首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Purpose: To determine the accuracy of critical power (CP) and W? (the curvature constant of the power-duration relationship) derived from self-paced time-trial (TT) prediction trials using mobile power meters to predict 16.1-km road cycling TT performance. This study also aimed to assess the agreement between functional threshold power (FTP) and CP.

Methods: Twelve competitive male cyclists completed an incremental test to exhaustion, a FTP test and 4–5 self-paced TT bouts on a stationary bike within the lab, and a 16.1 km road TT, using mobile power meters.

Results: CP and W? derived from the power-duration relationship closely predicted TT performance. The 16.1-km road TT completion time (26.7 ± 2.2 min) was not significantly different from and was significantly correlated with the predicted time-to-completion (27.5 ± 3.3 min, = 0.89, < 0.01). CP and FTP were not significantly different (275 ± 40 W vs. 278 ± 42 W, > 0.05); however, the limits of agreement between CP and FTP were 30 to -36 W.

Discussion: The findings of this study indicate that CP and W? determined using mobile power meters during maximal, self-paced TT prediction trials can be used to accurately predict 16.1-km cycling performance, supporting the application of the CP and W? for performance prediction. However, the limits of agreement were too large to consider FTP and CP interchangeable.  相似文献   


2.
ABSTRACT

Elite cyclists have often a limited period of time available during their short preparation phase to focus on development of maximal strength; therefore, the purpose of the present study was to investigate the effect of 10-week heavy strength training on lean lower-body mass, leg strength, determinants of cycling performance and cycling performance in elite cyclists. Twelve cyclists performed heavy strength training and normal endurance training (E&S) while 8 other cyclists performed normal endurance training only (E). Following the intervention period E&S had a larger increase in maximal isometric half squat, mean power output during a 30-s Wingate sprint (P < 0.05) and a tendency towards larger improvement in power output at 4 mmol ? L?1 [la?] than E (P = 0.068). There were no significant difference between E&S and E in changes in 40-min all-out trial (4 ± 6% vs. ?1 ± 6%, respectively, P = 0.13). These beneficial effects may encourage elite cyclists to perform heavy strength training and the short period of only 10 weeks should make it executable even in the compressed training and competition schedule of elite cyclists.  相似文献   

3.
Time-to-exhaustion (TTE) trials are used in a laboratory setting to measure endurance performance. However, there is some concern with their ecological validity compared with time-trials (TT). Consequently, we aimed to compare cycling performance in TTE and TT where the duration of the trials was matched. Seventeen trained male cyclists completed three TTE trials at 80, 100 and 105% of maximal aerobic power (MAP). On a subsequent visit they performed three TT over the same duration as the TTE. Participants were blinded to elapsed time, power output, cadence and heart rate (HR). Average TTE was 865 ± 345 s, 165 ± 98 s and 117 ± 45 s for the 80, 100 and 105% trials respectively. Average power output was higher for TTE (294 ± 44 W) compared to TT (282 ± 43 W) at 80% MAP (P < 0.01), but not at 100 and 105% MAP (P > 0.05). There was no difference in cadence, HR, or RPE for any trial (P > 0.05). Critical power (CP) was also higher when derived from TTE compared to TT (P < 0.01). It is concluded that TTE results in a higher average power output compared to TT at 80% MAP. When determining CP, TTE rather than TT protocols appear superior.  相似文献   

4.
This study examined if short-duration record power outputs can be predicted with the Anaerobic Power Reserve (APR) model in professional cyclists using a field-based approach. Additionally, we evaluated if modified model parameters could improve predictive ability of the model. Twelve professional cyclists (V?O2max 75 ± 6 ml?kg?1?min?1) participated in this investigation. Using the mean power output during the last stage of an incremental field test, sprint peak power output and an exponential constant describing the decrement in power output over time, a power-duration relationship was established for each participant. Record power outputs of different durations (5 to 180 s) were collected from training and competition data and compared to the predicted power output from the APR model. The originally proposed exponent (k = 0.026) predicted performance within an average of 43 W (Standard Error of Estimate (SEE) of 32 W) and 5.9%. Modified model parameters slightly improved predictive ability to a mean of 34–39 W (SEE of 29 – 35 W) and 4.1 – 5.3%. This study shows that a single exponent model generally fits well with the decrement in power output over time in professional cyclists. Modified model parameters may contribute to improving predictability of the model.  相似文献   

5.
Abstract

The purpose of this study was to assess the agreement between two mobile cycle ergometer systems for recording high-intensity, intermittent power output. Twelve trained male cyclists (age 31.4 ± 9.8 years) performed a single 3 min intermittent cycle test consisting of 12 all-out efforts, separated by periods of passive recovery ranging from 5 to 15 s. Power output was recorded using a Polar S710 heart rate monitor and power sensor kit and an SRM Powercrank system for each test. The SRM used torque and angular velocity to calculate power, while the S710 used chain speed and vibration to calculate power. Significant differences (P < 0.05) in power were found at 8 of the 12 efforts. A significant difference (P = 0.001) was also found when power was averaged over all 12 intervals. Mean power was 556 ± 102 W and 446 ± 61 W for the SRM and S710 respectively. The S710 underestimated power by an average of 23% with random errors of ?/÷ 24% when compared with the SRM. Random errors ranged from 36% to 141% with a median of 51%. The results indicate there was little agreement between the two systems and that the Polar S710 did not provide a valid measure of power during intermittent cycling activity when compared with the SRM. Power recorded by the S710 system was influenced greatly by chain vibration and sampling rates.  相似文献   

6.
This study investigated the effect cadence has on the estimation of critical power (CP) and the finite work capacity (W?) during the 3-minute all-out cycling test. Ten participants completed 8 tests: 1) an incremental test to calculate gas exchange threshold (GET), maximal aerobic power (MAP) and peak oxygen uptake (V?O2peak), 2–4) three time-to-exhaustion tests at 80, 100 and 105% MAP to calculate CP and W?, 5–7) four 3-minute all-out tests to calculate end power (EP) and work done above EP (WEP) using cadences ranging from preferred ?5 to preferred +10 rev·min?1 to set the fixed resistance. Significant differences were seen between CP and EP-preferred (267.5 ± 22.6 W vs. 296.6 ± 26.1 W, < 0.001), CP and EP?5 (267.5 ± 22.6 W vs. 303.6 ± 24.0 W, < 0.001) and between CP and EP+5 (267.5 ± 22.6 W vs. 290.0 ± 28.0 W, = 0.002). No significant differences were seen between CP and EP+10 (267.5 ± 22.6 W vs. 278.1 ± 30.9 W, = 0.331). Significant differences were seen between W? and WEP at all tested fixed resistances. EP is reduced when cycling at higher than preferred cadences, providing better estimates of CP.  相似文献   

7.
Abstract

The purpose of this study was to assess the power output of field-based downhill mountain biking. Seventeen trained male downhill cyclists (age 27.1 ± 5.1 years) competing nationally performed two timed runs of a measured downhill course. An SRM powermeter was used to simultaneously record power, cadence, and speed. Values were sampled at 1-s intervals. Heart rates were recorded at 5-s intervals using a Polar S710 heart rate monitor. Peak and mean power output were 834 ± 129 W and 75 ± 26 W respectively. Mean power accounted for only 9% of peak values. Paradoxically, mean heart rate was 168 ± 9 beats · min?1 (89% of age-predicted maximum heart rate). Mean cadence (27 ± 5 rev · min?1) was significantly related to speed (r = 0.51; P < 0.01). Analysis revealed an average of 38 pedal actions per run, with average pedalling periods of 5 s. Power and cadence were not significantly related to run time or any other variable. Our results support the intermittent nature of downhill mountain biking. The poor relationships between power and run time and between cadence and run time suggest they are not essential pre-requisites to downhill mountain biking performance and indicate the importance of riding dynamics to overall performance.  相似文献   

8.
The pre-event warm-up or “priming” routine for optimising cycling performance is not well-defined or uniform to a specific event. We aimed to determine the effects of varying the intensity of priming on 3 km cycling performance. Ten endurance-trained male cyclists completed four 3 km time-trials (TT) on four separate occasions, each preceded by a different priming strategy including “self-selected” priming and three intermittent priming strategies incorporating 10 min of constant-load cycling followed by 5 × 10 s bouts of varying relative intensity (100% and 150% of peak aerobic power, Wpeak, and all-out priming). The self-selected priming trial (379 ± 44 W) resulted in similar mean power during the 3 km TT to intermittent priming at 100% (376 ± 45 W; ?0.7%; unclear) and 150% (374 ± 48 W; ?1.5%, unclear) of Wpeak, but significantly greater than all-out priming (357 ± 45 W; ?5.8%, almost certainly harmful). Differences between intermittent and self-selected priming existed with regards to heart rate (6.2% to 11.5%), blood lactate (?22.9% to 125%) and VO2 kinetics (?22.9% to 8.2%), but these were not related to performance outcomes. In conclusion, prescribed intermittent priming strategies varying in intensity did not substantially improve 3 km TT performance compared to self-selected priming.  相似文献   

9.
Abstract

It has been shown that the critical power (CP) in cycling estimated using a novel 3-min all-out protocol is reliable and closely matches the CP derived from conventional procedures. The purpose of this study was to assess the predictive validity of the all-out test CP estimate. We hypothesised that the all-out test CP would be significantly correlated with 16.1-km road time-trial (TT) performance and more strongly correlated with performance than the gas exchange threshold (GET), respiratory compensation point (RCP) and V?O2 max. Ten club-level male cyclists (mean±SD: age 33.8±8.2 y, body mass 73.8±4.3 kg, V?O2 max 60±4 ml·kg?1·min?1) performed a 10-mile road TT, a ramp incremental test to exhaustion, and two 3-min all-out tests, the first of which served as familiarisation. The 16.1-km TT performance (27.1±1.2 min) was significantly correlated with the CP (309±34 W; r=?0.83, P<0.01) and total work done during the all-out test (70.9±6.5 kJ; r=?0.86, P<0.01), the ramp incremental test peak power (433±30 W; r=?0.75, P<0.05) and the RCP (315±29 W; r=?0.68, P<0.05), but not with GET (151±32 W; r=?0.21) or the V?O2 max (4.41±0.25 L·min?1; r=?0.60). These data provide evidence for the predictive validity and practical performance relevance of the 3-min all-out test. The 3-min all-out test CP may represent a useful addition to the battery of tests employed by applied sport physiologists or coaches to track fitness and predict performance in atheletes.  相似文献   

10.
Abstract

There is little published data in relation to the effects of caffeine upon cycling performance, speed and power in trained cyclists, especially during cycling of ~60 s duration. To address this, eight trained cyclists performed a 1 km time-trial on an electronically braked cycle ergometer under three conditions: after ingestion of 5 mg · kg?1 caffeine, after ingestion of a placebo, or a control condition. The three time-trials were performed in a randomized order and performance time, mean speed, mean power and peak power were determined. Caffeine ingestion resulted in improved performance time (caffeine vs. placebo vs. control: 71.1 ± 2.0 vs. 73.4 ± 2.3 vs. 73.3 ± 2.7 s; P = 0.02; mean ± s). This change represented a 3.1% (95% confidence interval: 0.7–5.6) improvement compared with the placebo condition. Mean speed was also higher in the caffeine than placebo and control conditions (caffeine vs. placebo vs. control: 50.7 ± 1.4 vs. 49.1 ± 1.5 vs. 49.2 ± 1.7 km · h?1; P = 0.0005). Mean power increased after caffeine ingestion (caffeine vs. placebo vs. control: 523 ± 43 vs. 505 ± 46 vs. 504 ± 38 W; P = 0.007). Peak power also increased from 864 ± 107 W (placebo) and 830 ± 87 W (control) to 940 ± 83 W after caffeine ingestion (P = 0.027). These results provide support for previous research that found improved performance after caffeine ingestion during short-duration high-intensity exercise. The magnitude of the improvements observed in our study could be due to our use of sport-specific ergometry, a tablet form and trained participants.  相似文献   

11.
Abstract

The aim of this study was to compare optimization and correction procedures for the determination of peak power output during friction-loaded cycle ergometry. Ten male and 10 female sports students each performed five 10-s sprints from a stationary start on a Monark 864 basket-loaded ergometer. Resistive loads of 5.0, 6.5, 8.0, 9.5, and 11.0% body weight were administered in a counterbalanced order, with a recovery period of 10 min between sprints. Peak power was greater and occurred earlier, with less work having been done before the attainment of peak power, when the data were corrected to account for the inertial and frictional characteristics of the ergometer. Corrected peak power was independent of resistive load (P > 0.05), whereas uncorrected peak power varied as a quadratic function of load (P < 0.001). For males and females, optimized peak power (971 ± 122 and 668 ± 37 W) was lower (P < 0.01) than either the highest (1074 ± 111 and 754 ± 56 W respectively) or the mean (1007 ± 125 and 701 ± 45 W respectively) of the five values for corrected peak power. Optimized and mean corrected peak power were highly correlated both in males (r = 0.97, P < 0.001) and females (r = 0.96, P < 0.001). The difference between optimized and mean corrected peak power was 37 ± 30 W in males and 33 ± 14 W in females, of which approximately 15 W was due to the correction for frictional losses. We conclude that corrected peak power is independent of resistive load in males and females.  相似文献   

12.
ABSTRACT

This study aimed to assess the relationship between an uphill time-trial (TT) performance and both aerobic and anaerobic parameters obtained from laboratory tests. Fifteen cyclists performed a Wingate anaerobic test, a graded exercise test (GXT) and a field-based 20-min TT with 2.7% mean gradient. After a 5-week non-supervised training period, 10 of them performed a second TT for analysis of pacing reproducibility. Stepwise multiple regressions demonstrated that 91% of TT mean power output variation (W kg?1) could be explained by peak oxygen uptake (ml kg?1.min?1) and the respiratory compensation point (W kg?1), with standardised beta coefficients of 0.64 and 0.39, respectively. The agreement between mean power output and power at respiratory compensation point showed a bias ± random error of 16.2 ± 51.8 W or 5.7 ± 19.7%. One-way repeated-measures analysis of variance revealed a significant effect of the time interval (123.1 ± 8.7; 97.8 ± 1.2 and 94.0 ± 7.2% of mean power output, for epochs 0–2, 2–18 and 18–20 min, respectively; P < 0.001), characterising a positive pacing profile. This study indicates that an uphill, 20-min TT-type performance is correlated to aerobic physiological GXT variables and that cyclists adopt reproducible pacing strategies when they are tested 5 weeks apart (coefficients of variation of 6.3; 1 and 4%, for 0–2, 2–18 and 18–20 min, respectively).  相似文献   

13.
Abstract

The aim of the study was to assess the relationship between performance-based and laboratory tests for muscular strength and power assessment in older women. Thirty-two women aged 68.8 ± 2.8 years were recruited. All participants were asessed for: (a) two performance-based tests – the box-stepping test (mean 296 ± 51 J) and two-revolution maximum test (mean 7.1 ± 2 kg) performed while pedalling on a cycle ergometer; and (b) muscular function tests – maximal instantaneous peak power jumping on a force platform (mean 1528 ± 279 W); maximal voluntary contraction (MVC) during knee extension (mean 601 ± 571 N) and leg press (mean 626 ± 126 N), and leg press power (mean 483 ± 98 W) on a dynamometer. Using univariate analysis, performance-based tests were compared with laboratory muscle strength and power measurements. Muscle power correlated most strongly with the performance-based tests for both jumping and leg press power (r-values between 0.67 and 0.75; P < 0.01). The correlation with muscle strength measures ranged between 0.48 and 0.61 (P < 0.01). The proposed tests may have particular relevance in geriatric and rehabilitation environments as they represent an easy, practical, and inexpensive alternative for the assessment of muscular strength and power.  相似文献   

14.
15.
Purpose: Critical power (CP) from the 3-min test was compared to the power outputs associated with thresholds determined from gas exchange parameters that have been used to demarcate the exercise-intensity domains including the respiratory compensation point (RCP), gas exchange threshold (GET), and ventilatory threshold (VT). Method: Twenty-eight participants performed an incremental-cycle ergometer test to exhaustion. The VT was determined from the relationship between the ventilatory equivalent for oxygen uptake (V˙E/V˙O2) versus V˙O2 and the GET was determined using the V-slope method (V˙CO2 vs. V˙O2). The RCP was identified from the V˙E-versus-V˙CO2 relationship. CP was the average power output during the last 30 s of the 3-min all-out test. Linear regression was used to determine the power outputs associated with the RCP, GET, and VT, as well as the V˙O2 associated with CP. Mean differences among the associated power outputs, percent V˙O2 peak, and percent peak power output for the GET, VT, RCP, and CP were analyzed using separate one-way repeated-measures analyses of variance. Results: There were no significant differences between CP (187 ± 47 W) and the power output associated with RCP (190 ± 49 W) or between the power outputs associated with GET (139 ± 37 W) and VT (145 ± 37 W). The power outputs associated with GET and VT, however, were significantly less than were those at CP and associated with RCP. Conclusions: These findings suggest CP and RCP demarcate the heavy from severe exercise-intensity domain and result from a different mechanism of fatigue than that of GET and VT, possibly hyperkalemia.  相似文献   

16.
Abstract

Mechanical models of cycling time-trial performance have indicated adverse effects of variations in external power output on overall performance times. Nevertheless, the precise influences of the magnitude and number of these variations over different distances of time trial are unclear. A hypothetical cyclist (body mass 70 kg, bicycle mass 10 kg) was studied using a mathematical model of cycling, which included the effects of acceleration. Performance times were modelled over distances of 4–40 km, mean power outputs of 200–600 W, power variation amplitudes of 5–15% and variation frequencies of 2–32 per time-trial. Effects of a “fast-start” strategy were compared with those of a constant-power strategy. Varying power improved 4-km performance at all power outputs, with the greatest improvement being 0.90 s for ± 15% power variation. For distances of 16.1, 20 and 40 km, varying power by ± 15% increased times by 3.29, 4.46 and 10.43 s respectively, suggesting that in long-duration cycling in constant environmental conditions, cyclists should strive to reduce power variation to maximise performance. The novel finding of the present study is that these effects are augmented with increasing event distance, amplitude and period of variation. These two latter factors reflect a poor adherence to a constant speed.  相似文献   

17.
Abstract

Power output and heart rate were monitored for 11 months in one female ([Vdot]O2max: 71.5 mL · kg?1 · min?1) and ten male ([Vdot]O2max: 66.5 ± 7.1 mL · kg?1 · min?1) cyclists using SRM power-meters to quantify power output and heart rate distributions in an attempt to assess exercise intensity and to relate training variables to performance. In total, 1802 data sets were divided into workout categories according to training goals, and power output and heart rate intensity zones were calculated. The ratio of mean power output to respiratory compensation point power output was calculated as an intensity factor for each training session and for each interval during the training sessions. Variability of power output was calculated as a coefficient of variation. There was no difference in the distribution of power output and heart rate for the total season (P = 0.15). Significant differences were observed during high-intensity workouts (P < 0.001). Performance improvements across the season were related to low-cadence strength workouts (P < 0.05). The intensity factor for intervals was related to performance (P < 0.01). The variability in power output was inversely associated with performance (P < 0.01). Better performance by cyclists was characterized by lower variability in power output and higher exercise intensities during intervals.  相似文献   

18.
ABSTRACT

The main purpose of this study was to assess the acute effects of small changes in crank length (assumable by competitive cyclists) on metabolic cost and pedalling technique during submaximal cycling. Twelve amateur road cyclists performed three sets of submaximal pedalling (150, 200 and 250 W) at a constant cadence (91.3 ± 0.8 rpm) in a randomised order with three commonly used crank lengths, preferred (172.5–175 mm), +5 mm and ?5 mm. Energy cost of pedalling, kinetic and kinematic variables were simultaneously registered. Changes in crank length had no significant effect on heart rate (144 ± 13, 145 ± 12 and 145 ± 13 bpm, respectively) and gross efficiency (GE) (20.4 ± 2.1, 20.1 ± 2.2 and 20.3 ± 2.4%, respectively). A longer crank induced a significant (P < 0.05) reduction of positive impulse proportion (PIP) (0.9–1.9%) due to a greater maximum (1.0–2.3 N · m) and minimum torque (1.0–2.2 N · m). At the same time, the maximum flexion and range of motion of the hip and knee joints were significantly increased (1.8–3.4° and P < 0.05), whereas the ankle joint was not affected. In conclusion, the biomechanical changes due to a longer crank did not alter the metabolic cost of pedalling, although they could have long-term adverse effects. Therefore, in case of doubt between two lengths, the shorter one might be recommended.  相似文献   

19.
ABSTRACT

The aims of this study were to analyse the optimal cadence for peak power production and time to peak power in bicycle motocross (BMX) riders. Six male elite BMX riders volunteered for the study. Each rider completed 3 maximal sprints at a cadence of 80, 100, 120 and 140 revs · min?1 on a laboratory Schoberer Rad Messtechnik (SRM) cycle ergometer in isokinetic mode. The riders’ mean values for peak power and time of power production in all 3 tests were recorded. The BMX riders produced peak power (1105 ± 139 W) at 100 revs · min?1 with lower peak power produced at 80 revs · min?1 (1060 ± 69 W, (F(2,15) = 3.162; P = .266; η2 = 0.960), 120 revs · min?1 (1077 ± 141 W, (F(2,15) = 4.348; P = .203; η2 = 0.970) and 140 revs · min?1 (1046 ± 175 W, (F(2,15) = 12.350; P = 0.077; η2 = 0.989). The shortest time to power production was attained at 120 revs · min?1 in 2.5 ± 1.07 s. Whilst a cadence of 80 revs · min?1 (3.5 ± 0.8 s, (F(2,15) = 2.667; P = .284; η2 = 0.800) 100 revs · min?1 (3.00 ± 1.13 s, (F(2,15) = 24.832; P = .039; η2 = 0.974) and 140 revs · min?1 (3.50 ± 0.88 s, (F(2,15) = 44.167; P = .006; η2 = 0.967)) all recorded a longer time to peak power production. The results indicate that the optimal cadence for producing peak power output and reducing the time to peak power output are attained at comparatively low cadences for sprint cycling events. These findings could potentially inform strength and conditioning training to maximise dynamic force production and enable coaches to select optimal gear ratios.  相似文献   

20.
ABSTRACT

The effectiveness of 8-week force-velocity optimised training was assessed in highly trained professional rugby league athletes. Players (age 24 ± 3 years; body mass 94.9 ± 21.6 kg; height 181.3 ± 6.0 cm) were strength-matched and assigned to a force-velocity optimised group (OP; n = 15) or a general strength-power group (GP; n = 14). Tests included 10-m, 20-m sprints, 3 repetition-maximum squat and squat jumps over five load conditions to ascertain vertical force-velocity relationship. ANCOVA revealed there was a group effect for force-velocity deficit (P < 0.001), with the OP two-fold greater than the GP group (OP pre: 51.13 ± 31.42%, post: 62.26 ± 31.45%, GP pre: 33.00 ± 19.60%, post: 31.14 ± 31.45%, P < 0.001). There were further group effects for 3RM squat (OP pre: 151.17 ± 22.95 kg, post: 162.17 ± 24.16 kg, GP pre: 156.43 ± 25.07 kg, post: 163.39 ± 25.39 kg, P < 0.001), peak power (OP pre: 3195 ± 949 W, post: 3552 ± 1033 W, GP pre: 3468 ± 911 W, post: 3591 ± 936 W, P < 0.001), and SJ (OP pre: 39.79 ± 7.80 cm, post: 42.69 ± 7.83 cm, GP pre: 40.44 ± 6.23 cm, post: 41.14 ± 5.66 cm, P < 0.001). Prescribing F-V deficit training is superior for improving physical performance within highly trained RL players.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号