Experimental and thermal stress investigation on side wall deformation at the pendent convective pass in a utility boiler
Authors:Li-ping Pang  Bao-min Sun  Tong Liu
Institution:(1) School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
Abstract:An experimental investigation is performed on side wall deformation at the pendant convective pass(PCP) in a 300 MW and a 600 MW utility boiler. The temperature distributions are measured on the side wall areas of the water-cooled wall, the PCP and the horizontal convective pass (HCP) in the two utility boilers. These experiments show that there are great temperature differences in the side wall areas during the startup process in both utility boilers. These temperature differences can reach 80~150 ℃ with the side wall temperature in the PCP area higher than those in the water-cooled wall and the HCP. The highest temperature in the PCP is close to the flue gas side temperature at the same position in the horizontal flue gas pass. Thermal stress analyses are conducted in the side wall areas in the water-cooled wall, the PCP and the HCP with the software ANSYS. The results show that,at great temperature differences, the PCP side wall undergoes negative thermal stresses that exceed the yield strength causing deformation in the PCP side wall.
Keywords:Utility boiler  Horizontal flue gas side wall in pendant convective pass (PCP)  Deformation  Temperature measurement  Thermal stress analysis