首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
IntroductionFollowing a pandemic, laboratory medicine is vulnerable to laboratory errors due to the stressful and high workloads. We aimed to examine how laboratory errors may arise from factors, e.g., flexible working order, staff displacement, changes in the number of tests, and samples will reflect on the total test process (TTP) during the pandemic period.Materials and methodsIn 12 months, 6 months before and during the pandemic, laboratory errors were assessed via quality indicators (QIs) related to TTP phases. QIs were grouped as pre-, intra- and postanalytical. The results of QIs were expressed in defect percentages and sigma, evaluated with 3 levels of performance quality: 25th, 50th and 75th percentile values.ResultsWhen the pre- and during pandemic periods were compared, the sigma value of the samples not received was significantly lower in pre-pandemic group than during pandemic group (4.7σ vs. 5.4σ, P = 0.003). The sigma values of samples transported inappropriately and haemolysed samples were significantly higher in pre-pandemic period than during pandemic (5.0σ vs. 4.9σ, 4.3σ vs. 4.1σ; P = 0.046 and P = 0.044, respectively). Sigma value of tests with inappropriate IQC performances was lower during pandemic compared to the pre-pandemic period (3.3σ vs. 3.2σ, P = 0.081). Sigma value of the reports delivered outside the specified time was higher during pandemic than pre-pandemic period (3.0σ vs. 3.1σ, P = 0.030).ConclusionIn all TTP phases, some quality indicators improved while others regressed during the pandemic period. It was observed that preanalytical phase was affected more by the pandemic.  相似文献   

2.

Introduction

The educational program for health care personnel is important for reducing preanalytical errors and improving quality of laboratory test results. The aim of our study was to assess the level of knowledge on preanalytical phase in population of biomedicine students through a cross-sectional survey.

Materials and methods

A survey was sent to students on penultimate and final year of Faculty of Pharmacy and Biochemistry – study of medical biochemistry (FPB), Faculty of Veterinary Medicine (FVM) and School of Medicine (SM), University of Zagreb, Croatia, using the web tool SurveyMonkey. Survey was composed of demographics and 14 statements regarding the preanalytical phase of laboratory testing. Comparison of frequencies and proportions of correct answers was done with Fisher’s exact test and test of comparison of proportions, respectively.

Results

Study included 135 participants, median age 24 (23-40) years. Students from FPB had higher proportion of correct answers (86%) compared to students from other biomedical faculties 62%, P < 0.001. Students from FPB were more conscious of the importance of specimen mixing (P = 0.027), prevalence of preanalytical errors (P = 0.001), impact of hemolysis (P = 0.032) and lipemia interferences (P = 0.010), proper choice of anticoagulants (P = 0.001), transport conditions for ammonia sample (P < 0.001) and order of draw during blood specimen collection (P < 0.001), in comparison with students from SM and FVM.

Conclusions

Students from FPB are more conscious of the importance of preanalytical phase of testing in comparison with their colleagues from other biomedical faculties. No difference in knowledge between penultimate and final year of the same faculty was found.Key words: survey, education, preanalytical phase  相似文献   

3.

Introduction

Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC).

Materials and methods

We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square.

Results

There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients.

Conclusion

We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system.Key words: Preanalytical phase, errors in laboratory medicine, balanced scorecard, patient safety  相似文献   

4.

Introduction:

Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory.

Materials and methods:

This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors.

Results:

A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients.

Conclusions:

The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.  相似文献   

5.

Introduction

Preanalytical specifications for urinalysis must be strictly adhered to avoid false interpretations. Aim of the present study is to examine whether the preanalytical factor ‘time point of analysis’ significantly influences stability of urine samples for urine particle and dipstick analysis.

Materials and methods

In 321 pathological spontaneous urine samples, urine dipstick (Urisys™2400, Combur-10-Test™strips, Roche Diagnostics, Mannheim, Germany) and particle analysis (UF-1000 i™, Sysmex, Norderstedt, Germany) were performed within 90 min, 120 min and 240 min after urine collection.

Results

For urine particle analysis, a significant increase in conductivity (120 vs. 90 min: P < 0.001, 240 vs. 90 min: P < 0.001) and a significant decrease in WBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), RBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), casts (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and epithelial cells (120 vs. 90 min P = 0.610, 240 vs. 90 min P = 0.041) were found. There were no significant changes for bacteria. Regarding urine dipstick analysis, misclassification rates between measurements were significant for pH (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), leukocytes (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), nitrite (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), protein (120 vs. 90 min P < 0.001, 240 vs. 90 min P<0.001), ketone (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), blood (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), specific gravity (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and urobilinogen (120 vs. 90 min, P = 0.031). Misclassification rates were not significant for glucose and bilirubin.

Conclusion

Most parameters critically depend on the time window between sampling and analysis. Our study stresses the importance of adherence to early time points in urinalysis (within 90 min).Key words: urinalysis, automation, analytical sample preparation methods, flow cytometry, specimen handling  相似文献   

6.

Background

Due to the high prevalence of hemolysis in specimens received from the emergency department (ED), several strategies have been proposed to improve sample quality, but none of these seem effective to overcome the problem. In a preliminary study we showed that the use of S-Monovette blood collection system was effective to lower the risk of hemolysis in venous blood samples collected from intravenous catheters. This study was hence aimed to verify whether the replacement of a conventional vacuum system with S-Monovette may be effective to reduce the burden of hemolysis in the daily practice of a large urban ED.

Materials and methods

The study was divided in two observational periods of 4 months each. In the former period, blood was collected from intravenous catheters using BD Vacutainer SST II Plus plastic serum tubes, whereas in the latter period the blood was drawn from intravenous catheters using S-Monovette blood tubes in aspiration mode. Sample hemolysis was automatically assessed in all serum samples by photometrical measurement.

Results

The total number of hemolysed serum specimens was 624/14155 (4.41%) in the first phase of the study, and 342/13319 (2.57%) in the second phase of the study (P < 0.001).

Conclusion

Results of our study confirm that the introduction of the Sarstedt S-Monovette blood tubes has reduced the hemolysis rate in the emergency department compared to the previously used BD Vacutainer® SST II Plus plastic serum tubes.Key words: preanalytical phase, hemolysis, blood specimen collection, catheter, emergency department  相似文献   

7.

Introduction

The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas.

Materials and methods

The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected.

Results

Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics.

Conclusions

We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety.Key words: clinical laboratory services, total quality management, patient safety, preanalytical phase, preanalytical error  相似文献   

8.

Introduction

Centrifugation is an essential step for plasma preparation to remove residual elements in plasma, especially platelets and platelet-derived microparticles (PMPs). Our working hypothesis was that centrifugation as a preanalytical step may influence some coagulation parameters.

Materials and methods

Healthy young men were recruited (N = 17). For centrifugation, two protocols were applied: (A) the first centrifugation at 2500 x g for 15 min and (B) at 2500 x g for 20 min at room temperature with a light brake. In protocol (A), the second centrifugation was carried out at 2500 x g for 15 min, whereas in protocol (B), the second centrifugation involved a 10 min spin at 13,000 x g. Thrombin-antithrombin (TAT) and plasmin-antiplasmin (PAP) complexes concentrations were determined by enzyme-linked immunosorbent assays. PMPs were stained with CD41 antibody and annexin V, and analyzed by flow cytometry method. Procoagulant activity was assayed by the Calibrated Automated Thrombogram method as a slope of thrombin formation (CAT velocity).

Results

Median TAT and PAP concentrations did not differ between the centrifugation protocols. The high speed centrifugation reduced the median (IQR) PMP count in plasma from 1291 (841-1975) to 573 (391-1010) PMP/µL (P = 0.001), and CAT velocity from 2.01 (1.31-2.88) to 0.97 (0.82-1.73) nM/min (P = 0.049). Spearman’s rank correlation analysis showed correlation between TAT and PMPs in the protocol A plasma which was (rho = 0.52, P < 0.050) and between PMPs and CAT for protocol A (rho = 0.74, P < 0.050) and protocol B (rho = 0.78, P < 0.050).

Conclusion

Centrifugation protocols do not influence the markers of plasminogen (PAP) and thrombin (TAT) generation but they do affect the PMP count and procoagulant activity.Key words: cell-derived microparticles, blood coagulation tests, centrifugation, preanalytical phase  相似文献   

9.

Introduction:

Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer® Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer® RST blood collection tube in reference with the BD Vacutainer® Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA).

Materials and methods:

Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality.

Results:

Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C.

Conclusions:

Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.  相似文献   

10.
IntroductionKidney stone formers can have higher oxalate and phosphate salt amounts in their urine than healthy people and we hypothesized that its acidification may be useful. The study aims to compare results of urine concentrations of calcium, magnesium, and inorganic phosphorus in the midstream portion of first voided morning urine samples without (FMU) and with post-collection acidification (FMUa) in kidney stone patients.Materials and methodsThis is a prospective single center study. A total of 138 kidney stone patients with spot urine samples were included in the study. Urine concentrations of calcium, magnesium and inorganic phosphorus were measured with and without post-collection acidification. Acidification was performed by adding 5 µL of 6 mol/L HCl to 1 mL of urine.ResultsThe median age (range) of all participants was 56 (18-87) years. The median paired differences between FMU and FMUa concentrations of calcium, magnesium, and inorganic phosphorus were: - 0.040 mmol/L, 0.035 mmol/L, and 0.060 mmol/L, respectively. They were statistically different: P < 0.001, P < 0.001, P = 0.004, respectively. These differences are not clinically significant because biological variations of these markers are much higher.ConclusionsNo clinically significant differences in urinary calcium, magnesium, and inorganic phosphorus concentrations between FMU and FMUa in patients with kidney stones were found.  相似文献   

11.
IntroductionBased on the hypothesis that there is a substantial rate of adults with prediabetes and undiagnosed diabetes mellitus (DM), our aim was to perform haemoglobin A1c (HbA1c)-based screening in a cohort of Croatian adults and estimate the prevalence of prediabetes and undiagnosed DM according to American Diabetes Association criteria.Materials and methodsThis multi-center, cross-sectional study performed in six Croatian hospitals included 5527 patients aged 40 to 70 years admitted to the Emergency Department or undergoing a primary care check-up. Haemoglobin A1c was measured from leftover whole blood samples using the enzymatic method on either Alinity c or Architect c-series analyser (Abbott Laboratories, Chicago, USA). Haemoglobin A1c between 39-47 mmol/mol was classified as prediabetes, while ≥ 48 mmol/mol as undiagnosed DM.ResultsAfter exclusion of 435 patients with known DM, the final cohort included 5092 patients (median age 57; 56% males). A total of 882 (17.3%) patients had HbA1c values between 39 and 47 mmol/mol. There were 214 (4.2%) patients with HbA1c ≥ 48 mmol/mol. Prediabetes prevalence ranged from 14.2% to 20.5%, while undiagnosed DM from 3.3% to 7.3%, with statistically significant differences among settings (P < 0.001). Age-stratified analysis showed that prediabetes and undiagnosed DM prevalence increase with age (P < 0.001), being 25.4% and 5.8%, respectively, in patients aged 60 to 70 years.ConclusionUnderlying impairment of glucose metabolism was identified in about one in five adults, with significant number of patients with already overt DM. These results should serve as a starting point for further steps directed towards promotion of preventive measures for DM in Croatia.  相似文献   

12.

Introduction

Measurements of blood ethanol concentrations must be accurate and reliable. The most important factors affecting blood ethanol stability are temperature and storage time. In this study, we aimed to compare ethanol stability in plasma samples at -20 °C for the different storage periods.

Materials and methods

Blood samples were collected from intoxicated drivers (N = 80) and initial plasma ethanol concentrations were measured immediately. Plasma samples were then stored at -20 °C and re-assessed after 2, 3, 4, or 5 months of storage. Differences between the initial and stored ethanol concentrations in each group (N = 20) were analyzed using Wilcoxon matched-pairs test. The deviation from the initial concentration was calculated and compared with Clinical Laboratory Improvement Amendments (CLIA’88) Proficiency Testing Limits. Relationships between the initial concentrations and deviations from initial concentrations were analyzed by Spearman’s correlation analysis. For all statistical tests, differences with P values of less than 0.05 were considered statistically significant.

Results

Statistically significant differences were observed between the initial and poststorage ethanol concentrations in the overall sample group (P < 0.001). However, for the individual storage duration groups, analytically significant decreases were observed only for samples stored for 5 months, deviations from the initial concentrations exceeded the allowable total error (TEa). Ethanol decreases in the other groups did not exceed the TEa.

Conclusion

According to our results, plasma ethanol samples can be kept at -20 °C for up to 3-4 months until re-analysis. However, each laboratory should also establish its own work-flow rules and criterion for reliable ethanol measurement in forensic cases.Key words: preanalytical phase, ethanol, stability, storage temperature  相似文献   

13.

Introduction

The aim of our study was to investigate the extent to which Instructions to authors of the Croatian open access (OA) journals are addressing ethical issues. Do biomedical journals differ from the journals from other disciplines in that respect? Our hypothesis was that biomedical journals maintain much higher publication ethics standards.

Materials and methods

This study looked at 197 Croatian OA journals Instructions to authors to address the following groups of ethical issues: general terms; guidelines and recommendations; research approval and registration; funding and conflict of interest; peer review; redundant publications, misconduct and retraction; copyright; timeliness; authorship; and data accessibility. We further compared a subset of 159 non-biomedical journals with a subset of 38 biomedical journals. Content analysis was used to discern the ethical issues representation in the instructions to authors.

Results

The groups of biomedical and non-biomedical journals were similar in terms of originality (χ2 = 2.183, P = 0.140), peer review process (χ2 = 0.296, P = 0.586), patent/grant statement (χ2 = 2.184, P = 0.141), and timeliness of publication (χ2 = 0.369, P = 0.544). We identified significant differences among categories including ethical issues typical for the field of biomedicine, like patients (χ2 = 47.111, P < 0.001), and use of experimental animals (χ2 = 42.543, P < 0.001). Biomedical journals also rely on international editorial guidelines formulated by relevant professional organizations heavily, compared with non-biomedical journals (χ2 = 42.666, P < 0.001).

Conclusion

Low representation or absence of some key ethical issues in author guidelines calls for more attention to the structure and the content of Instructions to authors in Croatian OA journals.Key words: instructions to authors, publication ethics, publication standards, open access, OA, research integrity  相似文献   

14.
Preanalytical errors contribute to a large proportion of total laboratory errors. In order to achieve continuous laboratory improvement, it is important to focus on all phases of patient specimen testing i.e. preanalytical, analytical and post-analytical. With large variations in the way venous blood specimens are collected using diverse devices in the country, the effect of such practices on specimen quality is not known. The purpose of this study was to monitor fourteen specimen preanalytical quality indicators in order to compare the usage of evacuated blood collection devices with needle and syringe open collection using either disposable tubes or re-washed glass vials. The study involved 26638 patient specimens assessed over a period of 6 months. The results demonstrated that evacuated closed blood collection resulted in an approximate 100-fold reduction in the incidence of hemolysis in samples. Similarly, there was a 200-fold reduction in incidence of insufficient specimen quantity while using evacuated collection system. It was also found that incidence of specimen contamination, improper volume of sample collected, and specimen spillage was also lower when the evacuated collection system was used. Further, it was also observed that the facility with a laboratory information system demonstrated much lower specimen identification and related errors. The observed results clearly demonstrate that the usage of the evacuated blood collection system resulted in improvement of preanalytical specimen quality as compared to needle and syringe usage.  相似文献   

15.
IntroductionSeveral laboratory tests are characteristically altered in Coronavirus Disease 2019 (COVID-19), but are not totally accurate in predicting the disease outcome. The long pentraxin 3 (PTX3) is quickly released directly at inflammation sites by many immune cell types. Previous studies have shown that PTX3 correlated with disease severity in various inflammatory conditions. Our study investigated the use of PTX3 as a potential marker of COVID-19 severity and compared its performance in detecting a more severe form of the disease with that of routine laboratory parameters.Materials and methodsStored serum samples of RT-PCR confirmed COVID-19 cases that had been obtained at hospital admission were retrospectively analysed. Intensive care unit (ICU) stay was considered a surrogate endpoint of severe COVID-19. Pentraxin 3 was measured by a commercial enzyme-linked immunosorbent assay.ResultsA total of 96 patients were recruited from May 1st, 2020 to June 30th, 2020; 75/96 were transferred to ICU. Pentraxin 3 was higher in ICU vs non-ICU patients (35.86 vs 10.61 ng/mL, P < 0.001). Univariate and multivariate logistic regression models demonstrated that the only significant laboratory predictor of ICU stay was PTX3 (OR: 1.68 (1.19-2.29), P = 0.003), after controlling for comorbidities. The Receiver Operator Characteristic curve analysis showed that PTX3 had a higher accuracy compared to C-reactive protein (CRP), lactate dehydrogenase (LD), ferritin in identifying ICU patients (AUC of PTX3 = 0.98; CRP = 0.66; LD = 0.70; ferritin = 0.67, P < 0.001). A cut-off of PTX3 > 18 ng/mL yielded a sensitivity of 96% and a specificity of 100% in identifying patients requiring ICU.ConclusionHigh values of PTX3 predict a more severe COVID-19.  相似文献   

16.

Background

In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.

Material and methods

Data were collected from 319 patients admitted to the emergency department of a cardiology hospital from January–July 2014. EDTA blood samples drawn at admission were analyzed using automated hematology system, and BNP concentration was measured using a fluorescence immunoassay.

Results

The study included 190 patients with and 129 without acute heart failure (AHF). These groups had BNP concentration of 200-5000 ng/L and 5-98 ng/L, respectively. MPV levels were significantly higher in the AHF group (P < 0.001). BNP concentrations were positively correlated with MPV (r = 0.41, P < 0.001) and neutrophil / lymphocyte ratio (r = 0.38, P < 0.001).

Conclusion

Increased MPV values correlate with BNP concentration, an indicator of HF severity and clinical status, in patients with AHF admitted to the emergency department.Key words: natriuretic peptide, brain; heart failure; platelet; mean platelet volume  相似文献   

17.

Introduction:

The phlebotomists’ procedures are a still source of laboratory variability. The aim of this study was to verify the efficacy of minor modification in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document is able to reduce the tourniquet application time.

Materials and methods:

Thirty phlebotomists were invited to participate. Each phlebotomist was trained individually to perform the new venipuncture procedure that shortens the time of tourniquet release and removal. The phlebotomy training program was delivered over 8h. After training, all phlebotomists were monitored for 20 working days, to guarantee the adoption of the correct new procedures for collection of diagnostic blood specimens. After this time frame the phlebotomists were evaluated to verify whether the new procedure for blood collection derived from CLSI H03-A6 document was effective to improve the quality process by decrease in tourniquet application time. We compared the tourniquet application time and qualitative difference of phlebotomy procedures between laboratories before and after phlebotomy training.

Results:

The overall mean ± SD tourniquet application time before and after this intervention were 118 ± 1 s and 30 ± 1 s respectively. Minor modifications in procedure for blood collection were able to reduce significantly the tourniquet application time (−88 s, P < 0.001).

Conclusions:

The minor modifications in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document were able to reduce the tourniquet application time. Now the proposed new procedure for collection of diagnostic blood specimens by venipuncture could be considered usefulness and should be put into practice by all quality laboratory managers and/or phlebotomy coordinators to avoid preanalytical errors regard venous stasis and guarantee patient safety.  相似文献   

18.
Activated carbon fabrics (ACF) mask prevents the absorption of lead and reduce its adverse effects of human health. Aim of this study to know the blood lead level and its effects on heme biosynthesis and hematological parameters after using 2 months activated carbon fabric mask of battery manufacturing workers (BMW). Blood lead level, heme biosynthesis and hematological parameters were measured by using standard method. Blood lead level (P < 0.001, − 13.5%) was significantly decreased, activated δ-aminolevulinic acid dehydratase (P < 0.001, 11.97%) and non-activated δ- aminolevulinic acid dehydratase (P < 0.001, 23.17%) enzyme activity were significantly increased, however, the ratio of activated to Non-activated δ- ALAD (P < 0.001, − 10.13%) was significantly decreased, urinary excretion of δ- aminolevulinic acid (P < 0.001, − 10.49%) and porphobilinogen (P < 0.001, − 7.38%) were significantly decreased after using 2 months ACF mask as compared to before using mask of BMW. Hematological parameters i.e Hb (P < 0.05, 13.42%), PCV (P < 0.05, 7.23%), MCV (P < 0.05, 1.9%) were significantly increased and total WBC count (P < 0.05, − 5.18%) was significantly decreased after using 2 months ACF mask as compared to before using mask of BMW. Two months using ACF mask reduces the blood lead level and improves the δ-ALDH activity and hematological parameters, decreases the urinary excretion of δ-ALA, PBG of battery manufacturing workers. Therefore, the regular using of ACF mask is beneficial to prevent the lead absorption and its adverse effects on human health.  相似文献   

19.

Introduction

Extremely high glucose concentrations have been shown to interfere with creatinine assays especially with Jaffe method in peritoneal dialysate. Because diabetes is the fastest growing chronic disease in the world, laboratories study with varying glucose concentrations. We investigated whether different levels of glucose spiked in serum interfere with 21 routine chemistry and thyroid assays at glucose concentrations between 17-51 mmol/L.

Materials and methods

Baseline (group I) serum pool with glucose concentration of 5.55 (5.44-5.61) mmol/L was prepared from patient sera. Spiking with 20% dextrose solution, sample groups were obtained with glucose concentrations: 17.09, 34.52, and 50.95 mmol/L (group II, III, IV, respectively). Total of 21 biochemistry analytes and thyroid tests were studied on Abbott c8000 and i2000sr with commercial reagents. Bias from baseline value was checked statistically and clinically.

Results

Creatinine increased significantly by 8.74%, 31.66%, 55.31% at groups II, III, IV, respectively with P values of < 0.001. At the median glucose concentration of 50.95 mmol/L, calcium, albumin, chloride and FT4 biased significantly clinically (-0.85%, 1.63%, 0.65%, 7.4% with P values 0.138, 0.214, 0.004, < 0.001, respectively). Remaining assays were free of interference.

Conclusion

Among the numerous biochemical parameters studied, only a few parameters are affected by dramatically increased glucose concentration. The creatinine measurements obtained in human sera with the Jaffe alkaline method at high glucose concentrations should be interpreted with caution. Other tests that were affected with extremely high glucose concentrations were calcium, albumin, chloride and FT4, hence results should be taken into consideration in patients with poor diabetic control.Key words: assay interference, glucose interference, preanalytical phase, creatinine, Jaffe kinetic assay, thyroid function tests  相似文献   

20.
IntroductionThe study aimed to investigate the prevalence and titres of anti-SARS-CoV-2 antibodies in children treated at the Children’s Hospital Zagreb in the first and the second wave of the COVID-19 pandemic. Statistical significance of difference at two time points was done to determine how restrictive epidemiological measures and exposure of children to COVID-19 infection affect this prevalence in different age groups.Materials and methodsAt the first time point (13th to 29th May 2020), 240 samples and in second time point (24th October to 23rd November 2020), 308 serum samples were tested for anti-SARS-CoV-2 antibodies by enzyme-linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA). Confirmation of results and titre determination was done using virus micro-neutralization test. Subjects were divided according to gender, age and epidemiological history.ResultsSeroprevalence of anti-SARS-CoV-2 antibodies differs significantly in two time points (P = 0.010). In first time point 2.9% of seropositive children were determined and in second time point 8.4%. Statistically significant difference (P = 0.007) of seroprevalence between two time points was found only in a group of children aged 11-19 years. At the first time point, all seropositive children were asymptomatic with titre < 8. At the second time point, 69.2% seropositive children were asymptomatic with titre ≥ 8.ConclusionsThe prevalence of anti-SARS-CoV-2 antibodies was significantly lower at the first time point than at the second time point. Values of virus micro-neutralization test showed that low titre in asymptomatic children was not protective at the first time point but in second time point all seropositive children had protective titre of anti-SARS-CoV-2 antibodies.  相似文献   