首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.  相似文献   

2.
The reported incidence of head and neck injuries in hurling is 0.12 per 1000 hours, but no previous research has quantified head impact characteristics in this sport. Here, a wireless accelerometer and gyroscope captured head impacts, in 20 senior club level hurling players. Peak linear and rotational acceleration and impact location were recorded during three hurling training sessions, each player participating once. A mean of 27.9 impacts (linear acceleration >10g) per player, per session were recorded; 1314 impacts during a total exposure time of 247 minutes. Only 2.6% impacts had peak linear acceleration of >70g and 6.2% had peak rotational acceleration >7900 rad/s2. There were significant differences in the number and magnitude of impacts, quantified by the accelerometer, between three training sessions of differing intensity (?2 0.03–0.09, p < 0.001). This study represents a first step in quantifying head impacts during hurling, demonstrating the feasibility of this technology in the field. The sensors were able to discriminate between sessions of varying intensity. These data can be used to develop athlete monitoring protocols and may be useful in developing innovative helmet-testing standards for hurling. The potential for this technology to provide feedback has clinical utility for team medical personnel.  相似文献   

3.
ABSTRACT

Studies on running biomechanics and energetics are usually conducted on a treadmill. To ensure that locomotion on a treadmill is comparable to locomotion overground, participants need to be expert in the use of the device. This study aimed to identify the number and duration of sessions needed to obtain stable measurements for spatiotemporal and metabolic parameters in unexperienced treadmill runners. Fourteen male recreational runners performed three 15-min treadmill running trials in different days at a submaximal speed. Spatiotemporal and metabolic parameters were registered at minutes: 5, 10, 15 and their within-trial and between-trial changes were analysed using a two-way repeated measures ANOVA and Bonferroni post-hoc test. Within-trial differences were found in step frequency (decreased over time), Step Length and Contact Time (increased), reaching stability at different time points. Ventilator parameters increased, reaching stability after 5–10 min, while heart rate increased progressively over time. The only between-trial differences were an increase in step length and a decrease in step frequency at min 1, between trials 1 and 3. In conclusion, at least three running trials of 15 min are required to familiarize with the device. The last 5 min of the third trial can be regarded as stable measurements.  相似文献   

4.
This study assessed the validity of a tri-axial accelerometer worn on the upper body to estimate peak forces during running and change-of-direction tasks. Seventeen participants completed four different running and change-of-direction tasks (0°, 45°, 90°, and 180°; five trials per condition). Peak crania-caudal and resultant acceleration was converted to force and compared against peak force plate ground reaction force (GRF) in two formats (raw and smoothed). The resultant smoothed (10 Hz) and crania-caudal raw (except 180°) accelerometer values were not significantly different to resultant and vertical GRF for all running and change-of-direction tasks, respectively. Resultant accelerometer measures showed no to strong significant correlations (r = 0.00–0.76) and moderate to large measurement errors (coefficient of variation [CV] = 11.7–23.9%). Crania-caudal accelerometer measures showed small to moderate correlations (r = ? 0.26 to 0.39) and moderate to large measurement errors (CV = 15.0–20.6%). Accelerometers, within integrated micro-technology tracking devices and worn on the upper body, can provide a relative measure of peak impact force experienced during running and two change-of-direction tasks (45° and 90°) provided that resultant smoothed values are used.  相似文献   

5.
Abstract

The purpose of this study was to validate peak acceleration data from an accelerometer contained within a wearable tracking device while walking, jogging and running. Thirty-nine participants walked, jogged and ran on a treadmill while 10 peak accelerations per movement were obtained (n = 390). A single triaxial accelerometer measured resultant acceleration during all movements. To provide a criterion measure of acceleration, a 12-camera motion analysis (MA) system tracked the position of a retro-reflective marker affixed to the wearable tracking device. Peak raw acceleration recorded by the accelerometer significantly overestimated peak MA acceleration (P < 0.01). Filtering accelerometer data improved the relationship with the MA system (P < 0.01). However, only the 10 Hz and 8 Hz cut-off frequencies significantly reduced the errors found. The walk movement demonstrated the highest accuracy, agreement and precision and the lowest relative errors. Linear increases in error were observed for jog compared with walk and for run compared to both other movements. As the magnitude of acceleration increased, the strength of the relationship between the accelerometer and the criterion measure decreased. These results indicate that filtered accelerometer data provide an acceptable means of assessing peak accelerations, in particular for walking and jogging.  相似文献   

6.
Abstract

There has been no previous investigation of the concurrent validity and reliability of the current 5 Hz global positioning system (GPS) to assess sprinting speed or the reliability of integrated GPS–accelerometer technology. In the present study, we wished to determine: (1) the concurrent validity and reliability of a GPS and timing gates to measure sprinting speed or distance, and (2) the reliability of proper accelerations recorded via GPS–accelerometer integration. Nineteen elite youth rugby league players performed two over-ground sprints and were simultaneously assessed using GPS and timing gates. The GPS measurements systematically underestimated both distance and timing gate speed. The GPS measurements were reliable for all variables of distance and speed (coefficient of variation [CV] = 1.62% to 2.3%), particularly peak speed (95% limits of agreement [LOA] = 0.00 ± 0.8 km · h?1; CV = 0.78%). Timing gates were more reliable (CV = 1% to 1.54%) than equivalent GPS measurements. Accelerometer measurements were least reliable (CV = 4.69% to 5.16%), particularly for the frequency of proper accelerations (95% LOA = 1.00 ± 5.43; CV = 14.12%). Timing gates and GPS were found to reliably assess speed and distance, although the validity of the GPS remains questionable. The error found in accelerometer measurements indicates the limits of this device for detecting changes in performance.  相似文献   

7.
An inertial measurement unit (IMU) is widely considered to be an economical alternative to capture human motion in daily activities. Use of an IMU for clinical study, rehabilitation, and in the design of orthoses and prostheses has increased tremendously. However, its use in defining running gait is limited. This study presents a practical method to estimate running spatial and temporal parameters using an inertial sensor by placing it on a shoe. A combination of a zero-crossing method and thresholding is used to identify foot-strike and foot-off based on foot acceleration during running. Stride time, ground contact time and flight time can then be identified. An off-phase segmentation algorithm is applied to estimate stride length and running speed. These two parameters are commonly used to evaluate running efficiency and to differentiate elite runners. This study found that an IMU can estimate foot-strike and foot-off with average absolute time differences of 2.60–6.04 and 2.61–16.28 ms, respectively. Stride time was estimated with error between ? 4.04 and 0.33 ms. Stride length and running speed were estimated with maximum average errors of 45.97 mm and 0.41 km/h.  相似文献   

8.
The purpose of this study was to validate a wireless network of accelerometers and compare it to a hip-mounted accelerometer for predicting energy expenditure in a semi-structured environment. Adults (n = 25) aged 18–30 engaged in 14 sedentary, ambulatory, exercise, and lifestyle activities over a 60-min protocol while wearing a portable metabolic analyser, hip-mounted accelerometer, and wireless network of three accelerometers worn on the right wrist, thigh, and ankle. Participants chose the order and duration of activities. Artificial neural networks were created separately for the wireless network and hip accelerometer for energy expenditure prediction. The wireless network had higher correlations (r = 0.79 vs. r = 0.72, P < 0.01) but similar root mean square error (2.16 vs. 2.09 METs, P > 0.05) to the hip accelerometer. Measured (from metabolic analyser) and predicted energy expenditure from the hip accelerometer were significantly different for the 3 of the 14 activities (lying down, sweeping, and cycle fast); conversely, measured and predicted energy expenditure from the wireless network were not significantly different for any activity. In conclusion, the wireless network yielded a small improvement over the hip accelerometer, providing evidence that the wireless network can produce accurate estimates of energy expenditure in adults participating in a range of activities.  相似文献   

9.
This study investigated the effects of epoch length and cut point selection on adolescent physical activity intensity quantification using vertical axis and vector magnitude (VM) measurement with the ActiGraph GT3X+ accelerometer. Four hundred and nine adolescents (211 males; 198 females) aged 12–16 years of age wore accelerometers during waking hours. The GT3X+ acceleration counts were reintegrated into 1, 5, 15, 30 and 60 s epoch lengths for both vertical axis and VM counts. One cut point was applied to vertical axis counts and three different cut points were applied to VM counts for each epoch length. Significant differences (P < 0.01) in mean total counts per day were observed between vertical axis and VM counts, and between epoch lengths for VM only. Differences in physical activity levels were observed between vertical and VM cut points, and between epoch lengths across all activity intensities. Our findings illustrate the magnitude of differences in physical activity outcomes that occur between axis measurement, cut points and epoch length. The magnitude of difference across epoch length must be considered in the interpretation of accelerometer data and seen as a confounding variable when comparing physical activity levels between studies.  相似文献   

10.
This study developed and validated a vector magnitude (VM) two-regression model (2RM) for use with an ankle-worn ActiGraph accelerometer. For model development, 181 youth (mean ± SD; age, 12.0 ± 1.5 yr) completed 30 min of supine rest and 2–7 structured activities. For cross-validation, 42 youth (age, 12.6 ± 0.8 yr) completed approximately 2 hr of unstructured physical activity (PA). PA data were collected using an ActiGraph accelerometer, (non-dominant ankle) and the VM was expressed as counts/5-s. Measured energy expenditure (Cosmed K4b2) was converted to youth METs (METy; activity VO2 divided by resting VO2). A coefficient of variation (CV) was calculated for each activity to distinguish continuous walking/running from intermittent activity. The ankle VM sedentary behavior threshold was ≤10 counts/5-s, and a CV≤15 counts/5-s was used to identify walking/running. The ankle VM2RM was within 0.42 METy of measured METy during the unstructured PA (P > 0.05). The ankle VM2RM was within 5.7 min of measured time spent in sedentary, LPA, MPA, and VPA (P > 0.05). Compared to the K4b2, the ankle VM2RM provided similar estimates to measured values during unstructured play and provides a feasible wear location for future studies.  相似文献   

11.
Abstract

The purpose of this study was to describe the mechanical characteristics of a trampoline circus act and its individual tracks performed in training and shows using a tri-axial accelerometer. A track is an artist’s specific role within a choreographed act. Seven male acrobats performed their trampoline act during training and shows while wearing a triaxial accelerometer and reported ratings of perceived exertion (RPE) after each trial. Average acceleration (AVG), root mean square (RMS), root mean to the fourth (RM4), time spent in specific acceleration ranges and RPE were measured/recorded from training and show acts. Paired t-tests compared dependent variables between training and show. Acceleration AVG, RMS and RM4 were significantly higher (p < 0.05) in training than show. RPE was significantly higher (p < 0.05) in show than training. No significant differences existed in time spent in any of the acceleration ranges between training and show. GPS devices have been used to manage workloads in field sports but are inoperable in theatres. But, inertial measurements may be an effective alternative to describe mechanical demands in theatre or arena environments. Wearable technology may be useful to coaches to improve understanding of track demands to manage artist workloads.  相似文献   

12.
Velocity profiling using inertial sensors for freestyle swimming   总被引:1,自引:1,他引:0  
The ability to unobtrusively measure velocity in the aquatic environment is a fundamental challenge for engineers and sports scientists and important in assessing the skill level. The aim of this research was to develop a method for velocity profiling in freestyle swimming utilising a purpose-built inertial sensor. Seventeen swimmers with different experience levels participated in this study performing a total of 159 laps in the velocity range from 0.79 to 2.04 m s?1. Data were collected using a triaxial accelerometer and a tethered velocity meter. The collected acceleration data were filtered using a 0.5 Hz Hamming-windowed FIR filter to remove the gravitational acceleration before the lap velocity profiles were calculated. These calculated lap velocity profiles were then compared with the velocity profiles measured by the velocity meter using Bland–Altman analysis. The scattering follows a normal distribution with a mean skewness of 0.96 ± 0.47 and kurtosis of 2.93 ± 1.12. The results show that an inertial sensor alone can be used to determine a lap velocity profile from single point acceleration records.  相似文献   

13.
The purpose of this study was to assess the validity of accelerometers using force plates (i.e., ground reaction force (GRF)) during the performance of different tasks of daily physical activity in children. Thirteen children (10.1 (range 5.4–15.7) years, 3 girls) wore two accelerometers (ActiGraph GT3X+ (ACT), GENEA (GEN)) at the hip that provide raw acceleration signals at 100 Hz. Participants completed different tasks (walking, jogging, running, landings from boxes of different height, rope skipping, dancing) on a force plate. GRF was collected for one step per trial (10 trials) for ambulatory movements and for all landings (10 trials), rope skips and dance procedures. Accelerometer outputs as peak loading (g) per activity were averaged. ANOVA, correlation analyses and Bland–Altman plots were computed to determine validity of accelerometers using GRF. There was a main effect of task with increasing acceleration values in tasks with increasing locomotion speed and landing height (P < 0.001). Data from ACT and GEN correlated with GRF (r = 0.90 and 0.89, respectively) and between each other (r = 0.98), but both accelerometers consistently overestimated GRF. The new generation of accelerometer models that allow raw signal detection are reasonably accurate to measure impact loading of bone in children, although they systematically overestimate GRF.  相似文献   

14.
Research has focused on parameters that are associated with injury risk, e.g. vertical acceleration. These parameters can be influenced by running on different surfaces or at different running speeds, but the relationship between them is not completely clear. Understanding the relationship may result in training guidelines to reduce the injury risk. In this study, thirty-five participants with three different levels of running experience were recruited. Participants ran on three different surfaces (concrete, synthetic running track, and woodchip trail) at two different running speeds: a self-selected comfortable speed and a fixed speed of 3.06 m/s. Vertical acceleration of the lower leg was measured with an accelerometer. The vertical acceleration was significantly lower during running on the woodchip trail in comparison with the synthetic running track and the concrete, and significantly lower during running at lower speed in comparison with during running at higher speed on all surfaces. No significant differences in vertical acceleration were found between the three groups of runners at fixed speed. Higher self-selected speed due to higher performance level also did not result in higher vertical acceleration. These results may show that running on a woodchip trail and slowing down could reduce the injury risk at the tibia.  相似文献   

15.
Player-to-player contact inherent in many unhelmeted sports means that head impacts are a frequent occurrence. Model-Based Image-Matching (MBIM) provides a technique for the assessment of three-dimensional linear and rotational motion patterns from multiple camera views of a head impact event, but the accuracy is unknown for this application. The goal of this study is to assess the accuracy of the MBIM method relative to reflective marker-based motion analysis data for estimating six degree of freedom head displacements and velocities in a staged pedestrian impact scenario at 40 km/h. Results showed RMS error was under 20 mm for all linear head displacements and 0.01–0.04 rad for head rotations. For velocities, the MBIM method yielded RMS errors between 0.42 and 1.29 m/s for head linear velocities and 3.53–5.38 rad/s for angular velocities. This method is thus beneficial as a tool to directly measure six degree of freedom head positional data from video of sporting head impacts, but velocity data is less reliable. MBIM data, combined in future with velocity/acceleration data from wearable sensors could be used to provide input conditions and evaluate the outputs of multibody and finite element head models for brain injury assessment of sporting head impacts.  相似文献   

16.
Little is known about the reliability, validity and smallest detectable differences of selected kinetic and temporal variables recorded by the Zebris FDM-THQ instrumented treadmill especially during running. Twenty male participants (age = 31.9 years (±5.6), height = 1.81 m (±0.08), mass = 80.2 kg (±9.5), body mass index = 24.53 kg/m2 (±2.53)) walked (5 km/h) and ran (10 and 15 km/h) on an instrumented treadmill, wearing running shoes fitted with Pedar-X insoles. A test-double retest protocol was conducted over two consecutive days. Maximal vertical force (Fmax), contact time (CT) and flight time (FT) data from 10 consecutive steps were collected. Within- and between-day reliability, smallest detectable differences (SDD) and validity (95% limits of agreement (LOA)) were calculated. ICC values for the Zebris for Fmax were acceptable (ICC ≥ 0.7) while CT and FT reliability indices were predominantly good (ICC ≥ 0.8) to excellent (ICC ≥ 0.9). The Zebris significantly underestimated Fmax when compared with the Pedar-X. The 95% LOA increased with speed. SDD ranged between 96 N and 169 N for Fmax, 0.017s and 0.055s for CT and 0.021s and 0.026s for FT. In conclusion, Zebris reliability was acceptable to excellent for the variables examined, but inferior in comparison with Pedar-X. With increased running speeds, a bias effect (underestimation) existed for the Zebris compared with Pedar-X.  相似文献   

17.
The purpose of this paper was to present and evaluate a methodology to determine the contribution of bilateral leg and pole thrusts to forward acceleration of the centre of mass (COM) of cross-country skiers from multi-dimensional ground reaction forces and motion capture data. Nine highly skilled cross-country (XC) skiers performed leg skating and V2-alternate skating (V2A) under constant environmental conditions on snow, while ground reaction forces measured from ski bindings and poles and 3D motion with high-speed cameras were captured. COM acceleration determined from 3D motion analyses served as a reference and was compared to the results of the proposed methodology. The obtained values did not differ during the leg skating push-off, and force–time curves showed high similarity, with similarity coefficients (SC) >0.90 in the push-off and gliding phases. In V2A, leg and pole thrusts were shown to contribute 35.1 and 65.9% to the acceleration of the body, respectively. COM acceleration derived from ground reaction forces alone without considering the COM position overestimated the acceleration compared to data from motion analyses, with a mean difference of 17% (P < 0.05) during leg push-off, although the shapes of force–time curves were similar (SC = 0.93). The proposed methodology was shown to be appropriate for determining the acceleration of XC skiers during leg skating push-off from multi-dimensional ground reaction forces and the COM position. It was demonstrated that both the COM position and ground reaction forces are needed to find the source of acceleration.  相似文献   

18.
Self-recall training diaries are a frequently used tool to quantify training load and training information. While accelerometers are predominantly used to validate training diaries, they are unable to validate contextual training information. Thus this study aimed to examine the novel use of data fusion from a wearable camera device (SenseCam) and accelerometer to validate a self-recall training diary. Thirty participants filled in a training diary for 1 day while simultaneously wearing a SenseCam and accelerometer. The training diary was validated using Bland–Altman plots, Spearman’s rank-order correlation, percentage agreement and κ measure of agreement between the diary and the SenseCam and accelerometer. The results demonstrated overall agreement, and no bias, between the training diary and the accelerometer for training intensity, and the SenseCam for duration of activity and travel time. A positive correlation was found for duration (r = 0.82, P < 0.001) and intensity (r = 0.67, P < 0.001). Hundred per cent agreement was found between the SenseCam and training diary for activity, training surface and footwear (κ = 1, P < 0.0001), with a lower agreement noted for sports played (97.3%, κ = 0.91, P < 0.0001). The self-recall training diary was found to be a valid measure of capturing training load and training information using the combined wearable camera device and accelerometer.  相似文献   

19.
This study investigated the validity and reliability of the GymAware PowerTool (GPT). Thirteen resistance trained participants completed three visits, consisting of three repetitions of free-weight back squat, bench press, deadlift (80% one repetition maximum), and countermovement jump. Bar displacement, peak and mean velocity, peak and mean force, and jump height were calculated using the GPT, a three-dimensional motion capture system (Motion Analysis Corporation; 150 Hz), and a force plate (Kistler; 1500 Hz). Least products regression were used to compare agreeability between devices. A within-trial one-way ANOVA, typical error (TE; %), and smallest worthwhile change (SWC) were used to assess reliability. Regression analysis resulted in R2 values of >0.85 for all variables excluding deadlift mean velocity (R2 = 0.54–0.69). Significant differences were observed between visits 3-2 for bench press bar displacement (0.395 ± 0.055 m; 0.383 ± 0.053 m), and deadlift bar displacement (0.557 ± 0.034 m; 0.568 ± 0.034 m). No other significant differences were found. Low to moderate TE (0.6–8.8%) were found for all variables, with SWC ranging 1.7–7.4%. The data provides evidence that the GPT can be used to measure kinetic and kinematic outputs, however, care should be taken when monitoring deadlift performance.  相似文献   

20.
Recommendations for breast support, dynamic breast pain assessment, and implications for sports performance have been made within breast biomechanics research; however, these studies have been based upon short exercise protocols (2–5 min). The aim of this study was to investigate the effect of breast support on multiplanar breast kinematics over a 5-kilometre run. Ten female participants (34D or 32DD) conducted two 5-kilometre runs, in a low and high breast support. Relative multiplanar breast kinematics were averaged over five gait cycles at six intervals of a 5-kilometre run. Increases in multiplanar breast kinematics were reported from the start to the end of the run, with the greatest rate of increase in breast kinematics reported within the first two kilometres of running. The greatest relative increases in breast range of motion (34%), velocity (33%), and acceleration (41%) were reported in the superioinferior direction at the fifth kilometre (33 min of running) in the high breast support. Key findings suggest that the run distance, and therefore run duration, employed for both fundamental research and product validation protocols should be carefully considered and it is suggested that running protocols for assessing breast biomechanics should exceed 7 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号