首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
2.
ABSTRACT

This project examined the interrelationships between power production and upper body kinematics during a series of medicine ball push-press (MBP-P) throws. Twenty-five regular weight trainers (body mass = 86 ± 10 kg) performed a series of ballistic vertical MBP-P throws at loads representing 5% and 10% of their assessed 5RM bench press. Throws were performed lying supine on a force platform (1 kHz) with upper body kinematics assessed using standard infra-red motion capture techniques (0.5 kHz). Gross measures of performance and power production such as peak vertical ball velocity (Velpeak), peak force (Fpeak) and power (Ppeak) were recorded during the propulsive phase of the movement. Comparative analyses indicated that despite significant reductions in Velpeak from the 5% to 10% loads (P < 0.001), Fpeak remained largely unchanged (P = 0.167). Analysis of inter-trial variability showed that the gross measures of performance and power were relatively stable (Coefficient of Variation [CV%] <13%), while most upper limb segmental kinematics varied considerably between trials (CV% up to 70%). This project highlights the complexity of the relationships between power production and upper body kinematics during light load ballistic MBP-P throwing. Additionally, it shows how trained athletes can achieve similar outcomes during ballistic movements using a variety of movement strategies.  相似文献   

3.
The purpose of this study was to assess validity and reliability of sprint performance outcomes measured with an iPhone application (named: MySprint) and existing field methods (i.e. timing photocells and radar gun). To do this, 12 highly trained male sprinters performed 6 maximal 40-m sprints during a single session which were simultaneously timed using 7 pairs of timing photocells, a radar gun and a newly developed iPhone app based on high-speed video recording. Several split times as well as mechanical outputs computed from the model proposed by Samozino et al. [(2015). A simple method for measuring power, force, velocity properties, and mechanical effectiveness in sprint running. Scandinavian Journal of Medicine & Science in Sports. https://doi.org/10.1111/sms.12490] were then measured by each system, and values were compared for validity and reliability purposes. First, there was an almost perfect correlation between the values of time for each split of the 40-m sprint measured with MySprint and the timing photocells (r?=?0.989–0.999, standard error of estimate?=?0.007–0.015?s, intraclass correlation coefficient (ICC)?=?1.0). Second, almost perfect associations were observed for the maximal theoretical horizontal force (F0), the maximal theoretical velocity (V0), the maximal power (Pmax) and the mechanical effectiveness (DRF – decrease in the ratio of force over acceleration) measured with the app and the radar gun (r?=?0.974–0.999, ICC?=?0.987–1.00). Finally, when analysing the performance outputs of the six different sprints of each athlete, almost identical levels of reliability were observed as revealed by the coefficient of variation (MySprint: CV?=?0.027–0.14%; reference systems: CV?=?0.028–0.11%). Results on the present study showed that sprint performance can be evaluated in a valid and reliable way using a novel iPhone app.  相似文献   

4.
ABSTRACT

This study aimed to compare mechanical variables derived from torque-cadence and power-cadence profiles established from different cycle ergometer modes (isoinertial and isokinetic) and modelling procedures (second- and third-order polynomials), whilst employing a novel method to validate the theoretical maximal power output (Pmax). Nineteen well-trained cyclists (n = 12 males) completed two experimental sessions comprising six, 6-s maximal isoinertial or isokinetic cycling sprints. Maximal pedal strokes were extracted to construct power–cadence relationships using second- and third-order polynomials. A 6-s sprint at the optimal cadence (Fopt) or optimal resistance (Topt) was performed to assess construct validity of Pmax. No differences were found in the mechanical parameters when derived from isokinetic (Pmax = 1311 ± 415, Fopt = 118 ± 12) or isoinertial modes (Pmax = 1320 ± 421, Fopt = 116 ± 19). However, R2 improved (P < 0.02) when derived from isoinertial sprints. Third-order polynomial modelling improved goodness of fit values (Standard Error, adjusted R2), but derived similar mechanical parameters. Finally, peak power output during the optimised sprint did not significantly differ from the theoretical Pmax in both cycling modes, thus providing construct validity. The most accurate P-C profile can be derived from isoinertial cycling sprints, modelled using third-order polynomial equations.  相似文献   

5.
Abstract

In this study, we examined the correlations between selected markers of isometric training intensity and subsequent reductions in resting blood pressure. Thirteen participants performed a discontinuous incremental isometric exercise test to volitional exhaustion at which point mean torque for the final 2-min stage (2min-torquepeak) and peak heart rate peak (HRpeak) were identified. Also, during 4 weeks of training (3 sessions per week, comprising 4 × 2 min bilateral leg isometric exercise at 95% HRpeak), heart rate (HRtrain), torque (Torquetrain), and changes in EMG amplitude (ΔEMGamp) and frequency (ΔEMGfreq) were determined. The markers of training intensity were: Torquetrain relative to the 2min-torquepeak (%2min-torquepeak), EMG relative to EMGpeak (%EMGpeak), HRtrain ΔEMGamp, ΔEMGfreq, and %MVC. Mean systolic (?4.9 mmHg) and arterial blood pressure (?2.7mmHg) reductions correlated with %2min-torquepeak (r = ?0.65, P = 0.02 and r = ?0.59, P = 0.03), ΔEMGamp (r = 0.66, P = 0.01 and r = 0.59, P = 0.03), ΔEMGfreq (r = ?0.67, P = 0.01 and r = ?0.64, P = 0.02), and %EMGpeak (systolic blood pressure only; r = ?0.63, P = 0.02). These markers best reflect the association between isometric training intensity and reduction in resting blood pressure observed after bilateral leg isometric exercise training.  相似文献   

6.
The aim of this study was to evaluate the reliability of two long jump tasks and their ability to predict 10 m sprint performance in elite adolescent female athletes. Eight junior national-level female track and field athletes completed three standing (SLJ) and reactive long jumps (RLJ) on portable force plates, followed by three 10 m sprints. Intra-class correlation coefficients (ICC) and coefficients of variation (CV) were calculated to examine reliability. Linear regression results identified the best predictor of average and best 10 m sprint time from the jump kinematic and kinetic measures. The ICCs and CVs indicated good reliability for the majority of kinetic measures however, better reliability was reported for the SLJ. The SLJ was a good predictor of best and average 10 m sprint time, with average horizontal power the best predictor of performance (best; R 2 = 0.751, p = 0.003, Standard Error of Estimate (SEE)% = 2.2 average; R 2 = 0.708, p = 0.005, SEE% = 2.5).  相似文献   

7.
This study compared the effects of 12-week sprint interval training (SIT), high-intensity interval training (HIIT), and moderate-intensity continuous training (MICT) on cardiorespiratory fitness (V?O2peak), body mass and insulin sensitivity in overweight females. Forty-two overweight women (age 21.2 ± 1.4 years, BMI 26.3 ± 2.5 kg·m?2) were randomized to the groups of SIT (80 × 6-s sprints + 9-s rest), and isoenergetic (300KJ) HIIT (~9 × 4-min cycling at 90% V?O2peak + 3-min rest) and MICT (cycling at 60% V?O2peak for ~ 61-min). Training intervention was performed 3 d·week?1 for 12 weeks. After intervention, all three groups induced the same improvement in V?O2peak (~ +25%, p < 0.001) and a similar reduction in body mass (~ – 5%, p < 0.001). Insulin sensitivity and fasting insulin levels were improved significantly on post-training measures in SIT and HIIT by ~26% and ~39% (p < 0.01), respectively, but remain unchanged in MICT. In contrast, fasting glucose levels were only reduced with MICT (p < 0.01). The three training strategies are equally effective in improving V?O2peak and reducing body mass, however, the SIT is time-efficient. High-intensity training (i.e. SIT and HIIT) seems to be more beneficial than MICT in improving insulin sensitivity.

Abbreviations: BMI: body mass index; CVD: cardiovascular disease; HIEG: hyperinsulinaemic euglycaemic glucose; HIIT: high-intensity interval training; HOMA-IR: homeostasis model assessment of insulin resistance; HR: heart rate; MICT: moderate-intensity continuous training; RPE: ratings of perceived exertion; SIT: sprint interval training; T2D: type 2 diabetes; V?O2peak: peak oxygen consumption  相似文献   


8.
The aim of this study was to compare the kinetic and kinematic parameters of standing and crouch sprint starts. Parallel starts (PS), false starts (FS), jump starts (JS) and crouch starts (3PS) were compared. Eighteen participants performed each start on a force plate and six infrared cameras captured the three-dimensional coordinates of 36 retro-reflective markers. Performance during a five-metre sprint (T5m) was analysed. Duration of the start phase (Tstart), mean values of horizontal and total ground reaction forces (GRFs) (Fx_mean and Ftot_mean), ratio of force (RF), maximal power (Pmax) and kinetic energy (KE) of each limb were calculated. Significant differences were found for T5m, Tstart, KE, Pmax, Fx_mean, Ftot_mean and RF for the crouch start compared to the other starts (P ≤ 0.05). Significant correlations were found between T5m and Tstart (r = 0.59; P ≤ 0.001), and T5m and Pmax, Fx_mean and RF (?0.73 ≤ r ≤ ?0.61; P ≤ 0.001). To conclude, the crouch start resulted in the best performance because Tstart was shorter, producing greater Pmax, Fx_mean with a more forward orientation of the resultant force. Greater KE of the trunk in each start condition demonstrated the role of the trunk in generating forward translation of the centre of mass (CM).  相似文献   

9.
Abstract

Seven 6 s sprints with 30 s recovery between sprints were performed against two resistive loads: 50 (L50) and 100 (L100) g · kg?1 body mass. Inertia-corrected and -uncorrected peak and mean power output were calculated. Corrected peak power output in corresponding sprints and the drop in peak power output relative to sprint 1 were not different in the two conditions, despite the fact that mean power output was 15–20% higher in L100 (P < 0.01). The effect of inertia correction on power output was more pronounced for the lighter load (L50), with uncorrected peak power output in sprint 1 being 42% lower than the corresponding corrected peak power output, while this was only 16% in L100. Fatigue assessed by the drop in uncorrected peak and mean power output in sprint 7 relative to sprint 1 was less compared with that obtained by corrected power values, especially in L50 (drop in uncorrected vs. corrected peak power output: 13.3 ± 2.2% vs. 23.1 ± 4.1%, P < 0.01). However, in L100, the difference between the drop in corrected and uncorrected mean power output in sprint 7 was much smaller (24.2 ± 3.1% and 21.2 ± 2.7%, P < 0.01), indicating that fatigue may be safely assessed even without inertia correction when a heavy load is used. In conclusion, when inertia correction is performed, fatigue during repeated sprints is unaffected by resistive load. When inertia correction is omitted, both power output and the fatigue profile are underestimated by an amount dependent on resistive load. In cases where inertia correction is not possible during a repeated sprints test, a heavy load may be preferable.  相似文献   

10.
This study aimed to explore the strength of the force–velocity (FV) relationship of lower limb muscles and the reliability of its parameters (maximum force [F0], slope [a], maximum velocity [V0], and maximum power [P0]). Twenty-three men were tested in two different jump types (squat and countermovement jump: SJ and CMJ), performed under two different loading conditions (free weight and Smith machine: Free and Smith) with 0, 17, 30, 45, 60, and 75?kg loads. The maximum and averaged values of F and V were obtained for the FV relationship modelling. All FV relationships were strong and linear independently whether observed from the averaged across the participants (r?≥?0.98) or individual data (r?=?0.94–0.98), while their parameters were generally highly reliable (F0 [CV: 4.85%, ICC: 0.87], V0 [CV: 6.10%, ICC: 0.82], a [CV: 10.5%, ICC: 0.81], and P0 [CV: 3.5%, ICC: 0.93]). Both the strength of the FV relationships and the reliability of their parameters were significantly higher for (1) the CMJ over the SJ, (2) the Free over the Smith loading type, and (3) the maximum over the averaged F and V variables. In conclusion, although the FV relationships obtained from all the jumps tested were linear and generally highly reliable, the less appropriate choice for testing the FV relationship could be through the averaged F and V data obtained from the SJ performed either in a Free weight or in a Smith machine. Insubstantial differences exist among the other combinations tested.  相似文献   

11.
Abstract

To develop a track version of the maximal anaerobic running test, 10 sprint runners and 12 distance runners performed the test on a treadmill and on a track. The treadmill test consisted of incremental 20-s runs with a 100-s recovery between the runs. On the track, 20-s runs were replaced by 150-m runs. To determine the blood lactate versus running velocity curve, fingertip blood samples were taken for analysis of blood lactate concentration at rest and after each run. For both the treadmill and track protocols, maximal running velocity (v max), the velocities associated with blood lactate concentrations of 10 mmol · l?1 ( v 10 mM) and 5 mmol · l?1 ( v 5 mM), and the peak blood lactate concentration were determined. The results of both protocols were compared with the seasonal best 400-m runs for the sprint runners and seasonal best 1000-m time-trials for the distance runners. Maximal running velocity was significantly higher on the track (7.57 ± 0.79 m · s?1) than on the treadmill (7.13 ± 0.75 m · s?1), and sprint runners had significantly higher v max, v 10 mM, and peak blood lactate concentration than distance runners (P<0.05). The Pearson product – moment correlation coefficients between the variables for the track and treadmill protocols were 0.96 (v max), 0.82 (v 10 mM), 0.70 (v 5 mM), and 0.78 (peak blood lactate concentration) (P<0.05). In sprint runners, the velocity of the seasonal best 400-m run correlated positively with v max in the treadmill (r = 0.90, P<0.001) and track protocols (r = 0.92, P<0.001). In distance runners, a positive correlation was observed between the velocity of the 1000-m time-trial and v max in the treadmill (r = 0.70, P<0.01) and track protocols (r = 0.63, P<0.05). It is apparent that the results from the track protocol are related to, and in agreement with, the results of the treadmill protocol. In conclusion, the track version of the maximal anaerobic running test is a valid means of measuring different determinants of sprint running performance.  相似文献   

12.
The purpose of this study was to explore the relationships between mechanical power, thrust power, propelling efficiency and sprint performance in elite swimmers. Mechanical power was measured in 12 elite sprint male swimmers: (1) in the laboratory, by using a whole-body swimming ergometer (W'TOT) and (2) in the pool, by measuring full tethered swimming force (FT) and maximal swimming velocity (Vmax): W'T = FT · Vmax. Propelling efficiency (ηP) was estimated based on the “paddle wheel model” at Vmax. Vmax was 2.17 ± 0.06 m · s?1, ηP was 0.39 ± 0.02, W'T was 374 ± 62 W and W'TOT was 941 ± 92 W. Vmax was better related to W'T (useful power output: R = 0.943, P < 0.001) than to W'TOT (total power output: R = 0.744, P < 0.01) and this confirms the use of the full tethered test as a valid test to assess power propulsion in sprinters and to estimate swimming performance. The ratio W'T/W'TOT (0.40 ± 0.04) represents the fraction of total mechanical power that can be utilised in water (e.g., ηP) and was indeed the same as that estimated based on the “paddle wheel model”; this supports the use of this model to estimate ηP in swimming.  相似文献   

13.
The purpose of this study was to determine the effectiveness of a 4-week running sprint interval training protocol to improve both aerobic and anaerobic fitness in middle-aged adults (40–50 years) as well as compare the adaptations to younger adults (20–30 years). Twenty-eight inactive participants – 14 young 20–30-year-olds (n = 7 males) and 14 middle-aged 40–50-year-olds (n = 5 males) – completed 4 weeks of running sprint interval training (4 to 6, 30-s “all-out” sprints on a curved, self-propelled treadmill separated by 4 min active recovery performed 3 times per week). Before and after training, all participants were assessed for maximal oxygen consumption (VO2max), 2000 m time trial performance, and anaerobic performance on a single 30-s sprint. There were no interactions between group and time for any tested variable, although training improved relative VO2max (young = 3.9, middle-aged = 5.2%; P < 0.04), time trial performance (young = 5.9, middle-aged = 8.2%; P < 0.001), peak sprint speed (young = 9.3, middle-aged = 2.2%; P < 0.001), and average sprint speed (young = 6.8, middle-aged = 11.6%; P < 0.001) in both young and middle-aged groups from pre- to post-training on the 30-s sprint test. The current study demonstrates that a 4-week running sprint interval training programme is equally effective at improving aerobic and anaerobic fitness in younger and middle-aged adults.  相似文献   

14.
Abstract

The purpose of this study was to assess both short-term reliability and long-term stability of anthropometric and physical performance measures in highly-trained young soccer players in relation to age and maturation. Data were collected on 80 players from an academy (U13–U18, pre- (n = 14), circum- (n = 32) and post- (n = 34) estimated peak height velocity, PHV). For the reliability analysis, anthropometric and performance tests were repeated twice within a month. For the stability analysis, these tests were repeated 12 times over a 4-year period in 10 players. Absolute reliability was assessed with the typical error of measurement, expressed as a coefficient of variation (CV). Relative reliability and long-term stability were assessed using the intraclass correlation coefficient (ICC). There was no clear age or maturation effect on either the CVs or ICCs: e.g., Post-PHV vs. Pre-PHV: effect size = –0.37 (90% confidence limits (CL):-1.6;0.9), with chances of greater/similar/lower values of 20/20/60%. For the long-term stability analysis, ICCs varied from 0.66 (0.50;0.80) to 0.96 (0.93;0.98) for 10-m sprint time and body mass, respectively. The short-term reliability of anthropometry and physical performance measures is unlikely to be affected by age or maturation. However, some of these measures are unstable throughout adolescence, which questions their usefulness in a talent identification perspective.  相似文献   

15.
Abstract

The main aim of this study was to determine whether the use of an imposed or freely chosen crank rate would influence submaximal and peak physiological responses during arm crank ergometry. Fifteen physically active men participated in the study. Their mean age, height, and body mass were 25.9 (s = 6.2) years, 1.80 (s = 0.10) m, and 78.4 (s = 6.1) kg, respectively. The participants performed two incremental peak oxygen consumption ([Vdot]O2peak) tests using an electronically braked ergometer. One test was performed using an imposed crank rate of 80 rev · min?1, whereas in the other the participants used spontaneously chosen crank rates. The order in which the tests were performed was randomized, and they were separated by at least 2 days. Respiratory data were collected using an on-line gas analysis system, and fingertip capillary blood samples (~20 μl) were collected for the determination of blood lactate concentration. Heart rate was also recorded throughout the tests. Time to exhaustion was measured and peak aerobic power calculated. Submaximal data were analysed using separate two-way repeated-measures analyses of variance, while differences in peak values were analysed using separate paired t-tests. Variations in spontaneously chosen crank rate were assessed using a one-way analysis of variance with repeated measures. Agreement between the crank rate strategies for the assessment of peak values was examined by calculating intra-class correlation coefficients (ICC) and 95% limits of agreement (95% LoA). While considerable between-participant variations in spontaneously chosen crank rate were observed, the mean value was not different (P > 0.05) from the imposed crank rate of 80 rev · min?1 at any point. No differences (P > 0.05) were observed for submaximal data between crank strategies. Furthermore, mean peak minute power [158 (s = 20) vs. 158 (s = 18) W], time to exhaustion [739 (s = 118) vs. 727 (s = 111) s], and [Vdot]O2peak[3.09 (s = 0.38) vs. 3.04 (s = 0.34) l · min?1] were similar for the imposed and spontaneously chosen crank rates, respectively. However, the agreement for the assessment of [Vdot]O2peak (ICC = 0.78; 95% LoA = 0.04 ± 0.50 l · min?1) between the cranking strategies was considered unacceptable. Our results suggest that either an imposed or spontaneously chosen crank rate strategy can be used to examine physiological responses during arm crank ergometry, although it is recommended that the two crank strategies should not be used interchangeably.  相似文献   

16.
Abstract

The aims of this study were two-fold: (1) to consider the criterion-related validity of the multi-stage fitness test (MSFT) by comparing the predicted maximal oxygen uptake ([Vdot]O2max) and distance travelled with peak oxygen uptake ([Vdot]O2peak) measured using a wheelchair ergometer (n = 24); and (2) to assess the reliability of the MSFT in a sub-sample of wheelchair athletes (n = 10) measured on two occasions. Twenty-four trained male wheelchair basketball players (mean age 29 years, s = 6) took part in the study. All participants performed a continuous incremental wheelchair ergometer test to volitional exhaustion to determine [Vdot]O2peak, and the MSFT on an indoor wooden basketball court. Mean ergometer [Vdot]O2peak was 2.66 litres · min?1 (s = 0.49) and peak heart rate was 188 beats · min?1 (s = 10). The group mean MSFT distance travelled was 2056 m (s = 272) and mean peak heart rate was 186 beats · min?1 (s = 11). Low to moderate correlations (ρ = 0.39 to 0.58; 95% confidence interval [CI]: ?0.02 to 0.69 and 0.23 to 0.80) were found between distance travelled in the MSFT and different expressions of wheelchair ergometer [Vdot]O2peak. There was a mean bias of ?1.9 beats · min?1 (95% CI: ?5.9 to 2.0) and standard error of measurement of 6.6 beats · min?1 (95% CI: 5.4 to 8.8) between the ergometer and MSFT peak heart rates. A similar comparison of ergometer and predicted MSFT [Vdot]O2peak values revealed a large mean systematic bias of 15.3 ml · kg?1 · min?1 (95% CI: 13.2 to 17.4) and standard error of measurement of 3.5 ml · kg?1 · min?1 (95% CI: 2.8 to 4.6). Small standard errors of measurement for MSFT distance travelled (86 m; 95% CI: 59 to 157) and MSFT peak heart rate (2.4 beats · min?1; 95% CI: 1.7 to 4.5) suggest that these variables can be measured reliably. The results suggest that the multi-stage fitness test provides reliable data with this population, but does not fully reflect the aerobic capacity of wheelchair athletes directly.  相似文献   

17.
Abstract

The aim of this study was to assess the efficacy of electromyography (EMG) normalization methods for a high-speed 20-m sprint. Comparisons were based on intra-individual reliability and magnitude of normalized EMG signals from three repeat sessions separated by 1 day (between days) and 1 week (between weeks) from the initial test. Surface EMGs were recorded (n=16) from the medial and lateral gastrocnemius and soleus during the normalization methods (isometric: maximum/sub-maximum/body weight; isotonic: maximum/sub-maximum/body weight; isokinetic: 1.05 rad · s–1, 1.31 rad · s–1, 1.83 rad · s–1; squat jump). The EMG data from the 20-m sprint were normalized using each method and using the within-sprint peak EMG (sprint peak). Intra-individual reliability of the EMG was assessed using typical error of measurement as a percentage of intra-individual coefficient of variance (TEMCV%). Sprint peak normalization improved intra-individual reliability of EMG (soleus: <4.91CV%; medial gastrocnemius: <6.2CV%; lateral gastrocnemius: <7.1CV%) compared with un-normalized EMG (soleus: <13.3CV%; medial gastrocnemius: <16.5CV%; lateral gastrocnemius: <16.3CV%) both between days and between weeks. Squat jump normalization improved the soleus (<11.2CV%) and medial gastrocnemius (<15.7CV%) reliability between days and weeks and provided a representative measure of triceps surae muscle activation. The intra-individual reliability of the medial gastrocnemius EMG data was improved both between days and weeks when using isotonic normalization. Isometric and isokinetic normalization showed no improvement in intra-individual reliability either between days or weeks for any muscle. The method of normalization influenced the between-stride muscle interaction during the 20-m sprint. The results of this study suggest that peak normalization can be used to normalize high-speed muscle actions, while normalizing EMG to a squat jump may provide an alternative method to represent relative muscle activation.  相似文献   

18.
Abstract

The aim of this study was to establish a graded exercise test protocol for determining the peak physiological responses of female outrigger canoeists. Seventeen trained female outrigger canoeists completed two outrigger ergometer graded exercise test protocols in random order: (1) 25 W power output for 2 min increasing by 7.5 W every minute until exhaustion; and (2) 25 W power output for 2 min increasing by 15 W every 2 min to exhaustion. Heart rate and power output were recorded every 15 s. Expired air was collected continuously and sampled for analysis at 15-s intervals, while blood lactate concentration was measured immediately after and 3, 5, and 7 min after exercise. The peak physiological and performance variables examined included peak oxygen uptake ([Vdot]O2peak), minute ventilation, tidal volume, ventilatory thresholds 1 and 2, respiratory rate, respiratory exchange ratio, heart rate, blood lactate concentration, power output, performance time, and time to [Vdot]O2peak. There were no significant differences in peak physiological responses, ventilatory thresholds or performance variables between the two graded exercise test protocols. Despite no significant differences between protocols, due to the large limits of agreement evident between protocols for the peak physiological responses, it is recommended that the same protocol be used for all comparison testing to minimize intra-individual variability of results.  相似文献   

19.
Abstract

In this study, we examined the effects of a supervised, heart rate intensity prescribed walking training programme on cardiorespiratory fitness and glycaemic control in people with type 2 diabetes mellitus. After receiving local ethics approval, 27 individuals (21 males, 6 females) with type 2 diabetes were randomly assigned to an experimental (“walking”) or control group. Participants completed a Balke-Ware test to determine peak heart rate, peak oxygen consumption ([Vdot]O2peak), and peak gradient. The walking group then completed a 7-week (four sessions a week) supervised, heart rate prescribed walking training programme, whereas the control group continued daily life. After training, participants completed another Balke-Ware test. Fasting blood glucose and glycosylated haemoglobin were measured at rest. The results showed that walking training elicited 80% (s = 2) of peak heart rate and a rating of perceived exertion of 11 (s = 1). Peak heart rate and [Vdot]O2peak were higher in the walking than in the control group after training (P < 0.05). Based on the peak gradient before training, the respiratory exchange ratio was significantly lower (P < 0.05) and there was a strong trend for [Vdot]O2 (P = 0.09) and heart rate (P = 0.09) to be lower after training at the same gradient in the walking compared with the control group. These improvements increased walking peak gradient by 5 min (s = 4 min) compared with the control (P < 0.05). There was no change in fasting blood glucose or glycosylated haemoglobin after training. Despite no change in glycaemic control, heart rate prescribed walking improved peak and sub-maximal cardiorespiratory responses. The beneficial adaptations support the use of heart rate monitoring during walking in people with type 2 diabetes mellitus.  相似文献   

20.
This study compared the responses of two priming exercises of similar fatigue on the adjustment of the oxygen uptake time constant (τV?O2) in cycling. Ten healthy young adults (25 ± 3 yr) performed: three step transitions from a 20-W baseline to the power output (PO) below the gas exchange threshold (MOD, MODPRE); a 3-min bout (P3MIN) at 90% of peak PO (POpeak), followed by MOD (MOD3MIN); and a 6-min bout (P6MIN) at 80% of POpeak, followed by MOD (MOD6MIN). The O2 supply-to-O2 demand ([HHb]/V?O2) ratio was calculated for MODPRE, MOD3MIN, and MOD6MIN. Neuromuscular fatigue was measured isometrically pre- and post-priming exercise. Reductions in maximal voluntary contraction (?29 ± 6 vs ?34 ± 7%) and high-frequency doublet amplitude (?48 ± 13 vs ?43 ± 11%) were not significantly different between P3MIN vs P6MIN, suggesting similar fatigue. τV?O2 for MOD3MIN and MOD6MIN were similar, being ~25% smaller than MODPRE. The [HHb]/V?O2 ratio was significantly greater in MODPRE (1.13 ± 0.12) compared to MOD3MIN (1.02 ± 0.04) and MOD6MIN (1.02 ± 0.04). This study showed that priming exercise of shorter duration and higher intensity, was sufficient to accelerate V?O2 kinetics similarly to that observed subsequent to P6MIN when the muscle fatigue was similar.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号