首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets.  相似文献   

2.
We evaluate the feasibility of manipulating droplets in two dimensions by exploiting Coulombic forces acting on conductive droplets immersed in a dielectric fluid. When a droplet suspended in an immiscible fluid is located near an electrode under a dc voltage, the droplet can be charged by direct contact, by charge transfer along an electrically conducting path, or by both mechanisms. This process is called electrical charging of droplet (ECOD). This charged droplet may then be transported rapidly by exploiting Coulombic forces. We experimentally demonstrate electrical actuation of a charged droplet by applying voltage sequences. A charged droplet is two dimensionally actuated by following the direction of the electrical field signal. The droplet does not contact the surface of the microfluidic chip when it moves. This characteristic is very advantageous because treatments of the substrate surfaces of microfluidic chip become simpler. In order to test the feasibility of using ECOD in a droplet-based microreactor, electrocoalescence of two oppositely charged droplets is also studied. When two droplets approach each other due to Coulombic attraction, a liquid bridge is formed between them. We postulate that if the applied electric field is weaker than a certain critical level, the two droplets coalesce instantaneously when the charges are exchanged and redistributed through this liquid bridge.  相似文献   

3.
The operation of digital microfluidic devices with water droplets manipulated by electrowetting is critically dependent on the static and dynamic stability and lubrication properties of the oil films that separate the droplets from the solid surfaces. The factors determining the stability of the films and preventing surface fouling in such systems are not yet thoroughly understood and were experimentally investigated in this study. The experiments were performed using a standard digital microfluidic cartridge in which water droplets enclosed in a thin, oil-filled gap were transported over an array of electrodes. Stable, continuous oil films separated the droplets from the surfaces when the droplets were stationary. During droplet transport, capillary waves formed in the films on the electrode surfaces as the oil menisci receded. The waves evolved into dome-shaped oil lenses. Droplet deformation and oil displacement caused the films at the surface opposite the electrode array to transform into dimples of oil trapped over the centers of the droplets. Lower actuation voltages were associated with slower film thinning and formation of fewer, but larger, oil lenses. Lower ac frequencies induced oscillations in the droplets that caused the films to rupture. Films were also destabilized by addition of surfactants to the oil or droplet phases. Such a comprehensive understanding of the oil film behavior will enable more robust electrowetting-actuated lab-on-a-chip devices through prevention of loss of species from droplets and contamination of surfaces at points where films may break.  相似文献   

4.
We introduce a novel type of droplet generator that produces droplets of a volume set by the geometry of the droplet generator and not by the flow rates of the liquids. The generator consists of a classic T-junction with a bypass channel. This bypass directs the continuous fluid around the forming droplets, so that they can fill the space between the inlet of the dispersed phase and the exit of the bypass without breaking. Once filled, the dispersed phase blocks the exit of the bypass and is squeezed by the continuous fluid and broken off from the junction. We demonstrate the fixed-volume droplet generator for (i) the formation of monodisperse droplets from a source of varying flow rates, (ii) the formation of monodisperse droplets containing a gradation of solute concentration, and (iii) the parallel production of monodisperse droplets.  相似文献   

5.
We present a novel method of generating and retrieving droplets stored in microfluidic grooves or cavity structures. First we designed and fabricated polydimethylsiloxane microchannels with grooves on the walls and then produced a two-phase flow of oil and aqueous phases to form aqueous phase droplets in an oil state. We propose the following three mechanisms of droplet generation: the contact line on the groove wall continues moving along the wall and descends to the bottom of the cavity, confining the aqueous phase in the cavity; once the interface between the oil and aqueous phases moves into the cavity, the interface contacts the top of the neighboring groove; and a spherical droplet forms at the corner in the cavity due to surface tension. The viscosity of the oil phase and the surface tension of the interface determine whether a droplet can be generated. Then, we could adjust the velocity of the interface and the aspect ratio of the cavity to achieve the optimal conditions for generating the single droplet. We observed that the largest droplet is stably generated without a daughter droplet at typical values of free-stream velocity (10 μl∕min) and groove pitch 110 μm for all three cases with different oil phases (20, 50, and 84 cP). This technique is expected to serve as a platform for droplet-based reaction systems, particularly with regard to monitoring cell behavior, in vitro expression, and possibly even micropolymerase chain reaction chambers.  相似文献   

6.
We present a droplet-based microfluidic system for performing bioassays requiring controlled analyte encapsulation by employing highly flexible on-demand droplet generation. On-demand droplet generation and encapsulation are achieved pneumatically using a microdispensing pump connected to a constant pressure source. The system generates single droplets to the collection route only when the pump is actuated with a designated pressure level and produces two-phase parallel flow to the waste route during the stand-by state. We analyzed the effect of actuation pressure on the stability and size of droplets and optimized conditions for generation of stable droplets over a wide pressure range. By increasing the duration of pump actuation, we could either trigger a short train of identical size droplets or generate a single larger droplet. We also investigated the methodology to control droplet contents by fine-tuning flow rates or implementing a resistance bridge between the pump and main channels. We demonstrated the integrated chip for on-demand mixing between two aqueous phases in droplets and on-demand encapsulation of Escherichia coli cells. Our unique on-demand feature for selective encapsulation is particularly appropriate for bioassays with extremely dilute samples, such as pathogens in a clinical sample, since it can significantly reduce the number of empty droplets that impede droplet collection and subsequent data analysis.  相似文献   

7.
With widespread research studies on electrowetting-on-dielectric (EWOD) for droplet manipulation in the field of lab-on-a-chip, how to improve the driving capability of droplets has increasingly attracted enormous interest. Aiming to decrease driving voltages and improve driving effectiveness, this paper studies the modeling, simulation, and optimization of EWOD devices. The theoretical model is refined mainly in consideration of the saturation effect of the contact angle and then verified by both simulation and experiments. As a design guide to decrease the driving voltage, a theoretical criterion of droplet splitting, the most difficult one among four basic droplet manipulations, is developed and then verified by experimental results. Moreover, a novel sigmoid electrode shape is found by the optimization method based on finite element analysis and achieves better driving effectiveness and consistent bidirectional driving capability, compared with the existing electrode shapes. Taken together, this paper provides an EWOD analysis and optimization method featuring a lower voltage and a better effectiveness and opens up opportunities for optimization designs in various EWOD-based applications.  相似文献   

8.
Droplet microfluidics is a powerful method used to characterize chemical reactions at high throughput. Often detection is performed via in-line optical readout, which puts high demands on the detection system or makes detection of low concentration substrates challenging. Here, we have developed a droplet acoustofluidic chip for time-controlled reactions that can be combined with off-line optical readout. The principle of the platform is demonstrated by the enzymatic conversion of fluorescein diphosphate to fluorescein by alkaline phosphatase. The novelty of this work is that the time of the enzymatic reaction is controlled by physically removing the enzymes from the droplets instead of using chemical inhibitors. This is advantageous as inhibitors could potentially interact with the readout. Droplets containing substrate were generated on the chip, and enzyme-coupled microbeads were added into the droplets via pico-injection. The reaction starts as soon as the enzyme/bead complexes are added, and the reaction is stopped when the microbeads are removed from the droplets at a channel bifurcation. The encapsulated microbeads were focused in the droplets by acoustophoresis during the split, leaving the product in the side daughter droplet to be collected for the analysis (without beads). The time of the reaction was controlled by using different outlets, positioned at different lengths from the pico-injector. The enzymatic conversion could be measured with fluorescence readout in a separate PDMS based assay chip. We show the ability to perform time-controlled enzymatic assays in droplet microfluidics coupled to an off-line optical readout, without the need of enzyme inhibitors.  相似文献   

9.
This work proposes the use of charged droplets driven by the Coulombic force as solution-phase reaction chambers for biological microreactions. A droplet can be charged near an electrode under dc voltage by direct contact to the electrode. This process is called electrical charging of droplet (ECOD). This charged droplet can then be transported rapidly between electrodes following the arc of an electric field line by exploiting electrostatic force. As on-demand electrocoalescence, both alkalization of phenolphthalein and bioluminescence reaction of luciferase in the presence of adenosine triphosphate are studied to test the feasibility of the biochemical microreactors using ECOD. Two oppositely charged droplets are merged to have a color change immediately after microchemical reaction. The applicability of an ECOD-driven droplet to measurement of glucose concentration is also tested. The glucose concentration is measured using a colorimetric enzyme-kinetic method based on Trinder’s reaction [J. Clin. Pathol. 22, 158 (1969)]. The color change in the merged droplet is detected with an absorbance measurement system consisting of a photodiode and a light emitting diode.  相似文献   

10.
The overall traffic of droplets in a network of microfluidic channels is strongly influenced by the liquid properties of the moving droplets. In particular, the effective hydrodynamic resistance of individual droplets plays a key role in their global behavior. Here we propose two simple and low-cost experimental methods for measuring this parameter by analyzing the dynamics of a regular sequence of droplets injected into an “asymmetric loop” network. The choice of a droplet taking either route through the loop is influenced by the presence of previous droplets that modulate the hydrodynamic resistance of the branches they are sitting in. We propose to extract the effective resistance of a droplet from easily observable time series, namely, from the choices the droplets make at junctions and from the interdroplet distances. This becomes possible when utilizing a recently proposed theoretical model based on a number of simplifying assumptions. Here we present several sets of measurements of the hydrodynamic resistance of droplets, expressed in terms of a “resistance length.” The aim is twofold: (1) to reveal its dependence on a number of parameters, such as the viscosity, the volume of droplets, their velocity as well as the spacing between them. At the same time (2), by using a standard measurement technique, we compare the limitations of the proposed methods. As an important result of this comparison, we obtain the range of validity of the simplifying assumptions made in the theoretical model.  相似文献   

11.
The behavior of a droplet train in a microfluidic network with hydrodynamic traps in which the hydrodynamic resistive properties of the network are varied is investigated. The flow resistance of the network and the individual droplets guide the movement of droplets in the network. In general, the flow behavior transitions from the droplets being immobilized in the hydrodynamic traps at low flow rates to breaking up and squeezing of the droplets at higher flow rates. A state diagram characterizing these dynamics is presented. A simple hydrodynamic circuit model that treats droplets as fluidic resistors is discussed, which predicts the experimentally observed flow rates for droplet trapping in the network. This study should enable the rational design of microfuidic devices for passive storage of nanoliter-scale drops.  相似文献   

12.
We present a novel use for channel structures in microfluidic devices, whereby two two-phase emulsions, one created on-chip, the other off-chip, are rapidly mixed with each other in order to allow for the coalescence of one emulsion with the other. This approach has been motivated by the difficulty in introducing aqueous cross linking agents into droplets by utilising conventional approaches. These conventional approaches include continuous introduction of the different aqueous reagents before droplet formation or alternatively formation of individual droplets of each reagent and subsequent droplet merging later in the microfluidic device. We show that our approach can decrease the mixing time for these fluidic systems by a factor greater than 10 times when compared to a standard microfluidic channel without structures, thereby also allowing for additional reaction time within the microfluidic device. This method shows an application for microfluidic channel structures not before demonstrated, also demonstrating an alternative method for introducing reagents such as cross linkers which link polymer chains to form particles, and provides an example where enzymes are immobilized in monodisperse particles.  相似文献   

13.
Digital microfluidics based on electrowetting on dielectric is an emerging popular technology that manipulates single droplets at the microliter or even the nanoliter level. It has the unique advantages of rapid response, low reagent consumption, and high integration and is mainly applied in the field of biochemical analysis. However, currently, this technology still has a few problems, such as high control voltage, low droplet velocity, and continuity in flow, limiting its application. In this paper, through theoretical analysis and numerical simulation, it is deduced that a drive electrode with a crescent configuration can reduce the driving voltage. The experimental results not only validate this deduction but also indicate that crescent electrode can improve the droplet motion continuity and the success in split rate.  相似文献   

14.
In this study, droplet formations in microfluidic double T-junctions (MFDTD) are investigated based on a two-dimensional numerical model with volume of fluid method. Parametric ranges for generating alternating droplet formation (ADF) are identified. A physical background responsible for the ADF is suggested by analyzing the dynamical stability of flow system. Since the phase discrepancy between dispersed flows is mainly caused by non-symmetrical breaking of merging droplet, merging regime becomes the alternating regime at appropriate conditions. In addition, the effects of channel geometries on droplet formation are studied in terms of relative channel width. The predicted results show that the ADF region is shifted toward lower capillary numbers when channel width ratio is less than unity. The alternating droplet size increases with the increase of channel width ratio. When this ratio reaches unity, alternating droplets can be formed at very high water fraction (wf = 0.8). The droplet formation in MFDTD depends significantly on the viscosity ratio, and the droplet size in ADF decreases with the increase of the viscosity ratio. The understanding of underlying physics of the ADF phenomenon is useful for many applications, including nanoparticle synthesis with different concentrations, hydrogel bead generation, and cell transplantation in biomedical therapy.  相似文献   

15.
Here, we report a unique microfluidic technique that utilizes a membrane filter and plug-in tubes to remove oil and pack water-in-oil droplets for controlled incubation of droplet-based assays. This technique could be modularly incorporated into most droplet-generation devices without a need to alter the original designs. Our results show that removing excess oil to form tightly packed droplets allows for extended and controllable incubation for droplets traveling in microchannels. The efficiency of this technique was evaluated and confirmed using a time-dependent enzyme assay with a fluorometric readout. The system is also readily generalizable to control inter-droplet distance, crucial for studying droplet communication and pattern formation.  相似文献   

16.
Digital microfluidics is an elegant technique based on single droplets for the design, composition, and manipulation of microfluidic systems. In digital microfluidics, especially in the electrowetting on dielectric (EWOD) system, each droplet acts as an independent reactor, which enables a wide range of multiple parallel biological and chemical reactions at the microscale. EWOD digital microfluidics reduces reagent and energy consumption, accelerates analysis, enables point-of-care diagnostic, simplifies integration with sensors, etc. Such a digital microfluidic system is especially relevant for droplet digital PCR (ddPCR), thanks to its nanoliter droplets and well-controlled volume distribution. At low DNA concentration, these small volumes allow less than one DNA strand per droplet on average (limited dilution) so that after a fixed number of PCR cycles (endpoint PCR), only the DNA in droplets containing the sequence of interest has been amplified and can be detected by fluorescence to yield an accurate count of the sequences of interest using statistical models. Focusing on ddPCR, this article summarizes the latest development and research on EWOD technology for droplet PCR over the last decade.  相似文献   

17.
A tiny droplet containing nano∕microparticles commonly handled in digital microfluidic lab-on-a-chip is regarded as a micro-optical component with tunable transmittance at programmable positions for the application of micro-opto-fluidic-systems. Cross-scale electric manipulations of droplets on a millimeter scale as well as suspended particles on a micrometer scale are demonstrated by electrowetting-on-dielectric (EWOD) and particle chain polarization, respectively. By applying electric fields at proper frequency ranges, EWOD and polarization can be selectively achieved in designed and fabricated parallel plate devices. At low frequencies, the applied signal generates EWOD to pump suspension droplets. The evenly dispersed particles reflect and∕or absorb the incident light to exhibit a reflective or dark droplet. When sufficiently high frequencies are used on to the nonsegmented parallel electrodes, a uniform electric field is established across the liquid to polarize the dispersed neutral particles. The induced dipole moments attract the particles each other to form particle chains and increase the transmittance of the suspension, demonstrating a transmissive or bright droplet. In addition, the reflectance of the droplet is measured at various frequencies with different amplitudes.  相似文献   

18.
This study reports a droplet-based microfluidic device for on-demand electrostatic droplet charging and sorting. This device combines two independent modules: one is a hydrodynamic flow focusing structure to generate water-in-oil droplets, and the other is the two paired-electrodes for charging and sorting of the droplets. Depending on the polarity on charging electrodes, water-in-oil droplets can be electrostatically charged positively or negatively, followed by automatic real-time electric sorting. This approach will be useful when preformed droplets, with a positive, a negative, or with no charge, need to be manipulated for further on-chip droplet manipulation.  相似文献   

19.
We present dual-mode, on-demand droplet routing in a multiple-outlet microfluidic device using an oil-based magnetic fluid. Magnetite (Fe3O4) nanoparticle-contained oleic acid (MNOA) was used as a carrier phase for droplet generation and manipulation. The water-in-MNOA droplets were selectively distributed in a curved microchannel with three branches by utilizing both a hydrodynamic laminar flow pattern and an external magnetic field. Without the applied magnetic field, the droplets travelled along a hydrodynamic centerline that was displaced at each bifurcating junction. However, in the presence of a permanent magnet, they were repelled from the centerline and diverted into the desired channel when the repelled distance exceeded the minimum offset allocated to the channel. The repelled distance, which is proportional to the magnetic field gradient, was manipulated by controlling the magnet''s distance from the device. To evaluate routing performance, three different sizes of droplets with diameters of 63, 88, and 102 μm were directed into designated outlets with the magnet positioned at varying distances. The result demonstrated that the 102-μm droplets were sorted with an accuracy of ∼93%. Our technique enables on-demand droplet routing in multiple outlet channels by simply manipulating magnet positions (active mode) as well as size-based droplet separation with a fixed magnet position (passive mode).  相似文献   

20.
Simon MG  Lin R  Fisher JS  Lee AP 《Biomicrofluidics》2012,6(1):14110-1411013
Here, we present a microfluidic droplet trap that takes advantage of the net Laplace pressure force generated when a droplet is differentially constricted. Mathematical simulations were first used to understand the working range of the component; followed by finite element modeling using the CFD software package to further characterize the behavior of the system. Controlled release of the trapped droplets is also demonstrated through both a mechanical method and a chemical method that manipulates the total pressure exerted on the trapped droplet. The unique design of this trapping device also provides the capability for selection of a single droplet from a train, as well as droplet fusion.  相似文献   