首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
This study investigated the effect cadence has on the estimation of critical power (CP) and the finite work capacity (W?) during the 3-minute all-out cycling test. Ten participants completed 8 tests: 1) an incremental test to calculate gas exchange threshold (GET), maximal aerobic power (MAP) and peak oxygen uptake (V?O2peak), 2–4) three time-to-exhaustion tests at 80, 100 and 105% MAP to calculate CP and W?, 5–7) four 3-minute all-out tests to calculate end power (EP) and work done above EP (WEP) using cadences ranging from preferred ?5 to preferred +10 rev·min?1 to set the fixed resistance. Significant differences were seen between CP and EP-preferred (267.5 ± 22.6 W vs. 296.6 ± 26.1 W, < 0.001), CP and EP?5 (267.5 ± 22.6 W vs. 303.6 ± 24.0 W, < 0.001) and between CP and EP+5 (267.5 ± 22.6 W vs. 290.0 ± 28.0 W, = 0.002). No significant differences were seen between CP and EP+10 (267.5 ± 22.6 W vs. 278.1 ± 30.9 W, = 0.331). Significant differences were seen between W? and WEP at all tested fixed resistances. EP is reduced when cycling at higher than preferred cadences, providing better estimates of CP.  相似文献   

2.
The purpose of this study was to investigate the use of a single 3-min all-out maximal effort to estimate anaerobic capacity (AC) through the lactate and excess post-exercise oxygen consumption (EPOC) response methods (AC[La?]+EPOCfast) on a cycle ergometer. Eleven physically active men (age?=?28.1?±?4.0?yrs, height?=?175.1?±?4.2?cm, body mass?=?74.8?±?11.9?kg and ?O2max?=?40.7?±?7.3?mL?kg?1?min?1), participated in the study and performed: i) five submaximal efforts, ii) a supramaximal effort at 115% of intensity of ?O2max, and iii) a 3-min all-out maximal effort. Anaerobic capacity was estimated using the supramaximal effort through conventional maximal accumulated oxygen deficit (MAOD) and also through the sum of oxygen equivalents from the glycolytic (fast component of excess post-exercise oxygen consumption) and phosphagen pathways (blood lactate accumulation) (AC[La?]+EPOCfast), while during the 3-min all-out maximal effort the anaerobic capacity was estimated using the AC[La?]+EPOCfast procedure. There were no significant differences between the three methods (p?>?0.05). Additionally, the anaerobic capacity estimated during the 3-min all-out effort was significantly correlated with the MAOD (r?=?0.74; p?=?0.009) and AC[La?]+EPOCfast methods (r?=?0.65; p?=?0.029). Therefore, it is possible to conclude that the 3-min all-out effort is valid to estimate anaerobic capacity in physically active men during a single cycle ergometer effort.  相似文献   

3.
Purpose: Critical power (CP) from the 3-min test was compared to the power outputs associated with thresholds determined from gas exchange parameters that have been used to demarcate the exercise-intensity domains including the respiratory compensation point (RCP), gas exchange threshold (GET), and ventilatory threshold (VT). Method: Twenty-eight participants performed an incremental-cycle ergometer test to exhaustion. The VT was determined from the relationship between the ventilatory equivalent for oxygen uptake (V˙E/V˙O2) versus V˙O2 and the GET was determined using the V-slope method (V˙CO2 vs. V˙O2). The RCP was identified from the V˙E-versus-V˙CO2 relationship. CP was the average power output during the last 30 s of the 3-min all-out test. Linear regression was used to determine the power outputs associated with the RCP, GET, and VT, as well as the V˙O2 associated with CP. Mean differences among the associated power outputs, percent V˙O2 peak, and percent peak power output for the GET, VT, RCP, and CP were analyzed using separate one-way repeated-measures analyses of variance. Results: There were no significant differences between CP (187 ± 47 W) and the power output associated with RCP (190 ± 49 W) or between the power outputs associated with GET (139 ± 37 W) and VT (145 ± 37 W). The power outputs associated with GET and VT, however, were significantly less than were those at CP and associated with RCP. Conclusions: These findings suggest CP and RCP demarcate the heavy from severe exercise-intensity domain and result from a different mechanism of fatigue than that of GET and VT, possibly hyperkalemia.  相似文献   

4.
The aim of this study was to determine the effects of caffeine ingestion on a ‘preloaded’ protocol that involved cycling for 2?min at a constant rate of 100% maximal power output immediately followed by a 1-min ‘all-out’ effort. Eleven male cyclists completed a ramp test to measure maximal power output. On two other occasions, the participants ingested caffeine (5?mg?·?kg?1) or placebo in a randomized, double-blind procedure. All tests were conducted on the participants' own bicycles using a Kingcycle? test rig. Ratings of perceived exertion (RPE; 6–20 Borg scale) were lower in the caffeine trial by approximately 1 RPE point at 30, 60 and 120?s during the constant rate phase of the preloaded test (P?<0.05). The mean power output during the all-out effort was increased following caffeine ingestion compared with placebo (794±164 vs 750±163?W; P?=?0.05). Blood lactate concentration 4, 5 and 6?min after exercise was also significantly higher by approximately 1?mmol?·?l?1 in the caffeine trial (P?<0.05). These results suggest that high-intensity cycling performance can be increased following moderate caffeine ingestion and that this improvement may be related to a reduction in RPE and an elevation in blood lactate concentration.  相似文献   

5.
ABSTRACT

This study aimed to assess the relationship between an uphill time-trial (TT) performance and both aerobic and anaerobic parameters obtained from laboratory tests. Fifteen cyclists performed a Wingate anaerobic test, a graded exercise test (GXT) and a field-based 20-min TT with 2.7% mean gradient. After a 5-week non-supervised training period, 10 of them performed a second TT for analysis of pacing reproducibility. Stepwise multiple regressions demonstrated that 91% of TT mean power output variation (W kg?1) could be explained by peak oxygen uptake (ml kg?1.min?1) and the respiratory compensation point (W kg?1), with standardised beta coefficients of 0.64 and 0.39, respectively. The agreement between mean power output and power at respiratory compensation point showed a bias ± random error of 16.2 ± 51.8 W or 5.7 ± 19.7%. One-way repeated-measures analysis of variance revealed a significant effect of the time interval (123.1 ± 8.7; 97.8 ± 1.2 and 94.0 ± 7.2% of mean power output, for epochs 0–2, 2–18 and 18–20 min, respectively; P < 0.001), characterising a positive pacing profile. This study indicates that an uphill, 20-min TT-type performance is correlated to aerobic physiological GXT variables and that cyclists adopt reproducible pacing strategies when they are tested 5 weeks apart (coefficients of variation of 6.3; 1 and 4%, for 0–2, 2–18 and 18–20 min, respectively).  相似文献   

6.
7.
Purpose: To determine the accuracy of critical power (CP) and W? (the curvature constant of the power-duration relationship) derived from self-paced time-trial (TT) prediction trials using mobile power meters to predict 16.1-km road cycling TT performance. This study also aimed to assess the agreement between functional threshold power (FTP) and CP.

Methods: Twelve competitive male cyclists completed an incremental test to exhaustion, a FTP test and 4–5 self-paced TT bouts on a stationary bike within the lab, and a 16.1 km road TT, using mobile power meters.

Results: CP and W? derived from the power-duration relationship closely predicted TT performance. The 16.1-km road TT completion time (26.7 ± 2.2 min) was not significantly different from and was significantly correlated with the predicted time-to-completion (27.5 ± 3.3 min, = 0.89, < 0.01). CP and FTP were not significantly different (275 ± 40 W vs. 278 ± 42 W, > 0.05); however, the limits of agreement between CP and FTP were 30 to -36 W.

Discussion: The findings of this study indicate that CP and W? determined using mobile power meters during maximal, self-paced TT prediction trials can be used to accurately predict 16.1-km cycling performance, supporting the application of the CP and W? for performance prediction. However, the limits of agreement were too large to consider FTP and CP interchangeable.  相似文献   


8.
9.
The minimum exercise intensity that elicits ?O2max (i?O2max) is an important variable associated with endurance exercise performance. i?O2max is usually determined during a maximal incremental exercise test; however, the magnitude and duration of the increments used influence the i?O2max value produced by a given test. The aims of this study were twofold. The first was to investigate whether the i?O2max value produced by a single cycle ergometer test (i?O2max(S)) was repeatable. The second was to determine if i?O2max(S) represents the minimum intensity at which ?O2max is elicited when compared to a refined i?O2max value (i?O2max(R)) derived from repeated tests. Seventeen male cyclists (age 33.9?±?7.7 years, body mass 80.9?±?10.2?kg, height 1.82?±?0.05?m; VO2max 4.27?±?0.62 L?min?1) performed four maximal incremental tests for the determination of i?O2max(S) and i?O2max(R) (3 min stages; 20?W increments). Trials 1 and 2 were identical and used for assessing the repeatability of i?O2max(S), trials 3 and 4 began at different intensities and were used to determine i?O2max(R). i?O2max(S) showed good test–retest repeatability for i?O2max (CV?=?4.1%; ICC?=?0.93), VO2max (CV?=?6.3%; ICC?=?0.88) and test duration (CV?=?6.7%; ICC?=?0.89). There was no significant difference between i?O2max(S) and i?O2max(R) (303?±?40?W vs. 301?±?42?W) (P?2max determined directly during a maximal incremental test is repeatable and provides a very good estimate of the minimum exercise intensity that elicits ?O2max.  相似文献   

10.
The pre-event warm-up or “priming” routine for optimising cycling performance is not well-defined or uniform to a specific event. We aimed to determine the effects of varying the intensity of priming on 3 km cycling performance. Ten endurance-trained male cyclists completed four 3 km time-trials (TT) on four separate occasions, each preceded by a different priming strategy including “self-selected” priming and three intermittent priming strategies incorporating 10 min of constant-load cycling followed by 5 × 10 s bouts of varying relative intensity (100% and 150% of peak aerobic power, Wpeak, and all-out priming). The self-selected priming trial (379 ± 44 W) resulted in similar mean power during the 3 km TT to intermittent priming at 100% (376 ± 45 W; ?0.7%; unclear) and 150% (374 ± 48 W; ?1.5%, unclear) of Wpeak, but significantly greater than all-out priming (357 ± 45 W; ?5.8%, almost certainly harmful). Differences between intermittent and self-selected priming existed with regards to heart rate (6.2% to 11.5%), blood lactate (?22.9% to 125%) and VO2 kinetics (?22.9% to 8.2%), but these were not related to performance outcomes. In conclusion, prescribed intermittent priming strategies varying in intensity did not substantially improve 3 km TT performance compared to self-selected priming.  相似文献   

11.
ABSTRACT

Introduction: High-Intensity Interval Training (HIIT) and Constant-Intensity Endurance Training (CIET) improves peak oxygen uptake (V?O2) similarly in adults; but in children this remains unclear, as does the influence of maturity. Methods: Thirty-seven boys formed three groups: HIIT (football; n = 14; 14.3 ± 3.1 years), CIET (distance runners; n = 12; 13.1 ± 2.5 years) and a control (CON) group (n = 11; 13.7 ± 3.2 years). Peak V?O2 and gas exchange threshold (GET) were determined from a ramp test and anaerobic performance using a 30 m sprint pre-and-post a three-month training cycle. Results: The HIIT groups peak V?O2 was significantly higher than the CON group pre (peak V?O2: 2.54 ± 0.63 l·min-1 vs 2.03 ± 0.53 l·min-1, d = 0.88; GET: 1.41 ± 0.26 l·min-1 vs 1.13 ± 0.29 l·min-1, d = 1.02) and post-training (peak V?O2: 2.63 ± 0.73 l·min-1 vs 2.08 ± 0.64 l·min-1, d = 0.80; GET: 1.32 ± 0.33 l·min-1 vs 1.15 ± 0.38 l·min-1, d = 0.48). All groups showed a similar magnitude of change during the training (p > 0.05). Conclusion: HIIT was not superior to CIET for improving aerobic or anaerobic parameters in adolescents. Secondly, pre- and post-pubertal participants demonstrated similar trainability.  相似文献   

12.
The aim of the present study was to examine the effect of ingesting 75?g of glucose 45?min before the start of a graded exercise test to exhaustion on the determination of the intensity that elicits maximal fat oxidation (Fatmax). Eleven moderately trained individuals ( V?O2max: 58.9±1.0?ml?·?kg?1?·?min?1; mean±s ), who had fasted overnight, performed two graded exercise tests to exhaustion, one 45?min after ingesting a placebo drink and one 45?min after ingesting 75?g of carbohydrate in the form of glucose. The tests started at 95?W and the workload was increased by 35?W every 3?min. Gas exchange measures and heart rate were recorded throughout exercise. Fat oxidation rates were calculated using stoichiometric equations. Blood samples were collected at rest and at the end of each stage of the test. Maximal fat oxidation rates decreased from 0.46±0.06 to 0.33±0.06?g?·?min?1 when carbohydrate was ingested before the start of exercise (P?<0.01). There was also a decrease in the intensity which elicited maximal fat oxidation (60.1±1.9% vs 52.0±3.4% V?O2max) after carbohydrate ingestion (P?<0.05). Maximal power output was higher in the carbohydrate than in the placebo trial (346±12 vs 332±12?W) (P?<0.05). In conclusion, the ingestion of 75?g of carbohydrate 45?min before the onset of exercise decreased Fatmax by 14%, while the maximal rate of fat oxidation decreased by 28%.  相似文献   

13.
The purpose of the study was to investigate which physiological parameters would most accurately predict a 6-min, all-out, double-poling (DP) performance in recreational cross-country skiers. Twelve male recreational cross-country skiers performed tests consisting of three series lasting 10 s, one lasting 60 s, plus a 6-min, all-out, DP performance test to estimate mean and peak power output. On a separate day, gross mechanical efficiency (GE) was estimated from a 10-min, submaximal, DP test and maximal oxygen consumption (VO2 max) was estimated from an incremental treadmill running test. Power was measured after each stroke from the acceleration and deceleration of the flywheel that induced the friction on the ergometer. The power was shown to the skier on a small computer placed on the ergometer. A multivariable correlation analysis showed that GE most strongly predicted 6-min DP performance (r = 0.79) and interestingly, neither DP VO2 max, nor treadmill-running VO2 max, correlated with 6-min DP performance. In conclusion, GE correlated most strongly with 6-min DP performance and GE at the ski ergometer was estimated to be 6.4 ± 1.1%. It is suggested that recreational cross-country skiers focus on skiing technique to improve gross mechanical efficiency during intense DP.  相似文献   

14.
Critical power is a theoretical concept that presumes there is a certain work‐rate which may be maintained without exhaustion. The extent to which critical power predicts running performance over varying distances has not been determined, and so the aim of this study was to correlate measurements of critical power in the laboratory to running performances in the field at 40 m and 1, 10 and 21.1 km in a group of 17 male longdistance runners (mean ± s.d. age = 31.7 ± 7.3 years). Each subject ran to exhaustion on the treadmill in the laboratory at six different speeds, ranging from 17 to 25 km h‐1. Least squares analyses were used to fit an exponential decay to the relationship between the running speed (y) versus time to exhaustion (x). Critical power was calculated as the running speed (y) coinciding with the asymptote or C parameter of the y = A‐e(‐Bx) + C relationship. The VO2 max was also measured in all subjects. For the data in the field, each subject was timed over 40 m and 1 km and participated in 10‐ and 21.1‐km races. The mean critical power of die subjects in this study was 18.5 ± 1.6 km h‐1. The test‐retest correlation coefficient for the determination of critical power was r = 0.99. The mean VO2 max, measured in a progressive exercise protocol starting at 13 km h‐1 and increasing by 1 km h‐1 every minute, was 59.2 ± 4.6 ml O2 kg‐1 min‐1. The 40‐m times ranged from 5.57 to 6.95 s, the 1‐km times from 2:46 to 3:55 min:s, the 10‐km times from 30:43 to 42:02 min:s and the 21‐km times from 67:00 to 95:45 min:s. Critical power predicted running times over 1 km (r = ‐0.75, P< 0.001), 10 km (r = ‐ 0.85, P< 0.00001) and 21.1 km (r = ‐ 0.79, P< 0.001) in this heterogeneous group of runners. The correlation coefficients for VO2 max and running performances were similar to the above at all distances. Even in the best relationship between critical power and the time taken to run 10 km, only 72% of the variation in the 10‐km running time could be accounted for by differences in critical power. While the test of critical power may be repeatable and correlate significantly with VO2 max (r = 0.77, P< 0.001), the measurement lacks the degree of specificity required to predict running performance in trained subjects of varying ability.  相似文献   

15.
Abstract

The aims of the study were to investigate blood lactate recovery and respiratory variables during diagonal skiing of variable intensity in skiers at different performance levels. Twelve male cross-country skiers classified as elite (n=6; [Vdot]O2max=73±3 ml · kg?1 · min?1) or moderately trained (n=6; [Vdot]O2max=61±5 ml · kg?1 · min?1) performed a 48-min variable intensity protocol on a treadmill using the diagonal stride technique on roller skis, alternating between 3 min at 90% and 6 min at 70% of [Vdot]O2max. None of the moderately trained skiers were able to complete the variable intensity protocol and there was a difference in time to exhaustion between the two groups (elite: 45.0±7.3 min; moderately trained: 31.4±10.4 min) (P<0.05). The elite skiers had lower blood lactate concentrations and higher blood base excess concentrations at all 70% workloads than the moderately trained skiers (all P<0.05). In contrast, [Vdot] E/[Vdot]O2 and [Vdot] E/[Vdot]CO2 at the 70% [Vdot]O2max workloads decreased independently of group (P<0.05). Partial correlations showed that [Vdot]O2max was related to blood lactate at the first and second intervals at 70% of [Vdot]O2max (r=?0.81 and r=?0.82; both P<0.01) but not to [Vdot] E/[Vdot]O2, [Vdot] E/[Vdot]CO2 or the respiratory exchange ratio. Our results demonstrate that during diagonal skiing of variable intensity, (1) elite skiers have superior blood lactate recovery compared with moderately trained skiers, who did not show any lactate recovery at 70% of [Vdot]O2max, suggesting it is an important characteristic for performance; and (2) the decreases in respiratory exchange ratio, [Vdot] E/[Vdot]O2, and [Vdot] E/[Vdot]CO2 do not differ between elite and moderately trained skiers.  相似文献   

16.
To adhere to the principle of “exercise specificity” exercise testing should be completed using the same physical activity that is performed during exercise training. The present study was designed to assess whether aerobic step exercisers have a greater maximal oxygen consumption (max VO2) when tested using an activity specific, maximal step exercise test (SET; arms and legs) versus a maximal running test (legs only). Female aerobic step exercisers (N=18; 20.7 ± 1.5 years) performed three maximal graded exercise tests (GXTs): 2 SETs; 1 treadmill test (TMT). The SET consisted of six 3-min progressive stages of alternate lead, basic step, basic step with biceps curls, knee raise with pull-down, repeater knee with pull-down, lateral lunge with pull-down, and side squat with shoulder presses. Stepping rate was 32 steps· min?1 on an 8-in (20.32 cm) step for stages 1–3, and a 10-in (25.4 cm) step for stages 4–6. Submaximal and maximal heart rate (HR) and oxygen consumption (VO2) were recorded at the end of each stage. Test–retest reliability for the first five stages of the SET ranged from .91 to .97 for HR, and from .84 to .96 for VO2. Maximal HR was significantly greater (p =.0001) for the SET (200 ± 6.2 beats·min?1) as compared to the TMT (193 ± 7.9 beats·min?1). No significant difference was found for max VO2 (42.9 ± 8.5, 41.2 ± 5.9 ml·kg?1·min?1, p =.14). The SET was a valid and reliable protocol for assessing responses of these aerobic step exercisers; however, max VO2 from a TMT did not differ significantly from the SET. Conversely, max HR obtained from the criterion TMT was 7 beats·min?1 lower than from the SET. If a training HR for step exercise (arms and legs exercise) is prescribed based on the max HR from treadmill exercise (legs only), then the training HR should be calculated from a TMT max HR that has been increased by 7 beats·min?1 to obtain an intensity of step exercise comparable to that of running.  相似文献   

17.
Nine well-trained, unacclimatized female hockey players performed the Loughborough Intermittent Shuttle Test (LIST) interspersed with three field hockey skill tests in hot (30°C, 38% relative humidity) and moderate (19°C, 51% relative humidity) environmental conditions. Field hockey skill performance declined in both the hot and moderate conditions following 30 and 60?min of the LIST compared with pre-LIST values (P <?0.01). This decrement in performance was compounded in the hot environment with a 6% poorer performance in the heat recorded for the second skill test at 30?min (P <?0.05, hot 101.7?±?3.6 vs moderate 95.7?±?2.9?s; mean ±?s x). However, no difference was found in the decision-making element of the skill test. Fifteen-metre sprint times were slower in the hot condition (P <?0.01). In the hot environment, rectal temperature (P?<?0.01), perceived exertion (P?<?0.05), perceived thirst (P?<?0.01), blood glucose concentration (P?<?0.05) and serum aldosterone concentration (P?<?0.01) were higher. Estimated mean (?±?s x) sweat rate was higher in the hot trial (1.27?±?0.10?l?·?h?1) than in the moderate trial (1.05?±?0.12?l?·?h?1) (P?<?0.05). Body mass was well maintained in both trials. No differences in serum cortisol, blood lactate, plasma volume or plasma ammonia concentrations were found. These results demonstrate that field hockey skill performance is decreased following intermittent high-intensity shuttle running and that this decrease is greater in hot environmental conditions. The exact mechanism for this decrement in performance remains to be elucidated, but is unlikely to be due to low glycogen concentration or dehydration.  相似文献   

18.
ABSTRACT

The purpose of this study was to explore the respiratory response of acute interval and continuous exercise (CE) of low and high intensity. Fourteen recreational athletes (7 men and 7 women; VO2max = 35.7 ± 6.1 mlkg–1min–1) performed a bout of continuous and a bout of interval exercise (IE) both consisted of 5-min cycling at low intensity [80% of the power output (W) of the predetermined gas exchange threshold (GET) (80%WGET)] and 5-min cycling at high intensity {WGET plus the work rate corresponding to 50% of the difference between peak power output (PPO) at oxygen uptake (VO2max) test and the WGET [WGET + 0.50 Δ(PPO – WGET)]}. CE compared to IE induced significant higher heart rate and ventilation as well as significant higher levels of mouth occlusion pressure for 0.1 s (P0.1) (P < 0.05) during low and high intensities. Our results indicate that CE stimulates respiration more than IE when the exercise is performed at the same relative intensity.  相似文献   

19.
Aim: The aim of this study was to examine the relationship between ventilatory adaptation and performance during altitude training at 2700?m. Methods: Seven elite cyclists (age: 21.2?±?1.1?yr, body mass: 69.9?±?5.6?kg, height 176.3?±?4.9?cm) participated in this study. A hypoxic ventilatory response (HVR) test and a submaximal exercise test were performed at sea level prior to the training camp and again after 15 d at altitude (ALT15). Ventilation (VE), end-tidal carbon-dioxide partial pressure (PETCO2) and oxyhaemoglobin saturation via pulse oximetry (SpO2) were measured at rest and during submaximal cycling at 250?W. A hill climb (HC) performance test was conducted at sea level and after 14 d at altitude (ALT14) using a road of similar length (5.5–6?km) and gradient (4.8–5.3%). Power output was measured using SRM cranks. Average HC power at ALT14 was normalised to sea level power (HC%). Multiple regression was used to identify significant predictors of performance at altitude. Results: At ALT15, there was a significant increase in resting VE (10.3?±?1.9 vs. 12.2?±?2.4?L·min?1) and HVR (0.34?±?0.24 vs. 0.71?±?0.49?L·min?1·%?1), while PETCO2 (38.4?±?2.3 vs. 32.1?±?3.3?mmHg) and SpO2 (97.9?±?0.7 vs. 94.0?±?1.7%) were reduced (P?VE at altitude as significant predictors of HC% (adjusted r2?=?0.913; P?=?0.003). Conclusions: Ventilatory acclimatisation occurred during a 2 wk altitude training camp in elite cyclists and a higher HVR was associated with better performance at altitude, relative to sea level. These results suggest that ventilatory acclimatisation is beneficial for cycling performance at altitude.  相似文献   

20.
ABSTRACT

Purpose: To validate and compare a novel model based on the critical power (CP) concept that describes the entire domain of maximal mean power (MMP) data from cyclists.

Methods: An omni-domain power-duration (OmPD) model was derived whereby the rate of W? expenditure is bound by maximum sprint power and the power at prolonged durations declines from CP log-linearly. The three-parameter CP (3CP) and exponential (Exp) models were likewise extended with the log-linear decay function (Om3CP and OmExp). Each model bounds W? using a different nonconstant function, W?eff (effective W?). Models were fit to MMP data from nine cyclists who also completed four time-trials (TTs).

Results: The OmPD and Om3CP residuals (4 ± 1%) were smaller than the OmExp residuals (6 ± 2%; P < 0.001). W?eff predicted by the OmPD model was stable between 120–1,800 s, whereas it varied for the Om3CP and OmExp models. TT prediction errors were not different between models (7 ± 5%, 8 ± 5%, 7 ± 6%; P = 0.914).

Conclusion: The OmPD offers similar or superior goodness-of-fit and better theoretical properties compared to the other models, such that it best extends the CP concept to short-sprint and prolonged-endurance performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号