speed >19.8 km · h?1); and sprinting distance (speed >25.2 km · h?1). Analysis of the distance–time regression coefficients revealed no differences between the referees' and players' within-match rates of change for total distance covered (?0.594 ± 0.394 vs. ?0.713 ± 0.269 m · min?1; P = 0.104), high-speed running (?0.039 ± 0.077 vs. ?0.059 ± 0.030 m · min?1; P = 0.199), and sprinting (?0.003 ± 0.039 vs. ?0.021 ± 0.017 m · min?1; P = 0.114). In addition, there were no differences between across-season rates of change for total distance (–26.756 ± 40.434 vs. ?20.031 ± 25.502 m per match day; P = 0.439) and sprinting (–9.662 ± 7.564 vs. ?8.589 ± 4.351 m per match day; P = 0.542). These results show that elite-standard soccer referees' intensities of exercise during match-play are interrelated with those of the players and thus demonstrate that referees are able to keep pace with the players during FA Premier League matches.  相似文献   

6.
This study investigated the effect cadence has on the estimation of critical power (CP) and the finite work capacity (W?) during the 3-minute all-out cycling test. Ten participants completed 8 tests: 1) an incremental test to calculate gas exchange threshold (GET), maximal aerobic power (MAP) and peak oxygen uptake (V?O2peak), 2–4) three time-to-exhaustion tests at 80, 100 and 105% MAP to calculate CP and W?, 5–7) four 3-minute all-out tests to calculate end power (EP) and work done above EP (WEP) using cadences ranging from preferred ?5 to preferred +10 rev·min?1 to set the fixed resistance. Significant differences were seen between CP and EP-preferred (267.5 ± 22.6 W vs. 296.6 ± 26.1 W, < 0.001), CP and EP?5 (267.5 ± 22.6 W vs. 303.6 ± 24.0 W, < 0.001) and between CP and EP+5 (267.5 ± 22.6 W vs. 290.0 ± 28.0 W, = 0.002). No significant differences were seen between CP and EP+10 (267.5 ± 22.6 W vs. 278.1 ± 30.9 W, = 0.331). Significant differences were seen between W? and WEP at all tested fixed resistances. EP is reduced when cycling at higher than preferred cadences, providing better estimates of CP.  相似文献   

7.
Abstract

The International Physical Activity Questionnaire (IPAQ) has been widely used to assess physical activity in healthy populations. The present study compared physical activity assessed by the long, self-administrated version of the International Physical Activity Questionnaire with physical activity assessed by accelerometry in patients with fibromyalgia. A total of 99 (five men) participants with fibromyalgia completed the International Physical Activity Questionnaire and wore an accelerometer for nine consecutive days. We analysed the correlations of physical activity expressed as min · day?1 of light, moderate, vigorous, and moderate to vigorous (MVPA) intensity, as well as time spent sitting, by the International Physical Activity Questionnaire and accelerometry by Spearman correlations. Bland and Altman plots were performed to verify the agreements between both instruments. The results showed weak yet significant correlations (Rs = 0.15–0.39, all P < 0.05) in all physical activity intensities between the two instruments, except for sedentary time. The highest correlations were observed for physical activity at home or in garden (Rs = 0.297, P < 0.01). The results suggest that the long self-administrated International Physical Activity Questionnaire is a questionable instrument to assess physical activity in patients with fibromyalgia. Therefore, physical activity measurement in fibromyalgia patients should not be limited solely to self-reported measures.  相似文献   

8.
Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the relationship between finger flexor all-out test scores and climbing ability. Methods: To determine the effect of AF, 22 male climbers performed 2 maximal strength and all-out tests with AF (shoulder and elbow flexed at 90°) and without AF (shoulder flexed at 180° and elbow fully extended). To determine reliability, 9 male climbers completed 2 maximal strength tests with and without AF and an all-out and intermittent test without AF. Results: The maximal strength test without AF more strongly determined climbing ability than the test with AF (r2 = .48 and r2 = .42 for sport climbing; r2 = .66 and r2 = .42 for bouldering, respectively). Force and time variables were highly reliable; the rate of force development and fatigue index had moderate and low reliability. The maximal strength test with AF provided slightly higher reliability than without AF (intraclass correlation coefficient [ICC] = 0.94, ICC = 0.88, respectively). However, smaller maximal forces were achieved during AF (484 ± 112 N) than without AF (546 ± 132 N). All-out test average force had sufficiently high reliability (ICC = 0.92) and a relationship to sport climbing (r2 = .42) and bouldering ability (r2 = .58). Conclusion: Finger strength and endurance measurements provided sufficient construct validity evidence and high reliability for time and force parameters. Arm fixation provides more reliable results; however, the position without AF is recommended as it is more related to climbing ability.  相似文献   

9.
Reproducibility of frequency content from surface electromyography (sEMG) signals has not been assessed and it is unknown if incremental load testing design could affect sEMG in cycling. The goals of this study were to assess the reproducibility of measures from sEMG frequency content between sessions and to compare these frequency components between a ramp and a step incremental cycling test. Eighteen cyclists performed four incremental load cycling tests to exhaustion. Two tests were performed using a step increment (load started at 100 W for 3 min followed by increments of 30 W every 3 min) and two were performed using a ramp increment (load started at 100 W for 1 min followed by increments of 30 W·min?1). sEMG was monitored bilaterally for the rectus femoris and vastus lateralis throughout the tests and converted into overall activation (whole signal bandwidth), high- and low-frequency contents. The reproducibility of the frequency content ranged from none to strong (ICC = 0.07–0.90). Vastus lateralis activation was larger at the step compared to the ramp test (P < 0.01), without differences for rectus femoris (P = 0.22–0.91) and for the high-frequency (P = 0.28–0.95) and low-frequency contents (P = 0.13–0.94). sEMG from vastus lateralis and rectus femoris presented none to strong reproducibility. Vastus lateralis is more activated in step test design.  相似文献   

10.
We examined psychometric properties of a Modified Physical Activity Questionnaire for Children (MPAQ-C). Thirty-two parents (Study 1), 40 students (6–9 years) and one of each student’s parents (Study 2), and 625 parents (Study 3) completed the MPAQ-C. The MPAQ-C (six items) measured children’s physical activity (PA) after school, and during evenings and weekends for 7 days. Test–retest reliability (Study 1) and convergent validity (Study 2) were measured. Factor validity of the MPAQ-C (Study 3) was examined using confirmatory factor analysis. A single-factor model of the MPAQ-C fit the data well (χ2 (9) = 42.78, < .001; comparative fit index[CFI] = .977; non-normed fit index [NNFI] = .962; root mean square error of approximation [RMSEA] = .079 [90% confidence interval {CI} = .057 to .11]), with good test–retest reliability, composite reliability (.80) and convergent validity. The factor loadings of MPAQ-C were invariant across fathers/mothers (Δχ2 (6) = 3.44, > .05). The MPAQ-C is a suitable parent proxy for measuring young Chinese children’s PA.  相似文献   

11.
Abstract

Micro-sensors were used to quantify macro kinematics of classical cross-country skiing techniques and measure cycle rates and cycle lengths during on-snow training. Data were collected from seven national level participants skiing at two submaximal intensities while wearing a micro-sensor unit (MinimaxX?). Algorithms were developed identifying double poling (DP), diagonal striding (DS), kick-double poling (KDP), tucking (Tuck), and turning (Turn). Technique duration (T-time), cycle rates, and cycle counts were compared to video-derived data to assess system accuracy. There was good reliability between micro-sensor and video calculated cycle rates for DP, DS, and KDP, with small mean differences (Mdiff% = ?0.2 ± 3.2, ?1.5 ± 2.2 and ?1.4 ± 6.2) and trivial to small effect sizes (ES = 0.20, 0.30 and 0.13). Very strong correlations were observed for DP, DS, and KDP for T-time (r = 0.87–0.99) and cycle count (r = 0.87–0.99), while mean values were under-reported by the micro-sensor. Incorrect Turn detection was a major factor in technique cycle misclassification. Data presented highlight the potential of automated ski technique classification in cross-country skiing research. With further refinement, this approach will allow many applied questions associated with pacing, fatigue, technique selection and power output during training and competition to be answered.  相似文献   

12.
This study examined the validity and reliability of a 30-second running sprint test using two non-motorized treadmills compared to the established Wingate Anaerobic Test. Twenty-four participants completed three sessions in a randomized order on a: (1) manual mode treadmill (Woodway); (2) specialized interval training treadmill (HiTrainer); and (3) Wingate cycle ergometer. In a subset of 15 participants, 2 additional sessions were completed on both treadmills to establish the test–retest reliability. Peak (Woodway: r = .68; HiTrainer: r = .58; p < .003), average (Woodway: r = .82; HiTrainer: r = .72, p < .001), and minimum (Woodway: r = .64; HiTrainer: r = .42, p < .043) speed indices were moderately to very strongly correlated with corresponding Wingate Anaerobic Test outputs and had excellent test–retest reliability (all intraclass correlation coefficients > .75). Fatigue index during the Wingate Anaerobic Test (51.20 ± 7.14%) was moderately correlated with the Woodway (32.9 ± 10.9%, r = .55, p = .005) only. This 30-second running sprint test may be a valid and reliable mode-specific alternative to the Wingate Anaerobic Test.  相似文献   

13.
Purpose

Dog owners represent 40% of the population, a promising audience to increase population levels of physical activity. The purpose of this study was to develop and test the psychometric properties of a new instrument to assess social-cognitive theory constructs related to dog walking.

Method

Dog owners (N = 431) completed the Dogs and WalkinG Survey (DAWGS). Survey items assessed dog-walking behaviors and self-efficacy, social support, outcome expectations, and outcome expectancies for dog walking. Test–retest reliability was assessed among 252 (58%) survey respondents who completed the survey twice. Factorial validity and factorial invariance by age and walking level were tested using confirmatory factor analysis.

Results

DAWGS items demonstrated moderate test–retest reliability (ρ = .39–.79; k = .41–.89). Acceptable model fit was found for all subscales. All subscales were invariant by age and walking level, except self-efficacy, which showed mixed evidence of invariance.

Conclusions

The DAWGS is a psychometrically sound instrument for examining individual and interpersonal correlates of dog walking.  相似文献   

14.
This investigation sets out to assess the effect of five different models of mountain bike tyre on rolling performance over hard-pack mud. Independent characteristics included total weight, volume, tread surface area and tread depth. One male cyclist performed multiple (30) trials of a deceleration field test to assess reliability. Further tests performed on a separate occasion included multiple (15) trials of the deceleration test and six fixed power output hill climb tests for each tyre. The deceleration test proved to be reliable as a means of assessing rolling performance via differences in initial and final speed (coefficient of variation (CV) = 4.52%). Overall differences between tyre performance for both deceleration test (P = 0.014) and hill climb (P = 0.032) were found, enabling significant (P < 0.0001 and P = 0.049) models to be generated, allowing tyre performance prediction based on tyre characteristics. The ideal tyre for rolling and climbing performance on hard-pack surfaces would be to decrease tyre weight by way of reductions in tread surface area and tread depth while keeping volume high.  相似文献   

15.
Abstract

Graded exercise tests are commonly used to assess peak physiological capacities of athletes. However, unlike time trials, these tests do not provide performance information. The aim of this study was to examine the peak physiological responses of female outrigger canoeists to a 1000-m ergometer time trial and compare the time-trial performance to two graded exercise tests performed at increments of 7.5 W each minute and 15 W each two minutes respectively. 17 trained female outrigger canoeists completed the time trial on an outrigger canoe ergometer with heart rate (HR), stroke rate, power output, and oxygen consumption ([Vdot]O2) determined every 15 s. The mean (± s) time-trial time was 359 ± 33 s, with a mean power output of 65 ± 16 W and mean stroke rate of 56 ± 4 strokes · min?1. Mean values for peak [Vdot]O2, peak heart rate, and mean heart rate were 3.17 ± 0.67 litres · min?1, 177 ± 11 beats · min?1, and 164 ± 12 beats · min?1 respectively. Compared with the graded exercise tests, the time-trial elicited similar values for peak heart rate, peak power output, peak blood lactate concentration, and peak [Vdot]O2. As a time trial is sport-specific and can simultaneously quantify sprint performance and peak physiological responses in outrigger canoeing, it is suggested that a time trial be used by coaches for crew selection as it doubles as a reliable performance measure and a protocol for monitoring peak aerobic capacity of female outrigger canoeists.  相似文献   

16.
ABSTRACT

The aim of the present study was to determine the factors affecting sports involvement in a school-based adolescent population. The cross-sectional cohort study assessed anthropometry, physical capacities and motor competence in 501 boys (aged 10–16 y), from junior (1012 y) and senior (1316 y) cohorts. Sports participation data was collected from junior participants. Multivariate analysis of covariance revealed moderate maturity, anthropometry, physical capacity and motor competence differences between sports in the senior cohort (F = 2.616, p < 0.001, η2 = .08), but not in the junior cohort. Furthermore, differences in physical fitness were revealed between playing levels (F = 2.616, p < 0.001, η2 = .08), with a discriminant analysis correctly classifying 73% of participants using aerobic fitness and vertical jump measures. Representative level participants engaged in more structured training and commenced organised competition at a later age (F = 4.332, p < 0.001, η2 = .21). This study’s findings are twofold: 1) physical and motor competence profiles differ more between sports with increasing age, and 2) participants at a higher level of competition report delayed engagement in their main sport. As a result, schools may be the ideal environment in which to provide children and adolescents with the opportunity to sample different sports.  相似文献   

17.
Abstract

This study determined the precision of pencil and fan beam dual-energy X-ray absorptiometry (DXA) devices for assessing body composition in professional Australian Football players. Thirty-six professional Australian Football players, in two groups (fan DXA, N = 22; pencil DXA, N = 25), underwent two consecutive DXA scans. A whole body phantom with known values for fat mass, bone mineral content and fat-free soft tissue mass was also used to validate each DXA device. Additionally, the criterion phantom was scanned 20 times by each DXA to assess reliability. Test–retest reliability of DXA anthropometric measures were derived from repeated fan and pencil DXA scans. Fat-free soft tissue mass and bone mineral content from both DXA units showed strong correlations with, and trivial differences to, the criterion phantom values. Fat mass from both DXA showed moderate correlations with criterion measures (pencil: r = 0.64; fan: r = 0.67) and moderate differences with the criterion value. The limits of agreement were similar for both fan beam DXA and pencil beam DXA (fan: fat-free soft tissue mass = ?1650 ± 179 g, fat mass = ?357 ± 316 g, bone mineral content = 289 ± 122 g; pencil: fat-free soft tissue mass = ?1701 ± 257 g, fat mass = ?359 ± 326 g, bone mineral content = 177 ± 117 g). DXA also showed excellent precision for bone mineral content (coefficient of variation (%CV) fan = 0.6%; pencil = 1.5%) and fat-free soft tissue mass (%CV fan = 0.3%; pencil = 0.5%) and acceptable reliability for fat measures (%CV fan: fat mass = 2.5%, percent body fat = 2.5%; pencil: fat mass = 5.9%, percent body fat = 5.7%). Both DXA provide precise measures of fat-free soft tissue mass and bone mineral content in lean Australian Football players. DXA-derived fat-free soft tissue mass and bone mineral content are suitable for assessing body composition in lean team sport athletes.  相似文献   

18.
Isometric tests have been used to assess rate of force development (RFD), however variation in testing methodologies are known to affect performance outcomes. The aim of this study was to assess the RFD in the isometric squat (ISqT) using two test protocols and two testing angles. Eleven participants (age: 26.8 ± 4.5 years, strength training experience: 7.1 ± 3.03 years) completed test and retest sessions one week apart, whereby two test protocols with respect to duration and instructions were compared. Isometric peak force (ISqTpeak) and isometric explosive force (ISqTexp) tests were assessed at two joint angles (knee flexion angle 100° and 125°). Force-time traces were sampled and subsequently analysed for RFD measures. Average and instantaneous RFD variables did not meet reliability minimum criteria in ISqTpeak at 100° or 125°. The ISqTexp test at 100° met reliability criteria in the RFD 0–200 and 0–250ms variables. The ISqTexp test at 125° met reliability criteria in the RFD 0–150, 0–200 and 0–250ms variables. Force-time characteristics were optimized at the higher knee joint angle. Average and instantaneous RFD measures obtained using a traditional peak force test do not meet basic reliability criteria. Researchers assessing multi-joint RFD should employ the explosive RFD test protocol as opposed to the traditional isometric peak force protocol.  相似文献   

19.
Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test–retest reliability. Talent identification test–retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland–Altman plots (Limits of Agreement). Spearman’s correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.  相似文献   

20.
The primary aim of this study was to determine whether facial feature tracking reliably measures changes in facial movement across varying exercise intensities. Fifteen cyclists completed three, incremental intensity, cycling trials to exhaustion while their faces were recorded with video cameras. Facial feature tracking was found to be a moderately reliable measure of facial movement during incremental intensity cycling (intra-class correlation coefficient = 0.65–0.68). Facial movement (whole face (WF), upper face (UF), lower face (LF) and head movement (HM)) increased with exercise intensity, from lactate threshold one (LT1) until attainment of maximal aerobic power (MAP) (WF 3464 ± 3364mm, < 0.005; UF 1961 ± 1779mm, = 0.002; LF 1608 ± 1404mm, = 0.002; HM 849 ± 642mm, < 0.001). UF movement was greater than LF movement at all exercise intensities (UF minus LF at: LT1, 1048 ± 383mm; LT2, 1208 ± 611mm; MAP, 1401 ± 712mm; P < 0.001). Significant medium to large non-linear relationships were found between facial movement and power output (r2 = 0.24–0.31), HR (r2 = 0.26–0.33), [La?] (r2 = 0.33–0.44) and RPE (r2 = 0.38–0.45). The findings demonstrate the potential utility of facial feature tracking as a non-invasive, psychophysiological measure to potentially assess exercise intensity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号