置于身体不同部位可穿戴式电子计步器
准确性和可靠性的研究* |
| |
引用本文: | 陈成香,潘加浩,魏书涛,安〓霞.置于身体不同部位可穿戴式电子计步器
准确性和可靠性的研究*[J].广州体育学院学报,2020(5):119-124. |
| |
作者姓名: | 陈成香 潘加浩 魏书涛 安〓霞 |
| |
作者单位: | (1.福建技术师范学院,福建 福清〓350300;2. 三六一度(中国)有限公司,福建 厦门〓361009;3. 广州体育学院,广东 广州〓510500 ) |
| |
摘 要: | 目的:研究在身体不同部位的计步器(手腕、腰部和鞋中底)在步行、慢跑和上下楼梯时记录步数的准确性和可靠性。方法:20名受试者按照实验要求以自我选择的速度依次在400m塑胶跑道上进行步行和慢跑以及上下总共17层的楼梯共10次。所有的步数通过计步器和摄像机记录。一周后所有受试者人员重复上述测试,只记录计步器数据。结果:在步行时,腰部和鞋中底的计步器的精确性显著性的高于腕部(p < .05)。在慢跑和上下楼梯时,鞋中底的计步器的精确性显著性的高于腕部(p < .05)。计步器放置于腰部和鞋中底都表现为较小的相对误差值(<3%)。在慢跑和步行时,放置于所有位置的计步器都表现为较高的可靠性(alpha>0.80)。结论:在慢跑和上下楼梯时,计步器的精确性并不受到放置位置的影响,但是上下楼梯时无论放置在任何身体位置都未达到高度可靠性。综合所有情况,在鞋中底嵌入计步器可能是用以记录人体日常活动情况最佳选择。
|
关 键 词: | 计步器 放置部位 日常活动 准确性 可靠性 |
修稿时间: | 2020/5/12 0:00:00 |
Validity and Reliability of Pedometer Step Counts in Different Wearing Positions |
| |
Institution: | (1. Fujian Polytechnic Normal University, Fuqing 350300, China; 2. 361 Degree (China) Co., Ltd., Xiamen 361009, China; 3. Department of sports training, Guangzhou Sport University, Guangzhou 510500, China) |
| |
Abstract: | Objective: This investigation aims to explore the accuracy and reliability of pedometers placed in different positions on the body (wrist, waist, and in-shoe) during walking, running and stair walking. Methods: Twenty healthy adults were required to walk and run the 400 m around the outdoor track, and continuous ascended and descended 17 short flights of stairs for ten times at a consistent self-selected speed. All the steps were recorded by the pedometers and video (gold standard). This procedure was repeated at the same time one week later without a video record. Results: Waist- (p < .05) and in-shoe-worn (p < .05) pedometer''s accuracy was significantly higher than wrist-worn during walking, and in-shoe-worn higher accuracy than wrist-worn both running (p < .05) and stair walking (p < .05). The MAPE of the pedometers placed on the waist and in-shoe were small MAPE (<3) during all locomotion. The intramodel reliability was exceptionally high (>0.80) when wearing all positions during walking and running. Conclusions: The pedometer''s position does impact the accuracy of step count for running and stair walking. The in-shoe-worn might an accurate and reliable way to assess physical activity in daily life. |
| |
Keywords: | pedometers wearing positions daily activities accuracy reliability |
|