首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 91 毫秒
1.
ABSTRACT

This study aimed to compare mechanical variables derived from torque-cadence and power-cadence profiles established from different cycle ergometer modes (isoinertial and isokinetic) and modelling procedures (second- and third-order polynomials), whilst employing a novel method to validate the theoretical maximal power output (Pmax). Nineteen well-trained cyclists (n = 12 males) completed two experimental sessions comprising six, 6-s maximal isoinertial or isokinetic cycling sprints. Maximal pedal strokes were extracted to construct power–cadence relationships using second- and third-order polynomials. A 6-s sprint at the optimal cadence (Fopt) or optimal resistance (Topt) was performed to assess construct validity of Pmax. No differences were found in the mechanical parameters when derived from isokinetic (Pmax = 1311 ± 415, Fopt = 118 ± 12) or isoinertial modes (Pmax = 1320 ± 421, Fopt = 116 ± 19). However, R2 improved (P < 0.02) when derived from isoinertial sprints. Third-order polynomial modelling improved goodness of fit values (Standard Error, adjusted R2), but derived similar mechanical parameters. Finally, peak power output during the optimised sprint did not significantly differ from the theoretical Pmax in both cycling modes, thus providing construct validity. The most accurate P-C profile can be derived from isoinertial cycling sprints, modelled using third-order polynomial equations.  相似文献   

2.
Abstract

We examined the effect of recovery pattern on mechanical and neuromuscular responses in active men during three repeated-sprint ability tests consisting of ten 6-s cycling sprints. Within each test, the recovery duration was manipulated: constant, increasing, and decreasing recovery pattern. Maximal voluntary contractions of the knee extensors were performed before and after the repeated-sprint ability tests to assess strength and electromyographic activity [root mean square (RMS)] of the quadriceps muscle. We observed different fatigue patterns for peak and mean power output between recovery patterns, with earlier decrements recorded during the increasing recovery pattern. Total work performed over the ten sprints was also lower in the increasing recovery pattern (43.8 ± 5.4 kJ; P < 0.05). However, the decreasing recovery pattern induced a greater overall power output decrement across the sprints (?15.8%; P < 0.05), compared with the increasing recovery pattern (?5.1%) but not the constant recovery pattern (?10.1%). The decreasing recovery pattern was also associated with higher post-sprint RMS values (+16.2%; P < 0.05). Therefore, the recovery pattern within successive short sprints may influence repeated-sprint ability, and may lead to greater post-sprint neuromuscular adjustments when recovery intervals decrease between sprints. We conclude that peripheral impairments caused the major differences in repeated-sprint ability between recovery patterns.  相似文献   

3.
Abstract

Seven 6 s sprints with 30 s recovery between sprints were performed against two resistive loads: 50 (L50) and 100 (L100) g · kg?1 body mass. Inertia-corrected and -uncorrected peak and mean power output were calculated. Corrected peak power output in corresponding sprints and the drop in peak power output relative to sprint 1 were not different in the two conditions, despite the fact that mean power output was 15–20% higher in L100 (P < 0.01). The effect of inertia correction on power output was more pronounced for the lighter load (L50), with uncorrected peak power output in sprint 1 being 42% lower than the corresponding corrected peak power output, while this was only 16% in L100. Fatigue assessed by the drop in uncorrected peak and mean power output in sprint 7 relative to sprint 1 was less compared with that obtained by corrected power values, especially in L50 (drop in uncorrected vs. corrected peak power output: 13.3 ± 2.2% vs. 23.1 ± 4.1%, P < 0.01). However, in L100, the difference between the drop in corrected and uncorrected mean power output in sprint 7 was much smaller (24.2 ± 3.1% and 21.2 ± 2.7%, P < 0.01), indicating that fatigue may be safely assessed even without inertia correction when a heavy load is used. In conclusion, when inertia correction is performed, fatigue during repeated sprints is unaffected by resistive load. When inertia correction is omitted, both power output and the fatigue profile are underestimated by an amount dependent on resistive load. In cases where inertia correction is not possible during a repeated sprints test, a heavy load may be preferable.  相似文献   

4.
Attenuated performance during intense exercise with limited endogenous carbohydrate (CHO) is well documented. Therefore, this study examined whether caffeine (CAF) mouth rinsing would augment performance during repeated sprint cycling in participants with reduced endogenous CHO. Eight recreationally active males (aged 23?±?2?yr, body mass 84?±?4?kg, stature 178?±?7?cm) participated in this randomized, single-blind, repeated-measures crossover investigation. Following familiarization, participants attended two separate evening glycogen depletion sessions. The following morning, participants completed five, 6?s sprints on a cycle ergometer (separated by 24?s active recovery), with mouth rinsing either (1) a placebo solution or (2) a 2% CAF solution. During a fifth visit, participants completed the sprints without prior glycogen depletion. Repeated-measures ANOVA identified significant main effect of condition (CAF, placebo, and control [P?P?P?P?P?P?相似文献   

5.
Abstract

This study examined the effect of two different interval training programs–high-intensity interval training (HIT) and supramaximal interval training (SMIT)–on measures of sprint and endurance performance. Physically active individuals (Females: n=32; age 19.3, s=2.2 years; mass 67.6, s=9.1 kg; stature 172.7, s=6.6 cm. Males: n=23; age 20.0, s=2.7 years; mass 71.3, s=8.3 kg; stature 176.6, s=5.8 cm) completed pre-testing that comprised (1) 3000 m time-trial, (2) 40 m sprint, and (3) repeated sprint ability (RSA–6×40 m sprints, 24 s active recovery) performance. Participants were then matched for average 3000 m running velocity (AV) and randomly assigned to one of three groups: (i) HIT, n=19, 4 min at 100% AV, 4 min passive recovery, 4–6 bouts per session; (ii) SMIT, n=20, 30 s at 130% AV, 150 s passive recovery, 7–12 bouts per session; and (iii) control group, n=16, 30 min continuous running at 75% AV. Groups trained three times per week for six weeks. When time to complete each test were compared among groups: (i) improvements in 3000 m time trial performance were greater following SMIT than continuous running, and (ii) improvements in 40 m sprint and RSA performance were greater following SMIT than HIT and continuous running. In addition, a gender effect was observed for the 3000 m time trial only, where females changed more following the training intervention than males. In summary, for concurrent improvements in endurance, sprint and repeated sprint performance, SMIT provides the greatest benefits for physically active individuals.  相似文献   

6.
Abstract

Thirty-eight competitive cross-country skiers were divided into three groups to assess the reliability and validity of a new double poling ergometer. Group A (n = 22) performed two maximal 60-s tests, Group B (n = 8) repeated peak oxygen uptake tests on the double poling ergometer, and Group C (n = 8) performed a maximal 6-min test on the double poling ergometer and a double poling time-trial on snow. The correlation between the power calculated at the flywheel and the power applied at the base of the poles was r = 0.99 (P < 0.05). The power at the poles was 50 – 70% higher than that at the flywheel. There was a high test – retest reliability in the two 60-s power output tests (coefficient of variation = 3.0%) and no significant difference in peak oxygen uptake in the two 6-min all-out tests (coefficient of variation = 2.4%). There was a strong correlation between the absolute (W) and relative power (W · kg?1) output in the 6-min double poling ergometer test and the double poling performance on snow (r = 0.86 and 0.89 respectively; both P < 0.05). In conclusion, our results show that the double poling ergometer has both high reliability and validity. However, the power calculated at the flywheel underestimated the total power produced and needs to be corrected for in ergonomic estimations.  相似文献   

7.
Abstract

In this study, we evaluated the effects of a novel pedal design, characterized by a downward and forward shift of the cleat fixing platform relative to the pedal axle, on maximal power output and mechanical efficiency in 22 well-trained cyclists. Maximal power output was measured during a series of short (5-s) intermittent sprints on an isokinetic cycle ergometer at cadences from 40 to 120 rev · min?1. Mechanical efficiency was evaluated during a submaximal incremental exercise test on a bicycle ergometer using continuous [Vdot]O2 and [Vdot]CO2 measurement. Similar tests with conventional pedals and the novel pedals, which were mounted on the individual racing bike of the participant, were randomized. Maximal power was greater with novel pedals than with conventional pedals (between 6.0%, sx  = 1.5 at 40 rev · min?1 and 1.8%, sx  = 0.7 at 120 rev · min?1; P = 0.01). Torque production between crank angles of 60° and 150° was higher with novel pedals than with conventional pedals (P = 0.004). The novel pedal design did not affect whole-body [Vdot]O2 or [Vdot]CO2. Mechanical efficiency was greater with novel pedals than with conventional pedals (27.2%, sx  = 0.9 and 25.1%, sx  = 0.9% respectively; P = 0.047; effect size = 0.9). In conclusion, the novel pedals can increase maximal power output and mechanical efficiency in well-trained cyclists.  相似文献   

8.
Abstract

The present study aimed to analyse the influence of speed and power abilities in goal situations in professional football.

During the second half of the season 2007/08, videos of 360 goals in the first German national league were analysed by visual inspection. For the assisting and the scoring player the situations immediately preceding the goal were evaluated. The observed actions were categorised as: no powerful action, rotation (around the body's centre-line), straight sprint, change-in-direction sprint, jump, or a combination of those categories.

Two hundred and ninety-eight (83%) goals were preceded by at least one powerful action of the scoring or the assisting player. Most actions for the scoring player were straight sprints (n = 161, 45% of all analysed goals, P < 0.001) followed by jumps (n = 57, 16%), rotations and change-in-direction sprints (n = 22, 6% each). Most sprints were conducted without an opponent (n = 109, P < 0.001) and without the ball (n = 121, P < 0.001). Similarly, for the assisting player the most frequent action was a straight sprint (n = 137, P < 0.001) followed by rotations (n = 28), jumps (n = 22) and change-in-direction sprints (n = 18). The straight sprints were mostly conducted with the ball (n = 93, P = 0.003).

In conclusion, straight sprinting is the most frequent action in goal situations. Power and speed abilities are important within decisive situations in professional football and, thus, should be included in fitness testing and training.  相似文献   

9.
The aim of this study was to compare the training effects based on repeated sprint ability (RSA) (with one change of direction) with an intensive repeated sprint ability (IRSA) (with two changes of direction) on jump performance and aerobic fitness. Eighteen male basketball players were assigned to repeated sprint ability and intensive repeated sprint ability training groups (RSAG and IRSAG). RSA, IRSA, squat jump (SJ), countermovement jump (CMJ) and Yo-Yo intermittent recovery level 1 test were assessed before and after four training weeks. The RSA and IRSA trainings consisted of three sets of six sprints (first two weeks) and eight sprints (second two weeks) with 4-min sets recovery and 20-s of sprints recovery. Four weeks of training led to an overall improvement in most of the measures of RSA, but little evidence of any differences between the two training modes. Jump performance was enhanced: CMJ of 7.5% (< 0.0001) and 3.1% (= 0.016) in IRSAG and RSAG respectively. While SJ improved of 5.3% (= 0.003) for IRSAG and 3.4% (= 0.095) for RSAG. Conversely the Yo-Yo distance increased 21% (= 0.301) and 34% (= 0.017) in IRSAG and RSAG respectively. Therefore, short-term repeated sprint training with one/two changes of direction promotes improvements in both RSA and IRSA respectively but the better increase on jump performance shown a few changes on sprint and endurance performances.  相似文献   

10.
This assessor-blinded, randomized controlled superiority trial investigated the efficacy of the 10-week Nordic Hamstring exercise (NHE) protocol on sprint performance in football players.

Thirty-five amateur male players (age: 17–26 years) were randomized to a do-as-usual control group (CG; n = 17) or to 10-weeks of supervised strength training using the NHE in-season (IG; n = 18). A repeated-sprint test, consisting of 4 × 6 10 m sprints, with 15 s recovery period between sprints and 180 s between sets, was conducted to evaluate total sprint time as the primary outcome. Secondary outcomes were best 10 m sprint time (10mST) and sprint time during the last sprint (L10mST). Additionally, peak eccentric hamstring strength (ECC-PHS) and eccentric hamstring strength capacity (ECC-CAPHS) were measured during the NHE.

Ten players were lost to follow-up, thus 25 players were analyzed (CG n = 14; IG n = 11). Between-group differences in mean changes were observed in favor of the IG for sprint performance outcomes; TST (?0.649 s, p = 0.056, = 0.38), 10mST (?0.047 s, p = 0.005, = 0.64) and L10mST (?0.052 s, p = 0.094, = 0.59), and for strength outcomes; ECC-PHS (62.3 N, p = 0.006, = 0.92), and ECC-CAPHS (951 N, p = 0.005, = 0.95).

In conclusion, the NHE showed small-to-medium improvements in sprint performance and large increases in peak eccentric hamstring strength and capacity.

Trial Registration Number: NCT02674919  相似文献   

11.
Abstract

The aim of this study was to compare optimization and correction procedures for the determination of peak power output during friction-loaded cycle ergometry. Ten male and 10 female sports students each performed five 10-s sprints from a stationary start on a Monark 864 basket-loaded ergometer. Resistive loads of 5.0, 6.5, 8.0, 9.5, and 11.0% body weight were administered in a counterbalanced order, with a recovery period of 10 min between sprints. Peak power was greater and occurred earlier, with less work having been done before the attainment of peak power, when the data were corrected to account for the inertial and frictional characteristics of the ergometer. Corrected peak power was independent of resistive load (P > 0.05), whereas uncorrected peak power varied as a quadratic function of load (P < 0.001). For males and females, optimized peak power (971 ± 122 and 668 ± 37 W) was lower (P < 0.01) than either the highest (1074 ± 111 and 754 ± 56 W respectively) or the mean (1007 ± 125 and 701 ± 45 W respectively) of the five values for corrected peak power. Optimized and mean corrected peak power were highly correlated both in males (r = 0.97, P < 0.001) and females (r = 0.96, P < 0.001). The difference between optimized and mean corrected peak power was 37 ± 30 W in males and 33 ± 14 W in females, of which approximately 15 W was due to the correction for frictional losses. We conclude that corrected peak power is independent of resistive load in males and females.  相似文献   

12.
ABSTRACT

The aims of this study were to analyse the optimal cadence for peak power production and time to peak power in bicycle motocross (BMX) riders. Six male elite BMX riders volunteered for the study. Each rider completed 3 maximal sprints at a cadence of 80, 100, 120 and 140 revs · min?1 on a laboratory Schoberer Rad Messtechnik (SRM) cycle ergometer in isokinetic mode. The riders’ mean values for peak power and time of power production in all 3 tests were recorded. The BMX riders produced peak power (1105 ± 139 W) at 100 revs · min?1 with lower peak power produced at 80 revs · min?1 (1060 ± 69 W, (F(2,15) = 3.162; P = .266; η2 = 0.960), 120 revs · min?1 (1077 ± 141 W, (F(2,15) = 4.348; P = .203; η2 = 0.970) and 140 revs · min?1 (1046 ± 175 W, (F(2,15) = 12.350; P = 0.077; η2 = 0.989). The shortest time to power production was attained at 120 revs · min?1 in 2.5 ± 1.07 s. Whilst a cadence of 80 revs · min?1 (3.5 ± 0.8 s, (F(2,15) = 2.667; P = .284; η2 = 0.800) 100 revs · min?1 (3.00 ± 1.13 s, (F(2,15) = 24.832; P = .039; η2 = 0.974) and 140 revs · min?1 (3.50 ± 0.88 s, (F(2,15) = 44.167; P = .006; η2 = 0.967)) all recorded a longer time to peak power production. The results indicate that the optimal cadence for producing peak power output and reducing the time to peak power output are attained at comparatively low cadences for sprint cycling events. These findings could potentially inform strength and conditioning training to maximise dynamic force production and enable coaches to select optimal gear ratios.  相似文献   

13.
Rowers need to combine high sprint and endurance capacities. Muscle morphology largely explains muscle power generating capacity, however, little is known on how muscle morphology relates to rowing performance measures. The aim was to determine how muscle morphology of the vastus lateralis relates to rowing ergometer performance, sprint and endurance capacity of Olympic rowers. Eighteen rowers (12♂, 6♀, who competed at 2016 Olympics) performed an incremental rowing test to obtain maximal oxygen consumption, reflecting endurance capacity. Sprint capacity was assessed by Wingate cycling peak power. M. vastus lateralis morphology (volume, physiological cross-sectional area, fascicle length and pennation angle) was derived from 3-dimensional ultrasound imaging. Thirteen rowers (7♂, 6♀) completed a 2000-m rowing ergometer time trial. Muscle volume largely explained variance in 2000-m rowing performance (R2 = 0.85), maximal oxygen consumption (R2 = 0.65), and Wingate peak power (R2 = 0.82). When normalized for differences in body size, maximal oxygen consumption and Wingate peak power were negatively related in males (r = ?0.94). Fascicle length, not physiological cross-sectional area, attributed to normalized peak power. In conclusion, vastus lateralis volume largely explains variance in rowing ergometer performance, sprint and endurance capacity. For a high normalized sprint capacity, athletes may benefit from long fascicles rather than a large physiological cross-sectional area.  相似文献   

14.
The aim of this study was to determine the relationship between force and velocity parameters during a specific multi-articular upper limb movement – namely, hand rim propulsion on a wheelchair ergometer. Seventeen healthy able-bodied females performed nine maximal sprints of 8?s duration with friction torques varying from 0 to 4?N?·?m. The wheelchair ergometer system allows measurement of forces exerted on the wheels and linear velocity of the wheel at 100 Hz. These data were averaged for the duration of each arm cycle. Peak force and the corresponding maximal velocity were determined during three consecutive arm cycles for each sprint condition. Individual force–velocity relationships were established for peak force and velocity using data for the nine sprints. In line with the results of previous studies on leg cycling or arm cranking, the force–velocity relationship was linear in all participants (r?=??0.798 to ?0.983, P?<0.01). The maximal power output (mean 1.28?W?·?kg?1) and the corresponding optimal velocity (1.49?m?·?s?1) and optimal force (52.3?N) calculated from the individual force–velocity regression were comparable with values reported in the literature during 20 or 30?s wheelchair sprints, but lower than those obtained during maximal arm cranking. A positive linear relationship (r?=?0.678, P?<0.01) was found between maximal power and optimal velocity. Our findings suggest that although absolute values of force, velocity and power depend on the type of movement, the force–velocity relationship obtained in multi-articular limb action is similar to that obtained in wheelchair locomotion, cycling and arm cranking.  相似文献   

15.
Basketball tests assessing dribbling speed predicated on total performance times are influenced by sprinting speed. This study examines an approach termed Dribble Deficit to counter this limitation by examining the relationships between sprinting and dribbling speed during linear and change-of-direction (COD) tasks measured using total performance time and Dribble Deficit. Ten semi-professional basketball players completed linear sprints and COD sprints with and without dribbling. Dribble Deficit was calculated as the difference between the best time for each dribbling trial and corresponding non-dribbling trial for linear and COD sprints. Large to very large significant relationships (P < 0.05) were evident between linear sprint and dribble times (R = 0.64–0.77, R2 = 0.41–0.59), and between COD sprint and dribble times (R = 0.88, R2 = 0.77). Conversely, trivial-small relationships were evident between linear sprint time and linear Dribble Deficit (R = 0.01–0.15, R2 = 0.00–0.02). A non-significant, moderate, negative relationship was observed between COD sprint time and COD Dribble Deficit (R = ?0.45, R2 = 0.20). These findings indicate Dribble Deficit provides a more isolated measure of dribbling speed than tests using total performance times. Basketball practitioners may use Dribble Deficit to measure dribbling speed independent of sprint speed in test batteries.  相似文献   

16.
ABSTRACT

Participant and protocol factors affect post-activation potentiation response. Performance enhancement is more consistent in highly-trained participants following multiple sets of a biomechanically similar conditioning activity. Providing optimal conditions, 6 international-level sprint cyclists executed multiple sets of short maximal conditioning contractions on a high-inertia ergometer before metered sprint performance. Three trial conditions were completed on separate days after a standardised warm-up: dynamic (DYN: 4 × 4 crank-cycles), isometric (ISO: 4 × 5-sec maximal voluntary contraction (MVC)), and control (CON: rest). Performance was measured from standing start to maximum velocity on an inertial-load ergometer at baseline (Pre), 4 (Post4), 8 (Post8) and 16 (Post16) min post-conditioning. Performance and biomechanical measures were assessed across 4 sprint segments, with magnitude-based inferences used to assess the likelihood that any affect was beneficial. Performance time only improved in DYN Post4, a 3.9% reduction during the first crank cycle (92% likely). On the ascending limb of the power-cadence relationship, peak torque and average power increased by 6.2% (94% likely) and 4.0% (87% likely), respectively. In ISOPost16, optimal cadence increased (82% likely) and average power improved over the descending limb (76% likely). DYN and ISO potentiated extremities of the torque-cadence relationship at distinct recovery times post-conditioning. This study suggests merit in including a high-inertia warm-up for sprint cycling.  相似文献   

17.
Abstract

In this study, we examined the effect of muscle temperature (T m) on adenosine triphosphate (ATP) and phosphocreatine utilization in single muscle fibres during the development of maximal power output in humans. Six male participants performed a 6-s maximal sprint on a friction-braked cycle ergometer under both normal (T m = 34.3°C, s = 0.6) and elevated (T m = 37.3°C, s = 0.2) muscle temperature conditions. During the elevated condition, muscle temperature of the legs was raised, passively, by hot water immersion followed by wrapping in electrically heated blankets. Muscle biopsies were taken from the vastus lateralis before and immediately after exercise. Freeze-dried single fibres were dissected, characterized according to myosin heavy chain composition, and analysed for ATP and phosphocreatine content. Single fibres were classified as: type I, IIA, IIAX25 (1 – 25% IIX isoform), IIAX50 (26 – 50% IIX), IIAX75 (51 – 75% IIX), or IIAX100 (76 – 100% IIX). Maximal power output and pedal rate were both greater (P < 0.05) during the elevated condition by 258 W (s = 110) and 22 rev · min?1 (s = 6), respectively. In both conditions, phosphocreatine content decreased significantly in all fibre types, with a greater decrease during the elevated condition in type IIA fibres (P < 0.01). Adenosine triphosphate content was also reduced to a greater (P < 0.01) extent in type IIA fibres during the elevated condition. The results of the present study indicate that after passive elevation of muscle temperature, there was a greater decrease in ATP and phosphocreatine content in type IIA fibres than in the normal trial, which contributed to the higher maximal power output.  相似文献   

18.
Abstract

In this study, we investigated the age-related differences in repeated-sprint ability and blood lactate responses in 134 youth football players. Players from the development programme of a professional club were grouped according to their respective under-age team (U-11 to U-18). Following familiarization, the participants performed a repeated-sprint ability test [6 × 30-m sprints 30 s apart, with active recovery (2.0–2.2 m · s?1) between sprints]. The test variables were total time, percent sprint decrement, and post-test peak lactate concentration. Total time improved from the U-11 to U-15 age groups (range 33.15 ± 1.84 vs. 27.25 ± 0.82 s), whereas no further significant improvements were evident from U-15 to U-18. No significant differences in percent sprint decrement were reported among groups (range 4.0 ± 1.0% to 5.5 ± 2.1%). Post-test peak lactate increased from one age group to the next (range 7.3 ± 1.8 to 12.6 ± 1.6 mmol · l?1), but remained constant when adjusted for age-related difference in body mass. Peak lactate concentration was moderately correlated with sprint time (r = 0.70, P > 0.001). Our results suggest that performance in repeated-sprint ability improves during maturation of highly trained youth football players, although a plateau occurs from 15 years of age. In contrast to expectations based on previous suggestions, percent sprint decrement during repeated sprints did not deteriorate with age.  相似文献   

19.
Talent identification (TID) and talent development (TDE) programmes in track sprint cycling use ergometer- and track-based tests to select junior athletes and assess their development. The purpose of this study was to assess which tests are best at monitoring TID and TDE. Ten male participants (16.2 ± 1.1 year; 178.5 ± 6.0 cm and 73.6 ± 7.6 kg) were selected into the national TID squad based on initial testing. These tests consisted of two 6-s maximal sprints on a custom-built ergometer and 4 maximal track-based tests (2 rolling and 2 standing starts) using 2 gear ratios. Magnitude-based inferences and correlation coefficients assessed changes following a 3-month TDE programme. Training elicited meaningful improvements (80–100% likely) in all ergometer parameters. The standing and rolling small gear, track-based effort times were likely and very likely (3.2 ± 2.4% and 3.3 ± 1.9%, respectively) improved by training. Stronger correlations between ergometer- and track-based measures were very likely following training. Ergometer-based testing provides a more sensitive tool than track-based testing to monitor changes in neuromuscular function during the early stages of TDE. However, track-based testing can indicate skill-based improvements in performance when interpreted with ergometer testing. In combination, these tests provide information on overall talent development.  相似文献   

20.
Abstract

The purpose of this study was to assess the agreement between two mobile cycle ergometer systems for recording high-intensity, intermittent power output. Twelve trained male cyclists (age 31.4 ± 9.8 years) performed a single 3 min intermittent cycle test consisting of 12 all-out efforts, separated by periods of passive recovery ranging from 5 to 15 s. Power output was recorded using a Polar S710 heart rate monitor and power sensor kit and an SRM Powercrank system for each test. The SRM used torque and angular velocity to calculate power, while the S710 used chain speed and vibration to calculate power. Significant differences (P < 0.05) in power were found at 8 of the 12 efforts. A significant difference (P = 0.001) was also found when power was averaged over all 12 intervals. Mean power was 556 ± 102 W and 446 ± 61 W for the SRM and S710 respectively. The S710 underestimated power by an average of 23% with random errors of ?/÷ 24% when compared with the SRM. Random errors ranged from 36% to 141% with a median of 51%. The results indicate there was little agreement between the two systems and that the Polar S710 did not provide a valid measure of power during intermittent cycling activity when compared with the SRM. Power recorded by the S710 system was influenced greatly by chain vibration and sampling rates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号