首页 | 本学科首页   官方微博 | 高级检索  
     检索      

一种用于宽动态范围上的高精度散射测量的标准方法
引用本文:赵恒凯,方振和,姚传亮,蔡春富,章俊.一种用于宽动态范围上的高精度散射测量的标准方法[J].上海大学学报(英文版),2003,7(3):246-250.
作者姓名:赵恒凯  方振和  姚传亮  蔡春富  章俊
作者单位:School of Communication and Information Engineering,Shanghai University,Shanghai 200072,China,School of Communication and Information Engineering,Shanghai University,Shanghai 200072,China,School of Communication and Information Engineering,Shanghai University,Shanghai 200072,China,School of Communication and Information Engineering,Shanghai University,Shanghai 200072,China,School of Communication and Information Engineering,Shanghai University,Shanghai 200072,China
摘    要:The co-effect of transmitted power fluctuation and system nonlinearity produce deviations in scatterometer measurement results . An internal calibration method to deal with this problem is proposed. The method can result in more precise scatterometric measurements in a wide range. The basic principle of the method is combining real-transmitted-power detection with the calibration of system nonlinearity. A practical scheme to implement the method is also presented, which is developed based on a special designed mechanism of a microwave radiometer-scatterometer combined system.

关 键 词:宽动态范围  高精度散射测量  标准方法  发射功率  微波遥感
收稿时间:5 November 2002

A proposed calibration method for precise wide range scatterometric measurements
Zhao?Heng-Kai,Fang?Zhen-He,Yao?Chuan-Liang,Cai?Chun-Fu,Zhang?Jun.A proposed calibration method for precise wide range scatterometric measurements[J].Journal of Shanghai University(English Edition),2003,7(3):246-250.
Authors:Zhao Heng-Kai    Fang Zhen-He  Yao Chuan-Liang  Cai Chun-Fu  Zhang Jun
Institution:School of Communication and Information Engineering, Shanghai University, Shanghai 200072, China
Abstract:The co-effect of transmitted power fluctuation and system nonlinearity produce deviations in scatterometer measurement results . An internal calibration method to deal with this problem is proposed. The method can result in more precise scatterometric measurements in a wide range. The basic principle of the method is combining real-transmitted-power detection with the calibration of system nonlinearity. A practical scheme to implement the method is also presented, which is developed based on a special designed mechanism of a microwave radiometer-scatterometer combined system.
Keywords:scatterometric calibration  transmitted power  non-linearity  microwave remote sensing  radiometer-scatterometer  
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号