首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Bond property test of reinforced concrete with all soaking and impressed current method corrosion
Authors:Yannian Zhang  Zhen Lu
Institution:1. School of Civil Engineering, Shenyang Jianzhu University, Shenyang, 110168, China
Abstract:In order to research the bond properties between corroded reinforcement bars and concrete, reinforcement bars with different diameters and different types and concrete with different strength levels were treated specially with all soaking and impressed current method, and the bond properties were measured with the pull-out test. The comparative analysis of the bond properties of corroded reinforcement bars was carried out. The results showed that the types of reinforcement bars and concrete had great influence on the bond strength. The corrosion and volume expansion of reinforcement bars made concrete in tensile condition, which tended to produce cracks in parallel reinforced direction. The typical bond failure of plain reinforcement bars was pull-out, while the typical bond failure of ribbed reinforcement bars was split. The bond strength between corroded reinforcement bars and concrete increased with the increase of concrete strength. The bond strength of plain and ribbed reinforcement bars showed a decreasing trend after the first increase with the increase of the extent of corrosion. Through the test, the coefficients of the bond strength of plain and ribbed reinforcement bars were given, respectively.
Keywords:reinforced concrete  bond property  all soaking and impressed current method  pull-out test  bond failure