首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
体育   4篇
  2013年   2篇
  2009年   1篇
  2006年   1篇
排序方式: 共有4条查询结果,搜索用时 0 毫秒
1
1.
The effect of anthropometric differences in shank to thigh length ratio upon timing and magnitude of joint power production during the drive phase of the rowing stroke was investigated in 14 elite male rowers. Rowers were tested on the RowPerfect ergometer which was instrumented at the handle and foot stretcher to measure force generation, and a nine segment inverse dynamics model used to calculate the rower's joint and overall power production. Rowers were divided into two groups according to relative shank thigh ratio. Time to half lumbar power generation was significantly earlier in shorter shank rowers (p = 0.028) compared to longer shank rowers, who showed no lumbar power generation during the same period of the drive phase. Rowers with a relatively shorter shank demonstrated earlier lumbar power generation during the drive phase resulting from restricted rotation of the pelvic segment requiring increased lumbar extension in these rowers. Earlier lumbar power generation and extension did not appear to directly affect performance measures of the short shank group, and so can be attributed to a technical adaptation developed to maximise rowing performance.  相似文献   
2.
The mechanical responses (i.e. external contact forces and external power) of 25 elite rowers to a race-pace rowing protocol were investigated on the traditional fixed stretcher mechanism and the more recently introduced free-floating stretcher mechanism rowing ergometers. Using a Rowperfect rowing ergometer for both conditions, external contact forces at the handle, stretcher and sliding seat, as well as the displacements of the handle and stretcher, were recorded. The external power was calculated as the product of the force and velocity data from both the handle and stretcher. Significant differences (P < 0.05) between the two conditions for each mechanical parameter were observed. The fixed condition showed larger maximum values for forces and external power and average power throughout the rowing cycle. Moreover, rowing with the fixed mechanism generated higher inertial forces during the transition between the propulsion and recovery phases, especially at the catch of the cycle. The results suggest that: (i) muscular coordination may differ according to the stretcher mechanism used, which could have an impact on the physiological adaptations of muscles; and (ii) the free-floating mechanism may induce lower catch and maximum values for net joint forces and net joint moments that could decrease the risk of injury.  相似文献   
3.
Book Review     
Abstract

The mechanical responses (i.e. external contact forces and external power) of 25 elite rowers to a race-pace rowing protocol were investigated on the traditional fixed stretcher mechanism and the more recently introduced free-floating stretcher mechanism rowing ergometers. Using a Rowperfect rowing ergometer for both conditions, external contact forces at the handle, stretcher and sliding seat, as well as the displacements of the handle and stretcher, were recorded. The external power was calculated as the product of the force and velocity data from both the handle and stretcher. Significant differences (P < 0.05) between the two conditions for each mechanical parameter were observed. The fixed condition showed larger maximum values for forces and external power and average power throughout the rowing cycle. Moreover, rowing with the fixed mechanism generated higher inertial forces during the transition between the propulsion and recovery phases, especially at the catch of the cycle. The results suggest that: (i) muscular coordination may differ according to the stretcher mechanism used, which could have an impact on the physiological adaptations of muscles; and (ii) the free-floating mechanism may induce lower catch and maximum values for net joint forces and net joint moments that could decrease the risk of injury.  相似文献   
4.
Kinematic analysis is done by measurement of the position of bodies, followed by differentiation to get the accelerations of the centres of mass, and it is widely used in sport research. Another common approach is to measure the forces directly. Our intention here is to perform both a kinematic and a kinetic analysis of the same athlete-equipment system, in this case an athlete on a sliding kayak ergometer, with the aim of exploring the errors that may occur with each measurement type. The kayak ergometer with a sliding trolley, instrumented by seven uniaxial force sensors and two goniometers, was placed in a filming area. The instrumentation was validated in the direction of the anteroposterior axis using Newton’s second law. Ten athletes paddled at 92 strokes per minute, following a stationary phase. The comparison between the net force and the time-derivative of the linear momentum indicated a friction level of about 20 N between the trolley and the frame. Other errors came mainly from the inertial parameters of the trunk. A first analysis of contact forces shows a large inter-subject variability, in particular for the forces applied to the footrest and the seat.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号