共查询到20条相似文献,搜索用时 40 毫秒
1.
Graziella Bonetti Mariarosa Carta Martina Montagnana Claudia Lo Cascio Anna Rita Bonfigli Andrea Mosca Roberto Testa 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2016,26(1):68-76
Introduction
Glycolysis affects glucose determination in vitro. The placement of sample tubes in ice-water slurry with plasma separation within 30 minutes is recommended, or alternatively the use of a glycolysis inhibitor. The aim of our two-steps study was to evaluate which Terumo tube is best for glucose determination in routine clinical setting.Materials and methods
In the first study, blood from 100 volunteers was collected into lithium heparin (LH), NaF/Na heparin (FH) and NaF/citrate buffer/Na2EDTA (FC-Mixture) tubes. LH sample was treated as recommended and considered as reference, while FH and FC-Mixture samples were aliquoted, maintained at room temperature (RT) for 1, 2 and 4 hours; centrifuged and plasma analysed in triplicate. In the second study, samples from 375 volunteers were collected in LH, FH and FC-Mixture tubes and held at RT before centrifugation from 10 to 340 minutes, depending on each laboratory practice. Samples were analysed in one analytical run.Results
In the first study, FH glucose concentrations were 5.15 ± 0.66 mmol/L, 5.05 ± 0.65 mmol/L and 5.00 ± 0.65 mmol/L (P < 0.001) in tubes stored at RT for 1, 2 and 4 hours, respectively. Mean biases in all time points exceeded the analytical goal for desirable bias based on biological variation criteria. FC-Mixture glucose concentrations were 5.48 ± 0.65 mmol/L, 5.46 ± 0.6 mmol/L and 5.46 ± 0.64 mmol/L in tubes stored at RT for 1, 2 and 4 hours, respectively. Mean biases for FC-Mixture glucose in all time points reached optimal analytical goals. In the second study, the biases for LH and FH glucose compared to reference FC-Mixture glucose exceeded the preset analytical goals, regardless of the blood collection to centrifugation time interval.Conclusions
FC-mixture tubes glucose concentrations were preserved up to 4h storage at RT. We confirmed that NaF alone does not allow immediate glycolysis inhibition in real life pre-centrifugation storage conditions (up to 340 minutes). FC-Mixture should be used exclusively for glucose determination in laboratories unable to implement the recommended blood samples’ treatment.Key words: glucose, pre-analytical phase, sodium fluoride, citrate acidification, stability 相似文献2.
Goce Dimeski Kendra Bassett Nigel Brown 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(1):117-124
Introduction
Gentamicin due to its low level of resistance and rapid bactericidal activity is commonly used to treat gram-negative bacteria. However, due to its toxic effects it needs to be monitored. To date, no interference has been reported with gentamicin assays.Materials and methods
A patient with leg cellulitis and sepsis received a single dose of gentamicin and a sample was sent for gentamicin analysis. The sample showed high blank absorbance readings on Beckman DxC800 and DC800 analysers with various dilutions. A second sample was received and analysed on a Roche Cobas system to obtain a result. A third sample was received 107 hours later with the same results and this sample was then analysed neat and post ethanol precipitation on all the turbidimetric assays available on the DxC800 analyser.Results
The high blank absorbance was observed upon addition of the reactive reagents due to protein precipitation. Although not obvious from the patient protein results, it was shown the presence of high IgM paraprotein, 18.9 g/L (reference range 0.4-2.3 g/L) was the cause of precipitation, giving high blank readings. Of all the other turbidimetric assays, only vancomicin and valproate showed similar high blank absorbance readings. To be able to provide more rapid results it was shown ethanol could be used as a precipitant of proteins in both calibrators and patient samples with acceptable recovery.Conclusion
IgM paraprotein was identified as the cause of interference with the gentamicin, vancomicin and valproate assays. Protein interference in these assays can be overcome by precipitation with ethanol.Key words: turbidimetry, IgM, paraprotein, interference 相似文献3.
Vanja Radi?i? Biljak Lorena Honovi? Jasminka Matica Branka Kne?evi? Sanela ?imi? Vojak 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(1):73-83
Introduction
Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia.Materials and methods
An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions.Results
The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein.Conclusions
There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia.Key words: survey, chronic kidney disease, estimated glomerular filtration rate (eGFR), albuminuria, proteinuria, creatinine, harmonization 相似文献4.
Maria Salinas Maite López-Garrigós Emilio Flores Joaquín Uris Carlos Leiva-Salinas 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(3):410-415
Introduction
The study was performed to compare and analyze the inter-departmental variability in the request of rarely requested laboratory tests in primary care, as opposed to other more common and highly requested tests.Materials and methods
Data from production statistics for the year 2012 from 76 Spanish laboratories was used. The number of antinuclear antibodies, antistreptolysin O, creatinine, cyclic citrullinated peptide antibodies, deaminated peptide gliadine IgA antibodies, glucose, protein electrophoresis, rheumatoid factor, transglutaminase IgA antibodies, urinalysis and uric acid tests requested was collected. The number of test requests per 1000 inhabitants was calculated. In order to explore the variability the coefficient of quartile dispersion was calculated.Results
The smallest variation was seen for creatinine, glucose, uric acid and urinalysis; the most requested tests. The tests that were least requested showed the greatest variability.Conclusion
Our study shows through a very simplified approach, in a population close to twenty million inhabitants, how in primary care, the variability in the request of laboratory tests is inversely proportional to the request rate.Key words: primary care, laboratory proficiency testing, clinical laboratory services, test requesting, preanalytical phase 相似文献5.
Ka?an Huysal Yasemin U Budak 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(3):416-420
Introduction
Glycosylated hemoglobin (HbA1c) concentrations measured in clinical chemistry laboratories show large differences between their interlaboratory reported values. Laboratory measurements of quality performance should be based on quantitative data. The sigma metrics model provides an objective method for the assessment of current HbA1c assays and is useful in quality management planning. The aim of our study was to evaluate the analytical performance of the MQ-2000 PT HbA1c analyzer test results in the context of our operating conditions on the sigma scale.Materials and methods
The coefficient of variation was determined from the calculated mean and standard deviation evaluated from internal quality control (QC) (N = 168 days) (Shanghai Huachen Biological Reagent Co. Ltd, China) data, and records of external quality data (KBUDEK, İstanbul, Turkey) measured in the period from May to November 2013 were used to determine the bias. The resulting data and total allowable error rate (TEA = 10%) from the Clinical Laboratory Improvement Amendments of 1988 (CLIA’88) were used to calculate the sigma level.Results
The calculated coefficient of variations (CVs) at the two levels, normal (QC1 = 36.6 ± 2.38 mmol/mol) and pathological (QC2 = 84.7 ± 2.68 mmol/mol), were 6.5% and 3.1%, respectively. The average bias between the external QC and MQ-2000 PT during the study period was 4.3%. The calculated average sigma value was 1.19.Conclusions
The MQ-2000 PT HbA1c is a new analyser in the market; there is need for improvement and the method should be controlled with greater attention to ensure quality.Key words: diabetes mellitus, hemoglobin A1c protein, human, chromatography, high pressure liquid chromatography 相似文献6.
Li G Shi W Hug H Chen Y Liu L Yin D 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2012,22(1):92-99
Background
Nonalcoholic fatty liver disease (NAFLD) is associated with the increased burden of kidney. However, there is still no large population study to explore the potential relationship between NAFLD and mild kidney function damage (MKFD) after adjusted for confounding factors. This study is to test the hypothesis that NAFLD is associated with MKFD under controlling the effects of confounding factors.Materials and methods:
Levels of serum fasting glucose, creatinine, cholesterol, triglyceride, alanine aminotransferase and aspartate aminotransferase were analyzed from 1412 Chinese Han adults. Questionnaire and physical examination were performed to explore the potential association of NAFLD with kidney function.Results:
NAFLD was associated with impairment of kidney function. Multivariate-adjusted odds ratio illustrated that, compared to subjects with normal liver, NAFLD subjects had a significantly higher risk of MKFD with or without adjusted for blood glucose and other covariates (P = 0.041). Further results from multi-interaction analysis demonstrated that the underlying mechanisms linked NAFLD with impaired kidney function may be that they share common risk factors and similar pathological processes.Conclusions:
The most striking finding of this study is that NAFLD is negatively associated with kidney function, in nondiabetic population. NAFLD and MKFD may share similar risk factors and/or pathological processes. 相似文献7.
Stanislava Petrovic Natasa Bogavac-Stanojevic Jelena Kotur-Stevuljevic Amira Peco-Antic Ivana Ivanisevic Jasmina Ivanisevic Dusan Paripovic Zorana Jelic-Ivanovic 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(2):266-272
Introduction:
Urinary tract infection (UTI) is one of the most common bacterial infectious diseases in children. The aim of this study was to determine the total prooxidant and antioxidant capacity of children with UTI, as well as changes of oxidative status parameters according to acute inflammation persistence and acute kidney injury (AKI) development.Materials and methods:
The patients enrolled in the study comprised 50 Caucasian children (median age was 6 months) with UTI. Total oxidant status (TOS), total antioxidant status (TAS), oxidative stress index (OSI), inflammation marker C-reactive protein (CRP) and renal function parameters urea and creatinine were analyzed in patient’s serums.Results:
According to duration of inflammation during UTI, TAS values were significantly higher (0.99 vs. 0.58 mmol/L, P = 0.017) and OSI values were significantly lower (0.032 vs. 0.041 AU, P = 0.037) in the subjects with longer duration of inflammation than in the subjects with shorter duration of inflammation. We did not find significant difference in basal values of oxidative status parameters according to AKI development.Conclusions:
OSI values could detect the simultaneous change of TAS and TOS due to change in the oxidative-antioxidant balance during the recovery of children with UTI. TAS and OSI as markers of oxidative stress during UTI are sensitive to accompanying inflammatory condition. Further investigations are needed to evaluate whether TAS, TOS and OSI could be used to monitor disease severity in children with UTI. 相似文献8.
Maria Salinas Maite López-Garrigós Emilio Flores Maria Leiva-Salinas Javier Lugo Francisco J Pomares Alberto Asencio Miguel Ahumada Carlos Leiva-Salinas 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2016,26(1):121-128
Introduction
To study the pre-design and success of a strategy based on the addition of hemoglobin A1c (HbA1c) in the blood samples of certain primary care patients to detect new cases of type 2 diabetes.Materials and methods
In a first step, we retrospectively calculated the number of HbA1c that would have been measured in one year if HbA1c would have been processed, according to the guidelines of the American Diabetes Association (ADA). Based on those results we decided to prospectively measure HbA1c in every primary care patient above 45 years, with no HbA1c in the previous 3 years, and glucose concentration between 5.6-6.9 mmol/L, during an 18 months period. We calculated the number of HbA1c that were automatically added by the LIS based on our strategy, we evaluated the medical record of such subjects to confirm whether type 2 diabetes was finally confirmed, and we calculated the cost of our intervention.Results
In a first stage, according to the guidelines, Hb1Ac should have been added to the blood samples of 13,085 patients, resulting in a cost of 14,973€. In the prospective study, the laboratory added Hb1Ac to 2092 patients, leading to an expense of 2393€. 314 patients had an HbA1c value ≥ 6.5% (48 mmol/mol). 82 were finally diagnosed as type 2 diabetes; 28 thanks to our strategy, with an individual cost of 85.4€; and 54 due to the request of HbA1c by the general practitioners (GPs), with a cost of 47.5€.Conclusion
The automatic laboratory-based strategy detected patients with type 2 diabetes in primary care, at a cost of 85.4€ per new case.Key words: type 2 diabetes, HbA1c, diagnosis, preanalytical phase, test request appropriateness, costs, cost analysis 相似文献9.
Giuseppe Lippi Paola Avanzini Rosalia Aloe Gianfranco Cervellin 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(3):303-307
Introduction:
Blood collection through intravenous lines frequently causes spurious hemolysis. Due to specific structure, the tube holder Holdex® (Greiner Bio-One GmbH, Kremsmuenster, Austria) is supposed to prevent erythrocyte injury in samples collected from catheters, so that we planned a specific study to support this hypothesis.Materials and methods:
Blood was collected from emergency department (ED) patients with 20-gauge catheter. In patients with odd order numbers, first and second tubes were collected with conventional holder (BD Vacutainer One Use Holder, Becton Dickinson, Milan, Italy) and the third with Holdex, whereas in even patients first and second tubes were drawn with Holdex and the third using BD Vacutainer One Use Holder. The first tube was discarded, whereas the second and third were centrifuged and serum was tested for potassium, lactate dehydrogenase (LD) and hemolysis index.Results:
The final study population consisted in 60 ED patients. Concentrations of potassium (4.25 vs. 4.16 mmol/L; P = 0.031), LD (498 vs. 459 U/L; P = 0.039) and cell-free hemoglobin (0.42 vs. 0.22 g/L; P = 0.042) were higher in samples collected with BD Vacutainer One Use Holder than with Holdex. The mean bias of cell-free hemoglobin was −0.4 g/L in samples collected with Holdex. Although the frequency of samples with cell-free hemoglobin > 0.5 g/L was identical (17/60 vs. 17/60; P = 1.00), the frequency of those with concentrations >3.0 g/L was higher using BD Vacutainer One Use Holder than Holdex (4/60 vs. 0/60; P = 0.042).Conclusions:
The use of Holdex for drawing blood from intravenous lines may be effective for reducing gross hemolysis. 相似文献10.
Valentina Vidranski Renata Laskaj Dubravka Sikiric Visnja Skerk 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(2):285-294
Background
Platelet satellitism is a phenomenon of unknown etiology of aggregating platelets around polymorphonuclear neutrophils and other blood cells which causes pseudothrombocytopenia, visible by microscopic examination of blood smears. It has been observed so far in about a hundred cases in the world.Case subject and methods
Our case involves a 73-year-old female patient with a urinary infection. Biochemical serum analysis (CRP, glucose, AST, ALT, ALP, GGT, bilirubin, sodium, potassium, chloride, urea, creatinine) and blood cell count were performed with standard methods on autoanalyzers. Serum protein fractions were examined by electrophoresis and urinalysis with standard methods on autoanalyzer together with microscopic examination of urine sediment. Erythrocyte sedimentation rate, blood culture and urine culture tests were performed with standard methods.Results
Due to typical pathological values for bacterial urinary infection, the patient was admitted to the hospital. Blood smear examination revealed phenomenon, which has persisted for three weeks after the disease has been cured. Blood smears with EDTA as an anticoagulant had platelet satellitism whereas the phenomenon was not observed in tubes with different anticoagulants (Na, Li-heparin) and capillary blood.Discussion
We hypothesize that satellitism was induced by some immunological mechanism through formation of antibodies which have mediated platelets binding to neutrophil membranes and vice versa. Unfortunately we were unable to determine the putative trigger for this phenomenon. To our knowledge this is the second case of platelet satellitism ever described in Croatia.Key words: blood platelets, thrombocytopenia, EDTA, urinary infection 相似文献11.
Branka Kristi? Kirin Renata Zrinski Topi? Slavica Dodig 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(1):112-116
Introduction:
Respiratory syncytial virus (RSV) infection is the most common cause of hospitalization in infants and small children. The aim was to present a 13-months old boy diagnosed with acute airway infection, acute otitis media (AOM) and hepatitis during the RSV-infection.Material and methods:
Serum catalytic activities of alkaline phosphatase (ALP), aspartate aminotranspherase (AST), alanine aminotranspherase (ALT), gamma glutamyl transpherase (GGT), lactate dehydrogenase (LD), and concentrations of bilirubin were monitored during hospitalization and at control examination.Results:
The child had clinical signs and symptoms of respiratory failure, AOM, and laboratory findings of virus infection and liver disease. On admission, catalytic activities of enzymes were markedly increased, especially the activity of ALP (10333 U/L, i.e. 24-fold increase in comparison with the upper reference limit). The highest increased in AST (339 U/L, 4.5-fold), ALT (475 U/L, 10.3-fold) and LD (545 U/L, 1.5-fold) were registered on the 3rd day, and the highest increase in GGT (68 U/L, 3.1-fold) occurred on the 11th day. Seven weeks after discharge AST, ALT, GGT and LD decreased into reference range, and ALP remain mildly increased (478 U/L, 1.1 fold increase). RSV was confirmed in nasal lavage fluid.Conclusion:
Laboratory results in patient with RSV infection needs to be interpreted in the light of both, respiratory and extrapulmonary manifestations of the infection, respectively. 相似文献12.
Philippe B. Katchunga Patrick N. Mirindi Antoine S. Kishabongo Justin C. Cikomola Socrate Bwanamdogo Jan Philippé Marijn M. Speeckaert Joris R. Delanghe 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(3):469-473
Introduction
Diagnosis and monitoring of diabetes mellitus in sub-Saharan Africa, based on blood analyses, are hampered by infrastructural and cultural reasons. The first aim of this study was to evaluate the diagnostic accuracy of glycated nail proteins for diabetes mellitus. The second aim was to compare the course of short- and long-term glycemic biomarkers after 6 months of antidiabetic treatment. These objectives should support our hypothesis that glycated nail proteins could be used as an alternative glycemic biomarker.Materials and methods
This case-control study consisted of 163 black diabetics and 67 non-diabetics of the South Kivu (Democratic Republic of Congo). Diagnostic accuracy of glycated nail proteins was evaluated using ROC curve analysis. At the start of the study, glycated nail protein concentrations were compared between diabetics and non-diabetics, using a nitro blue tetrazolium (NBT) colorimetric method. In a subgroup of 30 diabetics, concentrations of glycated nail proteins, fasting glucose (Accu-Chek® Aviva), serum fructosamine (NBT) and HbA1c (DCA-2000+®) were measured at start and after 6 months.Results
ROC analysis yielded an AUC of 0.71 (95% confidence interval (CI): 0.65-0.76) and a cut-off point of 3.83 μmol/g nail. Concentration of glycated nail proteins was significantly higher (P < 0.001) in diabetics in comparison with non-diabetics. After 6 months of antidiabetic treatment, a significant drop in the fasting glucose concentration (P = 0.017) and concentration of glycated nail proteins (P = 0.008) was observed in contrast to serum fructosamine and HbA1c.Conclusions
Measurement of glycated nail proteins could be used to diagnose and monitor diabetes mellitus in sub-Saharan Africa.Key words: fasting glucose concentration, fructosamine, hemoglobin A1c protein, nails, sub-Saharan Africa, diabetes mellitus 相似文献13.
Corsetti R Lombardi G Barassi A Lanteri P Colombini A D'Eril GM Banfi G 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2012,22(2):237-246
Introduction
The study of cardiac response to strenuous and continuous exercise is crucial to understanding the physiology of endurance. N-terminal proB-type natriuretic peptide (NT-proBNP) is a potential marker for monitoring myocardial wall stress, and troponins (TnT and TnI) are widely used in the diagnosis of cardiac ischemia and infarction. Strenuous exercise may generate transitory ischemia, myocardial stress, and diastolic left ventricular dysfunction, inducing the increased production of both these biomarkers. We measured changes in NT-proBNP and TnT in elite cyclists during a 3-week stage race, a model of strenuous exercise.Materials and methods:
The study population was 9 professional cyclists participating in the 2011 Giro d’Italia. Pre-analytical and analytical phases scrupulously followed official recommendations. Anthropometric data, net energy expenditure and cardiac indexes (rate, diastolic and systolic blood pressure) were recorded. Blood samples were drawn pre-race (day −1) and at days 12 and 22; NT-proBNP and highly sensitive-troponin (Hs-TnT) concentrations were assayed and corrected for plasma volume changes.Results:
Body-mass index decreased and energy expenditure increased by 52% during the race. NT-proBNP concentrations increased [day −1: 23.52 ng/L (9.67–34.33); day 12: 63.46 ng/L (22.15–93.31); P = 0.039; day 22: 89.26 ng/L (34.66–129.78) vs. day −1; P < 0.001] and correlated with heart rate (r = −0.51; P = 0.006), systolic pressure (r = 0.39; P = 0.046) and energy expenditure (r = 0.70; P < 0.001). TnT concentrations did not vary, but a widened TnT amplitude distribution was observed.Conclusions:
Increases in NT-proBNP correlated with higher energy expenditure over a 3-week cycling stage race, possibly indicating myocardial stress. 相似文献14.
Serap Cuhadar Mehmet Koseoglu Aysenur Atay Ahmet Dirican 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2013,23(1):70-77
Introduction:
Optimal storage of serum specimens in central laboratories for a long period for multicenter reference interval studies, or epidemiologic studies remains to be determined. We aimed to examine the analytical stability of chemistry analytes following numerous freeze-thaw and long term storage.Materials and methods:
Serum samples were obtained from 15 patients. Following baseline measurement, sera of each subject were aliquoted and stored at −20 °C for two experiments. A group of sera were kept frozen for up to 1, 2 and 3 months and then analyzed for stability. The other experiment consisted of one to ten times of freeze and thaw cycles. Total of 17 chemistry analytes were assayed at each time point. The results were compared with those obtained from the initial analysis of fresh samples. Median or mean changes from baseline (T0) concentrations were evaluated both statistically and clinically according to the desirable bias.Results:
Of the analytes studied, aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatine kinase (CK), gamma-glutamyl transferase (GGT), direct bilirubin, glucose, creatinine, cholesterol, triglycerides, high density lipoprotein (HDL) were stable in all conditions. Blood urea nitrogen (BUN), uric acid, total protein, albumin, total bilirubin, calcium, lactate dehydrogenase (LD) were changed significantly (P < 0.005).Conclusions:
As a result, common clinical chemistry analytes, with considering the variability of unstable analytes, showed adequote stability after 3 months of storage in sera at −20 °C, or up to ten times of freeze-thaw cycle. All the same, such analysis can only be performed for exceptional cases, and this should be taken into account while planning studies. 相似文献15.
Jelena Joksic Miron Sopic Vesna Spasojevic-Kalimanovska Dimitra Kalimanovska-Ostric Kristina Andjelkovic Zorana Jelic-Ivanovic 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(2):242-251
Introduction
Previous studies have implicated a strong link between circulating plasma resistin and coronary artery disease (CAD). The aim of this study was to evaluate the differences in peripheral blood mononuclear cells (PBMC) resistin mRNA and its plasma protein concentrations between the patients with CAD of different clinical severity.Material and methods
This study included 33 healthy subjects as the control group (CG) and 77 patients requiring coronary angiography. Of the latter 30 was CAD negative whereas 47 were CAD positive [18 with stable angina pectoris (SAP) and 29 with acute coronary syndrome (ACS)]. Circulating resistin was measured by ELISA; PBMC resistin mRNA was determined by real-time PCR.Results
Resistin protein was significantly higher in the ACS group compared to the CG (P = 0.001) and the CAD negative group (P = 0.018). Resistin mRNA expression did not vary across the study groups, despite the positive correlation seen with plasma resistin (ρ = 0.305, P = 0.008). In patients, plasma resistin and PBMC resistin mRNA negatively correlated with HDL-C (ρ = -0.404, P < 0.001 and ρ = -0.257, P = 0.032, respectively). Furthermore, the highest plasma resistin tertile showed the lowest HDL-C (P = 0.006). Plasma resistin was positively associated with serum creatinine (ρ = 0.353, P = 0.002).Conclusion
Significant increase of plasma resistin in patients with ACS compared to CG and CAD negative patients was observed. Despite no change in PBMC resistin mRNA in different disease conditions a positive association between resistin mRNA and resistin plasma protein was evident. Both plasma resistin and PBMC resistin mRNA were negatively associated with plasma HDL-C, and plasma resistin positively with serum creatinine.Key words: resistin, human; gene expression; coronary artery disease; acute coronary syndrome 相似文献16.
Dra?an Butorac Ivana ?elap Sanja Ka?kov Vera Robi? Tomislav Mileti? Zlata Flegar Me?tri? Andrea Hulina Krunoslav Kuna Tihana ?ani? Grubi?i? Marija Grdi? Rajkovi? 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2014,24(2):273-280
Introduction
Postmenopausal women have higher risk of cardiovascular disease. One of the contributing factors could be reduced activity of anti-atherogenic enzyme paraoxonase 1 (PON1). The aim of this study was to examine differences in the lipid status, paraoxonase and arylesterase PON1 activities and PON1 phenotype in women with regular menstrual cycle and in postmenopausal women.Materials and methods:
The study included 51 women in reproductive age (25 in follicular and 26 in luteal phase of the menstrual cycle) and 23 women in postmenopause. Lipid parameters in sera were determined using original reagents and according to manufacturer protocol. PON1 activity in serum was assessed by spectrophotometric method with substrates: paraoxon and phenylacetate. PON1 phenotype was determined by double substrate method.Results:
Compared to the women in follicular and luteal phase, postmenopausal women have significantly higher concentration of triglyceride [0.9 (0.7–1.3), 0.7 (0.6–1.0) vs. 1.5 (0.9–1.7) mmol/L; P = 0.002], cholesterol [5.10 (4.78–6.10), 5.05 (4.70–5.40) vs. 6.30 (5.73–7.23) mmol/L; P < 0.001], LDL [3.00 (2.56–3.63), 3.00 (2.70–3.70) vs. 3.90 (3.23–4.50) mmol/L; P < 0.001], and apolipoprotein B [0.88 (0.75–1.00), 0.79 (0.68–1.00) vs. 1.07 (0.90–1.24) mmol/L; P = 0.002]. PON1 basal [104 (66–260), 106 (63–250) vs. 93 (71–165) U/L; P = 0.847] and salt-stimulated paraoxonase activity [210 (131–462), 211 (120–442) vs. 180 (139–296) U/L; P = 0.857] as well as arylesterase activity [74 (63–82), 70 (54–91) vs. 70 (60–81) kU/L; P = 0.906] and PON1 phenotype (P = 0.810) were not different in the study groups.Conclusion:
There are no differences in PON1 activity and PON1 phenotype between women with regular menstrual cycle and postmenopausal women. 相似文献17.
Yasemin U Budak Ka?an Huysal Hakan Demirci 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(1):97-102
Background
In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.Material and methods
Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.Results
The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).Conclusion
Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume 相似文献18.
Diana Lebherz-Eichinger Remy Schwarzer Michael C. Motal Daniel A. Klaus Andreas Mangold Hendrik J. Ankersmit Gabriela A. Berlakovich Claus G. Krenn Georg A. Roth 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(2):252-261
Introduction
Sparse data are available about the effect of therapy methods on antibody levels in patients with liver failure. The aim of this study was to determine serum immunoglobulin concentrations in patients with chronic hepatic failure (CHF), acute- (ALF), or acute-on-chronic liver failure (ACLF) and to evaluate the impact of MARS treatment or liver transplantation (LT) on antibody levels.Materials and methods
We followed ten patients with ALF, twelve with ACLF and 18 with CHF. Eight patients with ALF and seven with ACLF underwent MARS therapy, whereas the rest received LT. 13 healthy volunteers served as controls. Serum antibody concentrations were measured using ELISA-technique.Results
Median serum levels of IgA, IgG and IgM were significantly increased in patients with CHF compared to ALF or controls (P < 0.02, P < 0.01, and P < 0.01). IgM and IgG concentrations were also significantly elevated in patients with CHF compared to ACLF (IgM, 3.7 vs. 1 g/L, P < 0.001; IgG, 8.7 vs. 3.1 g/L, P = 0.004). Immediately after LT a significant decrease of IgA (6.9 vs. 3.1 g/L, P = 0.004), IgG (8.7 vs. 5.1 g/L, P = 0.02) and IgM (3.7 vs. 1.8 g/L, P = 0.001) was detected in patients with CHF and antibody levels further decreased the days after LT reaching levels comparable to healthy individuals. MARS treatment had no apparent effect on the immunoglobulin profile in patients with ALF or ACLF.Conclusion
We provide evidence that LT reverses hypergammaglobulinemia in patients suffering from CHF within one day, which could be explained to a reconstituted hepatic antibody clearance, whereas MARS treatment has no immediate effect on immunoglobulin levels.Key words: antibodies, immunoglobulins, liver failure, liver transplantation, artificial liver support system, molecular adsorbent recirculating system 相似文献19.
Biljana Pejovi? Jelena Eri?-Marinkovi? Marija Pejovi? Jelena Kotur-Stevuljevi? Amira Peco-Anti? 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2015,25(3):450-459
Introduction
Acute kidney injury (AKI) is common in neonatal intensive care units (NICU). In recent years, every effort is made for early detection of AKI. Our hypothesis was that serum neutrophil gelatinase-associated lipocalin (sNGAL) may be a reliable screening test for early diagnosis of AKI in premature neonates after perinatal asphyxia. Therefore, our aim was to assess the diagnostic accuracy of sNGAL for AKI in premature asphyxiated neonates.Materials and methods
AKI was defined in the third day of life (DOL 3) as a serum creatinine (sCr) increase ≥ 26.5 μmol/L from baseline (the lowest previous sCr). According to the increase of sCr, AKI patients were divided in AKIN1 (sCr increase up to 1.9 baseline) and AKIN2 (sCr increase from 2.0 to 2.9 baseline). sNGAL levels were measured on DOL 1, 3 and 7.Results
AKI was diagnosed in 73 (0.676) of 108 enrolled premature asphyxiated neonates. Sixty one patients (0.836) were classified in AKIN1 and 12 patients (0.164) in AKIN2. sNGAL reached the maximal concentrations on DOL 1 within 4 hours after admission to NICU, being higher in AKI compared with no-AKI group (160.8 ± 113.1 vs. 87.1 ± 81.6; P < 0.001) as well as in AKIN2 compared with AKIN1 group (222.8 ± 112.9 vs. 147.8 ± 109.9; P < 0.001). The best areas under the receiver operating characteristic curves (AUC) for prediction of AKI were 0.72 [95% (0.62-0.80) P < 0.001] on DOL1 at 2h and 0.72 [95% (0.63-0.80) P < 0.001] at 4th hour after admission respectively. The corresponding sNGAL cutoff concentrations were 84.87 ng/mL (sensitivity 69.0% and specificity 71.9%) and 89.43 ng/mL (sensitivity 65.7% and specificity 74.3%).Conclusions
In premature asphyxiated neonates sNGAL measured within the first 4 hours of DOL 1 is predictive of the occurrence and severity of AKI. Therefore, plasma levels of NGAL may be used for early diagnosis of AKI in these patients.Key words: serum neutrophil gelatinase-associated lipocalin, acute kidney injury, premature neonates, biomarker 相似文献20.
Cuhadar S Atay A Koseoglu M Dirican A Hur A 《Biochemia medica : ?asopis Hrvatskoga dru?tva medicinskih biokemi?ara / HDMB》2012,22(2):202-214