首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Concurrent droplet charging and sorting by electrostatic actuation   总被引:1,自引:0,他引:1  
This paper presents a droplet-based microfluidic device for concurrent droplet charging and sorting by electrostatic actuation. Water-in-oil droplets can be charged on generation by synchronized electrostatic actuation. Then, simultaneously, the precharged droplets can be electrostatically steered into any designated laminar streamline, thus they can be sorted into one of multiple sorting channels one by one in a controlled fashion. In this paper, we studied the size dependence of the water droplets under various relative flow rates of water and oil. We demonstrated the concurrent charging and sorting of up to 600 droplets∕s by synchronized electrostatic actuation. Finally, we investigated optimized voltages for stable droplet charging and sorting. This is an essential enabling technology for fast, robust, and multiplexed sorting of microdroplets, and for the droplet-based microfluidic systems.  相似文献   

2.
We evaluate the feasibility of manipulating droplets in two dimensions by exploiting Coulombic forces acting on conductive droplets immersed in a dielectric fluid. When a droplet suspended in an immiscible fluid is located near an electrode under a dc voltage, the droplet can be charged by direct contact, by charge transfer along an electrically conducting path, or by both mechanisms. This process is called electrical charging of droplet (ECOD). This charged droplet may then be transported rapidly by exploiting Coulombic forces. We experimentally demonstrate electrical actuation of a charged droplet by applying voltage sequences. A charged droplet is two dimensionally actuated by following the direction of the electrical field signal. The droplet does not contact the surface of the microfluidic chip when it moves. This characteristic is very advantageous because treatments of the substrate surfaces of microfluidic chip become simpler. In order to test the feasibility of using ECOD in a droplet-based microreactor, electrocoalescence of two oppositely charged droplets is also studied. When two droplets approach each other due to Coulombic attraction, a liquid bridge is formed between them. We postulate that if the applied electric field is weaker than a certain critical level, the two droplets coalesce instantaneously when the charges are exchanged and redistributed through this liquid bridge.  相似文献   

3.
Here, we report a unique microfluidic technique that utilizes a membrane filter and plug-in tubes to remove oil and pack water-in-oil droplets for controlled incubation of droplet-based assays. This technique could be modularly incorporated into most droplet-generation devices without a need to alter the original designs. Our results show that removing excess oil to form tightly packed droplets allows for extended and controllable incubation for droplets traveling in microchannels. The efficiency of this technique was evaluated and confirmed using a time-dependent enzyme assay with a fluorometric readout. The system is also readily generalizable to control inter-droplet distance, crucial for studying droplet communication and pattern formation.  相似文献   

4.
This work proposes the use of charged droplets driven by the Coulombic force as solution-phase reaction chambers for biological microreactions. A droplet can be charged near an electrode under dc voltage by direct contact to the electrode. This process is called electrical charging of droplet (ECOD). This charged droplet can then be transported rapidly between electrodes following the arc of an electric field line by exploiting electrostatic force. As on-demand electrocoalescence, both alkalization of phenolphthalein and bioluminescence reaction of luciferase in the presence of adenosine triphosphate are studied to test the feasibility of the biochemical microreactors using ECOD. Two oppositely charged droplets are merged to have a color change immediately after microchemical reaction. The applicability of an ECOD-driven droplet to measurement of glucose concentration is also tested. The glucose concentration is measured using a colorimetric enzyme-kinetic method based on Trinder’s reaction [J. Clin. Pathol. 22, 158 (1969)]. The color change in the merged droplet is detected with an absorbance measurement system consisting of a photodiode and a light emitting diode.  相似文献   

5.
One challenge of generating a liquid aerosol is finding an efficient way to break up bulk amounts of the compound into micron-sized droplets. Traditional methods of aerosol generation focus on the principle of creating the liquid droplets by blowing air at high speed over or through a liquid. In this study, a novel micropump droplet generator (MDG) is proposed based on a microfluidics device to produce monodisperse droplets on demand (DoD). The micropump design was employed to both pump the fluid into the air and to encourage droplet breakup and aerosol formation. Computational simulation modeling of the new MDG was developed and validated with comparisons to experimental data for current generators. The device was found to produce an aerosol similar to a vibrating orifice DoD device. Most importantly, the input power required by the newly proposed device (MDG) was several orders of magnitude below existing DoD generators for a similar droplet output. Based on the simulation results obtained in comparison with current DoD generators, the MDG device performed effectively at higher frequencies, smaller nozzle diameters, and regardless of the liquid viscosity of the solution.  相似文献   

6.
The applicability of droplet-based microfluidic systems to many research fields stems from the fact that droplets are generally considered individual and self-contained reaction vessels. This study demonstrates that, more often than not, the integrity of droplets is not complete, and depends on a range of factors including surfactant type and concentration, the micro-channel surface, droplet storage conditions, and the flow rates used to form and process droplets. Herein, a model microfluidic device is used for droplet generation and storage to allow the comparative study of forty-four different oil/surfactant conditions. Assessment of droplet stability under these conditions suggests a diversity of different droplet failure modes. These failure modes have been classified into families depending on the underlying effect, with both numerical and qualitative models being used to describe the causative effect and to provide practical solutions for droplet failure amelioration in microfluidic systems.  相似文献   

7.
We here present and characterize a programmable nanoliter scale droplet-on-demand device that can be used separately or readily integrated into low cost single layer rapid prototyping microfluidic systems for a wide range of user applications. The passive microfluidic device allows external (off-the-shelf) electronically controlled pinch valves to program the delivery of nanoliter scale aqueous droplets from up to 9 different inputs to a central outlet channel. The inputs can be either continuous aqueous fluid streams or microliter scale aqueous plugs embedded in a carrier fluid, in which case the number of effective input solutions that can be employed in an experiment is no longer strongly constrained (100 s–1000 s). Both nanoliter droplet sequencing output and nanoliter-scale droplet mixing are reported with this device. Optimization of the geometry and pressure relationships in the device was achieved in several hardware iterations with the support of open source microfluidic simulation software and equivalent circuit models. The requisite modular control of pressure relationships within the device is accomplished using hydrodynamic barriers and matched resistance channels with three different channel heights, custom parallel reversible microfluidic I/O connections, low dead-volume pinch valves, and a simply adjustable array of external screw valves. Programmable sequences of droplet mixes or chains of droplets can be achieved with the device at low Hz frequencies, limited by device elasticity, and could be further enhanced by valve integration. The chip has already found use in the characterization of droplet bunching during export and the synthesis of a DNA library.  相似文献   

8.
We present a novel use for channel structures in microfluidic devices, whereby two two-phase emulsions, one created on-chip, the other off-chip, are rapidly mixed with each other in order to allow for the coalescence of one emulsion with the other. This approach has been motivated by the difficulty in introducing aqueous cross linking agents into droplets by utilising conventional approaches. These conventional approaches include continuous introduction of the different aqueous reagents before droplet formation or alternatively formation of individual droplets of each reagent and subsequent droplet merging later in the microfluidic device. We show that our approach can decrease the mixing time for these fluidic systems by a factor greater than 10 times when compared to a standard microfluidic channel without structures, thereby also allowing for additional reaction time within the microfluidic device. This method shows an application for microfluidic channel structures not before demonstrated, also demonstrating an alternative method for introducing reagents such as cross linkers which link polymer chains to form particles, and provides an example where enzymes are immobilized in monodisperse particles.  相似文献   

9.
Precise analysis of the aquatic cells and their responses to the toxic chemicals, i.e., water disinfective agents, is of crucial importance due to their role in the ecosystem. We demonstrate the application of the droplets based millifluidic tool for isolating and longtime monitoring of single Paramecium tetraurelia cells using a large number of water-in-oil emulsion droplets. Due to the automated monitoring of the fluorescence signal, the droplets containing cells are distinguished from the empty reservoirs. A viability indicator is used to follow the metabolic dynamic of the cells in every single droplet. Finally, we perform ecotoxicity tests in droplets, exposing the encapsulated paramecia cells to silver nitrate for determination of EC50 levels, and compare the output with the conventional microtiter plate assay.  相似文献   

10.
In this study, a microfluidic process is proposed for preparing monodisperse micrometer-sized hydrogel beads. This process utilizes non-equilibrium aqueous droplets formed in a polar organic solvent. The water-in-oil droplets of the hydrogel precursor rapidly shrunk owing to the dissolution of water molecules into the continuous phase. The shrunken and condensed droplets were then gelled, resulting in the formation of hydrogel microbeads with sizes significantly smaller than the initial droplet size. This study employed methyl acetate as the polar organic solvent, which can dissolve water at 8%. Two types of monodisperse hydrogel beads—Ca-alginate and chitosan—with sizes of 6–10 μm (coefficient of variation < 6%) were successfully produced. In addition, we obtained hydrogel beads with non-spherical morphologies by controlling the degree of droplet shrinkage at the time of gelation and by adjusting the concentration of the gelation agent. Furthermore, the encapsulation and concentration of DNA molecules within the hydrogel beads were demonstrated. The process presented in this study has great potential to produce small and highly concentrated hydrogel beads that are difficult to obtain by using conventional microfluidic processes.  相似文献   

11.
In this paper, we propose a continuous flow droplet-based microfluidic platform for magnetic particle-based assays by employing in-droplet washing. The droplet-based washing was implemented by traversing functionalized magnetic particles across a laterally merged droplet from one side (containing sample and reagent) to the other (containing buffer) by an external magnetic field. Consequently, the magnetic particles were extracted to a parallel-synchronized train of washing buffer droplets, and unbound reagents were left in an original train of sample droplets. To realize the droplet-based washing function, the following four procedures were sequentially carried in a droplet-based microfluidic device: parallel synchronization of two trains of droplets by using a ladder-like channel network; lateral electrocoalescence by an electric field; magnetic particle manipulation by a magnetic field; and asymmetrical splitting of merged droplets. For the stable droplet synchronization and electrocoalescence, we optimized droplet generation conditions by varying the flow rate ratio (or droplet size). Image analysis was carried out to determine the fluorescent intensity of reagents before and after the washing step. As a result, the unbound reagents in sample droplets were significantly removed by more than a factor of 25 in the single washing step, while the magnetic particles were successfully extracted into washing buffer droplets. As a proof-of-principle, we demonstrate a magnetic particle-based immunoassay with streptavidin-coated magnetic particles and fluorescently labelled biotin in the proposed continuous flow droplet-based microfluidic platform.  相似文献   

12.
We report an in-depth study of the long-term reproducibility and reliability of droplet dispensing in digital microfluidic devices (DMF). This involved dispensing droplets from a reservoir, measuring the volume of both the droplet and the reservoir droplet and then returning the daughter droplet to the original reservoir. The repetition of this process over the course of several hundred iterations offers, for the first time, a long-term view of droplet dispensing in DMF devices. Results indicate that the ratio between the spacer thickness and the electrode size influences the reliability of droplet dispensing. In addition, when the separation between the plates is large, the volume of the reservoir greatly affects the reproducibility in the volume of the dispensed droplets, creating "reliability regimes." We conclude that droplet dispensing exhibits superior reliability as inter-plate device spacing is decreased, and the daughter droplet volume is most consistent when the reservoir volume matches that of the reservoir electrode.  相似文献   

13.
Novel on-demand droplet generation for selective fluid sample extraction   总被引:1,自引:0,他引:1  
Lin R  Fisher JS  Simon MG  Lee AP 《Biomicrofluidics》2012,6(2):24103-2410310
A novel microfluidic device enabling selective generation of droplets and encapsulation of targets is presented. Unlike conventional methods, the presented mechanism generates droplets with unique selectivity by utilizing a K-junction design. The K-junction is a modified version of the classic T-junction with an added leg that serves as the exit channel for waste. The dispersed phase fluid enters from one diagonal of the K and exits the other diagonal while the continuous phase travels in the straight leg of the K. The intersection forms an interface that allows the dispersed phase to be controllably injected through actuation of an elastomer membrane located above the inlet channel near the interface. We have characterized two critical components in controlling the droplet size-membrane actuation pressure and timing as well as identified the region of fluid in which the droplet will be formed. This scheme will have applications in fluid sampling processes and selective encapsulation of materials. Selective encapsulation of a single cell from the dispersed phase fluid is demonstrated as an example of functionality of this design.  相似文献   

14.
A new microfluidic device with liquid-droplet merging and droplet storage functions for the controlled release of drugs from microcapsules is reported. A switching channel is designed and integrated within the microfluidic device, facilitating the generation and capturing of uniform droplets by the storage chambers. The drug model is the MnCO3 microparticle, which is encapsulated by a microcapsule and fabricated using a simple layer-by-layer nanoassembly process. The merging function is used for dynamically adding the control solution into the droplets, which contain drugs within the microcapsules (DWμCs) and water. The storage chambers are used for collecting DWμCs-laden droplets so that the controlled-drug release in specific droplets can be monitored for an extended period of time, which has been experimentally implemented successfully. This technology could offer a promising technical platform for the long-term observation and studies of drug effects on specific cells in a controlled manner, which is especially useful for single cell analysis.  相似文献   

15.
We present a droplet-based microfluidic system for performing bioassays requiring controlled analyte encapsulation by employing highly flexible on-demand droplet generation. On-demand droplet generation and encapsulation are achieved pneumatically using a microdispensing pump connected to a constant pressure source. The system generates single droplets to the collection route only when the pump is actuated with a designated pressure level and produces two-phase parallel flow to the waste route during the stand-by state. We analyzed the effect of actuation pressure on the stability and size of droplets and optimized conditions for generation of stable droplets over a wide pressure range. By increasing the duration of pump actuation, we could either trigger a short train of identical size droplets or generate a single larger droplet. We also investigated the methodology to control droplet contents by fine-tuning flow rates or implementing a resistance bridge between the pump and main channels. We demonstrated the integrated chip for on-demand mixing between two aqueous phases in droplets and on-demand encapsulation of Escherichia coli cells. Our unique on-demand feature for selective encapsulation is particularly appropriate for bioassays with extremely dilute samples, such as pathogens in a clinical sample, since it can significantly reduce the number of empty droplets that impede droplet collection and subsequent data analysis.  相似文献   

16.
A new ultra-high-throughput screening assay for the detection of cellulase activity was developed based on microfluidic sorting. Cellulase activity is detected using a series of coupled enzymes leading to the formation of a fluorescent product that can be detected on a chip. Using this method, we have achieved up to 300-fold enrichments of the active population of cells and greater than 90% purity after just one sorting round. In addition, we proved that we can sort the cellulase-expressing cells from mixtures containing less than 1% active cells.Cellulases are important enzymes with numerous applications across multiple industries, including biofuel, pulp, paper, textile and laundry, food, feed, brewing, and agriculture.1 Most cellulases have low activity and stability, so improving these properties would have substantial impact on numerous industrial processes.Enzymatic properties can be improved by protein engineering2 but the limiting step is the screening process. Classical screening uses microtiter plates (MTPs), where each well contains cells expressing a single type of mutant enzyme. However, this type of screening is the bottleneck in directed evolution, because a maximum number of 105 clones can be screened over the course of weeks or even months3 and large quantities of reagents and consumables are needed. High-throughput screening methods based on either fluorescence activated cell sorting (FACS)4–7 or microfluidic devices8 increase the number of clones that can be screened and reduce the amount of consumables required. Here, we demonstrate the use of a high-throughput screening system for cellulases by combining lab-on-chip sorting devices with an emulsion-based fluorescent assay previously developed for use in flow cytometry.5Water–in-oil emulsions are needed to maintain the connection between genotype and phenotype by compartmentalizing individual cells expressing a mutant enzyme together with the components of the fluorescence assay corresponding to the enzyme activity.7 For FACS, double emulsions (water-in-oil-in-water) are required because the instrument''s mobile phase is an aqueous solution. Such double emulsions can be produced by stirring or agitation,9,10 but the resulting emulsions are polydisperse and multiple water droplets may be scattered within a single oil droplet. In addition, large droplets tend to produce more fluorescence because there are more substrate molecules available for conversion into the fluorescent product. The emulsions are produced in bulk, so each droplet will be detected at a different time point from the start of the reaction. This means that increased fluorescence may result because an enzyme has worked on the substrate for a longer amount of time, and the fluorescence of the droplet may plateau before sorting as the enzyme consumes all the available substrate. Cell loading is difficult to control because the average number of cells per droplet scales with droplet volume. Also, if several inner droplets, containing cells with different activities, are encapsulated within the same outer droplet, false positives may occur upon sorting. Consequently, it is impossible to differentiate fluorescence changes due to enzyme activity from those due to other effects using polydisperse double emulsions in FACS, but it is possible to achieve plus/minus screening,4 separating cells with activity from those without.Droplet microfluidics overcomes many of the drawbacks of high-throughput enzyme sorting with FACS. Both the size and composition of the droplets can be tuned precisely. Furthermore, once the enzyme is mixed with the substrate, the incubation time can be controlled and all compartments will have the same conditions in terms of concentration and total number of substrate molecules. Although cell loading is still subject to Poisson statistics, the probability for cells to be loaded into a given droplet is the same and can be adjusted by tuning the input cell density. These characteristics make the microfluidic method more sensitive, flexible, and quantitative at detecting changes in enzyme activity than the FACS-based sorting of double emulsions.Here, we report a method in which droplet microfluidics is used to sort libraries containing different percentages of cells expressing cellulase activity and demonstrate enrichment of the cells expressing active cellulases. The entire process is summarized in Figure Figure11.Open in a separate windowFIG. 1.General overview of cellulase screening using droplet microfluidics. In the emulsification device, suspensions of yeast surface displayed libraries are co-flowed with the substrate solution at equal flow rates to a drop-forming junction where they mix. A stream of perfluorinated oil then breaks the aqueous mixture into monodisperse water-in-oil emulsions. Within each droplet, the cellulase reaction starts after compartmentalization and the fluorescent product is formed by a coupled enzymatic cascade in droplets containing cells that express the active enzyme. After a fixed incubation time, the emulsion droplets are re-injected into a microfluidic sorting device, where they are analyzed and sorted based on their fluorescence.To detect cellulase activity, we designed an assay that uses a chain of coupled enzymatic reactions to yield fluorescence corresponding to cellulase activity without needing artificial substrates (which may lead to confounding effects, such as improved binding of the enzyme specifically to the artificial compound but not the natural substrate). In this method, cellulase hydrolyzes cellulose, its natural substrate, into monosaccharides and oligosaccharides that are further detected by the enzymatic cascade5 (Figure (Figure11).Based on previous FACS experiments, no difference in activity can be detected between the positive and the negative droplets before 2 h incubation time.5 Based on these observations, we expected the cells to require more than 2 h of incubation in droplets for the reaction to develop.Emulsions were formed using a co-flow flow-focusing Polydimethylsiloxane device prepared by soft lithography as previously described8 and using fluorocarbon oil containing 1% (v/v) Krytox-PEG-Krytox detergent synthesized as reported in an earlier study.11,14 The solutions, one containing library cells (S. cerevisiae YPH500 cells, Agilent Technologies, Santa Clara, USA) and the other with the substrate,14 were mixed at the same flow rate, giving a one-to-one mixing ratio. The library cells were a defined mixture of cells transformed with cel5A pESC-Trp (positive cells) or empty pESC-Trp (negative cells). The two solutions therefore mixed just prior to encapsulation, minimizing the chance that fluorescent products would enter neighboring droplets. The substrate solution contained carboxymethyl cellulose (CMC), which has a high viscosity. To prevent fluctuations in the flow of substrate during the emulsification process, we optimized the flow rate and the concentration of CMC and found that a CMC concentration of 0.33% (w/v) produced monodisperse emulsions.We discovered that the HOx required for the enzymatic cascade causes droplet coalescence. HOx alone was sufficient to cause the observed change in droplet stability because droplets containing only hexose oxidase in buffer exhibited the same amount of coalescence as those containing the full set of assay components. We hypothesized that the enzyme might be surface active, disturbing the emulsion interface, but emulsions of an inactivated form of the enzyme were stable (Figure 2(a)). One possible explanation is that active HOx may interact with the detergent through the active site. Adding bovine serum albumin (BSA), which is known to have a stabilizing effect,12 to the mixture improved droplet stability (Figure 2(a)). Emulsions of the assay mixture with BSA were stable for more than 1 day at room temperature.Open in a separate windowFIG. 2.(a) Transmission light micrographs of water-in-perfluorinated-oil emulsions produced using the microfluidic emulsification devices after 2 h incubation at room temperature. The emulsions contain 3 U/ml HOx either in its native form (left image), inactivated by heating at 99 °C for 20 min (middle image), or supplemented with 1 mg/ml BSA (right image). (b) Images of the results of the agar plate Congo Red cellulase assay before and after sorting, with the percentage of positive colonies indicated. The cells expressing cellulase activity show clear hallos.The time required for the cellulase reaction to produce detectable quantities of fluorescent product was monitored using the droplet screening instrument. These devices proved to have a higher sensitivity than the FACS system because the optics are designed for the droplet size selected for the assay. We were able to detect cellulase activity just 20 min after the compartmentalization of cells. This shorter incubation time allowed us to couple the emulsification device directly to the droplet sorting device using a short piece of tubing. The rate of emulsion flow and the dimensions of the tube set the droplet incubation time.Using the optimized conditions, we used droplet microfluidics to sort cellulase-expressing cells from a set of reference libraries. The reference libraries were created by mixing different concentrations of positive S. cerevisiae YPH500 cells expressing Cel5A cellulase and negative S. cerevisiae YPH500 cells transformed with the pESC-Trp empty vector. The mixed populations were emulsified together with the assay components in water-in-perfluorinated-oil emulsions and incubated at room temperature for 20 min. The gated population was sorted and the cells were spread on yeast nitrogen base casaminoacids (YNB CAA) Glu agar plates. An aliquot of the reference library was also plated on agar plates prior to sorting. Approximately, 100 cells before and after sorting were transferred to YNB CAA CMC Gal/Raf induction plates, and the Congo red assay13 was used to detect cells expressing cellulase. In this assay, colonies of positive cells developed transparent halos around them.14 The results before and after sorting are presented in Figure 2(b).We enriched cellulase-expressing cells from a pool of negative cells, regardless of the starting concentration of positive cells. We were able to isolate the cellulase-expressing cells even when starting from a low percentage of active cells (0.1%). We obtained high enrichment factors of up to 300 when starting from low concentrations of positive cells, and we were able to sort to a purity of greater than 90%. These results exceed those obtained by comparable experiments using FACS.5In conclusion, we developed a high-throughput screening system for cellulase activity based on droplet microfluidics. We optimized the emulsification conditions to produce highly stable and monodisperse droplets. The low dispersity of the emulsion enables the sensitive, tunable, and quantitative detection of cellulase activity. In addition, we substantially reduced the reaction time needed for the development of a fluorescent product from 2 h to 20 min. As a result, we sorted reference libraries of cellulases with various ratios of positive to negative cells, and regardless of the starting population of positive cells we were always able to enrich the active population to a higher purity than that obtained by FACS.  相似文献   

17.
Lee DH  Lee W  Um E  Park JK 《Biomicrofluidics》2011,5(3):34117-341179
Precise temporal control of microfluidic droplets such as synchronization and combinatorial pairing of droplets is required to achieve a variety range of chemical and biochemical reactions inside microfluidic networks. Here, we present a facile and robust microfluidic platform enabling uniform interval control of flowing droplets for the precise temporal synchronization and pairing of picoliter droplets with a reagent. By incorporating microbridge structures interconnecting the droplet-carrying channel and the flow control channel, a fluidic pressure drop was derived between the two fluidic channels via the microbridge structures, reordering flowing droplets with a defined uniform interval. Through the adjustment of the control oil flow rate, the droplet intervals were flexibly and precisely adjustable. With this mechanism of droplet spacing, the gelation of the alginate droplets as well as control of the droplet interval was simultaneously achieved by additional control oil flow including calcified oleic acid. In addition, by parallel linking identical microfluidic modules with distinct sample inlet, controlled synchronization and pairing of two distinct droplets were demonstrated. This method is applicable to facilitate and develop many droplet-based microfluidic applications, including biological assay, combinatorial synthesis, and high-throughput screening.  相似文献   

18.
Simon MG  Lin R  Fisher JS  Lee AP 《Biomicrofluidics》2012,6(1):14110-1411013
Here, we present a microfluidic droplet trap that takes advantage of the net Laplace pressure force generated when a droplet is differentially constricted. Mathematical simulations were first used to understand the working range of the component; followed by finite element modeling using the CFD software package to further characterize the behavior of the system. Controlled release of the trapped droplets is also demonstrated through both a mechanical method and a chemical method that manipulates the total pressure exerted on the trapped droplet. The unique design of this trapping device also provides the capability for selection of a single droplet from a train, as well as droplet fusion.  相似文献   

19.
We present dual-mode, on-demand droplet routing in a multiple-outlet microfluidic device using an oil-based magnetic fluid. Magnetite (Fe3O4) nanoparticle-contained oleic acid (MNOA) was used as a carrier phase for droplet generation and manipulation. The water-in-MNOA droplets were selectively distributed in a curved microchannel with three branches by utilizing both a hydrodynamic laminar flow pattern and an external magnetic field. Without the applied magnetic field, the droplets travelled along a hydrodynamic centerline that was displaced at each bifurcating junction. However, in the presence of a permanent magnet, they were repelled from the centerline and diverted into the desired channel when the repelled distance exceeded the minimum offset allocated to the channel. The repelled distance, which is proportional to the magnetic field gradient, was manipulated by controlling the magnet''s distance from the device. To evaluate routing performance, three different sizes of droplets with diameters of 63, 88, and 102 μm were directed into designated outlets with the magnet positioned at varying distances. The result demonstrated that the 102-μm droplets were sorted with an accuracy of ∼93%. Our technique enables on-demand droplet routing in multiple outlet channels by simply manipulating magnet positions (active mode) as well as size-based droplet separation with a fixed magnet position (passive mode).  相似文献   

20.
Droplet microfluidics is a powerful method used to characterize chemical reactions at high throughput. Often detection is performed via in-line optical readout, which puts high demands on the detection system or makes detection of low concentration substrates challenging. Here, we have developed a droplet acoustofluidic chip for time-controlled reactions that can be combined with off-line optical readout. The principle of the platform is demonstrated by the enzymatic conversion of fluorescein diphosphate to fluorescein by alkaline phosphatase. The novelty of this work is that the time of the enzymatic reaction is controlled by physically removing the enzymes from the droplets instead of using chemical inhibitors. This is advantageous as inhibitors could potentially interact with the readout. Droplets containing substrate were generated on the chip, and enzyme-coupled microbeads were added into the droplets via pico-injection. The reaction starts as soon as the enzyme/bead complexes are added, and the reaction is stopped when the microbeads are removed from the droplets at a channel bifurcation. The encapsulated microbeads were focused in the droplets by acoustophoresis during the split, leaving the product in the side daughter droplet to be collected for the analysis (without beads). The time of the reaction was controlled by using different outlets, positioned at different lengths from the pico-injector. The enzymatic conversion could be measured with fluorescence readout in a separate PDMS based assay chip. We show the ability to perform time-controlled enzymatic assays in droplet microfluidics coupled to an off-line optical readout, without the need of enzyme inhibitors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号