首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundAdults with obesity may display disturbed cardiac chronotropic responses during cardiopulmonary exercise testing, which relates to poor cardiometabolic health and an increased risk for adverse cardiovascular events. It is unknown whether cardiac chronotropic incompetence (CI) during maximal exercise is already present in obese adolescents and, if so, how that relates to cardiometabolic health.MethodsSixty-nine obese adolescents (body mass index standard deviation score = 2.23 ± 0.32, age = 14.1 ± 1.2 years; mean ± SD) and 29 lean adolescents (body mass index standard deviation score = –0.16 ± 0.84, age = 14.0 ± 1.5 years) performed a maximal cardiopulmonary exercise testing from which indicators for peak performance were determined. The resting heart rate and peak heart rate were used to calculate the maximal chronotropic response index. Biochemistry (lipid profile, glycemic control, inflammation, and leptin) was studied in fasted blood samples and during an oral glucose tolerance test within obese adolescents. Regression analyses were applied to examine associations between the presence of CI and blood or exercise capacity parameters, respectively, within obese adolescents.ResultsCI was prevalent in 32 out of 69 obese adolescents (46%) and 3 out of 29 lean adolescents (10%). C-reactive protein was significantly higher in obese adolescents with CI compared to obese adolescents without CI (p = 0.012). Furthermore, peak oxygen uptake and peak cycling power output were significantly reduced (p < 0.05) in obese adolescents with CI vs. obese adolescents without CI. The chronotropic index was independently related to blood total cholesterol (standardized coefficient β = –0.332; p = 0.012) and C-reactive protein concentration (standardized coefficient β = –0.269; p = 0.039).ConclusionCI is more common in the current cohort of obese adolescents, and is related to systemic inflammation and exercise intolerance.  相似文献   

2.
ABSTRACT

Purpose: Badminton is a sport characterized by high-intensity activity interspersed with short rests requiring specific physiological fitness, skills and game tactics. This study aimed to develop, describe and establish the reliability of a novel badminton intermittent exercise protocol, to simulate singles match-play (Part A) and assess match-fitness (Part B). Method: Twelve well-trained male badminton players performed a two-part protocol, mimicking the demands and activity of match-play, on two occasions with at least 72-h recovery. Part A imitated match-play and consisted of 40 stages alternating between 20 s work – receiving shuttlecocks from a launcher and ghosting (simulated) actions – and 40 s rest. Part B was an open-ended period, challenging match-fitness, designed to exhaust participants within 10 min. Physiological responses (heart rate, blood lactate and ratings of perceived exertion) (Part A and B) and time to exhaustion (Part B) were determined both times. Results: There were no differences in performance and physiological responses between trials (p > .05). The protocol demonstrated excellent reliability (intraclass correlation coefficient > 0.89) for all variables. Time to exhaustion (Part B) was 198 ± 98 s and 194 ± 82 s, respectively. Mean (Part A) and peak (Part B) heart rates were 166 ± 9; 191 ± 8 b?min?1 and 166 ± 9; 191 ± 7 b?min?1 and blood lactate concentrations (Part B) 11.8 ± 2.3 and 11.5 ± 2.1 mmol?l?1 for trials 1 and 2, respectively. Conclusion: The protocol reliably induces match-like responses and can be used to assess match-fitness for training/research purposes.  相似文献   

3.
ABSTRACT

Purpose: This study examined the relationships between the Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and resting heart rate variability (HRV) and submaximal 5?-5? test derived measures in novice male soccer players. Methods: Forty players (11.54 ± 0.58 years) from a soccer academy participated in this study, performing physical tests on two different days, separated by 48 h, as follows: (day 1) resting HRV and Yo-Yo IR1 test, and (day 2) anthropometric assessments (for peak height velocity assessment [PHV]) and the 5?-5? test. The Pearson product-moment correlation coefficient was used to determine the correlations between Yo-Yo IR1 performance and the remaining variables. A partial correlation analysis was further performed using age, stature, body mass, distance to PHV, and age at PHV as “confounders.” Results: The highest correlation score was observed between Yo-Yo IR1 performance and resting HRV, when the absolute age was used as confounder (r = 0.72; p < .05). Conclusions: We observed that a practical measure of parasympathetic activity at rest is largely associated with performance obtained during a traditional intermittent endurance performance test.  相似文献   

4.
Abstract

The purpose of the present investigation was to examine the concurrent and construct validity of the three-mile (4.83 km) run as afield test of aerobic capacity. Subjects included 109 college-aged males whose three-mile run time (M = 1310.31 ± 184.48 s) was measured. Fifty of the subjects were given a maximal treadmill stress test, and their peak oxygen consumption (VO2peak) (M = 54.23 ± 7.08 ml.kg?1.min?1) was measured. The three-mile run was conducted on an outdoor 0.25 mile (0.425 km) track, and split tunes were recorded each 110 yds (100.32 m) for the first and last laps and total time was recorded for laps 2 through 11. The correlation coefficient between the run time and VO2peak was -.58, indicating only moderate concurrent validity for the run as afield test for aerobic capacity. A factor analysis conducted on the split time data revealed a three-factor structure of a stable pace phase, an initial sprint, and a final sprint with the stable pace factor accounting for most of the common factor variance (69%). The three-mile run time was used to discriminate successfully between two known groups of subjects in aerobic capacity. These data provide a degree of support for the construct validity of the three-mile run as afield test of aerobic capacity.  相似文献   

5.
Abstract

The purpose of this study was to characterize changes and variability in test performance of swimmers within and between seasons over their elite competitive career. Forty elite swimmers (24 male, 16 female) performed a 7×200-m incremental swimming step test several times each 6-month season (10±5 tests, spanning 0.5–6.0?y). Mixed linear modeling provided estimates of percent change in the mean and individual responses (within-athlete variation as a coefficient of variation) for measures based on submaximal performance (fixed 4-mM lactate), maximal performance (the seventh step) and lean mass (from skinfolds and body mass). Submaximal and maximal swim speed increased within each season from pre to taper phase by ~2.2% for females and ~1.5% for males (95% confidence limits ±1.0%), with variable contributions from stroke rate and stroke length. Most of the gains in speed were lost in the off-season, leaving a net average annual improvement of ~1.0% for females and ~0.6% for males (±1.0%). For submaximal and maximal speed, individual variation between phases was ±2.2% and the typical measurement error was ±0.80%. Step test and anthropometric measures can be used to confidently monitor progressions in swimmers in an elite training program within and between seasons.  相似文献   

6.
Abstract

The primary aim of this study was to develop and validate a golf-specific approach-iron test for use with elite and high-level amateur golfers. Elite (n=26) and high-level amateur (n=23) golfers were recruited for this study. The ‘Approach-Iron Skill Test’ requires players to hit a total of 27 shots. Specifically, three shots are hit at each of nine targets on a specially constructed driving range in a randomised order. A real-time launch monitor positioned behind the player, measured the carry distance for each of these shots. A scoring system was developed based on the percentage error index of each shot, meaning that 81 points was the maximum score possible (with a maximum of three points per shot). Two rounds of the test were performed. For both rounds of the test, elite-level golfers scored significantly higher than their high-level amateur counterparts (56.3±5.6 and 58.5±4.6 points versus 46.0±6.3 and 46.1±6.7 points, respectively) (P<0.05). For both elite and high-level players, 95% limits of agreement statistics also indicated that the test showed good test–retest reliability (2.1±7.9 and 0.2±10.8, respectively). Due to the clinimetric properties of the test, we conclude that the Approach-Iron Skill Test is suitable for further examination with the players examined in this study.  相似文献   

7.
ABSTRACT

The aim of this study was to compare different methods of detecting ventilatory indices (VI) and to investigate the impact of cardiorespiratory fitness (CRF) level on VI detection. Fifty females and fifty males completed a graded exercise test until volitional exhaustion with continuous gas-exchange measurement. The first and second ventilatory indices (VI-1, VI-2) were detected through different single automatic methods and through a semiautomatic method which combines visual and automatic detection methods. Additionally, the VIs were detected visually by two experts which served as the study specific gold standard. When comparing the semiautomatic method at VI-1 (intraclass correlation coefficients (ICC) 0.88 [0.81, 0.92], Bland-Altman bias ± limits of agreement (LoA) 55 ± 334 ml O2 · min?1) and VI-2 (ICC 0.97 [0.96, 0.98], LoA 1 ± 268 ml O2 · min?1) to the visually detected VI, high levels of agreements and no significant differences were found. This was not the case for any of the other automatic methods. Additionally, we couldn’t find any relevant differences regarding the CRF level.

We therefore concluded that the semiautomatic detection method should be used for VI detection, as results are more accurate than in any of the single-automatic methods.

Abbreviations: CPET: cardiopulmonary exercise test; CRF: Cardiorespiratory fitness; VO2peak: peak oxygen uptake; VI-1: first ventilatory indices; VI-2: second ventilatory indices; LoA: Bland-Altman bias ± limits of agreement; ICC: intraclass correlation coefficient.  相似文献   

8.
ABSTRACT

The purpose was to examine the feasibility of the 20m shuttle run test with music and to test its concurrent validity with the original 20m shuttle run test. A total of 386 adolescents (14.5±1.6 years old, 48.9% boys) participated in our study. A self-reported questionnaire was used to assess student’s perception about the 20m shuttle run test with music and the original and to assess perceived exertion. Participants performed randomly the 20m shuttle run test with music and original two weeks apart. Average and maximum heart rate were monitored with heart rate monitors. The 20m shuttle run with music was a feasible test for measuring cardiorespiratory fitness in adolescents. The concurrent validity showed mean differences of 5.1±14.6 for shuttles, 0.3±0.8 km/h for speed, 0.5±4.1 for stages, and 1.5±4.1 for VO2max (all p<0.001) in favour of the 20m shuttle run with music vs. the original 20m shuttle run test. Mean difference for the rating of perceived exertion was 0.4±2.5 points (p=0.003). No significant difference was found between boys and girls. In conclusion, the 20mSRT-music is feasible and presents a good concurrent validity in adolescents, independently of the sex and it will be an alternative and good approach to assess cardiorespiratory fitness.  相似文献   

9.
Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the relationship between finger flexor all-out test scores and climbing ability. Methods: To determine the effect of AF, 22 male climbers performed 2 maximal strength and all-out tests with AF (shoulder and elbow flexed at 90°) and without AF (shoulder flexed at 180° and elbow fully extended). To determine reliability, 9 male climbers completed 2 maximal strength tests with and without AF and an all-out and intermittent test without AF. Results: The maximal strength test without AF more strongly determined climbing ability than the test with AF (r2 = .48 and r2 = .42 for sport climbing; r2 = .66 and r2 = .42 for bouldering, respectively). Force and time variables were highly reliable; the rate of force development and fatigue index had moderate and low reliability. The maximal strength test with AF provided slightly higher reliability than without AF (intraclass correlation coefficient [ICC] = 0.94, ICC = 0.88, respectively). However, smaller maximal forces were achieved during AF (484 ± 112 N) than without AF (546 ± 132 N). All-out test average force had sufficiently high reliability (ICC = 0.92) and a relationship to sport climbing (r2 = .42) and bouldering ability (r2 = .58). Conclusion: Finger strength and endurance measurements provided sufficient construct validity evidence and high reliability for time and force parameters. Arm fixation provides more reliable results; however, the position without AF is recommended as it is more related to climbing ability.  相似文献   

10.
Abstract

The aim of this study was to determine the relative and absolute reliability of second lactate turnpoint using fixed and individual blood lactate method in competitive cyclists. Twenty-eight male, well-trained cyclists (30.2 ± 10.1 years, 72.0 ± 7.4 kg, 177.3 ± 4.7 cm) were recruited to participate in this study. Cyclists completed two incremental cycling tests to exhaustion over a period of 7 days to determine their peak power output, maximal oxygen uptake, maximal heart rate, maximal blood lactate concentration and two lactate turnpoint criteria. The fixed blood concentration criterion (3.5 mM) and an individual criterion were assessed by a lactate-power curve, considering power output, heart rate and oxygen uptake. The main finding of this study was that both lactate turnpoint criteria showed identical low within-subject variation for power output (2.8% coefficient of variation). High values for test–retest correlations ranging from r = 0.70 to r = 0.94 were found for all variables in both threshold criteria. In conclusion, the individual and fixed method to determine the second lactate turnpoint showed similar high absolute and relative reliability in competitive cyclists.  相似文献   

11.
Purpose: Critical power (CP) from the 3-min test was compared to the power outputs associated with thresholds determined from gas exchange parameters that have been used to demarcate the exercise-intensity domains including the respiratory compensation point (RCP), gas exchange threshold (GET), and ventilatory threshold (VT). Method: Twenty-eight participants performed an incremental-cycle ergometer test to exhaustion. The VT was determined from the relationship between the ventilatory equivalent for oxygen uptake (V˙E/V˙O2) versus V˙O2 and the GET was determined using the V-slope method (V˙CO2 vs. V˙O2). The RCP was identified from the V˙E-versus-V˙CO2 relationship. CP was the average power output during the last 30 s of the 3-min all-out test. Linear regression was used to determine the power outputs associated with the RCP, GET, and VT, as well as the V˙O2 associated with CP. Mean differences among the associated power outputs, percent V˙O2 peak, and percent peak power output for the GET, VT, RCP, and CP were analyzed using separate one-way repeated-measures analyses of variance. Results: There were no significant differences between CP (187 ± 47 W) and the power output associated with RCP (190 ± 49 W) or between the power outputs associated with GET (139 ± 37 W) and VT (145 ± 37 W). The power outputs associated with GET and VT, however, were significantly less than were those at CP and associated with RCP. Conclusions: These findings suggest CP and RCP demarcate the heavy from severe exercise-intensity domain and result from a different mechanism of fatigue than that of GET and VT, possibly hyperkalemia.  相似文献   

12.
13.
Purpose: The purpose of this study was to determine if anaerobic performance as measured by the Wingate is decremented in elite female athletes when fraction of inspired oxygen is decreased from 20.9% to 10%. Method: Nine collegiate female soccer players (Mweight = 63.2 ± 10 kg, Mheight = 164 ± 4.7 cm, Mage = 18.6 ± 0.5 year) performed 1 Wingate test under each condition separated by at least 24 hr. Oxygen consumption was measured breath by breath using a Sensor-Medics metabolic cart. Postexercise blood lactates were measured using the finger-stick method. During normoxic and hypoxic (10% inspired oxygen [O2]) conditions, participants inhaled air from a 300-L weather balloon during the 30-s test. Results: Peak power, minimum power, average power, postexercise blood lactate, preexercise and postexercise blood O2 saturation, and total O2 consumed during exercise and during recovery were not statistically different between conditions. However, the Fatigue Index and peak ventilation were significantly greater during hypoxia than normoxia (35 ± 11% vs. 27 ± 9% &; 91.6 ± 14.2 L/min vs. 75.2 ± 11.1 L/min, respectively, p < .05, Cohen's d = ? 0.80 and ? 1.29, respectively). Ventilation was elevated during hypoxia within 5 s of beginning the Wingate and remained elevated throughout exercise. This increased ventilation was sufficient to maintain oxygen consumption during exercise. Conclusion: Under hypoxic conditions, the ventilatory response to the Wingate test is perhaps more important than aerobic capacity per se in determining whether or not Wingate performance is decremented.  相似文献   

14.
ABSTRACT

The aim of this investigation was to assess the reliability and validity of the Fitjump system. Fifty-seven participants (age = 22.62 ± 5.24 years, height = 180.69 ± 12.53 cm, body mass = 75.61 ± 9.56 kg) performed three countermovement jump (CMJ) and squat jump (SJ) with a 1-week interval for test and retest reliability. For validity, the participants performed the same jump protocol on the force platform while being simultaneously measured with the Fitjump system. There was excellent test–retest reliability of the Fitjump system for CMJ and SJ with high intraclass correlation coefficient (ICCs) (0.97 and 0.97, respectively), low coefficient variation (CVs) (2.3% and 2.4%, respectively), and low typical error of estimate [(TEE (%)] (4.0% and 4.4%, respectively). For validity, ICCs were extremely high for CMJ and SJ (0.93 and 0.94, respectively), with low TEE (%) (2.9% and 2.0%, respectively). However, Fitjump overestimated jump height for CMJ and SJ (3.54 and 3.37 cm, respectively; p < 0.001) when compared with the force platform. As a conclusion, the Fitjump system demonstrated excellent test–retest reliability and high relationship with a systematic bias for validity. Therefore, the Fitjump system can be used as a portable tool for monitoring vertical jump changes over time, but it should not be used interchangeably with a force platform.  相似文献   

15.
Objective: To quantify the effects of acute hypoxic exposure on exercise capacity and performance, which includes continuous and intermittent forms of exercise. Design: A systematic review was conducted with a three-level mixed effects meta-regression. The ratio of means method was used to evaluate main effects and moderators providing practical interpretations with percentage change. Data sources: A systemic search was performed using three databases (Google scholar, PubMed and SPORTDiscus). Eligibility criteria for selecting studies: Inclusion was restricted to investigations that assessed exercise performance (time trials (TTs), sprint and intermittent exercise tests) and capacity (time to exhaustion test, TTE) with acute hypoxic (<24?h) exposure and a normoxic comparator. Results: Eighty-two outcomes from 53 studies (N?=?798) were included in this review. The results show an overall reduction in exercise performance/capacity ?17.8?±?3.9% (95% CI ?22.8% to ?11.0%), which was significantly moderated by ?6.5?±?0.9% per 1000 m altitude elevation (95% CI ?8.2% to ?4.8%) and oxygen saturation (?2.0?±?0.4%; 95% CI ?2.9% to ?1.2%). TT (?16.2?±?4.3%; 95% CI ?22.9% to ?9%) and TTE (?44.5?±?6.9%; 95% CI ?51.3% to ?36.7%) elicited a negative effect, whilst indicating a quadratic relationship between hypoxic magnitude and both TTE and TT performance. Furthermore, exercise less than 2 min exhibited no ergolytic effect from acute hypoxia.

Summary/Conclusion: This review highlights the ergolytic effect of acute hypoxic exposure, which is curvilinear for TTE and TT performance with increasing hypoxic levels, but short duration intermittent and sprint exercise seem to be unaffected.  相似文献   

16.
ABSTRACT

Whether the acute coordinative exercise could affect the inhibitory control and food-cue related attention in obese adolescents remains understudied. Therefore, this study used the Stroop test and the food-cue related Stroop test to explore the impacts of 20 min of acute coordinative exercise on the cognitive tests involving inhibitory control and attentional bias towards food-cue related stimuli, respectively, in obese adolescents. Thirty-eight obese adolescents (mean age = 14.63 ± 0.69 years) were equally divided into exercise and control groups. The cognitive tests (i.e., the Stroop test and the food-cue related Stroop test) and hunger scores were conducted and assessed before and after an intervention. The exercise group had significantly larger negative pre-post response time difference in the congruent (?1.04 ± 0.29 ms) and incongruent (?5.76 ± 1.66 ms) conditions of the Stroop test than the control group (ps < 0.01), and a smaller post-interference (1.13 ± 0.14) than the pre-interference (1.31 ± 0.14, p = 0.04). Moreover, a significantly larger negative pre-post response time difference on the food-cue related Stroop test was observed in the exercise group (?4.42 ± 7.20 ms) than the control group (1.76 ± 8.37 ms, p = 0.02). Collectively, an acute coordinative exercise session could induce superior inhibitory control and less attentional bias towards food-cue related stimuli in obese adolescents.  相似文献   

17.
Abstract

Through computer simulation of data this study explored the effectiveness of various estimators of reliability in the context of trials-to-criterion testing. The estimation procedures employed were coefficient alpha, parallel forms, and an estimator, called UEV (unbiased error variance), based on estimates of error variance. Based on the results of the computer simulation, the UEV estimator was recommended as the procedure to employ when a single administration of a trials-to-criterion test is planned. However, if a second test administration is feasible the parallel forms estimator was recommended for estimating the reliability of a trials-to-criterion test.  相似文献   

18.
Abstract

The aim of this study was to include self-paced exercise within a modified Loughborough Intermittent Shuttle Test (LIST-P) in order to quantify key performance variables not possible with prescribed workloads. Sixteen male games players performed two trials of the LIST-P, at least 7 days apart. The LIST-P incorporates 4 × 15-min blocks of “prescribed-pace” activity (participants exercise in time to audible signals) followed by 2 × 15-min blocks of “self-paced” running (no audible signals). Distances covered and mean speeds were monitored during self-paced exercise. Total distance covered (12.54 ± 0.45 km vs. 12.64 ± 0.32 km; P = 0.10) and mean speed (8.37 ± 0.31 km ? h?1 vs. 8.44 ± 0.22 km ? h?1; P = 0.10) was similar between trials. Other indices also showed the test to be reliable (Pearson’s correlation = 0.89 and 0.90 (P < 0.01), total distance and mean speed, respectively; intraclass correlation coefficient = 0.88 and 0.88 (P < 0.01); standard error of measurement = ±0.13 km and ±0.09 km ? h?1; coefficient of variation (CV) = 1.7% and 1.7%; ratio limits of agreement = 1.00 */÷1.03 and 1.01 */÷1.04). Sprint time was also similar between trials (2.60 ± 0.19 s vs. 2.64 ± 0.23 s; P = 0.29). Incorporating self-paced exercise within an established intermittent shuttle running test appears to be a sensitive means of quantifying key performance variables for multiple-sprint sports research.  相似文献   

19.
20.
Abstract

Independent estimates of the errors of measurement and the intra-individual variations have been made for arm strength (Smedley dynamometer) and vertical jumping (Henry apparatus). The intra-individual variations are much larger than the measurement errors; thus they constitute the chief factor that determines test-retest reliability in these two physical performances. The tolerable error for measuring strength is ± 0.82 kg.; for jumping it is ± 0.5 in. In order to avoid loss of accuracy, it is necessary to read the dial or scale with approximately twice this precision. The method of computing test-retest reliability as the ratio of “true score” variance to total variance is found to underestimate the coefficient when the variability of test and retest scores differs by more than 15 percent. A formula for correcting this attenuation is presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号