首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
An external quality assessment was conducted to assess the performance of various laboratories for RIA of thhyroid related hormones in two phases. In the first phase thirty five laboratories participated. At the end of first phase a meeting cum workshop was organised to discuss the results of first phase, difficultires faced by the participants and pinpoint the short oming. A second phase was then initiated with an objective of improvement in the performance, if any, where twelve samples from four pools were distributed to twenty four laboratories who participated for the second phase. The overall return of the results increased significantly from 71.8% (1586/2208) for the first phase to 92.4% (732/792) for the second phase. The inter laboratory %CV for T3, T4 and TSH were lower during the second phase (30.6%, 19.0% and 31.6% respectively) as compared to those observed during first phase (36.3%, 22.7% and 52.8% respectively). Similarly, there was an improvement in reproducibility of ALTM as %CV for T3, T4 and TSH decreased from 6.0%, 9.8% and 13.4% respectively to 4.5%, 4.6% and 8.5% respectively. The individual performances of the participating laboratories viz. bias, variability of bias and imprecision also showed a trend towards improvement as percent laboratories having desirable or acceptable results for T3, T4 and TSH increased from 10.7%, 60.7% and 0.0% respectively to 20.8%, 66.7% and 22.2% respectively. External quality assessment thus appears to be beneficial in assessing the performane of a laboratory in comfparison with other laboratories and indeed helps in improving the performance.  相似文献   

2.
The prevalence of abnormal thyroid hormone levels in diabetes mellitus in Nigeria is not well described. To determine the incidence of abnormal thyroid hormone levels in diabetics in Calabar, Nigeria, fasting blood samples from 161 diabetic subjects and 105 non-diabetic controls were analysed. Free thyroxine (FT), thyroid stimulating hormone (TSH), total triiodothyronine (T3) and total thyroxine (T4) kits obtained from Biomerica Inc. of USA were used for the analysis. TSH levels (1.80±1.62) in diabetics were significantly lower (p=0.016) than the level in non-diabetic controls (2.34±1.24). Male diabetics had lower (p<0.05) levels of TSH (1.192±0.68 miu/ml) than diabetic females (1.90±1.70 mlu/mt). The level of T3 in diabetic males (125±97ng/ml) was higher than the level in females (98±75ng/dl). TSH (F=2.74, p=0.049), T4(F=56.87, p=0.001), T3(F=56.44, P=0.001) in diabetics and FT4 (F=5.74, p=0.002) in controls showed significant variation with the ages of the subjects. Out of 161 diabetics subjects studies 26.6% had low plasma thyroid hormone levels (FT4>2.01 ng/dl). This study has shown a high incidence (46.5%) of abnormal thyroid hormone levels among the diabetics in Nigeria (hypothyroidism 26.6%, hyperthyroidism, 19.9%). The prevalence of hypothyroidism was higher in women (16.8%) than in men (9.9%), while hyperthyroidism was higher in males (11%) than in females (8%). This study has defined thyroid function status of diabetics in Calabar, Nigeria probably the first of such work in Africa.  相似文献   

3.
Thyroid hormonal status was measured in 80 malnourished children of different grades (I–IV) of protein energy malnutrition (PEM). Serum levels of tri-iodo thyronine (T3), thyroxine (T4) and thyroid stimulating hormone (TSH) were measured by radioimmunoassay. The results were compared with 20 healthy, age and sex matched controls. Levels of T3 and T4 were significantly low in PEM cases whereas TSH levels were similar in PEM cases when compared to controls.  相似文献   

4.
The aim of this study is to delineate laboratory diagnostic strategies for subclinical hypothyroidism in patients who are clinically symptomatic but may have a normal thyroid profile. Tri — iodothyronine (T3), thyroxine (T4), thyroid stimulating hormone (TSH) and anti thyroid peroxidase antibodies (anti-TPO) were estimated on fasting blood samples from 99 patients using electrochemiluminescence methods on ELECSYS 1010 (Roche). 74% of study subjects had elevated anti-TPO levels.61% patients had subclinical hypothyroidism. 45 of the 61 subclinical hypothyroid patients had elevated anti-TPO levels (73%). This is an important finding suggesting an autoimmune etiology for subclinical thyroid dysfunction with a higher risk of developing overt hypothyroidism.  相似文献   

5.
Hormones play an important role in the digestive system. The main hormones that control digestion are gastrin, secretin, and cholecystokinin. Herein, the current study is concerned with assessing the effect of spasmo canulase and librax drugs on the human hormones profile. Blood samples were withdrawn from adult patients to measure serum FSH, E2, LH, prolactin, progesterone, DHEAS, testosterone, TSH, T3, T4, fasting insulin, and cortisol. All hormone concentrations were determined quantitatively using ELISA procedure. Intriguingly, the present study showed putative changes including thyroid and sex hormonal profiles. Eventually, we concluded that the prospective study could be important in drug dose optimization and providing new medical guidelines to avoid side effects that could harm patients.  相似文献   

6.
The effect of iodine deficiency (ID) on thyroid function in African women during pregnancy and postnatal period was examined, for which very limited information is available. Serum T4, T3, TSH, TBG, thyroxine binding capacity (TBK), free thyroxine index (FT4I=T4/TBK) and T4/TBG were determined by ELISA technique in 32 pregnant women (resident of Plateau state, Nigeria- an ID zone) through pregnancy upto term delivery, and in 5 women up to 6 weeks post delivery. Urinary iodide level was measured at delivery to determine the degree of iodine deficiency. Results were matched with a non pregnant control comprising 44 subjects. 5555 birth weights (BW) of term babies in the region were analysed to determine the prevalence of ‘small for dates’ (SFD) babies in the population. Results show that the level of serum FT4I was elevated very significantly at late gestation (P<.001) but the women were not hyperthyroid, suggesting a marked disturbance in binding of T4 with TBG during pregnancy. Five women with SFD babies were found in ‘compensated hypothyroid state’ and showed a significant depression (p<.01) in serum T4/TBG, T4, FT4I and T3 levels to a low normal range, with a concurrent significant rise (p.<.001) in TSH level (above normal range) throughout pregnancy. Incidence of SFD babies was higher (p.<.001) in ID zone (Bassa 15.2%) compared to control zone (Jos 9.8%). It is concluded that a state of maternal ‘subclinical (compensated) hypothyroidism’ during pregnancy possibly plays an important role in the aetiopathogenesis of SFD babies in Africans. A normal reference range for thyroid parameters at various stages of pregnancy in healthy African women is established for the first time.  相似文献   

7.
Graves’ disease (GD) is an organ-specific heterogenous autoimmune disorder associated with T-lymphocyte abnormality affecting the thyroid, eyes and skin. GD is a multifactorial disease that develops as a result of complex interaction between genetic susceptibility genes and environmental factors. It has been suggested that the Cytotoxic T lymphocytes associated molecule-4 (CTLA-4) is a genetic susceptibility candidate for GD. The present study was focused on A/G polymorphism at position 49 in exon-1 of the CTLA-4 gene in 80 GD patients (GP) and 80 sex and age matched healthy individuals among South Indian (Madurai) population. Serum concentrations of thyroid hormone (T4, T3 and TSH) were determined by using automated analyzer. The genomic DNA was isolated from the patient and control groups and genotyping was performed using the polymerase chain reaction followed by restriction enzyme analysis using Bbv1. Significant difference (P < 0.001) was observed in the level of T3, T4 and TSH in GD patients and healthy individuals. The results revealed the CTLA-4 gene G/G genotype to be 32 (40%) in patients and 26 (32.50%) in healthy individuals, A/G genotype to be 37 (46.25%) in patients and 25 (31.25%) in healthy individuals and A/A genotype to be 11 (13.75%) in patients and 29 (36.25%) in healthy individuals. The calculated odds ratio (OR) in individuals with mutant genotype (GG/AG) reveal 3.6 fold risk for GD (95% confidence interval = 1.6–7.8). The mutant “G” allele frequency was observed to be 0.63 in GD patients and 0.48 in healthy individuals. Thus the present study demonstrates an association between the CTLA-4 gene polymorphism and Graves’ disease.  相似文献   

8.
Study was undertaken to assess thyroid status in hyperemesis gravidarum. 150 women pregnant with <20 weeks of gestation were selected randomly and out of these 100 women presenting with hyperemesis formed study group while 50 normal pregnant women served as controls. 53% of hyperemetic pregnant women were primigravidae and 82% of pregnant women presented with vomiting at less than 12 weeks of gestation. Statistically significant, 22% of hyperemetic women had increased serum T3 levels while T4 levels were increased in 67% of women in study group as compared to 8% and 16% respectively in control group. TSH levels were decreased in 18% of hyperemetic women as compared to 8% in control group with decrease in mean TSH level statistically significant. 22% of hyperemetic women had electrolyte disturbances and 7% were ketonuric. In clinically euthyroid women, biochemically altered thyroid function can attribute to vomiting and its prolongation to second trimester  相似文献   

9.
Pregnancy is associated with significant, but reversible changes in thyroid function studies, which are among the most profound seen as a result of a normal physiologic state. The present study was carried out to find out alterations in thyroid function tests in each trimester in normal pregnant women as compared to non-pregnant women in Tabriz-Iran. A case-control study designed with 229 normal pregnant women that randomly selected from the first (64 samples), the second (92 samples), and the third (73 samples) trimesters and 250 randomly selected non-pregnant healthy female controls. Age range in both groups was 16–40 years. Thyroid function tests carried out by measuring serum levels of thyroid stimulating hormone (TSH), free and total thyroxin (FT4, TT4), and free and total triiodothyronine (FT3, TT3) by commercially available radio immunoassay kits. We found that mean TT4 increased progressively during pregnancy. Our study showed increasing in serum levels of TT3 in the second trimester and then declining during the third trimester compared with non-pregnant women. We showed that FT4 strongly decreased during the third trimester. Free T3 showed declining in the second and third trimesters. Mean TSH did not show significant difference in each trimester compared with non-pregnant women. The thyroid function tests in pregnancy should be interpreted against gestational age-related reference intervals to avoid mis-interpretation of thyroid function during pregnancy.  相似文献   

10.
Thyroid hormones regulate the renal hemodynamics and basal metabolic rate of most cells. This hospital-based case-control study was done to evaluate the changes in biochemical markers of liver and kidney function in hypothyroid subjects before and after treatment. The study included 176 subjects randomly selected from Thyroid clinics. Serum T3, T4, TSH, Liver and Kidney Function tests were analysed using standard kits. Forty-six hypothyroid patients were re-evaluated 6 weeks after thyroxine substitution therapy. Hypothyroid subjects (n=80) showed significantly raised serum creatinine and uric acid levels as compared to euthyroid subjects (n=96). After 6 weeks of thyroxine replacement, serum creatinine and uric acid decreased significantly and were comparable to euthyroid group. A positive correlation of ALT, AST, uric acid, protein and albumin with TSH levels (p<0.05) and negative correlation of serum T4 levels with ALT, AST, proteins (p<0.05) was observed in the hypothyroid group. Hypothyroidism results in reversible impairment of hepatorenal function.  相似文献   

11.
Thyroid stimulating hormone (TSH), Free Thyroxine (FT4) and Free Triiodothyronine (FT3) were assayed in 505 women of this region. 60 women had previous history of thyroid disease. The remaining 445 women formed the “Disease free group”. A “Reference group” was obtained by excluding women with previous and present history of thyroid dysfunction. Of the total 505 women examined 15.8% had thyroid dysfunction and 84.2% were euthyroid. 11.5% were hypothyroid (9.5% sub-clinical) and 1.8% hyperthyroid (1.2% clinical). The geometric mean TSH for the total population was 2.65 μIU/ml. It was significantly (p=0.025) lower in the reference population 2.17 μIU/ml. There was no significant difference in the FT3 and FT4 values between groups. 19% of women over 60 years had elevated TSH above 4.5 μIU/ml. The 2.5 and 97.5 percentiles of the reference population was 1.1–5.2 μIU/ml. 6.1% of women in the reference group had TSH levels above the reference intervals. Hypothyroidism particularly sub-clinical hypothyroidism is predominantly present amongst women in this iodine sufficient region. Evaluation of thyroid status could help in early detection and treatment.  相似文献   

12.
The role of triodothyronine (T3 in regulating thyroid function is paramount in that at cellular level it interacts with receptors in the nucleus and thereby modulates gene expression. The multiple steps in the processing of lodide by the thyroid gland is under the influence of the thyroid stimulating hormone (TSH). In terms of laboratory evaluation of thyroid function the primary test is TSH. To discriminate between hypothalamic and pitutary dysfunction, the thyroid releasing hormone (TRH) stimulation test is useful. Currently used 2-site Immunometric procedures that employ mouse monoclonal antibodies can be subject to Interference by heterophlle antibodies in patient's serum. Drugs and other extraneous substances can influence the results obtained in some thyroid function tests. Thyroid dysfunction could also be due to autoimmune disease. The limitations of the usefulness of thyroid function tests in non-thyroidal illness should be kept in perspective. In conclusion, the proper interpretation of results of thyroid function tests depends on the sound understanding of concepts of thyroid function and variables affecting laboratory testing.  相似文献   

13.
Serum thyroglobulin (Tg) and thyroid stimulating hormone (TSH) measurements have evolved as important analytes for monitoring the prognosis of patients with differentiated thyroid cancer, post-thyroidectomy. Individual analyte immunoassay is the current practice in clinical pathology, but the simultaneous assay for all relevant analytes for a given disease, can reduce assay costs, improve patient compliance and give the clinician more information for an unequivocal diagnosis. Microarray immunoassay (MI) can achieve this goal and, hence, we have developed and validated a immuno-radiometric MI for quantitation of serum TSH and Tg by using highly micro-porous polycarbonate (PC) track-etched membranes (TEM) to immobilize the monoclonal anti-TSH and polyclonal anti-Tg antibodies in ~1 mm diameter spots. Non-competitive immunoassays were performed using mixture of 125I labeled monoclonal anti-TSH and anti-Tg antibodies. Phosphorimager was used to quantify the bound radioactivity. TSH and Tg were detected with detection limit of 0.07 µIU/ml and 0.13 ng/ml respectively, which is lower than the clinically required cut-off level. The assay showed: acceptable intra-assay precision within 20 % and recovery in the range of 76–111.2 %. MI compared well with the established immunoradiometric assay (IRMA) with r = 0.98, p < 0.01 (n = 41). No cross-reactivity was seen between the immobilized antibodies. Although two hormones are addressed in this report, MI using PC TEM and isotopic/non-isotopic tracers has the potential for highly automated multiplexed analysis.  相似文献   

14.
The implications of subclinical hypothyroidism (SCH) are many amongst which the most important is progression to overt hypothyroidism. Other debatable aspects are its association with cardiovascular risk, neuromuscular and psychiatric dysfunction, increased predisposition to developing metabolic syndrome and an underlying pro-inflammatory state. We aimed to study the lipid profile, lipoprotein(a) [Lp(a)] and hsCRP levels and insulin resistance in a group of patients with SCH in a referral hospital and see if any significant differences exist between them and euthyroids. This is a case–control study where the selection of controls and cases was based on the thyroid profile. Subjects were selected on their visit to clinical biochemistry lab for thyroid function tests. 33 euthyroids were taken as controls (Group I) and 38 patients comprising of subclinical hypothyroids were grouped as cases (Group II). Serum thyroid stimulating hormone (TSH) was in the range of 0.5–5.0 mIU/L for euthyroids and for subclinical hypothyroids the concentration of TSH was more than 5 mIU/L. The concentration of tri-iodothyronine (T3) and thyroxine (T4) were in normal reference range in both the groups. Individual lipid profile parameters failed to show a significant p value between cases and controls. The LDL/HDL ratio was highly significant (p value < 0.0001) and hsCRP was also statistically between the two groups (p value = 0.0054). Lp(a) and insulin resistance did not differ significantly. SCH is a common disorder that frequently progresses to overt hypothyroidism. This study underlines the importance of LDL/HDL ratio rather than measurement of individual lipid profile parameters in bringing to light the dyslipidemic state associated with SCH. Moreover the use of hsCRP to detect an underlying pro-inflammatory state in SCH can also be emphasized.  相似文献   

15.
Reference intervals (RIs) of serum thyroid stimulating hormone (TSH) and free thyroxine (fT4) were determined in 402 healthy pregnant women by enzyme-linked immunosorbent assay (ELISA) technique after partitioning them into three trimesters. The reference population was chosen from a study population of 610 pregnant females by applying strict inclusion and exclusion criteria. The assays were done using proper quality control measures. RIs were calculated from the central 95 % of the distribution of TSH and fT4 values located between the lower reference limit of 2.5 percentile and upper reference limit of 97.5 percentile value 0.90 confidence intervals for the upper and lower reference limits were also determined. The reference intervals for TSH were 0.25–3.35 μIU/ml for the first trimester; 0.78–4.96 μIU/ml for the second trimester and 0.89–4.6 μIU/ml for the third trimester. Similarly, the reference intervals for fT4 for first, second and third trimesters were 0.64–2.0, 0.53–2.12 and 0.64–1.98 ng/dl respectively. The values thus obtained varied from those provided by the kit literature. In comparison to our derived reference intervals, the reference data from kit manufacturer under-diagnosed both subclinical hypo- and hyper-thyroidism within our pregnant reference population.  相似文献   

16.
IntroductionEvaluation of thyroid function is often requested and therefore defining paediatric reference intervals (RIs) is of vital importance. Currently, there is a distinct lack of paediatric RIs for thyroid function tests in Croatia. Thus, we established RIs for thyroid stimulating hormone (TSH), total triiodothyronine (TT3), total thyroxine (TT4), free triiodothyronine (FT3) and free thyroxine (FT4) in the Croatian paediatric population.Materials and methodsReference intervals were calculated from 397 apparently healthy children, aged from 2 days to < 19 years. Serum samples were analysed for thyroid function tests on the Abbott Architect i2000. Age- and sex-specific 95% RIs with 90% confidence intervals were established according to Clinical and Laboratory Standards Institute guidelines. To express the magnitude of sex and age variation, standard deviation ratio (SDR) was calculated using two-level nested ANOVA. The criterion for considering partitioning reference values was set to SDR > 0.3.ResultsAll thyroid function tests required age partitioning, confirmed by SDR above 0.3. There was no need for sex partitioning, confirmed by SDR below 0.3. Still, FT3 was partitioned due to visually noticeable sex related difference for the oldest group (12 years to < 19 years).ConclusionThis is the first study to establish RIs for thyroid function tests in the Croatian paediatric population. We propose RIs for widely used Abbott platform, thus giving laboratories method- and population-specific paediatric RIs for thyroid function tests that should improve clinical test interpretation.  相似文献   

17.
An audit of 2509 patient specimens analyzed for both total thyroxine (TT4) and free thyroxine (FT4) by the ACS-180 automated chemiluminescence immunoassay analyzer revealed that there were 219 discrepancies (8.7% of the total). A discrepancy was defined as one analyte within its reference range and the other outside. The discrepant results were divided into 4 groups: group A: normal TT4, but decreased FT4, 101 patients (4.0%); group B: increased TT4, normal FT4, 78 patients (3.1%); group C: decreased TT4, normal FT4, 34 patients (1.4%); and group D: normal TT4, increased FT4, 6 patients (0.2%). TSH measurements were available, by a 3rd generation chemiluminescent assay, in 142 of these patients, and were consistent with the FT4 result in 72 patients, with TT4 in 61 cases and with neither in 9 patients. The clinical diagnosis was investigated in a subgroup of 43 endocrine patients. Thirteen of the 20 endocrine patients in group A were diagnosed as hypothyroid, with a measured serum TSH, in 11 of them, of median 14.6, range 1.2 to 46.2 μlU/ml. Eleven of the 19 endocrine patients in group B were on thyroid replacement, with a measured serum TSH, in 7 of them of <0.01 μlU/ml. The audit of current laboratory practice led to a suggestion to replace the current thyroid function screening strategy of measuring both TT4 and FT4 by the combination of FT4 and TSH. The reasons for the discrepancies and the alternative strategies for screening of thyroid function are discussed.  相似文献   

18.
IntroductionIt is common for patients to switch between several healthcare providers. In this context, the long-term follow-up of medical conditions based on laboratory test results obtained from different laboratories is a challenge. The measurement uncertainty in an inter-laboratory context should also be considered in data mining research based on routine results from randomly selected laboratories. As a proof-of-concept study, we aimed at estimating the inter-laboratory reference change value (IL-RCV) for exemplary analytes from publicly available data on external quality assessment (EQA) and biological variation.Materials and methodsExternal quality assessment data of the Reference Institute for Bioanalytics (RfB, Bonn, Germany) for serum creatinine, calcium, aldosterone, PSA, and of whole blood HbA1c from campaigns sent out in 2019 were analysed. The median CVs of all EQA participants were calculated based on 8 samples from 4 EQA campaigns per analyte. Using intra-individual biological variation data from the EFLM database, positive and negative IL-RCV were estimated with a formula based on log transformation under the assumption that the analytes under examination have a skewed distribution.ResultsWe estimated IL-RCVs for all exemplary analytes, ranging from 13.3% to 203% for the positive IL-RCV and - 11.8% to - 67.0% for the negative IL-RCV (serum calcium - serum aldosterone), respectively.ConclusionExternal quality assessment data together with data on the biological variation – both freely available – allow the estimation of inter-laboratory RCVs. These differ substantially between different analytes and can help to assess the boundaries of interoperability in laboratory medicine.  相似文献   

19.

Introduction

Recently several diagnostic manufacturers have launched new 25-hydroxy-vitamin D (25[OH]D) assays, which are aligned to the National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) (NIST, Gaithersburg, Maryland). The aim of this study was to compare the performance of one liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, one enzyme linked immunosorbent assay (ELISA), and one recalibrated and previous version of a chemiluminescence immunoassay (CLIA).

Material and methods

Serum-aliquots of 198 patient samples from routine 25(OH)D analysis were measured by the ClinMass® LC-MS/MS Complete Kit (RECIPE Chemicals + Instruments GmbH, Munich, Germany), the ORGENTEC 25(OH)D3/D2 ELISA (ORGENTEC Diagnostika GmbH, Mainz, Germany), the recalibrated Immunodiagnostic Systems (IDS)-iSYS 25(OH)DS and the previous used IDS-iSYS 25(OH)D CLIA (Immunodiagnostic Systems Ltd, Boldon, United Kingdom). Bland-Altman and Deming regression analyses were calculated for methods comparison of all tested 25(OH)D assays. The LC-MS/MS method was defined as the reference method. Within-run and between-run precision measurements were performed for all methods with three different concentration levels.

Results

Compared to the LC-MS/MS method, the new IDS-iSYS 25(OH)DS and ORGENTEC 25(OH)D3/D2 assay demonstrated mean relative biases of 16.3% and 17.8%. The IDS-iSYS 25(OH)D assay showed the lowest mean bias of 1.5%. Deming regression analyses of the recalibrated IDS-iSYS 25(OH)DS and the ORGENTEC 25(OH)D3/D2 assay showed proportional differences, when compared to the reference method. All assays showed a within-run and between-run imprecision of ≤ 20% at each of the evaluated concentration levels.

Conclusions

The evaluated standardized immunoassays and LC-MS/MS are useful methods for measuring 25(OH)D serum-levels in clinical laboratories.Key words: vitamin D, immunoassays, liquid chromatography-tandem mass spectrometry, reference standards, quality improvement  相似文献   

20.
Diabetes mellitus and thyroid disorders are common endocrinopathies, which often occur parallel. Dyslipidemia is very common in both of these conditions. The development of hypothyroidism is well-known in type 1 diabetics, but it was not distinctly understood in type 2 diabetics. Thus we tried to examine the association between type II deiodinase (D2 or DIO2) Thr92Ala single nucleotide gene polymorphism and thyroid function among type 2 diabetes mellitus patients. A total of 130 type 2 diabetics were screened and genotyped for DIO2 Thr92Ala polymorphism. Fasting plasma glucose, Glycosylated haemoglobin, lipid and thyroid profiles, malondialdehyde (MDA) and paraoxonase were estimated according to standard procedures. A significant altered level of thyroid hormones (TH’s) was found in Ala/Ala genotype when compared with Thr/Thr or Thr/Ala genotype. DIO2 and T3:T4 ratio significantly decreased, whereas total T4 and thyroid stimulating hormone levels significantly elevated among Ala/Ala genotype (131 ± 30 ng/ml; 0.12 ± 0.05; 7.17 ± 2.05 µg/dl; 4.77 ± 3.1 µIU/ml, respectively) when compared with Thr/Thr + Thr/Ala genotypes (176 ± 33 ng/ml; 0.21 ± 0.05; 5.21 ± 1.1 µg/dl; 2.59 ± 1.61 µIU/ml respectively). Moreover, D2 levels were significantly negatively correlated with TH’s levels except total T4 among Ala/Ala genotypes. All the patients were having a poor glycemic control, and their glycemic status was positively correlating with MDA levels. On the other hand, serum paraoxonase activity decreased among Ala/Ala genotype (104 ± 21 vs. 118 ± 18 nmol/min/ml). In conclusion, DIO2 Ala92 homozygous variant found to be associated with altered levels of DIO2, Thyroid profile and paraoxonase. Hence, we recommend to do detail study of genetic factors related to thyroid function and prevent additional diabetic complications.  相似文献   