Parametric optimization of organic Rankine cycle with R245fa/R601a as working fluid
Authors:Jialing?Zhu  Zhenhua?Kang  Qingsong?An  Email author" target="_blank">Tailu?LiEmail author
Institution:1.Key Laboratory of Efficient Utilization of Low and Medium Grade Energy of Ministry of Education,Tianjin University,Tianjin,China;2.School of Energy and Safety Engineering,Tianjin Chengjian University,Tianjin,China
Abstract:In order to select the appropriate working fluids and optimize parameters for medium-temperature geothermally-powered organic Rankine cycle (ORC), R245fa is mixed with R601a at geothermal water temperature of 110 °C. Based on thermodynamics, the characteristics of mixture and its influence on the performance of ORC under different evaporating temperatures and composition proportions are analyzed. Results show that the zeotropic mixture R245fa/R601a (0.4/0.6) has the highest performance. When the evaporating temperature reaches 67 °C, the outlet temperature of geothermal water is 61 °C, the net power output is the highest and the thermal efficiency is about 9%.