摘    要:采用价廉的涤纶滤膜作为电解体系隔膜,利用阴、阳极同时作用降解含酚工业废水,在反应时间80min,曝气量1.2L/min,电流密度30mA/cm2的最佳条件下,含酚废水COD去除率可达到80%,阴极室COD去除率高于阳极室。

关 键 词:电催化氧化  阴阳极同时氧化  含酚废水

An Experimental Study of Electro-catalytic Oxidation of Phenol-Containing Industrial Wastewater
LUO Sheng-tie,SHEN Li.An Experimental Study of Electro-catalytic Oxidation of Phenol-Containing Industrial Wastewater[J].Journal of Tangshan College,2014(3):70-72.
Authors:LUO Sheng-tie  SHEN Li
Institution:(Department of Environmental & Chemical Engineering Department, Tangshan College, Tangshan 063000, China)
Abstract:This paper studies electro-catalytic oxidation of phenol wastewater using inexpensive polyester membrane as a electrolytic diaphragm system with anode and cathode functioning simul-taneously.The optimum conditions of wastewater treatment are determined as follows:the cur-rent density is 30 mA/cm2 ,aeration rate is 1.2 L/min,electrolysis time is 80 min.Under these conditions,the removal rates of COD could reach 80%.