首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   30篇
  免费   0篇
教育   15篇
科学研究   13篇
信息传播   2篇
  2022年   1篇
  2021年   4篇
  2020年   2篇
  2019年   2篇
  2018年   2篇
  2015年   4篇
  2014年   2篇
  2013年   6篇
  2012年   1篇
  2011年   2篇
  2008年   1篇
  2007年   1篇
  2005年   1篇
  2004年   1篇
排序方式: 共有30条查询结果,搜索用时 15 毫秒
21.
The Third International Mathematics and Science Study (TIMSS) placed Slovene 9 year olds significantly above the international mean in mathematics and English 9 year olds significantly below. As the project to be described here shows, however, such findings can mask finer differences in numerical abilities and problem-solving which qualitative analysis can reveal. While performance in arithmetic tasks of English 6 year olds was superior to Slovene pre-schoolers of the same age, at 7 years Slovene pupils had caught up and between 8 and 11 years forged ahead. By contrast, Slovene pupils were not quite so successful at problem-solving tasks in comparison with the English sample. Possible improvements, in the first place, might be obtained by a careful synthesis of curricula and instructional strategies but is this too simple a solution? A major goal of this paper will be to provide insight into the limitations of large-scale international studies and research methodologies as well as advocate qualitative approaches which, if not challenging such studies certainly complement and enrich them by setting out to answer another set of research questions. This paper also raises important questions about cultural differences which influence the aims and philosophy of education both directly and indirectly.  相似文献   
22.
Arginase activity is important in polyamines and nitric oxide production which are required for the normal growth of placenta and embryo. A considerable arginase activity is observed in amniotic fluid in women at the end of pregnancy. Lecithin to sphingomyelin (L/S) ratio is widely used in order to assess fetal lung immaturity and prevention of neonatal respiratory distress syndrome, the major cause of neonatal morbidity and mortality. The purpose of our study was to determine if there is a relationship between arginase activity and L/S ratio in amniotic fluid. The study included 170 pregnant women, 18–43 years old, with normal and pathological pregnancy. The arginase activity was measured on the basis of the determination of the amount of liberated ornithine from arginine as substrate. The L/S ratio was done by using a thin layer chromatography. Increased level of arginase activity correlates with the fetal lung maturity. Arginase activity and L/S values may be useful biochemical data, for intrauterine baby maturity.  相似文献   
23.
24.

Introduction:

Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer® Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer® RST blood collection tube in reference with the BD Vacutainer® Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA).

Materials and methods:

Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality.

Results:

Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C.

Conclusions:

Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.  相似文献   
25.
The instrument described here is an all-electronic dielectrophoresis (DEP) cytometer sensitive to changes in polarizability of single cells. The important novel feature of this work is the differential electrode array that allows independent detection and actuation of single cells within a short section ( ~ 300?μm) of the microfluidic channel. DEP actuation modifies the altitude of the cells flowing between two altitude detection sites in proportion to cell polarizability; changes in altitude smaller than 0.25 μm can be detected electronically. Analysis of individual experimental signatures allows us to make a simple connection between the Clausius-Mossotti factor (CMF) and the amount of vertical cell deflection during actuation. This results in an all-electronic, label-free differential detector that monitors changes in physiological properties of the living cells and can be fully automated and miniaturized in order to be used in various online and offline probes and point-of-care medical applications. High sensitivity of the DEP cytometer facilitates observations of delicate changes in cell polarization that occur at the onset of apoptosis. We illustrate the application of this concept on a population of Chinese hamster ovary (CHO) cells that were followed in their rapid transition from a healthy viable to an early apoptotic state. DEP cytometer viability estimates closely match an Annexin V assay (an early apoptosis marker) on the same population of cells.  相似文献   
26.
The purpose of the paper is to present the reasons students at the Faculty of Education in Maribor, Slovenija, chose pedagogy for their study direction, and therefore becoming a teacher. A total 237 second‐year students of the academic year 2003/04 were included in the research. Of the five groups of reasons for choosing this program (altruistic, material, self‐realization and alternative, and reasons arising from aspiration stereotype), students most often asserted self‐realization, including: teaching provides a useful public function for the whole society; as a teacher, I can be an example to children and young people; this profession will give me a chance for professional development during my whole career; and teaching will enable me to use all my abilities (and talents—for example, music, verbal, dancing, etc.) Important differences were found to exist between students of different disciplines.  相似文献   
27.
IntroductionEvaluation of thyroid function is often requested and therefore defining paediatric reference intervals (RIs) is of vital importance. Currently, there is a distinct lack of paediatric RIs for thyroid function tests in Croatia. Thus, we established RIs for thyroid stimulating hormone (TSH), total triiodothyronine (TT3), total thyroxine (TT4), free triiodothyronine (FT3) and free thyroxine (FT4) in the Croatian paediatric population.Materials and methodsReference intervals were calculated from 397 apparently healthy children, aged from 2 days to < 19 years. Serum samples were analysed for thyroid function tests on the Abbott Architect i2000. Age- and sex-specific 95% RIs with 90% confidence intervals were established according to Clinical and Laboratory Standards Institute guidelines. To express the magnitude of sex and age variation, standard deviation ratio (SDR) was calculated using two-level nested ANOVA. The criterion for considering partitioning reference values was set to SDR > 0.3.ResultsAll thyroid function tests required age partitioning, confirmed by SDR above 0.3. There was no need for sex partitioning, confirmed by SDR below 0.3. Still, FT3 was partitioned due to visually noticeable sex related difference for the oldest group (12 years to < 19 years).ConclusionThis is the first study to establish RIs for thyroid function tests in the Croatian paediatric population. We propose RIs for widely used Abbott platform, thus giving laboratories method- and population-specific paediatric RIs for thyroid function tests that should improve clinical test interpretation.  相似文献   
28.
The study done in Slovenia examined grammar and elementary teachers’ perceptions of cooperative learning. The sample consisted of 542 Slovene elementary and grammar school teachers, who teach Slovene. The main question of the research was how teachers assess the value of group learning in comparison to individual forms of learning. From their perceptions, we can draw conclusions about their development, the introduction of group work within lessons and about the encouragement of pupils towards collaborative learning. The main finding of the research is that elementary school teachers place greater importance on group learning than grammar school teachers. In addition, when teachers are grouped according to their years of experience (seniority), there are differences in their assessment of group learning. However, it is not possible to get a linear pattern from the results (e.g. showing that years of experience do or do not contribute to the perception of the importance of group learning), a finding which supports the critical opinion that teachers’ experience depends not only on the quantity (years of experience), but also on the quality of experience.  相似文献   
29.

Introduction

This pilot study aimed to investigate the use of personal protective equipment (PPE) and compliance to the code of conduct (rules defined in institutional, governmental and professional guidelines) among laboratory technicians in Croatian medical laboratories. In addition, we explored the differences in compliance between participants of different age groups, laboratory ownership and accreditation status.

Materials and methods

An anonymous and voluntary survey with 15 questions was conducted among Croatian medical laboratory technicians (N = 217). The questions were divided into two groups: demographic characteristics and the use of PPE. The questions of the second part were graded according to the Likert scale (1-4) and an overall score, shown as median and range (min-max), was calculated for each participant. Differences between the overall scores were tested for each group of participants.

Results

The majority of participants always wear protective clothes at work, 38.7% of them always wear gloves in daily routine, more than 30.0% consume food and almost half of them drink beverages at workplace. A significantly lower overall score was found for participants working in public compared to private laboratories (36 (16-40) vs. 40 (31-40), P < 0.001). There were no statistically significant differences in overall scores for participants of different age groups (P = 0.456) and laboratory accreditation status (P = 0.081).

Conclusion

A considerable percentage of laboratory technicians in Croatian medical laboratories do not comply with safety measures. Lack of compliance is observed in all personnel regardless laboratory accreditation and participants’ age. However, those working in private laboratories adhere more to the code of conduct.Key words: survey, compliance, laboratory technician, universal safety measures, total quality management, clinical laboratory services  相似文献   
30.
Early detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and diagnosis of coronavirus disease 2019 (COVID-19) are priorities during the pandemic. Symptomatic and suspected asymptomatic individuals should be tested for COVID-19 to confirm infection and to be excluded from social interactions. As molecular testing capacity is overloaded during the pandemic, rapid antigen tests, such as lateral flow immunoassays (LFIAs), can be a useful tool as they allow greater test availability and obtain results in a very short time. This short review aims to present the analytical properties of LFIAs in the detection of SARS-CoV-2 in nasopharyngeal swabs. Lateral flow immunoassay is a method that combines thin-layer chromatography and indirect immunochemical sandwich method and allows the detection of a specific SARS-CoV-2 antigen in nasopharyngeal swabs. Swab specimens should be adequately collected and tested as soon as possible. Users should pay attention to quality control and possible interferences. Antigen tests for SARS-CoV-2 show high sensitivity and specificity in cases with high viral loads, and should be used up to five days after the onset of the first symptoms of COVID-19. False positive results may be obtained when screening large populations with a low prevalence of COVID-19 infection, while false negative results may happen due to improper specimen collection or insufficient amount of antigen in the specimen. So as to achieve reliable results, a diagnostic accuracy study of a specific rapid antigen test should be performed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号