首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   65篇
  免费   2篇
  国内免费   1篇
教育   32篇
科学研究   16篇
各国文化   1篇
体育   17篇
信息传播   2篇
  2021年   4篇
  2020年   2篇
  2018年   1篇
  2017年   4篇
  2016年   1篇
  2015年   3篇
  2014年   3篇
  2013年   11篇
  2012年   4篇
  2011年   6篇
  2010年   2篇
  2009年   2篇
  2006年   3篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   2篇
  2001年   1篇
  2000年   1篇
  1992年   1篇
  1989年   1篇
  1987年   1篇
  1986年   1篇
  1985年   1篇
  1984年   3篇
  1983年   1篇
  1981年   2篇
  1977年   1篇
  1975年   2篇
排序方式: 共有68条查询结果,搜索用时 750 毫秒
1.
2.
The proximal-to-distal segmental sequence has been identified in many sports activities, including baseball pitching and ball kicking. However, proximal-to-distal sequential muscle activity has not been identified. The aims of this study were to establish whether sequential muscle activity does occur and, if it does, to determine its functional role. We recorded surface electromyograms (EMGs) for 17 muscles from the upper extremity and abdomen during overarm throwing and detected the onset and peak times as indices of muscle activity. The following electromyographic properties were commonly identified in the participants. First, sequential muscle activity was observed from the scapular protractors to the shoulder horizontal flexors and from the shoulder horizontal flexors to the elbow extensor, but not from the elbow extensor to the wrist flexor or forearm pronator. Secondly, the external oblique contralateral to the throwing arm became activated before the ipsilateral external oblique. This sequence is considered to be very effective for the generation of high force and energy in the trunk. Thirdly, the ipsilateral external oblique began its activity almost at foot strike. Finally, the main activity of the rectus abdominis appeared just before the point of release.  相似文献   
3.
This paper considers distributed consensus problem of multi-agent systems consisting of general linear dynamics with a time-invariant communication topology. A distributed full-order observer type consensus protocol based on relative output measurements of neighbor agents is proposed. It is found that the consensus problem of linear multi-agent systems with a directed communication topology having a spanning tree can be solved if and only if all subsystems are asymptotically stable. Some necessary and sufficient conditions are obtained for ensuring consensus in multi-agent systems. The design technique is based on algebraic graph theory, Riccati inequality and linear control theory. Finally, simulation example is given to illustrate the effectiveness of the theoretical results.  相似文献   
4.
In this paper, we propose a new learning method for extracting bilingual word pairs from parallel corpora in various languages. In cross-language information retrieval, the system must deal with various languages. Therefore, automatic extraction of bilingual word pairs from parallel corpora with various languages is important. However, previous works based on statistical methods are insufficient because of the sparse data problem. Our learning method automatically acquires rules, which are effective to solve the sparse data problem, only from parallel corpora without any prior preparation of a bilingual resource (e.g., a bilingual dictionary, a machine translation system). We call this learning method Inductive Chain Learning (ICL). Moreover, the system using ICL can extract bilingual word pairs even from bilingual sentence pairs for which the grammatical structures of the source language differ from the grammatical structures of the target language because the acquired rules have the information to cope with the different word orders of source language and target language in local parts of bilingual sentence pairs. Evaluation experiments demonstrated that the recalls of systems based on several statistical approaches were improved through the use of ICL.  相似文献   
5.
It is essential for medical students to learn and comprehend human anatomy in three dimensions (3D). With this in mind, a new system was designed in order to integrate anatomical dissections with diagnostic computed tomography (CT) radiology. Cadavers were scanned by CT scanners, and students then consulted the postmortem CT images during cadaver dissection to gain a better understanding of 3D human anatomy and diagnostic radiology. Students used handheld digital imaging and communications in medicine viewers at the bench‐side (OsiriX on iPod touch or iPad), which enabled “pixel‐to‐tissue” direct comparisons of CT images and cadavers. Students had lectures and workshops on diagnostic radiology, and they completed study assignments where they discussed findings in the anatomy laboratory compared with CT radiology findings. This teaching method for gross and radiological anatomy was used beginning in 2009, and it yielded strongly positive student perspectives and significant improvements in radiology skills in later clinical courses. Anat Sci Educ 7: 438–449. © 2014 American Association of Anatomists.  相似文献   
6.
A microfluidic device was successfully fabricated for the rapid serodiagnosis of amebiasis. A micro bead-based immunoassay was fabricated within integrated microfluidic chip to detect the antibody to Entamoeba histolytica in serum samples. In this assay, a recombinant fragment of C terminus of intermediate subunit of galactose and N-acetyl-D-galactosamine-inhibitable lectin of Entamoeba histolytica (C-Igl, aa 603-1088) has been utilized instead of the crude antigen. This device was validated with serum samples from patients with amebiasis and showed great sensitivity. The serodiagnosis can be completed within 20 min with 2 μl sample consumption. The device can be applied for the rapid and cheap diagnosis of other infectious disease, especially for the developing countries with very limited medical facilities.Entamoeba histolytica is the causative agent of amebiasis and is globally considered a leading parasitic cause of human mortality.1 It has been estimated that 50 × 106 people develop invasive disease such as amebic dysentery and amebic liver abscess, resulting in 100 000 deaths per annum.2, 3 High sensitive diagnosis method for early stage amebiasis is quite critical to prevent and cure this disease. To date, various serological tests have been used for the immune diagnosis of amebiasis, such as the indirect fluorescent antibody test (IFA) and enzyme-linked immunosorbent assay (ELISA).We have recently identified a 150-kDa surface antigen of E. histolytica as an intermediate subunit (Igl) of galactose and N-acetyl-D-galactosamine-inhibitable lectin.4, 5 In particular, it has been shown that the C-terminus of Igl (C-Igl, aa 603-1088) was an especially useful antigen for the serodiagnosis of amebiasis. ELISA using C-Igl is more specific than the traditional ELISA using crude antigen.6 However, the ELISA process usually takes several hours, which is still labor-intensive and requires experienced operators to perform. More economic and convenient filed diagnosis methods are still in need, especially for the developing countries with limited medical facilities.Among all the bioanalytical techniques, microfluidics has been attracting more and more attention because of its low reagent/power consumption, the rapid analysis speed as well as easy automation.7, 8, 9, 10, 11 Especially with the development of the fabrication technique, microfluidics chip can include valves, mixers, pumps, heating devices, and even micro sensors, so many traditional bioanalytical methods can be performed in the microfluidics. Qualitative and quantitative immune analysis on the microfluidic chip was successfully proved by plenty of research with improved sensitivity, shorten reaction time, and less sample consumption.8, 10, 11, 12, 13, 14, 15, 16, 17 Moreover, with the intervention of other physical, chemical, biology, and electronic technology, microfluidic technique has been successfully utilized in protein crystallization, protein and gene analysis, cell capture and culturing and analysis as well as in the rapid and quantitative detection of microbes.13, 14, 15, 16, 17, 18, 19, 20Herein, we report a new integrated microfluidic device, which is capable of rapid serodiagnosis of amebiasis with little sample consumption. The microfluidic device was fabricated from polydimethysiloxane (PDMS) following standard soft lithography.21, 22 The device was composed of two layers (shown in Figure Figure1)1) including upper fluidic layer (in green and blue) and bottom control layer (in red).Open in a separate windowFigure 1Structure illustration of microfluidic chip.To create the fluidic layer and the control layer, two different molds with different patterns have fabricated by photolithographic processes. The mold to create the fluidic channels was made by positive photoresist (AZ-50 XT), while the control pneumatic mold was made by negative photoresist (SU8 2025). For the chip fabrication, the fluidic layer is made from PDMS (RTV 615 A: B in ratio 5:1), and the pattern was transferred from the respective mold. The control layer is made from PDMS (RTV 615 A:B in ratio 20:1). The two layers were assembled and bonded together accurately, and there is elastic PDMS membrane about 30 μm thick between the fluidic layer channels and control layer.21, 22 The elastic membrane at the intersection can deform to block the fluid inside the fluidic channels, functioning as valves under the pressures introduced though control channels. There are two types of channels in fluidic layer, the rectangular profiled (in green, 200 μm wide, 35 μm thick) channel and round profiled channels (in blue, 200 μm wide, 25 μm center height). Because of the position of the valves on the fluidic channels, two types of valves (Figure (Figure2a)2a) were built, working as a standard valve and a sieve valve. The standard valves (on blue fluidic channels) can totally block the fluid because of the round profile of fluidic channel; the sieve valve can only half close because of the rectangular profile. The sieve valve can be used to trap the microspheres (beads) filled inside the green fluidic channels, while letting the fluid pass through. By this sieve valve, a micro column (in green) is constructed, where the entire ELISA reaction happens. The micrograph of the fabricated micro device is shown in Figure Figure2b.2b. The channels were filled with food dyes in different colors to show the relative positions of the channels. The pressures though different control channels are individually controlled by solenoid valves, connected to a computer through relay board. By programming the status (on/off) of various valves at different time periods, all the microfluidic chip operation can be digitally controlled by the computer in manual, semi-automatic, or automatic manner.Open in a separate windowFigure 2(a) Structure illustration of micro column, standard valve and sieve valve; (b) photograph of the microfluidic chip.To validate this device, 12 patient serum samples were collected. Sera from 9 patients (Nos. 1–9) with an amebic liver abscess or amebic colitis were used as symptomatic cases. The diagnosis of these patients was based on their clinical symptoms, ultrasound examination (liver abscess) and endoscopic or microscopic examination (colitis). We also identified the clinical samples using PCR amplification of rRNA genes.24 As negative control, sera obtained from 3 healthy individuals with no known history of amebiasis were mixed into pool sera. The serum was positive for E. histolytica with a titer of 1:64 (borderline positive), as determined by an indirect fluorescent-antibody (IFA) test.23, 24 In our previously study, the sensitivity and specificity of the recombinant C-Igl in the ELISA were 97% and 99%.6, 25 In the current study, the serodiagnosis of amebiasis was also examined by ELISA using C-Igl.26 The cut-off for a positive result was defined as an ELISA value > 3 SD above the mean for healthy negative controls27 (shown in Figure Figure3).3). The seropositivity to C-Igl was 100% in patients with amebiasis.Open in a separate windowFigure 3ELISA reactivity of sera from patients against C-Igl. ELISA plate was coated with 100 ng per well of C-Igl. Serum samples from patients and healthy controls were used at 1:400 dilutions. The dashed line indicates the cut-off value. Data are representative of results from three independent experiments.In the diagnosis process with microfluidic chip, the 4 micro immuno-columns filled with C-Igl-coated microspheres were the key components of the device. The C-Igl was prepared in E. coli as inclusion bodies. After expression, the recombinant protein was purified and analyzed by SDS-PAGE. The apparent molecular mass was 85 kDa.26The immune-reaction mechanism is illustrated in Figure Figure4.4. The anti-His monocolonal antibody was immobilized onto the microspheres (beads, 9 μm diameter) coated with protein A. The C-Igl was then immobilized onto the beads through the binding between the His tag and C-Igl. For the diagnosis, the microspheres immobilized with C-Igl and blocked by 5% BSA were preloaded into the columns for the rapid analysis of the patient serum samples. Generally, serum samples which were diluted 100 times were first loaded into the reaction column and incubated at room temperature for 5 min. After being washed by PBS buffer, FITC-conjugated goat anti-human polyclonal antibody was added into the column for 4 min incubation. The fluorescence image can be collected by the fluorescence microscope after the micro column was washed with PBS buffer. From loading diluted serum samples into column to collecting fluorescence images, the total time to complete the immunoassay is less than 10 min. The final fluorescence results were analyzed by Image Pro Plus 6.0.Open in a separate windowFigure 4Schematic representation of the ELISA in the chip.Different reaction conditions have been investigated to find the optimized ones. For each patient, 2 μl sample is enough for the analysis. The designed microfluidic chip with 4 micro columns is capable for 4 parallel analyses at the same time. More micro columns can be integrated into the device if more parallel tests are needed.Different incubating time for the diagnosis has also been investigated and no significant difference has been found for various time periods. It is enough to incubate the chip for only 5 min. The total diagnosis time for one sample is less than 10 min. The detection result appeared as the fluorescence intensity of the reaction column. As shown in Figure Figure5,5, the negative sample showed relatively low fluorescence intensity, because little FITC-conjugated goat anti-human polyclonal antibody could attach to the surface of microspheres; on the contrast, the positive sample showed much brighter fluorescence. The fluorescence intensity can be transferred to digital data (Table
SampleAverage scoresStandard deviation
133 790368
223 269271
339 598307
4778452
521 222197
638 878290
722 437227
836 295334
941 024396
Negative20032
Open in a separate windowOpen in a separate windowFigure 5ELISA on the chip. The signals were collected by CCD of microscope. A: negative sample; B and C: positive samples.For the heterogeneous immunoreactions, the immobilization of the immune molecules is essential for the reaction efficiency. Herein, we utilized micro columns filled with pre-modified microspheres (beads) instead of the direct surface modification for the ELISA analysis. Compared with the traditional method, diagnosis using the microfluidic device took less than 10 min with only 2 μl sample consumption and little reagent consumption. The high efficiency might be attributed to the high surface modification efficiency by using beads as well as the advantages from microfluidic device itself. The C-Igl modified microspheres can be easily prepared in 1 h and preloaded inside the micro device for convenient application. The device is made from standard soft lithography by PDMS and its throughput can be easily improved by adding more micro columns into the microfluidic device in an economic manner, which is perfect for the onsite rapid and cheap diagnosis of amebiasis. Similar methodologies can be developed for diagnosis of other infectious disease, especially for the developing countries with very limited medical facilities.  相似文献   
7.
Differences in body composition and risk of lifestyle-related diseases between young and older male rowers and sedentary controls     
Kiyoshi Sanada  Motohiko Miyachi  Izumi Tabata  Katsuhiko Suzuki  Kenta Yamamoto  Hiroshi Kawano 《Journal of sports sciences》2013,31(10):1027-1034
Abstract

The aim of this cross-sectional study was to compare body composition and risk factors of lifestyle-related diseases between young and older male rowers and sedentary controls. Healthy males aged 19–73 years participated in the study, and were divided into four groups: 26 young rowers, 24 senior rowers, 23 young sedentary controls, and 22 senior sedentary controls. Total and regional lean soft tissue, fat mass, and bone mineral density were measured using dual-energy X-ray absorptiometry. The HDL-cholesterol of senior rowers (67.4 ± 13.4 mg · dl?1) was significantly (P < 0.05) higher than that of senior sedentary controls (59.2 ± 11.9 mg · dl?1), while HDL-cholesterol was similar in senior rowers and young rowers (66.1 ± 10.8 mg · dl?1). Arm, leg, and trunk lean soft tissue mass were significantly higher in senior rowers (5.6 ± 0.6 kg, 18.2 ± 1.8 kg, and 27.3 ± 3.2 kg respectively) than in senior sedentary controls (5.1 ± 0.4 kg, 16.3 ± 1.4 kg, and 24.6 ± 1.7 kg respectively; P < 0.05). Bone mineral density was also significantly higher in senior rowers than in senior sedentary controls (ribs, lumbar spine, and pelvic segments; P < 0.05). We conclude that age-related increases in the risk of lifestyle-related diseases, such as osteoporosis and sarcopenia, are attenuated in male rowers. These results suggest that regular rowing exercise may have a positive influence in the prevention of lifestyle-related diseases in older Japanese people.  相似文献   
8.
Loading differences in single-leg landing in the forehand- and backhand-side courts after an overhead stroke in badminton: A novel tri-axial accelerometer research     
Shogo Sasaki  Yasuharu Nagano  Hiroshi Ichikawa 《Journal of sports sciences》2013,31(24):2794-2801
ABSTRACT

Anterior cruciate ligament (ACL) injuries in badminton commonly occur during single-leg landing after an overhead stroke in the backhand-side court. This study compared differences in trunk acceleration and kinematic variables during single-leg landing in the forehand- and backhand-side courts after an overhead stroke. Eighteen female junior badminton players performed two singles games while wearing a tri-axial accelerometer. The moment that over 4g of resultant acceleration was generated was determined using synchronised video cameras. Trunk lateral inclination and hip abduction angles at the point of landing with over 4g of resultant acceleration were analysed. Mediolateral acceleration in the backhand-side court was greater than that in the opposite-side court (< 0.001, ES = 0.840). Both trunk lateral angles were larger than those previously reported in injured participants and the hip abduction angle in the backhand-side court was larger than that in the forehand-side court (< 0.001, ES = 2.357). The lateral and vertical acceleration in the backhand-side court showed moderate-to-strong correlations with the trunk and hip angles. The mediolateral physical demand and high-risk posture in the backhand-side court may be associated with a higher incidence of knee injuries during badminton games.  相似文献   
9.
The Diffusion of Mobile Internet in Japan     
Mito Akiyoshi  Hiroshi Ono 《The Information Society》2013,29(5):292-303
In Japan, the mobile phone has become an increasingly popular medium of accessing the Internet and e-mail, especially among those who may not have affordable access to a computer. The lower startup costs and the easier overall accessibility of mobile phones relative to personal computers suggest that the mobile phone may be a possible alternative for overcoming unequal access to information communication technology in Japan and elsewhere. Using microdata from 2001, we compare and contrast the determinants of mobile versus computer-based Internet in Japan. Our findings show that mobile Internet access, as compared to computer access, is determined less by demographics, socioeconomic status, and technological readiness, suggesting that barriers to Internet access are lower for mobile phones than is the case for computers.  相似文献   
10.
Measurement of current flow through the rat under signaled and unsignaled grid-shock conditions     
Hiroshi Imada  Tetsuro Mino  Kozo Sugioka  Yuji Ohki 《Learning & behavior》1981,9(1):75-79
The present experiment was run to test the hypothesis that, when shock was signaled, rats would develop effective coping responses so as to reduce the current flow through them. A 1-sec shock was delivered through a grid floor by a fixed impedance ac shock source. The current-flow measure was taken over the last 30 of 90 trials given over 3 days and indexed by “gross skin conductance” or GSC (shock). The rat under the signaled shock condition (n=15) showed higher GSC (shock) than did the rats under the unsignaled shock condition (n=14). Thus, the result contradicted the hypothesis. There was no indication that the rats developed any preparatory response during the 5-sec signal, in terms of either GSC (signal) or posture. The results were discussed with reference to the preparatory-response hypothesis and various other possibilities.  相似文献   
1 [2] [3] [4] [5] [6] [7] 下一页 » 末  页»
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号