首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Transient analysis of steam generator in PWR nuclear power plant
Authors:M Tahir Khaleeq Ph D  Lang Wengpeng  He Guoseng
Institution:School of Automation
Abstract:The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics behavior,so the transient analysis of the steam generator should firstly solve their mathematical models.For determination of dynamic behavior and design and testing of the control system, a nonlinear math model is developed using one dimensional conservation equations of mass,momentum and energy of primary and secondary sides of the steam generator. The nonlinear model is verified with standard power plant data available in the references, then the steady states and transient calculations are performed for full power to 5% power reactor operation of the steam generator of Chinese Qinshan Nuclear Power Plant.
Keywords:nuclear power plant  steam generator  nonlinear mathematical model  qinshan nuclear powerplant
本文献已被 CNKI SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏